-
1
-
-
35648929997
-
Advances in computed radiography systems and their physical imaging characteristics
-
DOI 10.1016/j.crad.2007.07.009, PII S0009926007002899
-
Cowen A. R., Davies A. G., Kengyelics S. M. Advances in computed radiography systems and their physical imaging characteristics. Clin Radiol: 2007; 62 12 1132 1141 (Pubitemid 350019285)
-
(2007)
Clinical Radiology
, vol.62
, Issue.12
, pp. 1132-1141
-
-
Cowen, A.R.1
Davies, A.G.2
Kengyelics, S.M.3
-
2
-
-
72149088235
-
Dose and perceived image quality in chest radiography
-
Veldkamp W. JH, Kroft L. JM, Geleijns J. Dose and perceived image quality in chest radiography. Eur J Radiol: 2009; 72 2 209 217
-
(2009)
Eur J Radiol
, vol.72
, Issue.2
, pp. 209-217
-
-
Veldkamp, W.J.1
Kroft, L.J.2
Geleijns, J.3
-
3
-
-
84869865083
-
Needle image plates compared to conventional CR in chest radiography: Is dose reduction possible
-
Berger-Kulemann V., Pötter-Lang S., Gruber M., et al. Needle image plates compared to conventional CR in chest radiography: is dose reduction possible? Eur J Radiol: 2012; 81 12 4156 4160
-
(2012)
Eur J Radiol
, vol.81
, Issue.12
, pp. 4156-4160
-
-
Berger-Kulemann, V.1
Pötter-Lang, S.2
Gruber, M.3
-
4
-
-
33747825638
-
Depiction of low-contrast detail in digital radiography: Comparison of powder- and needle-structured storage phosphor systems
-
DOI 10.1097/01.rli.0000223765.73182.55, PII 0000442420060700000008
-
Körner M., Treitl M., Schaetzing R., Pfeifer K. J., Reiser M., Wirth S. Depiction of low-contrast detail in digital radiography: comparison of powder- and needle-structured storage phosphor systems. Invest Radiol: 2006; 41 7 593 599 (Pubitemid 44284182)
-
(2006)
Investigative Radiology
, vol.41
, Issue.7
, pp. 593-599
-
-
Korner, M.1
Treitl, M.2
Schaetzing, R.3
Pfeifer, K.-J.4
Reiser, M.5
Wirth, S.6
-
5
-
-
33745108982
-
Direct detector radiography versus dual reading computed radiography: Feasibility of dose reduction in chest radiography
-
DOI 10.1007/s00330-005-0077-1
-
Gruber M., Uffmann M., Weber M., Prokop M., Balassy C., Schaefer-Prokop C. Direct detector radiography versus dual reading computed radiography: feasibility of dose reduction in chest radiography. Eur Radiol: 2006; 16 7 1544 1550 (Pubitemid 43879098)
-
(2006)
European Radiology
, vol.16
, Issue.7
, pp. 1544-1550
-
-
Gruber, M.1
Uffmann, M.2
Weber, M.3
Prokop, M.4
Balassy, C.5
Schaefer-Prokop, C.6
-
6
-
-
49049099386
-
Digital chest radiography: An update on modern technology, dose containment and control of image quality
-
Schaefer-Prokop C., Neitzel U., Venema H. W., Uffmann M., Prokop M. Digital chest radiography: an update on modern technology, dose containment and control of image quality. Eur Radiol: 2008; 18 9 1818 1830
-
(2008)
Eur Radiol
, vol.18
, Issue.9
, pp. 1818-1830
-
-
Schaefer-Prokop, C.1
Neitzel, U.2
Venema, H.W.3
Uffmann, M.4
Prokop, M.5
-
7
-
-
21244454496
