-
1
-
-
0034145982
-
A new class of contrast agents for MRI based on proton chemical exchange dependent saturation transfer (CEST)
-
Ward KM, Aletras AH, Balaban RS,. A new class of contrast agents for MRI based on proton chemical exchange dependent saturation transfer (CEST). J Magn Res 2000; 143: 79-87.
-
(2000)
J Magn Res
, vol.143
, pp. 79-87
-
-
Ward, K.M.1
Aletras, A.H.2
Balaban, R.S.3
-
2
-
-
77952469138
-
Alternatives to gadolinium-based metal chelates for magnetic resonance imaging
-
Viswanathan S, Kovacs Z, Green K, Ratnakar S, Sherry A,. Alternatives to gadolinium-based metal chelates for magnetic resonance imaging. Chem Rev 2010; 110: 2960-3018.
-
(2010)
Chem Rev
, vol.110
, pp. 2960-3018
-
-
Viswanathan, S.1
Kovacs, Z.2
Green, K.3
Ratnakar, S.4
Sherry, A.5
-
3
-
-
77951553892
-
Encoding the frequency dependence in MRI contrast media: The emerging class of CEST agents
-
Terreno E, Castelli D, Aime S,. Encoding the frequency dependence in MRI contrast media: the emerging class of CEST agents. Contrast Media Mol Imaging 2010; 5: 78-98.
-
(2010)
Contrast Media Mol Imaging
, vol.5
, pp. 78-98
-
-
Terreno, E.1
Castelli, D.2
Aime, S.3
-
4
-
-
33747238228
-
Chemical exchange saturation transfer imaging and spectroscopy
-
Zhou J, Zijl P,. Chemical exchange saturation transfer imaging and spectroscopy. Prog Nucl Magn Reson Spectrosc 2006; 48: 109-136.
-
(2006)
Prog Nucl Magn Reson Spectrosc
, vol.48
, pp. 109-136
-
-
Zhou, J.1
Zijl, P.2
-
5
-
-
79952782590
-
Chemical exchange saturation transfer (CEST): What is in a name and what isn't?
-
van Zijl PC, Yadav NN,. Chemical exchange saturation transfer (CEST): what is in a name and what isn't? Magn Reson Med 2011; 65: 927-948.
-
(2011)
Magn Reson Med
, vol.65
, pp. 927-948
-
-
Van Zijl, P.C.1
Yadav, N.N.2
-
6
-
-
66249104627
-
Feasibility of concurrent dual contrast enhancement using CEST contrast agents and superparamagnetic iron oxide particles
-
Gilad AA, van Laarhoven HW, McMahon MT, Walczak P, Heerschap A, Neeman M, van Zijl PC, Bulte JW,. Feasibility of concurrent dual contrast enhancement using CEST contrast agents and superparamagnetic iron oxide particles. Magn Reson Med 2009; 61: 970-974.
-
(2009)
Magn Reson Med
, vol.61
, pp. 970-974
-
-
Gilad, A.A.1
Van Laarhoven, H.W.2
McMahon, M.T.3
Walczak, P.4
Heerschap, A.5
Neeman, M.6
Van Zijl, P.C.7
Bulte, J.W.8
-
7
-
-
23844439261
-
1 pulses for imaging of the effects of PARACEST agents
-
DOI 10.1016/j.jmr.2005.05.016, PII S1090780705001692
-
Vinogradov E, Zhang S, Lubag A, Balschi J, Sherry A, Lenkinski R,. On-resonance low pulses for imaging of the effects of PARACEST agents. J Magn Reson 2005; 176: 54-63. (Pubitemid 41162475)
-
(2005)
Journal of Magnetic Resonance
, vol.176
, Issue.1
, pp. 54-63
-
-
Vinogradov, E.1
Zhang, S.2
Lubag, A.3
Balschi, J.A.4
Sherry, A.D.5
Lenkinski, R.E.6
-
8
-
-
53549113087
-
New "multicolor" polypeptide diamagnetic chemical exchange saturation transfer (DIACEST) contrast agents for MRI
-
McMahon MT, Gilad AA, DeLiso MA, Berman SM, Bulte JW, van Zijl PC,. New "multicolor" polypeptide diamagnetic chemical exchange saturation transfer (DIACEST) contrast agents for MRI. Magn Reson Med 2008; 60: 803-812.
