메뉴 건너뛰기




Volumn 8, Issue 2, 1998, Pages 493-502

Tissue temperature monitoring with multiple gradient-echo imaging sequences

Author keywords

Fast Imaging; Frequency maps; Gradient echo; Phase maps; Tissue temperature

Indexed keywords

ARTICLE; HUMAN; NUCLEAR MAGNETIC RESONANCE IMAGING; PRIORITY JOURNAL; RADIOFREQUENCY; SIGNAL PROCESSING; THERMOGRAPHY;

EID: 0031898928     PISSN: 10531807     EISSN: None     Source Type: Journal    
DOI: 10.1002/jmri.1880080234     Document Type: Article
Times cited : (49)

References (18)
  • 1
    • 84972971117 scopus 로고
    • Body temperature mapping by magnetic resonance imaging
    • Lewa CJ, de Certaines JD. Body temperature mapping by magnetic resonance imaging. Spect Lett 1994; 27:1369-1419.
    • (1994) Spect Lett , vol.27 , pp. 1369-1419
    • Lewa, C.J.1    De Certaines, J.D.2
  • 2
    • 0029958301 scopus 로고    scopus 로고
    • Optimization of spoiled gradient-echo phase imaging for in vivo localization of a focused ultrasound beam
    • Chung AH, Hynynen K, Colucci V, Oshio K, Cline HE, Jolesz FA. Optimization of spoiled gradient-echo phase imaging for in vivo localization of a focused ultrasound beam. Magn Reson Med 1996; 36:745-752.
    • (1996) Magn Reson Med , vol.36 , pp. 745-752
    • Chung, A.H.1    Hynynen, K.2    Colucci, V.3    Oshio, K.4    Cline, H.E.5    Jolesz, F.A.6
  • 3
    • 0028854080 scopus 로고
    • Non-invasive MRI thermometry with the proton resonance frequency (PRF) method: In vivo results in human muscle
    • De Poorter J. De Wagter C, De Deene Y, Thomsen C, Stahlberg F, Achten E. Non-invasive MRI thermometry with the proton resonance frequency (PRF) method: in vivo results in human muscle. Magn Reson Med 1995; 33:74-81.
    • (1995) Magn Reson Med , vol.33 , pp. 74-81
    • De Poorter, J.1    De Wagter, C.2    De Deene, Y.3    Thomsen, C.4    Stahlberg, F.5    Achten, E.6
  • 5
    • 8044243593 scopus 로고    scopus 로고
    • Magnetic resonance imaging of temperature changes during interstitial microwave heating: A phantom study
    • Vitkin IA, Moriarty JA, Peters RD, et al. Magnetic resonance imaging of temperature changes during interstitial microwave heating: a phantom study. Med Phys 1997; 24:269-277.
    • (1997) Med Phys , vol.24 , pp. 269-277
    • Vitkin, I.A.1    Moriarty, J.A.2    Peters, R.D.3
  • 6
    • 0030048172 scopus 로고    scopus 로고
    • Simultaneous magnetic resonance phase and magnitude temperature maps in muscle
    • Cline HE, Hynynen K, Schneider E, et al. Simultaneous magnetic resonance phase and magnitude temperature maps in muscle. Magn Reson Med 1996; 35:309-315.
    • (1996) Magn Reson Med , vol.35 , pp. 309-315
    • Cline, H.E.1    Hynynen, K.2    Schneider, E.3
  • 7
    • 0030726452 scopus 로고    scopus 로고
    • Temperature mapping using the water proton chemical shift: A chemical shift selective phase mapping method
    • Kuroda K, Oshio K, Chung AH, Hynynen K, Jolesz FA. Temperature mapping using the water proton chemical shift: a chemical shift selective phase mapping method. Magn Reson Med 1997: 38:845-851.
    • (1997) Magn Reson Med , vol.38 , pp. 845-851
    • Kuroda, K.1    Oshio, K.2    Chung, A.H.3    Hynynen, K.4    Jolesz, F.A.5
  • 8
    • 0029677201 scopus 로고    scopus 로고
    • A clinical, noninvasive MR imaging-monitored ultrasound surgery method
    • Hynynen K, Freund WR, Cline HE, et al. A clinical, noninvasive MR imaging-monitored ultrasound surgery method. Radiographics 1996; 16:185-195.