-
Status and prospects of digital detector technology for CR and DR
-
DOI 10.1093/rpd/nch532
-
Neitzel U. Status and prospects of digital detector technology for CR and DR. Radiat Prot Dosimetry: 2005; 114 1-3 32 38 (Pubitemid 40883651)
-
(2005)
Radiation Protection Dosimetry
, vol.114
, Issue.1-3
, pp. 32-38
-
-
Neitzel, U.1
-
8
-
-
71849091723
-
DR and CR: Recent advances in technology
-
Schaefer-Prokop C. M., De Boo D. W., Uffmann M., Prokop M. DR and CR: Recent advances in technology. Eur J Radiol: 2009; 72 2 194 201
-
(2009)
Eur J Radiol
, vol.72
, Issue.2
, pp. 194-201
-
-
Schaefer-Prokop, C.M.1
De Boo, D.W.2
Uffmann, M.3
Prokop, M.4
-
9
-
-
31444445988
-
Contrast-detail evaluation and dose assessment of eight digital chest radiography systems in clinical practice
-
DOI 10.1007/s00330-005-2887-6
-
Veldkamp W. JH, Kroft L. JM, Boot M. V., Mertens B. JA, Geleijns J. Contrast-detail evaluation and dose assessment of eight digital chest radiography systems in clinical practice. Eur Radiol: 2006; 16 2 333 341 (Pubitemid 43149632)
-
(2006)
European Radiology
, vol.16
, Issue.2
, pp. 333-341
-
-
Veldkamp, W.J.H.1
Kroft, L.J.M.2
Boot, M.V.3
Mertens, B.J.A.4
Geleijns, J.5
-
10
-
-
84861617158
-
A comparison of digital radiography systems in terms of effective detective quantum efficiency
-
Bertolini M., Nitrosi A., Rivetti S., et al. A comparison of digital radiography systems in terms of effective detective quantum efficiency. Med Phys: 2012; 39 5 2617 2627
-
(2012)
Med Phys
, vol.39
, Issue.5
, pp. 2617-2627
-
-
Bertolini, M.1
Nitrosi, A.2
Rivetti, S.3
-
11
-
-
71849083464
-
Optimizing digital radiography of children
-
Willis C. E. Optimizing digital radiography of children. Eur J Radiol: 2009; 72 2 266 273
-
(2009)
Eur J Radiol
, vol.72
, Issue.2
, pp. 266-273
-
-
Willis, C.E.1
-
12
-
-
0041807573
-
Principles of image processing in digital chest radiography
-
DOI 10.1097/00005382-200307000-00004
-
Prokop M., Neitzel U., Schaefer-Prokop C. Principles of image processing in digital chest radiography. J Thorac Imaging: 2003; 18 3 148 164 (Pubitemid 36899051)
-
(2003)
Journal of Thoracic Imaging
, vol.18
, Issue.3
, pp. 148-164
-
-
Prokop, M.1
Neitzel, U.2
Schaefer-Prokop, C.3
-
13
-
-
0033983980
-
Digital radiography enhancement by nonlinear multiscale processing
-
DOI 10.1118/1.598857
-
Stahl M., Aach T., Dippel S. Digital radiography enhancement by nonlinear multiscale processing. Med Phys: 2000; 27 1 56 65 (Pubitemid 30051911)
-
(2000)
Medical Physics
, vol.27
, Issue.1
, pp. 56-65
-
-
Stahl, M.1
Aach, T.2
Dippel, S.3
-
14
-
-
85076214954
-
Multiscale image contrast amplification (MUSICA)
-
Accessed July 05, 2013.
-
Vuylsteke P., Schoeters E. P. Multiscale image contrast amplification (MUSICA). Proc. SPIE: 1994; 2167 551 560 http://proceedings.spiedigitallibrary. org/proceeding.aspx?articleid=955751. Accessed July 05, 2013.