-
(2008)
Magn Reson Med
, vol.60
, pp. 803-812
-
-
McMahon, M.T.1
Gilad, A.A.2
Deliso, M.A.3
Berman, S.M.4
Bulte, J.W.5
Van Zijl, P.C.6
-
9
-
-
77954567160
-
High-throughput screening of chemical exchange saturation transfer MR contrast agents
-
Liu G, Gilad AA, Bulte JW, van Zijl PC, McMahon MT,. High-throughput screening of chemical exchange saturation transfer MR contrast agents. Contrast Media Mol Imaging 2010; 5: 162-170.
-
(2010)
Contrast Media Mol Imaging
, vol.5
, pp. 162-170
-
-
Liu, G.1
Gilad, A.A.2
Bulte, J.W.3
Van Zijl, P.C.4
McMahon, M.T.5
-
10
-
-
84859104671
-
In vivo multicolor molecular MR imaging using diamagnetic chemical exchange saturation transfer liposomes
-
Liu G, Moake M, Har-el Y-E, Long CM, Chan KWY, Cardona A, Jamil M, Walczak P, Gilad AA, Sgouros G, van Zijl PCM, Bulte JWM, McMahon MT,. In vivo multicolor molecular MR imaging using diamagnetic chemical exchange saturation transfer liposomes. Magn Reson Med 2012; 67: 1106-1113.
-
(2012)
Magn Reson Med
, vol.67
, pp. 1106-1113
-
-
Liu, G.1
Moake, M.2
Har-El, Y.-E.3
Long, C.M.4
Chan, K.W.Y.5
Cardona, A.6
Jamil, M.7
Walczak, P.8
Gilad, A.A.9
Sgouros, G.10
Van Zijl, P.C.M.11
Bulte, J.W.M.12
McMahon, M.T.13
-
11
-
-
17044392297
-
Tunable imaging of cells labeled with MRI-PARACEST agents
-
Aime S, Carrera C, Delli Castelli D, Geninatti Crich S, Terreno E,. Tunable imaging of cells labeled with MRI-PARACEST agents. Angew Chem Int Ed Engl 2005; 44: 1813-1815.
-
(2005)
Angew Chem Int Ed Engl
, vol.44
, pp. 1813-1815
-
-
Aime, S.1
Carrera, C.2
Delli Castelli, D.3
Geninatti Crich, S.4
Terreno, E.5
-
12
-
-
2342511016
-
Quantitative Description of Proton Exchange Processes between Water and Endogenous and Exogenous Agents for WEX, CEST, and APT Experiments
-
DOI 10.1002/mrm.20048
-
Zhou J, Wilson DA, Sun PZ, Klaus JA, Van Zijl PC,. Quantitative description of proton exchange processes between water and endogenous and exogenous agents for WEX, CEST, and APT experiments. Magn Reson Med 2004; 51: 945-952. (Pubitemid 38580606)
-
(2004)
Magnetic Resonance in Medicine
, vol.51
, Issue.5
, pp. 945-952
-
-
Zhou, J.1
Wilson, D.A.2
Sun, P.Z.3
Klaus, J.A.4
Van Zijl, P.C.M.5
-
13
-
-
16444362041
-
Numerical solution of the Bloch equations provides insights into the optimum design of PARACEST agents for MRI
-
DOI 10.1002/mrm.20408
-
Woessner DE, Zhang S, Merritt ME, Sherry AD,. Numerical solution of the Bloch equations provides insights into the optimum design of PARACEST agents for MRI. Magn Reson Med 2005; 53: 790-799. (Pubitemid 40478426)
-
(2005)
Magnetic Resonance in Medicine
, vol.53
, Issue.4
, pp. 790-799
-
-
Woessner, D.E.1
Zhang, S.2
Merritt, M.E.3
Sherry, A.D.4
-
14
-
-
84863154445
-
Imaging in vivo extracellular pH with a single paramagnetic chemical exchange saturation transfer magnetic resonance imaging contrast agent
-
Liu G, Li Y, Sheth VR, Pagel MD,. Imaging in vivo extracellular pH with a single paramagnetic chemical exchange saturation transfer magnetic resonance imaging contrast agent. Mol Imaging 2012; 11: 47-57.
