-
1
-
-
0033818660
-
Magnetic resonance temperature imaging for guidance of thermotherapy
-
Quesson B, de Zwart JA, Moonen CT. Magnetic resonance temperature imaging for guidance of thermotherapy. J. Magn. Reson. Imaging 2000; 12(4): 525-533.
-
(2000)
J. Magn. Reson. Imaging
, vol.12
, Issue.4
, pp. 525-533
-
-
Quesson, B.1
de Zwart, J.A.2
Moonen, C.T.3
-
2
-
-
2942724152
-
Referenceless PRF shift thermometry
-
Rieke V, Vigen KK, Sommer G, Daniel BL, Pauly JM, Butts K. Referenceless PRF shift thermometry. Magn. Reson. Med. 2004; 51(6): 1223-1231.
-
(2004)
Magn. Reson. Med.
, vol.51
, Issue.6
, pp. 1223-1231
-
-
Rieke, V.1
Vigen, K.K.2
Sommer, G.3
Daniel, B.L.4
Pauly, J.M.5
Butts, K.6
-
3
-
-
0032939464
-
Comparison of four magnetic resonance methods for mapping small temperature changes
-
Wlodarczyk W, Hentschel M, Wust P, Noeske R, Hosten N, Rinneberg H, Felix R. Comparison of four magnetic resonance methods for mapping small temperature changes. Phys. Med. Biol. 1999; 44(2): 607-624.
-
(1999)
Phys. Med. Biol.
, vol.44
, Issue.2
, pp. 607-624
-
-
Wlodarczyk, W.1
Hentschel, M.2
Wust, P.3
Noeske, R.4
Hosten, N.5
Rinneberg, H.6
Felix, R.7
-
4
-
-
33745651362
-
Measurement of regional brain temperature using proton spectroscopic imaging: validation and application to acute ischemic stroke
-
Marshall I, Karaszewski B, Wardlaw JM, Cvoro V, Wartolowska K, Armitage PA, Carpenter T, Bastin ME, Farrall A, Haga K. Measurement of regional brain temperature using proton spectroscopic imaging: validation and application to acute ischemic stroke. Magn. Reson. Imaging 2006; 24(6): 699-706.
-
(2006)
Magn. Reson. Imaging
, vol.24
, Issue.6
, pp. 699-706
-
-
Marshall, I.1
Karaszewski, B.2
Wardlaw, J.M.3
Cvoro, V.4
Wartolowska, K.5
Armitage, P.A.6
Carpenter, T.7
Bastin, M.E.8
Farrall, A.9
Haga, K.10
-
5
-
-
33644791832
-
Reduction of diffusion-weighted MRI lesion volume after early moderate hypothermia in ischemic stroke
-
Berger C, Schramm P, Schwab S. Reduction of diffusion-weighted MRI lesion volume after early moderate hypothermia in ischemic stroke. Stroke 2005; 36(6): e56-58.
-
(2005)
Stroke
, vol.36
, Issue.6
-
-
Berger, C.1
Schramm, P.2
Schwab, S.3
-
6
-
-
0032692630
-
Noninvasive measurement of brain temperature after stroke
-
Corbett RJ, Purdy PD, Laptook AR, Chaney C, Garcia D. Noninvasive measurement of brain temperature after stroke. Am. J. Neuroradiol. 1999; 20(10): 1851-1857.
-
(1999)
Am. J. Neuroradiol.
, vol.20
, Issue.10
, pp. 1851-1857
-
-
Corbett, R.J.1
Purdy, P.D.2
Laptook, A.R.3
Chaney, C.4
Garcia, D.5
-
7
-
-
26244440423
-
Local delivery of magnetic resonance (MR) contrast agent in kidney using thermosensitive liposomes and MR imaging-guided local hyperthermia: a feasibility study in vivo
-
Salomir R, Palussière J, Fossheim SL, Rogstad A, Wiggen UN, Grenier N, Moonen CTW. Local delivery of magnetic resonance (MR) contrast agent in kidney using thermosensitive liposomes and MR imaging-guided local hyperthermia: a feasibility study in vivo. J. Magn. Reson. Imaging 2005; 22(4): 534-540.