-
(1994)
Proc. SPIE
, vol.2167
, pp. 551-560
-
-
Vuylsteke, P.1
Schoeters, E.P.2
-
15
-
-
0034879922
-
Characteristics of missed lung cancer on chest radiographs: A French experience
-
DOI 10.1007/s003300000595
-
Monnier-Cholley L., Arrivé L., Porcel A., et al. Characteristics of missed lung cancer on chest radiographs: a French experience. Eur Radiol: 2001; 11 4 597 605 (Pubitemid 32755498)
-
(2001)
European Radiology
, vol.11
, Issue.4
, pp. 597-605
-
-
Monnier-Cholley, L.1
Arrive, L.2
Porcel, A.3
Shehata, K.4
Dahan, H.5
Urban, T.6
Febvre, M.7
Lebeau, B.8
Tubiana, J.M.9
-
16
-
-
0037260023
-
Missed non-small cell lung cancer: Radiographic findings of potentially resectable lesions evident only in retrospect
-
DOI 10.1148/radiol.2261011924
-
Shah P. K., Austin J. HM, White C. S., et al. Missed non-small cell lung cancer: radiographic findings of potentially resectable lesions evident only in retrospect. Radiology: 2003; 226 1 235 241 (Pubitemid 36163935)
-
(2003)
Radiology
, vol.226
, Issue.1
, pp. 235-241
-
-
Shah, P.K.1
Austin, J.H.M.2
White, C.S.3
Patel, P.4
Haramati, L.B.5
Pearson, G.D.N.6
Shiau, M.C.7
Berkmen, Y.M.8
-
17
-
-
81555204323
-
Small lung cancers: Improved detection by use of bone suppression imaging-comparison with dual-energy subtraction chest radiography
-
Li F., Engelmann R., Pesce L. L., Doi K., Metz C. E., Macmahon H. Small lung cancers: improved detection by use of bone suppression imaging-comparison with dual-energy subtraction chest radiography. Radiology: 2011; 261 3 937 949
-
(2011)
Radiology
, vol.261
, Issue.3
, pp. 937-949
-
-
Li, F.1
Engelmann, R.2
Pesce, L.L.3
Doi, K.4
Metz, C.E.5
Macmahon, H.6
-
18
-
-
76149092829
-
Computer-aided volumetry of pulmonary nodules exhibiting ground-glass opacity at MDCT
-
Oda S., Awai K., Murao K., et al. Computer-aided volumetry of pulmonary nodules exhibiting ground-glass opacity at MDCT. AJR Am J Roentgenol: 2010; 194 2 398 406
-
(2010)
AJR Am J Roentgenol
, vol.194
, Issue.2
, pp. 398-406
-
-
Oda, S.1
Awai, K.2
Murao, K.3
-
19
-
-
42449094886
-
Improved detection of small lung cancers with dual-energy subtraction chest radiography
-
DOI 10.2214/AJR.07.2875
-
Li F., Engelmann R., Doi K., MacMahon H. Improved detection of small lung cancers with dual-energy subtraction chest radiography. AJR Am J Roentgenol: 2008; 190 4 886 891 (Pubitemid 351571484)
-
(2008)
American Journal of Roentgenology
, vol.190
, Issue.4
, pp. 886-891
-
-
Li, F.1
Engelmann, R.2
Doi, K.3
MacMahon, H.4
-
20
-
-
34548105734
-
Detection of lung cancer using single-exposure dual-energy subtraction chest radiography
-
DOI 10.1007/s11604-007-0123-9
-
Ide K., Mogami H., Murakami T., Yasuhara Y., Miyagawa M., Mochizuki T. Detection of lung cancer using single-exposure dual-energy subtraction chest radiography. Radiat Med: 2007; 25 5 195 201 (Pubitemid 351928046)
-
(2007)
Radiation Medicine - Medical Imaging and Radiation Oncology
, vol.25
, Issue.5
, pp. 195-201
-
-
Ide, K.1
Mogami, H.2
Murakami, T.3
Yasuhara, Y.4
Miyagawa, M.5
Mochizuki, T.6
-
21
-
-
0347531752
-
Clinical results of Csl-detector-based dual-exposure dual energy in chest radiography
-
DOI 10.1007/s00330-003-1913-9
-
Ricke J., Fischbach F., Freund T., et al. Clinical results of CsI-detector-based dual-exposure dual energy in chest radiography. Eur Radiol: 2003; 13 12 2577 2582 (Pubitemid 37527061)
-
(2003)
European Radiology
, vol.13
, Issue.12
, pp. 2577-2582
-
-
Ricke, J.1
Fischbach, F.2
Freund, T.3
Teichgraber, U.4
Lopez Hanninen, E.5
Rottgen, R.6
Engert, U.7
Eichstadt, H.8
Felix, R.9
-
22
-
-
0028873150
-
Clinical evaluation of pulmonary nodules with single-exposure dual-energy subtraction chest radiography with an iterative noise-reduction algorithm