-
(2012)
Mol Imaging
, vol.11
, pp. 47-57
-
-
Liu, G.1
Li, Y.2
Sheth, V.R.3
Pagel, M.D.4
-
15
-
-
0027411977
-
The general solution to the Bloch equation with constant rf and relaxation terms: Application to saturation and slice selection
-
DOI 10.1118/1.597063
-
Mulkern RV, Williams ML,. The general solution to the Bloch equation with constant rf and relaxation terms: application to saturation and slice selection. Med Phys 1993; 20: 5-13. (Pubitemid 23069852)
-
(1993)
Medical Physics
, vol.20
, Issue.1
, pp. 5-13
-
-
Mulkern, R.V.1
Williams, M.L.2
-
17
-
-
0024573913
-
Magnetization transfer contrast (MTC) and tissue water proton relaxation in vivo
-
DOI 10.1002/mrm.1910100113
-
Wolff SD, Balaban RS,. Magnetization transfer contrast (MTC) and tissue water proton relaxation in vivo. Magn Reson Med 1989; 10: 135-144. (Pubitemid 19107973)
-
(1989)
Magnetic Resonance in Medicine
, vol.10
, Issue.1
, pp. 135-144
-
-
Wolff, S.D.1
Balaban, R.S.2
-
18
-
-
0030049337
-
Perfusion imaging with compensation for asymmetric magnetization transfer effects
-
DOI 10.1002/mrm.1910350110
-
Pekar J, Jezzard P, Roberts DA, Leigh JS Jr, Frank JA, McLaughlin AC,. Perfusion imaging with compensation for asymmetric magnetization transfer effects. Magn Reson Med 1996; 35: 70-79. (Pubitemid 26017921)
-
(1996)
Magnetic Resonance in Medicine
, vol.35
, Issue.1
, pp. 70-79
-
-
Pekar, J.1
Jezzard, P.2
Roberts, D.A.3
Leigh Jr., J.S.4
Frank, J.A.5
McLaughlin, A.G.6
-
19
-
-
0032112415
-
Detection of Proton Chemical Exchange between Metabolites and Water in Biological Tissues
-
Guivel-Scharen V, Sinnwell T, Wolff SD, Balaban RS,. Detection of proton chemical exchange between metabolites and water in biological tissues. J Magn Reson 1998; 133: 36-45. (Pubitemid 128450608)
-
(1998)
Journal of Magnetic Resonance
, vol.133
, Issue.1
, pp. 36-45
-
-
Guivel-Scharen, V.1
Sinnwell, T.2
Wolff, S.D.3
Balaban, R.S.4
-
20
-
-
0345600052
-
Amide Proton Transfer (APT) Contrast for Imaging of Brain Tumors
-
DOI 10.1002/mrm.10651
-
Zhou J, Lal B, Wilson DA, Laterra J, van Zijl P,. Amide proton transfer (APT) contrast for imaging of brain tumors. Magn Reson Med 2003; 50: 1120-1126. (Pubitemid 37494013)
-
(2003)
Magnetic Resonance in Medicine
, vol.50
, Issue.6
, pp. 1120-1126
-
-
Zhou, J.1
Lal, B.2
Wilson, D.A.3
Laterra, J.4
Van Zijl, P.C.M.5
-
21
-
-
34248376979
-
MRI detection of glycogen in vivo by using chemical exchange saturation transfer imaging (glycoCEST)
-
DOI 10.1073/pnas.0700281104
-
van Zijl PC, Jones CK, Ren J, Malloy CR, Sherry AD,. MRI detection of glycogen in vivo by using chemical exchange saturation transfer imaging (glycoCEST). Proc Natl Acad Sci USA 2007; 104: 4359-4364. (Pubitemid 47186231)
-
(2007)
Proceedings of the National Academy of Sciences of the United States of America
, vol.104
, Issue.11
, pp. 4359-4364
-
-
Van Zijl, P.C.M.1
Jones, C.K.2
Ren, J.3
Malloy, C.R.4
Sherry, A.D.5
-
22
-
-
84866731829
-
CEST phase mapping using a length and offset varied saturation (LOVARS) scheme
-
Song X, Gilad AA, Joel S, Liu G, Bar-Shir A, Liang Y, Gorelik M, Pekar JJ, van Zijl PCM, Bulte JWM, McMahon MT,. CEST phase mapping using a length and offset varied saturation (LOVARS) scheme. Magn Reson Med. 2012; 68: 1074-1086.