    • (1996) Radiographics , vol.16 , pp. 185-195
    • Hynynen, K.1    Freund, W.R.2    Cline, H.E.3
  • 9
    • 0028909267 scopus 로고
    • Focused US system for MR imaging - Guided tumor ablation
    • Cline HE, Hynynen K, Watkins RD, et al. Focused US system for MR imaging - guided tumor ablation. Radiology 1995; 194: 731-737.
    • (1995) Radiology , vol.194 , pp. 731-737
    • Cline, H.E.1    Hynynen, K.2    Watkins, R.D.3
  • 10
    • 0024546915 scopus 로고
    • Correction of phase wrapping in magnetic resonance imaging
    • Axel L, Morton D. Correction of phase wrapping in magnetic resonance imaging. Med Phys 1989; 16:284-287.
    • (1989) Med Phys , vol.16 , pp. 284-287
    • Axel, L.1    Morton, D.2
  • 11
    • 0029053859 scopus 로고
    • MR geometric distortion correction for improved frame-based stereotaxic target localization accuracy
    • Sumanaweera TS, Glover GH, Hemler PF, et al. MR geometric distortion correction for improved frame-based stereotaxic target localization accuracy. Magn Reson Med 1995; 34:106-113.
    • (1995) Magn Reson Med , vol.34 , pp. 106-113
    • Sumanaweera, T.S.1    Glover, G.H.2    Hemler, P.F.3
  • 12
    • 0021958023 scopus 로고
    • MR image artifacts from periodic motion
    • Wood ML, Henkelman RM. MR image artifacts from periodic motion. Magn Reson Med 1985; 12:143-151.
    • (1985) Magn Reson Med , vol.12 , pp. 143-151
    • Wood, M.L.1    Henkelman, R.M.2
  • 13
    • 0030048788 scopus 로고    scopus 로고
    • Phase-encode reordering to minimize errors caused by motion
    • Macgowan CK, Wood ML. Phase-encode reordering to minimize errors caused by motion. Magn Reson Med 1996; 35:391-398.
    • (1996) Magn Reson Med , vol.35 , pp. 391-398
    • Macgowan, C.K.1    Wood, M.L.2
  • 14
    • 0024394981 scopus 로고
    • Motional phase artifacts in Fourier transform MRI
    • Wedeen VJ, Wendt RE III, Herold MJ. Motional phase artifacts in Fourier transform MRI. Magn Reson Med 1989; 11:114-120.
    • (1989) Magn Reson Med , vol.11 , pp. 114-120
    • Wedeen, V.J.1    Wendt R.E. III2    Herold, M.J.3
  • 16
    • 0026344889 scopus 로고
    • On the nature and reduction of the displacement artifact in flow images
    • Nishimura DG, Jackson JI, Pauly JM. On the nature and reduction of the displacement artifact in flow images. Magn Reson Med 1991; 22:481-492.
    • (1991) Magn Reson Med , vol.22 , pp. 481-492
    • Nishimura, D.G.1    Jackson, J.I.2    Pauly, J.M.3
  • 17
    • 0031403409 scopus 로고    scopus 로고
    • Combined analysis of spatial and velocity displacement artifacts in phase contrast measurements of complex flows
    • Steinman DA, Ethier CR, Rutt BK. Combined analysis of spatial and velocity displacement artifacts in phase contrast measurements of complex flows. JMRI 1997; 7:339-346.
    • (1997) JMRI , vol.7 , pp. 339-346
    • Steinman, D.A.1    Ethier, C.R.2    Rutt, B.K.3
  • 18
    • 0029063215 scopus 로고
    • Motion induced phase shifts in MR: Acceleration effects in quantitative flow measurements - A reconsideration
    • Kouwenhoven M, Hofman MBM, Sprenger M. Motion induced phase shifts in MR: acceleration effects in quantitative flow measurements - a reconsideration. Magn Reson Med 1995; 33: 766-777.
    • (1995) Magn Reson Med , vol.33 , pp. 766-777
    • Kouwenhoven, M.1    Hofman, M.B.M.2    Sprenger, M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.