-
Kido S., Ikezoe J., Naito H., et al. Clinical evaluation of pulmonary nodules with single-exposure dual-energy subtraction chest radiography with an iterative noise-reduction algorithm. Radiology: 1995; 194 2 407 412
-
(1995)
Radiology
, vol.194
, Issue.2
, pp. 407-412
-
-
Kido, S.1
Ikezoe, J.2
Naito, H.3
-
23
-
-
0028082160
-
Conventional chest radiography vs dual-energy computed radiography in the detection and characterization of pulmonary nodules
-
Kelcz F., Zink F. E., Peppler W. W., Kruger D. G., Ergun D. L., Mistretta C. A. Conventional chest radiography vs dual-energy computed radiography in the detection and characterization of pulmonary nodules. AJR Am J Roentgenol: 1994; 162 2 271 278 (Pubitemid 24065418)
-
(1994)
American Journal of Roentgenology
, vol.162
, Issue.2
, pp. 271-278
-
-
Kelcz, F.1
Zink, F.E.2
Peppler, W.W.3
Kruger, D.G.4
Ergun, D.L.5
Mistretta, C.A.6
-
24
-
-
38949108969
-
Single-exposure dual-energy subtraction chest radiography: Detection of pulmonary nodules and masses in clinical practice
-
DOI 10.1007/s00330-007-0758-z
-
Szucs-Farkas Z., Patak M. A., Yuksel-Hatz S., Ruder T., Vock P. Single-exposure dual-energy subtraction chest radiography: detection of pulmonary nodules and masses in clinical practice. Eur Radiol: 2008; 18 1 24 31 (Pubitemid 351217274)
-
(2008)
European Radiology
, vol.18
, Issue.1
, pp. 24-31
-
-
Szucs-Farkas, Z.1
Patak, M.A.2
Yuksel-Hatz, S.3
Ruder, T.4
Vock, P.5
-
25
-
-
49049121586
-
CsI-detector-based dual-exposure dual energy in chest radiography for lung nodule detection: Results of an international multicenter trial
-
Rühl R., Wozniak M. M., Werk M., et al. CsI-detector-based dual-exposure dual energy in chest radiography for lung nodule detection: results of an international multicenter trial. Eur Radiol: 2008; 18 9 1831 1839
-
(2008)
Eur Radiol
, vol.18
, Issue.9
, pp. 1831-1839
-
-
Rühl, R.1
Wozniak, M.M.2
Werk, M.3
-
26
-
-
0024408215
-
Comparison of dual-energy and conventional chest radiography for nodule detection
-
DOI 10.1097/00004424-198911000-00005
-
Ho J. T., Kruger R. A. Comparison of dual-energy and conventional chest radiography for nodule detection. Invest Radiol: 1989; 24 11 861 868 (Pubitemid 20000463)
-
(1989)
Investigative Radiology
, vol.24
, Issue.11
, pp. 861-868
-
-
Ho, J.-T.1
Kruger, R.A.2
-
27
-
-
0344412986
-
Dual-Energy Chest Radiography with a Flat-Panel Digital Detector: Revealing Calcified Chest Abnormalities
-
Fischbach F., Freund T., Röttgen R., Engert U., Felix R., Ricke J. Dual-energy chest radiography with a flat-panel digital detector: revealing calcified chest abnormalities. AJR Am J Roentgenol: 2003; 181 6 1519 1524 (Pubitemid 37466526)
-
(2003)
American Journal of Roentgenology
, vol.181
, Issue.6
, pp. 1519-1524
-
-
Fischbach, F.1
Freund, T.2
Rottgen, R.3
Engert, U.4
Felix, R.5
Ricke, J.6
-
28
-
-
16544384609
-
Digital radiography with dual-energy subtraction: Improved evaluation of cardiac calcification
-
Gilkeson R. C., Novak R. D., Sachs P. Digital radiography with dual-energy subtraction: improved evaluation of cardiac calcification. AJR Am J Roentgenol: 2004; 183 5 1233 1238 (Pubitemid 44210581)
-
(2004)
American Journal of Roentgenology
, vol.183
, Issue.5
, pp. 1233-1238
-
-
Gilkeson, R.C.1
Novak, R.D.2
Sachs, P.3
-
29
-
-
84861303003
-
Assessment of coronary artery calcium using dual-energy subtraction digital radiography
-
Mafi J. N., Fei B., Roble S., et al. Assessment of coronary artery calcium using dual-energy subtraction digital radiography. J Digit Imaging: 2012; 25 1 129 136
-
(2012)
J Digit Imaging
, vol.25
, Issue.1
, pp. 129-136
-
-
Mafi, J.N.1
Fei, B.2
Roble, S.3
-
30
-
-
80052140763
-