-
(2012)
Magn Reson Med.
, vol.68
, pp. 1074-1086
-
-
Song, X.1
Gilad, A.A.2
Joel, S.3
Liu, G.4
Bar-Shir, A.5
Liang, Y.6
Gorelik, M.7
Pekar, J.J.8
Van Zijl, P.C.M.9
Bulte, J.W.M.10
McMahon, M.T.11
-
23
-
-
77249173821
-
Indirect detection of labile solute proton spectra via the water signal using frequency-labeled exchange (FLEX) transfer
-
Friedman JI, McMahon MT, Stivers JT, Van Zijl PC,. Indirect detection of labile solute proton spectra via the water signal using frequency-labeled exchange (FLEX) transfer. J Am Chem Soc 2010; 132: 1813-1815.
-
(2010)
J Am Chem Soc
, vol.132
, pp. 1813-1815
-
-
Friedman, J.I.1
McMahon, M.T.2
Stivers, J.T.3
Van Zijl, P.C.4
-
24
-
-
67049160813
-
Water saturation shift referencing (WASSR) for chemical exchange saturation transfer (CEST) experiments
-
Kim M, Gillen J, Landman B, Zhou J, van Zijl PC,. Water saturation shift referencing (WASSR) for chemical exchange saturation transfer (CEST) experiments. Magn Reson Med 2009; 61: 1441-1450.
-
(2009)
Magn Reson Med
, vol.61
, pp. 1441-1450
-
-
Kim, M.1
Gillen, J.2
Landman, B.3
Zhou, J.4
Van Zijl, P.C.5
-
25
-
-
71649104936
-
Methods for an improved detection of the MRI-CEST effect
-
Terreno E, Stancanello J, Longo D, Castelli DD, Milone L, Sanders HM, Kok MB, Uggeri F, Aime S,. Methods for an improved detection of the MRI-CEST effect. Contrast Media Mol Imaging 2009; 4: 237-247.
-
(2009)
Contrast Media Mol Imaging
, vol.4
, pp. 237-247
-
-
Terreno, E.1
Stancanello, J.2
Longo, D.3
Castelli, D.D.4
Milone, L.5
Sanders, H.M.6
Kok, M.B.7
Uggeri, F.8
Aime, S.9
-
26
-
-
0035282964
-
Magnetization transfer histogram parameters reflect all dimensions of MS pathology, including atrophy
-
DOI 10.1016/S0022-510X(01)00431-2, PII S0022510X01004312
-
Kalkers NF, Hintzen RQ, van Waesberghe JH, Lazeron RH, van Schijndel RA, Ader HJ, Polman CH, Barkhof F,. Magnetization transfer histogram parameters reflect all dimensions of MS pathology, including atrophy. J Neurol Sci 2001; 184: 155-162. (Pubitemid 32178269)
-
(2001)
Journal of the Neurological Sciences
, vol.184
, Issue.2
, pp. 155-162
-
-
Kalkers, N.F.1
Hintzen, R.Q.2
Van Waesberghe, J.H.T.M.3
Lazeron, R.H.C.4
Van Schijndel, R.A.5
Ader, H.J.6
Polman, C.H.7
Barkhof, F.8
-
27
-
-
0029113464
-
The application of magnetization transfer to MR angiography with reduced total power
-
Parker DL, Buswell HR, Goodrich KC, Alexander AL, Keck N, Tsuruda JS,. The application of magnetization transfer to MR angiography with reduced total power. Magn Reson Med 1995; 34: 283-286.