-
(2005)
J. Magn. Reson. Imaging
, vol.22
, Issue.4
, pp. 534-540
-
-
Salomir, R.1
Palussière, J.2
Fossheim, S.L.3
Rogstad, A.4
Wiggen, U.N.5
Grenier, N.6
Moonen, C.T.W.7
-
8
-
-
33745077090
-
Hyperthermia mediated liposomal drug delivery
-
Ponce AM, Vujaskovic Z, Yuan F, Needham D, Dewhirst MW. Hyperthermia mediated liposomal drug delivery. Int. J. Hyperth. 2006; 22(3): 205-213.
-
(2006)
Int. J. Hyperth.
, vol.22
, Issue.3
, pp. 205-213
-
-
Ponce, A.M.1
Vujaskovic, Z.2
Yuan, F.3
Needham, D.4
Dewhirst, M.W.5
-
9
-
-
28444486599
-
Paramagnetic thermosensitive liposomes for MR-thermometry
-
Lindner L, Reinl H, Schlemmer M, Stahl R, Peller M. Paramagnetic thermosensitive liposomes for MR-thermometry. Int. J. Hyperth. 2005; 21(6): 575-588.
-
(2005)
Int. J. Hyperth.
, vol.21
, Issue.6
, pp. 575-588
-
-
Lindner, L.1
Reinl, H.2
Schlemmer, M.3
Stahl, R.4
Peller, M.5
-
10
-
-
29344462452
-
MRI thermometry based on PARACEST agents
-
Zhang S, Malloy CR, Sherry AD. MRI thermometry based on PARACEST agents. J. Am. Chem. Soc. 2005; 127(50): 17572-17573.
-
(2005)
J. Am. Chem. Soc.
, vol.127
, Issue.50
, pp. 17572-17573
-
-
Zhang, S.1
Malloy, C.R.2
Sherry, A.D.3
-
11
-
-
0030050040
-
1H magnetic resonance spectroscopy
-
1H magnetic resonance spectroscopy. Magn. Reson. Med. 1996; 35(3): 364-369.
-
(1996)
Magn. Reson. Med.
, vol.35
, Issue.3
, pp. 364-369
-
-
Frenzel, T.1
Roth, K.2
Koßler, S.3
Radüchel, B.4
Bauer, H.5
Platzek, J.6
Weinmann, H.J.7
-
12
-
-
33644836199
-
Investigation of proton density for measuring tissue temperature
-
Chen J, Daniel BL, Pauly KB. Investigation of proton density for measuring tissue temperature. J. Magn. Reson. Imaging 2006; 23(3): 430-434.
-
(2006)
J. Magn. Reson. Imaging
, vol.23
, Issue.3
, pp. 430-434
-
-
Chen, J.1
Daniel, B.L.2
Pauly, K.B.3
-
13
-
-
0024370936
-
Temperature mapping with MR imaging of molecular diffusion: application to hyperthermia
-
Le Bihan D, Delannoy J, Levin RL. Temperature mapping with MR imaging of molecular diffusion: application to hyperthermia. Radiology 1989; 171(3): 853-857.
-
(1989)
Radiology
, vol.171
, Issue.3
, pp. 853-857
-
-
Le Bihan, D.1
Delannoy, J.2
Levin, R.L.3
-
14
-
-
0019185132
-
Temperature relationships of proton spin-lattice relaxation time T1 in biological tissues
-
Lewa CJ, Majewska Z. Temperature relationships of proton spin-lattice relaxation time T1 in biological tissues. Bull. Cancer 1980; 67(5): 525-530.
-
(1980)
Bull. Cancer
, vol.67
, Issue.5
, pp. 525-530
-
-
Lewa, C.J.1
Majewska, Z.2
-
15
-
-
0031933418
-
Time and temperature dependence of MR parameters during thermal coagulation of ex vivo rabbit muscle
-
Graham SJ, Bronskill MJ, Henkelman RM. Time and temperature dependence of MR parameters during thermal coagulation of ex vivo rabbit muscle. Magn. Reson. Med. 1998; 39(2): 198-203.
-
(1998)
Magn. Reson. Med.