Bone images from dual-energy subtraction chest radiography in the detection of rib fractures
-
Szucs-Farkas Z., Lautenschlager K., Flach P. M., et al. Bone images from dual-energy subtraction chest radiography in the detection of rib fractures. Eur J Radiol: 2011; 79 2 e28 e32
-
(2011)
Eur J Radiol
, vol.79
, Issue.2
-
-
Szucs-Farkas, Z.1
Lautenschlager, K.2
Flach, P.M.3
-
31
-
-
33645673568
-
Image-processing technique for suppressing ribs in chest radiographs by means of massive training artificial neural network (MTANN)
-
Suzuki K., Abe H., MacMahon H., Doi K. Image-processing technique for suppressing ribs in chest radiographs by means of massive training artificial neural network (MTANN). IEEE Trans Med Imaging: 2006; 25 4 406 416
-
(2006)
IEEE Trans Med Imaging
, vol.25
, Issue.4
, pp. 406-416
-
-
Suzuki, K.1
Abe, H.2
Macmahon, H.3
Doi, K.4
-
32
-
-
33750701109
-
-
In: Computer Vision Approaches to Medical Image Analysis. Vol 4241 Berlin, Heidelberg Springer
-
Loog M., van Ginneken B. Bony structure suppression in chest radiographs. In: Computer Vision Approaches to Medical Image Analysis. Vol 4241. Berlin, Heidelberg Springer: 2006; 166 177
-
(2006)
Bony Structure Suppression in Chest Radiographs
, pp. 166-177
-
-
Loog, M.1
Van Ginneken, B.2
-
33
-
-
79959562910
-
Lung nodules: Improved detection with software that suppresses the rib and clavicle on chest radiographs
-
Freedman M. T., Lo S. CB, Seibel J. C., Bromley C. M. Lung nodules: improved detection with software that suppresses the rib and clavicle on chest radiographs. Radiology: 2011; 260 1 265 273
-
(2011)
Radiology
, vol.260
, Issue.1
, pp. 265-273
-
-
Freedman, M.T.1
Lo, S.C.2
Seibel, J.C.3
Bromley, C.M.4
-
34
-
-
70449516643
-
Performance of radiologists in detection of small pulmonary nodules on chest radiographs: Effect of rib suppression with a massive-training artificial neural network
-
Oda S., Awai K., Suzuki K., et al. Performance of radiologists in detection of small pulmonary nodules on chest radiographs: effect of rib suppression with a massive-training artificial neural network. AJR Am J Roentgenol: 2009; 193 5 W397 W402s
-
(2009)
AJR Am J Roentgenol
, vol.193
, Issue.5
-
-
Oda, S.1
Awai, K.2
Suzuki, K.3
-
35
-
-
84870368873
-
Improved detection of focal pneumonia by chest radiography with bone suppression imaging
-
Li F., Engelmann R., Pesce L., Armato S. G. III, Macmahon H. Improved detection of focal pneumonia by chest radiography with bone suppression imaging. Eur Radiol: 2012; 22 12 2729 2735
-
(2012)
Eur Radiol
, vol.22
, Issue.12
, pp. 2729-2735
-
-
Li, F.1
Engelmann, R.2
Pesce, L.3
Armato III, G.S.4
Macmahon, H.5
-
36
-
-
0008187609
-
Digital computer determination of a medical diagnostic index directly from chest X-ray images
-
Becker H. C., Nettleton W. J. Jr, Meyers P. H., Sweeney J. W., Nice C. M. Jr. Digital computer determination of a medical diagnostic index directly from chest X-ray images. IEEE Trans Biomed Eng: 1964; 11 67 72
-
(1964)
IEEE Trans Biomed Eng
, vol.11
, pp. 67-72
-
-
Becker, H.C.1
Nettleton, Jr.J.W.2
Meyers, P.H.3
Sweeney, J.W.4
Nice, Jr.M.C.5
-
37
-
-
0008283947
-
Automated computer analysis of radiographic images
-
Meyers P. H., Nice C. M. Jr, Becker H. C., Nettleton W. J. Jr, Sweeney J. W., Meckstroth G. R. Automated computer analysis of radiographic images. Radiology: 1964; 83 1029 1034
-
(1964)
Radiology
, vol.83
, pp. 1029-1034
-
-
Meyers, P.H.1
Nice, Jr.M.C.2
Becker, H.C.3
Nettleton, Jr.J.W.4
Sweeney, J.W.5
Meckstroth, G.R.6
-
38
-
-
0000178127
-
Pattern recognition of chest X-ray images
-
Toriwaki J., Suenaga Y., Negoro T., Fukumura T. Pattern recognition of chest X-ray images. Comput Graph Image Process.: 1973; 2 3/4 252 271
-
(1973)
Comput Graph Image Process.