-
(1995)
Magn Reson Med
, vol.34
, pp. 283-286
-
-
Parker, D.L.1
Buswell, H.R.2
Goodrich, K.C.3
Alexander, A.L.4
Keck, N.5
Tsuruda, J.S.6
-
28
-
-
0027312482
-
Quantitative interpretation of magnetization transfer
-
Henkelman RM, Huang X, Xiang QS, Stanisz GJ, Swanson SD, Bronskill MJ,. Quantitative interpretation of magnetization transfer. Magn Reson Med 1993; 29: 759-766. (Pubitemid 23182857)
-
(1993)
Magnetic Resonance in Medicine
, vol.29
, Issue.6
, pp. 759-766
-
-
Henkelman, R.M.1
Huang, X.2
Xiang, Q.-S.3
Stanisz, G.J.4
Swanson, S.D.5
Bronskill, M.J.6
-
29
-
-
0029353626
-
Modeling magnetization transfer for biological-like systems using a semi-solid pool with a super-Lorentzian lineshape and dipolar reservoir
-
Morrison C, Stanisz G, Henkelman RM,. Modeling magnetization transfer for biological-like systems using a semi-solid pool with a super-Lorentzian lineshape and dipolar reservoir. J Magn Reson B 1995; 108: 103-113.
-
(1995)
J Magn Reson B
, vol.108
, pp. 103-113
-
-
Morrison, C.1
Stanisz, G.2
Henkelman, R.M.3
-
30
-
-
0028954049
-
A model for magnetization transfer in tissues
-
Morrison C, Henkelman RM,. A model for magnetization transfer in tissues. Magn Reson Med 1995; 33: 475-482.
-
(1995)
Magn Reson Med
, vol.33
, pp. 475-482
-
-
Morrison, C.1
Henkelman, R.M.2
-
31
-
-
77649086893
-
Fat-free MRI based on magnetization exchange
-
Chen JH, Le HC, Koutcher JA, Singer S,. Fat-free MRI based on magnetization exchange. Magn Reson Med 2010; 63: 713-718.
-
(2010)
Magn Reson Med
, vol.63
, pp. 713-718
-
-
Chen, J.H.1
Le, H.C.2
Koutcher, J.A.3
Singer, S.4
-
32
-
-
0028317092
-
Magnetization transfer imaging with pulsed off-resonance saturation: Variation in contrast with saturation duty cycle
-
McGowan JC III, Schnall MD, Leigh JS,. Magnetization transfer imaging with pulsed off-resonance saturation: variation in contrast with saturation duty cycle. J Magn Reson Imaging 1994; 4: 79-82.
-
(1994)
J Magn Reson Imaging
, vol.4
, pp. 79-82
-
-
McGowan Iii, J.C.1
Schnall, M.D.2
Leigh, J.S.3
-
33
-
-
24144448806
-
T1, T2 relaxation and magnetization transfer in tissue at 3T
-
Stanisz GJ, Odrobina EE, Pun J, Escaravage M, Graham SJ, Bronskill MJ, Henkelman RM,. T1, T2 relaxation and magnetization transfer in tissue at 3T. Magn Reson Med 2005; 54: 507-512.