, vol.39
, Issue.2
, pp. 198-203
-
-
Graham, S.J.1
Bronskill, M.J.2
Henkelman, R.M.3
-
16
-
-
0028059511
-
Modeling and observation of temperature changes in vivo using MRI
-
Young IR, Hand JW, Oatridge A, Prior MV. Modeling and observation of temperature changes in vivo using MRI. Magn. Reson. Med. 1994; 32(3): 358-369.
-
(1994)
Magn. Reson. Med.
, vol.32
, Issue.3
, pp. 358-369
-
-
Young, I.R.1
Hand, J.W.2
Oatridge, A.3
Prior, M.V.4
-
17
-
-
54249084562
-
Accurate temperature imaging based on intermolecular coherences in magnetic resonance
-
Galiana G, Branca RT, Jenista ER, Warren WS. Accurate temperature imaging based on intermolecular coherences in magnetic resonance. Science 2008; 322(5900): 421-424.
-
(2008)
Science
, vol.322
, Issue.5900
, pp. 421-424
-
-
Galiana, G.1
Branca, R.T.2
Jenista, E.R.3
Warren, W.S.4
-
18
-
-
0030068843
-
Temperature mapping using water proton chemical shift obtained with 3D-MRSI: feasibility in vivo
-
Kuroda K, Suzuki Y, Ishihara Y, Okamoto K. Temperature mapping using water proton chemical shift obtained with 3D-MRSI: feasibility in vivo. Magn. Reson. Med. 1996; 35(1): 20-29.
-
(1996)
Magn. Reson. Med.
, vol.35
, Issue.1
, pp. 20-29
-
-
Kuroda, K.1
Suzuki, Y.2
Ishihara, Y.3
Okamoto, K.4
-
19
-
-
0028785052
-
Precise and fast temperature mapping using water proton chemical-shift
-
Ishihara Y, Calderon A, Watanabe H, Okamoto K, Suzuki Y, Kuroda K, Suzuki Y. Precise and fast temperature mapping using water proton chemical-shift. Magn. Reson. Med. 1995; 34(6): 814-823.
-
(1995)
Magn. Reson. Med.
, vol.34
, Issue.6
, pp. 814-823
-
-
Ishihara, Y.1
Calderon, A.2
Watanabe, H.3
Okamoto, K.4
Suzuki, Y.5
Kuroda, K.6
Suzuki, Y.7
-
20
-
-
0028854080
-
Noninvasive MRI thermometry with the proton resonance frequency (PRF) method: in vivo results in human muscle
-
De Poorter J, De Wagter C, De Deene Y, Thomsen C, Stahlberg F, Achten E. Noninvasive MRI thermometry with the proton resonance frequency (PRF) method: in vivo results in human muscle. Magn. Reson. Med. 1995; 33(1): 74-81.
-
(1995)
Magn. Reson. Med.
, vol.33
, Issue.1
, pp. 74-81
-
-
De Poorter, J.1
De Wagter, C.2
De Deene, Y.3
Thomsen, C.4
Stahlberg, F.5
Achten, E.6
-
21
-
-
84870351692
-
Towards fast and accurate temperature mapping with proton resonance frequency-based MR thermometry
-
Yuan J, Mei CS, Panych LP, McDannold NJ, Madore B. Towards fast and accurate temperature mapping with proton resonance frequency-based MR thermometry. Quant. Imaging Med. Surg. 2012; 2(1): 21-32.
-
(2012)
Quant. Imaging Med. Surg.
, vol.2
, Issue.1
, pp. 21-32
-
-
Yuan, J.1
Mei, C.S.2
Panych, L.P.3
McDannold, N.J.4
Madore, B.5
-
22
-
-
36849111386
-
Proton resonance shift of water in gas and liquid states
-
Hindman JC. Proton resonance shift of water in gas and liquid states. J. Chem. Phys. 1966; 44(12): 4582-4592.
-
(1966)
J. Chem. Phys.
, vol.44
, Issue.12
, pp. 4582-4592
-
-
Hindman, J.C.1
-
25
-
-
28444491453
-
Quantitative MRI-based temperature mapping based on the proton resonant frequency shift: review of validation studies
-
McDannold N. Quantitative MRI-based temperature mapping based on the proton resonant frequency shift: review of validation studies. Int. J. Hyperth. 2005; 21(6): 533-546.