, vol.2
, Issue.3-4
, pp. 252-271
-
-
Toriwaki, J.1
Suenaga, Y.2
Negoro, T.3
Fukumura, T.4
-
40
-
-
0026629684
-
Image feature analysis of false-positive diagnoses produced by automated detection of lung nodules
-
Matsumoto T., Yoshimura H., Doi K., et al. Image feature analysis of false-positive diagnoses produced by automated detection of lung nodules. Invest Radiol: 1992; 27 8 587 597
-
(1992)
Invest Radiol
, vol.27
, Issue.8
, pp. 587-597
-
-
Matsumoto, T.1
Yoshimura, H.2
Doi, K.3
-
41
-
-
0026655182
-
Potential usefulness of computerized nodule detection in screening programs for lung cancer
-
Matsumoto T., Yoshimura H., Giger M. L., et al. Potential usefulness of computerized nodule detection in screening programs for lung cancer. Invest Radiol: 1992; 27 6 471 475
-
(1992)
Invest Radiol
, vol.27
, Issue.6
, pp. 471-475
-
-
Matsumoto, T.1
Yoshimura, H.2
Giger, M.L.3
-
42
-
-
37349116966
-
Lung cancers missed on chest radiographs: Results obtained with a commercial computer-aided detection program
-
DOI 10.1148/radiol.2461061848
-
Li F., Engelmann R., Metz C. E., Doi K., MacMahon H. Lung cancers missed on chest radiographs: results obtained with a commercial computer-aided detection program. Radiology: 2008; 246 1 273 280 (Pubitemid 350305053)
-
(2008)
Radiology
, vol.246
, Issue.1
, pp. 273-280
-
-
Li, F.1
Engelmann, R.2
Metz, C.E.3
Doi, K.4
MacMahon, H.5
-
43
-
-
67650080471
-
Use of a computer-aided detection system to detect missed lung cancer at chest radiography
-
White C. S., Flukinger T., Jeudy J., Chen J. J. Use of a computer-aided detection system to detect missed lung cancer at chest radiography. Radiology: 2009; 252 1 273 281
-
(2009)
Radiology
, vol.252
, Issue.1
, pp. 273-281
-
-
White, C.S.1
Flukinger, T.2
Jeudy, J.3
Chen, J.J.4
-
44
-
-
84879924692
-
The effect of computer-aided detection on radiologist performance in the detection of lung cancers previously missed on a chest radiograph
-
Kligerman S., Cai L., White C. S. The effect of computer-aided detection on radiologist performance in the detection of lung cancers previously missed on a chest radiograph. J Thorac Imaging: 2013; 28 4 244 252
-
(2013)
J Thorac Imaging
, vol.28
, Issue.4
, pp. 244-252
-
-
Kligerman, S.1
Cai, L.2
White, C.S.3
-
45
-
-
0033986483
-
Development of a digital image database for chest radiographs with and without a lung nodule: Receiver operating characteristic analysis of radiologists' detection of pulmonary nodules
-
Shiraishi J., Katsuragawa S., Ikezoe J., et al. Development of a digital image database for chest radiographs with and without a lung nodule: receiver operating characteristic analysis of radiologists' detection of pulmonary nodules. AJR Am J Roentgenol: 2000; 174 1 71 74 (Pubitemid 30030212)
-
(2000)
American Journal of Roentgenology
, vol.174
, Issue.1
, pp. 71-74
-
-
Shiraishi, J.1
Katsuragawa, S.2
Ikezoe, J.3
Matsumoto, T.4
Kobayashi, T.5
Komatsu, K.-I.6
Matsui, M.7
Fujita, H.8
Kodera, Y.9
Doi, K.10
-
46
-
-
0031732622
-
Computer-aided diagnoses: Automatic detection of lung nodules
-
DOI 10.1118/1.598388
-
Carreira M. J., Cabello D., Penedo M. G., Mosquera A. Computer-aided diagnoses: automatic detection of lung nodules. Med Phys: 1998; 25 10 1998 2006 (Pubitemid 28485224)
-
(1998)
Medical Physics
, vol.25
, Issue.10
, pp. 1998-2006
-
-
Carreira, M.J.1
Cabello, D.2
Penedo, M.G.3
Mosquera, A.4
-
48
-
-
1442264195
-
Neural networks for computer-aided diagnosis: Detection of lung nodules in chest radiograms
-