-
(2005)
Magn Reson Med
, vol.54
, pp. 507-512
-
-
Stanisz, G.J.1
Odrobina, E.E.2
Pun, J.3
Escaravage, M.4
Graham, S.J.5
Bronskill, M.J.6
Henkelman, R.M.7
-
34
-
-
33746695363
-
2 relaxation in rat brain in vivo
-
DOI 10.1002/mrm.20946
-
de Graaf RA, Brown PB, McIntyre S, Nixon TW, Behar KL, Rothman DL,. High magnetic field water and metabolite proton T1 and T2 relaxation in rat brain in vivo. Magn Reson Med 2006; 56: 386-394. (Pubitemid 44162787)
-
(2006)
Magnetic Resonance in Medicine
, vol.56
, Issue.2
, pp. 386-394
-
-
De Graaf, R.A.1
Brown, P.B.2
McIntyre, S.3
Nixon, T.W.4
Behar, K.L.5
Rothman, D.L.6
-
35
-
-
34249332064
-
1) at high magnetic field strengths
-
DOI 10.1016/j.mri.2006.10.020, PII S0730725X06003687
-
Dobre MC, Ugurbil K, Marjanska M,. Determination of blood longitudinal relaxation time (T1) at high magnetic field strengths. Magn Reson Imaging 2007; 25: 733-735. (Pubitemid 46817806)
-
(2007)
Magnetic Resonance Imaging
, vol.25
, Issue.5
, pp. 733-735
-
-
Dobre, M.C.1
Ugurbil, K.2
Marjanska, M.3
-
36
-
-
15944366135
-
In vivo measurements of T1 relaxation times in mouse brain associated with different modes of systemic administration of manganese chloride
-
DOI 10.1002/jmri.20285
-
Kuo YT, Herlihy AH, So PW, Bhakoo KK, Bell JD,. In vivo measurements of T1 relaxation times in mouse brain associated with different modes of systemic administration of manganese chloride. J Magn Reson Imaging 2005; 21: 334-339. (Pubitemid 40446425)
-
(2005)
Journal of Magnetic Resonance Imaging
, vol.21
, Issue.4
, pp. 334-339
-
-
Kuo, Y.-T.1
Herlihy, A.H.2
So, P.-W.3
Bhakoo, K.K.4
Bell, J.D.5
-
37
-
-
79251566783
-
A simple approach for three-dimensional mapping of baseline cerebrospinal fluid volume fraction
-
Qin Q,. A simple approach for three-dimensional mapping of baseline cerebrospinal fluid volume fraction. Magn Reson Med 2011; 65: 385-391.
-
(2011)
Magn Reson Med
, vol.65
, pp. 385-391
-
-
Qin, Q.1
-
38
-
-
33846807799
-
2O relaxation in vivo
-
DOI 10.1002/mrm.21122
-
Rooney WD, Johnson G, Li X, Cohen ER, Kim SG, Ugurbil K, Springer CS Jr,. Magnetic field and tissue dependencies of human brain longitudinal 1H2O relaxation in vivo. Magn Reson Med 2007; 57: 308-318. (Pubitemid 46214534)
-
(2007)
Magnetic Resonance in Medicine
, vol.57
, Issue.2
, pp. 308-318
-
-
Rooney, W.D.1
Johnson, G.2
Li, X.3
Cohen, E.R.4
Kim, S.-G.5
Ugurbil, K.6
Springer Jr., C.S.7
-
39
-
-
0027457161
-
Comparison of localized proton NMR signals of skeletal muscle and fat tissue in vivo: Two lipid compartments in muscle tissue
-
Schick F, Eismann B, Jung WI, Bongers H, Bunse M, Lutz O,. Comparison of localized proton NMR signals of skeletal muscle and fat tissue in vivo: two lipid compartments in muscle tissue. Magn Reson Med 1993; 29: 158-167. (Pubitemid 23078508)
-
(1993)
Magnetic Resonance in Medicine
, vol.29
, Issue.2
, pp. 158-167
-
-
Schick, F.1
Eismann, B.2
Jung, W.-I.3
Bongers, H.4
Bunse, M.5
Lutz, O.6
-
40
-
-
68049127933
-
Roles of magnetic gradient field and transverse relaxation in distant dipolar field signal
-
Ki Wong C, Zhong J,. Roles of magnetic gradient field and transverse relaxation in distant dipolar field signal. Concepts Magn Reson Part A 2009; 34: 76-90.