-
(2005)
Int. J. Hyperth.
, vol.21
, Issue.6
, pp. 533-546
-
-
McDannold, N.1
-
26
-
-
0031848730
-
Ex vivo tissue-type independence in proton-resonance frequency shift MR thermometry
-
Peters RTD, Hinks RS, Henkelman RM. Ex vivo tissue-type independence in proton-resonance frequency shift MR thermometry. Magn. Reson. Med. 1998; 40(3): 454-459.
-
(1998)
Magn. Reson. Med.
, vol.40
, Issue.3
, pp. 454-459
-
-
Peters, R.T.D.1
Hinks, R.S.2
Henkelman, R.M.3
-
28
-
-
0029112548
-
Noninvasive MRI thermometry with the proton resonance frequency method: study of susceptibility effects
-
De Poorter J. Noninvasive MRI thermometry with the proton resonance frequency method: study of susceptibility effects. Magn. Reson. Med. 1995; 34(3): 359-367.
-
(1995)
Magn. Reson. Med.
, vol.34
, Issue.3
, pp. 359-367
-
-
De Poorter, J.1
-
29
-
-
77950601928
-
Real-time MR-thermometry and dosimetry for interventional guidance on abdominal organs
-
Roujol S, Ries M, Quesson B, Moonen C, Denis de Senneville B. Real-time MR-thermometry and dosimetry for interventional guidance on abdominal organs. Magn. Reson. Med. 2010; 63(4): 1080-1087.
-
(2010)
Magn. Reson. Med.
, vol.63
, Issue.4
, pp. 1080-1087
-
-
Roujol, S.1
Ries, M.2
Quesson, B.3
Moonen, C.4
Denis de Senneville, B.5
-
30
-
-
79955056851
-
Fast fat-suppressed reduced field-of-view temperature mapping using 2DRF excitation pulses
-
Yuan J, Mei CS, Madore B, McDannold NJ, Panych LP. Fast fat-suppressed reduced field-of-view temperature mapping using 2DRF excitation pulses. J. Magn. Reson. 2011; 210(1): 38-43.
-
(2011)
J. Magn. Reson.
, vol.210
, Issue.1
, pp. 38-43
-
-
Yuan, J.1
Mei, C.S.2
Madore, B.3
McDannold, N.J.4
Panych, L.P.5
-
31
-
-
77955292941
-
Noninvasive temperature mapping with MRI using chemical shift water-fat separation
-
Soher BJ, Wyatt C, Reeder SB, MacFall JR. Noninvasive temperature mapping with MRI using chemical shift water-fat separation. Magn. Reson. Med. 2010; 63(5): 1238-1246.
-
(2010)
Magn. Reson. Med.
, vol.63
, Issue.5
, pp. 1238-1246
-
-
Soher, B.J.1
Wyatt, C.2
Reeder, S.B.3
MacFall, J.R.4
-
32
-
-
67049160813
-
Water saturation shift referencing (WASSR) for chemical exchange saturation transfer (CEST) experiments
-
Kim M, Gillen J, Landman BA, Zhou J, van Zijl PC. Water saturation shift referencing (WASSR) for chemical exchange saturation transfer (CEST) experiments. Magn. Reson. Med. 2009; 61(6): 1441-1450.
-
(2009)
Magn. Reson. Med.
, vol.61
, Issue.6
, pp. 1441-1450
-
-
Kim, M.1
Gillen, J.2
Landman, B.A.3
Zhou, J.4
van Zijl, P.C.5
-
33
-
-
67749096074
-
Direct saturation MRI: theory and application to imaging brain iron
-
Smith SA, Bulte JW, van Zijl PC. Direct saturation MRI: theory and application to imaging brain iron. Magn. Reson. Med. 2009; 62(2): 384-393.
-
(2009)
Magn. Reson. Med.
, vol.62
, Issue.2
, pp. 384-393
-
-
Smith, S.A.1
Bulte, J.W.2
van Zijl, P.C.3
-
34
-
-
77954567160
-
High-throughput screening of chemical exchange saturation transfer MR contrast agents
-
Liu G, Gilad AA, Bulte JWM, Van Zijl PCM, Mcmahon MT. High-throughput screening of chemical exchange saturation transfer MR contrast agents. Contrast Media Mol. Imaging 2010; 5(3): 162-170.