Coppini G., Diciotti S., Falchini M., Villari N., Valli G. Neural networks for computer-aided diagnosis: detection of lung nodules in chest radiograms. IEEE Trans Inf Technol Biomed: 2003; 7 4 344 357
-
(2003)
IEEE Trans Inf Technol Biomed
, vol.7
, Issue.4
, pp. 344-357
-
-
Coppini, G.1
Diciotti, S.2
Falchini, M.3
Villari, N.4
Valli, G.5
-
49
-
-
84893276439
-
Computer-aided diagnosis as a second reader for nodule detection in chest radiographs versus single and double reading
-
Presented at
-
Schilham A. MR, van Ginneken B. Computer-aided diagnosis as a second reader for nodule detection in chest radiographs versus single and double reading. Presented at: European Congress of Radiology; 2005; 205
-
(2005)
European Congress of Radiology
, pp. 205
-
-
Schilham, A.M.1
Van Ginneken, B.2
-
50
-
-
33845567879
-
A fully automated method for lung nodule detection from postero-anterior chest radiographs
-
DOI 10.1109/TMI.2006.884198
-
Campadelli P., Casiraghi E., Artioli D. A fully automated method for lung nodule detection from postero-anterior chest radiographs. IEEE Trans Med Imaging: 2006; 25 12 1588 1603 (Pubitemid 44936708)
-
(2006)
IEEE Transactions on Medical Imaging
, vol.25
, Issue.12
, pp. 1588-1603
-
-
Campadelli, P.1
Casiraghi, E.2
Artioli, D.3
-
51
-
-
43549123731
-
Performance analysis of a new computer aided detection system for identifying lung nodules on chest radiographs
-
Hardie R. C., Rogers S. K., Wilson T., Rogers A. Performance analysis of a new computer aided detection system for identifying lung nodules on chest radiographs. Med Image Anal: 2008; 12 3 240 258
-
(2008)
Med Image Anal
, vol.12
, Issue.3
, pp. 240-258
-
-
Hardie, R.C.1
Rogers, S.K.2
Wilson, T.3
Rogers, A.4
-
53
-
-
79953663112
-
Development and evaluation of a computer-aided diagnostic scheme for lung nodule detection in chest radiographs by means of two-stage nodule enhancement with support vector classification
-
Chen S., Suzuki K., MacMahon H. Development and evaluation of a computer-aided diagnostic scheme for lung nodule detection in chest radiographs by means of two-stage nodule enhancement with support vector classification. Med Phys: 2011; 38 4 1844 1858
-
(2011)
Med Phys
, vol.38
, Issue.4
, pp. 1844-1858
-
-
Chen, S.1
Suzuki, K.2
Macmahon, H.3
-
54
-
-
84858282633
-
Assessing the use of digital radiography and a real-time interactive pulmonary nodule analysis system for large population lung cancer screening
-
Xu Y., Ma D., He W. Assessing the use of digital radiography and a real-time interactive pulmonary nodule analysis system for large population lung cancer screening. Eur J Radiol: 2012; 81 4 e451 e456
-
(2012)
Eur J Radiol
, vol.81
, Issue.4
-
-
Xu, Y.1
Ma, D.2
He, W.3
-
55
-
-
41949094161
-
Evaluation of a Real-time Interactive Pulmonary Nodule Analysis System on Chest Digital Radiographic Images. A Prospective Study
-
DOI 10.1016/j.acra.2008.01.018, PII S1076633208000524
-
van Beek E. JR, Mullan B., Thompson B. Evaluation of a real-time interactive pulmonary nodule analysis system on chest digital radiographic images: a prospective study. Acad Radiol: 2008; 15 5 571 575 (Pubitemid 351509767)
-
(2008)
Academic Radiology
, vol.15
, Issue.5
, pp. 571-575
-
-
Van Beek, E.J.R.1
Mullan, B.2
Thompson, B.3
-
56
-
-
46849110821
-
Usefulness of computer-aided diagnosis schemes for vertebral fractures and lung nodules on chest radiographs
-
DOI 10.2214/AJR.07.3091
-