-
(2009)
Concepts Magn Reson Part A
, vol.34
, pp. 76-90
-
-
Ki Wong, C.1
Zhong, J.2
-
41
-
-
0027404802
-
Magnetization transfer in cross-linked bovine serum albumin solutions at 200 MHz: A model for tissue
-
Koenig SH, Brown RD III, Ugolini R,. Magnetization transfer in cross-linked bovine serum albumin solutions at 200 MHz: a model for tissue. Magn Reson Med 1993; 29: 311-316. (Pubitemid 23114496)
-
(1993)
Magnetic Resonance in Medicine
, vol.29
, Issue.3
, pp. 311-316
-
-
Koenig, S.H.1
Brown III, R.D.2
Ugolini, R.3
-
42
-
-
66149142268
-
Magnetovaccination as a novel method to assess and quantify dendritic cell tumor antigen capture and delivery to lymph nodes
-
Long CM, van Laarhoven HWM, Bulte JWM, Levitsky HI,. Magnetovaccination as a novel method to assess and quantify dendritic cell tumor antigen capture and delivery to lymph nodes. Cancer Res 2009; 69: 3180-3187.
-
(2009)
Cancer Res
, vol.69
, pp. 3180-3187
-
-
Long, C.M.1
Van Laarhoven, H.W.M.2
Bulte, J.W.M.3
Levitsky, H.I.4
-
43
-
-
60549107250
-
PARACEST MRI with improved temporal resolution
-
Liu G, Ali MM, Yoo B, Griswold MA, Tkach JA, Pagel MD,. PARACEST MRI with improved temporal resolution. Magn Reson Med 2009; 61: 399-408.
-
(2009)
Magn Reson Med
, vol.61
, pp. 399-408
-
-
Liu, G.1
Ali, M.M.2
Yoo, B.3
Griswold, M.A.4
Tkach, J.A.5
Pagel, M.D.6
-
44
-
-
33645062982
-
A simple correction for B1 field errors in magnetization transfer ratio measurements
-
Samson RS, Wheeler-Kingshott CA, Symms MR, Tozer DJ, Tofts PS,. A simple correction for B1 field errors in magnetization transfer ratio measurements. Magn Reson Imaging 2006; 24: 255-263.
-
(2006)
Magn Reson Imaging
, vol.24
, pp. 255-263
-
-
Samson, R.S.1
Wheeler-Kingshott, C.A.2
Symms, M.R.3
Tozer, D.J.4
Tofts, P.S.5
-
45
-
-
55749088003
-
Four pool modeling of proton exchange processes in biological systems in the presence of MRI paramagnetic chemical exchange saturation transfer (PARACEST) agents
-
Li AX, Hudson RHE, Barrett JW, Jones CK, Pasternak SH, Bartha R,. Four pool modeling of proton exchange processes in biological systems in the presence of MRI paramagnetic chemical exchange saturation transfer (PARACEST) agents. Magn Reson Med 2008; 60: 1197-1206.
-
(2008)
Magn Reson Med
, vol.60
, pp. 1197-1206
-
-
Li, A.X.1
Hudson, R.H.E.2
Barrett, J.W.3
Jones, C.K.4
Pasternak, S.H.5
Bartha, R.6
-
46
-
-
21244455602
-
Suppression of lipid artifacts in amide proton transfer imaging
-
DOI 10.1002/mrm.20530
-
Sun PZ, Zhou J, Sun W, Huang J, van Zijl P,. Suppression of lipid artifacts in amide proton transfer imaging. Magn Reson Med 2005; 54: 222-225. (Pubitemid 40898418)
-
(2005)
Magnetic Resonance in Medicine
, vol.54
, Issue.1
, pp. 222-225
-
-
Sun, P.Z.1
Zhou, J.2
Sun, W.3
Huang, J.4
Van Zijl, P.C.M.5
|