-
(2010)
Contrast Media Mol. Imaging
, vol.5
, Issue.3
, pp. 162-170
-
-
Liu, G.1
Gilad, A.A.2
Bulte, J.W.M.3
Van Zijl, P.C.M.4
Mcmahon, M.T.5
-
35
-
-
0027411977
-
The general-solution to the Bloch equation with constant rf and relaxation terms - application to saturation and slice selection
-
Mulkern RV, Williams ML. The general-solution to the Bloch equation with constant rf and relaxation terms - application to saturation and slice selection. Med. Phys. 1993; 20(1): 5-13.
-
(1993)
Med. Phys.
, vol.20
, Issue.1
, pp. 5-13
-
-
Mulkern, R.V.1
Williams, M.L.2
-
36
-
-
0032924339
-
Heat-source orientation and geometry dependence in proton-resonance frequency shift MR thermometry
-
Peters R, Hinks R, Henkelman R. Heat-source orientation and geometry dependence in proton-resonance frequency shift MR thermometry. Magn. Reson. Med. 1999; 41: 909-918.
-
(1999)
Magn. Reson. Med.
, vol.41
, pp. 909-918
-
-
Peters, R.1
Hinks, R.2
Henkelman, R.3
-
37
-
-
0027411977
-
The general solution to the Bloch equation with constant rf and relaxation terms: application to saturation and slice selection
-
Mulkern RV, Williams ML. The general solution to the Bloch equation with constant rf and relaxation terms: application to saturation and slice selection. Med. Phys. 1993; 20(1): 5-13.
-
(1993)
Med. Phys.
, vol.20
, Issue.1
, pp. 5-13
-
-
Mulkern, R.V.1
Williams, M.L.2
-
38
-
-
84872899963
-
NOrmalized MAgnetization Ratio (NOMAR) filtering for creation of tissue selective contrast maps
-
Liu G, Chan KW, Song X, Zhang J, Gilad AA, Bulte JW, van Zijl PC, McMahon MT. NOrmalized MAgnetization Ratio (NOMAR) filtering for creation of tissue selective contrast maps. Magn. Reson. Med. 2013; 69(2): 516-523.
-
(2013)
Magn. Reson. Med.
, vol.69
, Issue.2
, pp. 516-523
-
-
Liu, G.1
Chan, K.W.2
Song, X.3
Zhang, J.4
Gilad, A.A.5
Bulte, J.W.6
van Zijl, P.C.7
McMahon, M.T.8
-
39
-
-
0001217756
-
A simple multinuclear NMR thermometer
-
Ammann C, Meier P, Merbach A. A simple multinuclear NMR thermometer. J. Magn. Reson. 1982; 46(2): 319-321.
-
(1982)
J. Magn. Reson.
, vol.46
, Issue.2
, pp. 319-321
-
-
Ammann, C.1
Meier, P.2
Merbach, A.3
-
40
-
-
0031898928
-
Tissue temperature monitoring with multiple gradient-echo imaging sequences
-
Mulkern RV, Panych LP, Hynynen K, Jolesz FA, McDannold NJ. Tissue temperature monitoring with multiple gradient-echo imaging sequences. J. Magn. Reson. Imaging 1998; 8(2): 493-502.
-
(1998)
J. Magn. Reson. Imaging
, vol.8
, Issue.2
, pp. 493-502
-
-
Mulkern, R.V.1
Panych, L.P.2
Hynynen, K.3
Jolesz, F.A.4
McDannold, N.J.5
-
42
-
-
0027633059
-
"Keyhole" method for accelerating imaging of contrast agent uptake
-
Van Vaals J, Brummer M, Dixon W, Tuithof H, Engels H, Nelson R, Gerety B, Chezmar J, Den Boer J. "Keyhole" method for accelerating imaging of contrast agent uptake. J. Magn. Reson. Imaging 1993; 3: 671-675.
-
(1993)
J. Magn. Reson. Imaging
, vol.3
, pp. 671-675
-
-
Van Vaals, J.1
Brummer, M.2
Dixon, W.3
Tuithof, H.4
Engels, H.5
Nelson, R.6
Gerety, B.7
Chezmar, J.8
Den Boer, J.9
-
43
-
-
84908219488
-
Statistical methods for assessing agreement between two methods of clinical measurement
-
Bland J, Altman D. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986; 1(8476): 307-310.
-
(1986)
Lancet
, vol.1
, Issue.8476
, pp. 307-310
-
-
Bland, J.1
Altman, D.2
-
44
-
-
0033979022
-
Temperature mapping using the water proton chemical shift: self-referenced method with echo-planar spectroscopic imaging
-
Kuroda K, Mulkern RV, Oshio K, Panych LP, Nakai T, Moriya T, Okuda S, Hynynen K, Jolesz FA. Temperature mapping using the water proton chemical shift: self-referenced method with echo-planar spectroscopic imaging. Magn. Reson. Med. 2000; 43(2): 220-225.
-
(2000)
Magn. Reson. Med.
, vol.43
, Issue.2
, pp. 220-225
-
-
Kuroda, K.1
Mulkern, R.V.2
Oshio, K.3
Panych, L.P.4
Nakai, T.5
Moriya, T.6
Okuda, S.7
Hynynen, K.8
Jolesz, F.A.9
-
45
-
-
84859104671
-
In vivo multicolor molecular MR imaging using diamagnetic chemical exchange saturation transfer liposomes
-
Liu G, Moake M, Har-el Y-e, Long CM, Chan KWY, Cardona A, Jamil M, Walczak P, Gilad AA, Sgouros G, van Zijl PCM, Bulte JWM, McMahon MT. In vivo multicolor molecular MR imaging using diamagnetic chemical exchange saturation transfer liposomes. Magn. Reson. Med. 2012; 67(4): 1106-1113.
-
(2012)
Magn. Reson. Med.
, vol.67
, Issue.4
, pp. 1106-1113
-
-
Liu, G.1
Moake, M.2
Har-el, Y.-E.3
Long, C.M.4
Chan, K.W.Y.5
Cardona, A.6
Jamil, M.7
Walczak, P.8
Gilad, A.A.9
Sgouros, G.10
van Zijl, P.C.M.11
Bulte, J.W.M.12
McMahon, M.T.13
-
46
-
-
77954567160
-
High-throughput screening of chemical exchange saturation transfer MR contrast agents
-
Liu G, Gilad AA, Bulte JWM, Van Zijl PCM, Mcmahon MT. High-throughput screening of chemical exchange saturation transfer MR contrast agents. Contrast Media Mol. Imaging 2010; 5(3): 162-170.
-
(2010)
Contrast Media Mol. Imaging
, vol.5
, Issue.3
, pp. 162-170
-
-
Liu, G.1
Gilad, A.A.2
Bulte, J.W.M.3
Van Zijl, P.C.M.4
Mcmahon, M.T.5
-
47
-
-
84862660362
-
Comprehensive analysis of the Cramer-Rao bounds for magnetic resonance temperature change measurement in fat-water voxels using multi-echo imaging
-
Wyatt C, Soher BJ, Arunachalam K, MacFall J. Comprehensive analysis of the Cramer-Rao bounds for magnetic resonance temperature change measurement in fat-water voxels using multi-echo imaging. Magn. Reson. Mater. Phys. Biol. Med. 2012; 25(1): 49-61.
-
(2012)
Magn. Reson. Mater. Phys. Biol. Med.
, vol.25
, Issue.1
, pp. 49-61
-
-
Wyatt, C.1
Soher, B.J.2
Arunachalam, K.3
MacFall, J.4
-
48
-
-
77954133822
-
Reduced field-of-view single-shot fast spin echo imaging using two-dimensional spatially selective radiofrequency pulses
-
Yuan J, Zhao TC, Tang Y, Panych LP. Reduced field-of-view single-shot fast spin echo imaging using two-dimensional spatially selective radiofrequency pulses. J Magn Reson Imaging 2010; 32: 242-248.
-
(2010)
J Magn Reson Imaging
, vol.32
, pp. 242-248
-
-
Yuan, J.1
Zhao, T.C.2
Tang, Y.3
Panych, L.P.4
-
50
-
-
77956368292
-
Fast 3D chemical exchange saturation transfer (CEST) imaging of the human brain
-
Zhu H, Jones CK, van Zijl PCM, Barker PB, Zhou J. Fast 3D chemical exchange saturation transfer (CEST) imaging of the human brain. Magn. Reson. Med. 2010; 64(3): 638-644.
-
(2010)
Magn. Reson. Med.
, vol.64
, Issue.3
, pp. 638-644
-
-
Zhu, H.1
Jones, C.K.2
van Zijl, P.C.M.3
Barker, P.B.4
Zhou, J.5
-
51
-
-
53549091343
-
Practical data acquisition method for human brain tumor amide proton transfer (APT) imaging
-
Zhou J, Blakeley JO, Hua J, Kim M, Laterra J, Pomper MG, van Zijl PC. Practical data acquisition method for human brain tumor amide proton transfer (APT) imaging. Magn. Reson. Med. 2008; 60(4): 842-849.
-
(2008)
Magn. Reson. Med.
, vol.60
, Issue.4
, pp. 842-849
-
-
Zhou, J.1
Blakeley, J.O.2
Hua, J.3
Kim, M.4
Laterra, J.5
Pomper, M.G.6
van Zijl, P.C.7
-
52
-
-
84879555302
-
Nuts and bolts of chemical exchange saturation transfer MRI
-
DOI: 10.1002/nbm.2899
-
Liu G, Song X, Chan KW, McMahon MT. Nuts and bolts of chemical exchange saturation transfer MRI. NMR Biomed. 2013. DOI: 10.1002/nbm.2899
-
(2013)
NMR Biomed.
-
-
Liu, G.1
Song, X.2
Chan, K.W.3
McMahon, M.T.4
-
53
-
-
0042466426
-
Using the amide proton signals of intracellular proteins and peptides to detect pH effects in MRI
-
Zhou J, Payen JF, Wilson DA, Traystman RJ, van Zijl PC. Using the amide proton signals of intracellular proteins and peptides to detect pH effects in MRI. Nat. Med. 2003; 9(8): 1085-1090.
-
(2003)
Nat. Med.
, vol.9
, Issue.8
, pp. 1085-1090
-
-
Zhou, J.1
Payen, J.F.2
Wilson, D.A.3
Traystman, R.J.4
van Zijl, P.C.5
-
54
-
-
60549107250
-
PARACEST MRI with improved temporal resolution
-
Liu G, Ali MM, Yoo B, Griswold MA, Tkach JA, Pagel MD. PARACEST MRI with improved temporal resolution. Magn. Reson. Med. 2009; 61(2): 399-408.
-
(2009)
Magn. Reson. Med.
, vol.61
, Issue.2
, pp. 399-408
-
-
Liu, G.1
Ali, M.M.2
Yoo, B.3
Griswold, M.A.4
Tkach, J.A.5
Pagel, M.D.6
-
55
-
-
79251575005
-
CEST-FISP: A novel technique for rapid chemical exchange saturation transfer MRI at 7 T
-
Shah T, Lu L, Dell K, Pagel M, Griswold M, Flask C. CEST-FISP: A novel technique for rapid chemical exchange saturation transfer MRI at 7 T. Magn. Reson. Med. 2011; 65(2): 432-437.
-
(2011)
Magn. Reson. Med.
, vol.65
, Issue.2
, pp. 432-437
-
-
Shah, T.1
Lu, L.2
Dell, K.3
Pagel, M.4
Griswold, M.5
Flask, C.6
-
56
-
-
73349139158
-
A multislice gradient echo pulse sequence for CEST imaging
-
Dixon WT, Hancu I, Ratnakar SJ, Sherry AD, Lenkinski RE, Alsop DC. A multislice gradient echo pulse sequence for CEST imaging. Magn. Reson. Med. 2010; 63(1): 253-256.
-
(2010)
Magn. Reson. Med.
, vol.63
, Issue.1
, pp. 253-256
-
-
Dixon, W.T.1
Hancu, I.2
Ratnakar, S.J.3
Sherry, A.D.4
Lenkinski, R.E.5
Alsop, D.C.6
|