Kasai S., Li F., Shiraishi J., Doi K. Usefulness of computer-aided diagnosis schemes for vertebral fractures and lung nodules on chest radiographs. AJR Am J Roentgenol: 2008; 191 1 260 265 (Pubitemid 351955176)
-
(2008)
American Journal of Roentgenology
, vol.191
, Issue.1
, pp. 260-265
-
-
Kasai, S.1
Li, F.2
Shiraishi, J.3
Doi, K.4
-
57
-
-
33745815977
-
Computer-aided Diagnosis for the Detection and Classification of Lung Cancers on Chest Radiographs. ROC Analysis of Radiologists' Performance
-
DOI 10.1016/j.acra.2006.04.007, PII S1076633206002595
-
Shiraishi J., Abe H., Li F., Engelmann R., MacMahon H., Doi K. Computer-aided diagnosis for the detection and classification of lung cancers on chest radiographs ROC analysis of radiologists' performance. Acad Radiol: 2006; 13 8 995 1003 (Pubitemid 44037456)
-
(2006)
Academic Radiology
, vol.13
, Issue.8
, pp. 995-1003
-
-
Shiraishi, J.1
Abe, H.2
Li, F.3
Engelmann, R.4
MacMahon, H.5
Doi, K.6
-
58
-
-
33845435545
-
Computer-aided nodule detection on digital chest radiography: Validation test on consecutive T1 cases of resectable lung cancer
-
DOI 10.1007/s10278-006-0626-4
-
Sakai S., Soeda H., Takahashi N., et al. Computer-aided nodule detection on digital chest radiography: validation test on consecutive T1 cases of resectable lung cancer. J Digit Imaging: 2006; 19 4 376 382 (Pubitemid 44935229)
-
(2006)
Journal of Digital Imaging
, vol.19
, Issue.4
, pp. 376-382
-
-
Sakai, S.1
Soeda, H.2
Takahashi, N.3
Okafuji, T.4
Yoshitake, T.5
Yabuuchi, H.6
Yoshino, I.7
Yamamoto, K.8
Honda, H.9
Doi, K.10
-
59
-
-
9144248947
-
Improved detection of lung nodules on chest radiographs using a commercial computer-aided diagnosis system
-
Kakeda S., Moriya J., Sato H., et al. Improved detection of lung nodules on chest radiographs using a commercial computer-aided diagnosis system. AJR Am J Roentgenol: 2004; 182 2 505 510 (Pubitemid 38116601)
-
(2004)
American Journal of Roentgenology
, vol.182
, Issue.2
, pp. 505-510
-
-
Kakeda, S.1
Moriya, J.2
Sato, H.3
Aoki, T.4
Watanabe, H.5
Nakata, H.6
Oda, N.7
Katsuragawa, S.8
Yamamoto, K.9
Doi, K.10
-
60
-
-
80055109900
-
Computer-aided detection of small pulmonary nodules in chest radiographs: An observer study
-
De Boo D. W., Uffmann M., Weber M., et al. Computer-aided detection of small pulmonary nodules in chest radiographs: an observer study. Acad Radiol: 2011; 18 12 1507 1514
-
(2011)
Acad Radiol
, vol.18
, Issue.12
, pp. 1507-1514
-
-
De Boo, D.W.1
Uffmann, M.2
Weber, M.3
-
61
-
-
77958550618
-
Computer-aided detection of lung cancer on chest radiographs: Effect on observer performance
-
de Hoop B., De Boo D. W., Gietema H. A., et al. Computer-aided detection of lung cancer on chest radiographs: effect on observer performance. Radiology: 2010; 257 2 532 540
-
(2010)
Radiology
, vol.257
, Issue.2
, pp. 532-540
-
-
De Hoop, B.1
De Boo, D.W.2
Gietema, H.A.3
-
62
-
-
84866253416
-
Computer-aided detection of malignant lung nodules on chest radiographs: Effect on observers' performance
-
Lee K. H., Goo J. M., Park C. M., Lee H. J., Jin K. N. Computer-aided detection of malignant lung nodules on chest radiographs: effect on observers' performance. KJR: 2012; 13 5 564 571
-
(2012)
KJR
, vol.13
, Issue.5
, pp. 564-571
-
-
Lee, K.H.1
Goo, J.M.2
Park, C.M.3
Lee, H.J.4
Jin, K.N.5
-
63
-
-
79959587512
-
A comparison of follow-up recommendations by chest radiologists, general radiologists, and pulmonologists using computer-aided detection to assess radiographs for actionable pulmonary nodules
-
Meziane M., Obuchowski N. A., Lababede O., Lieber M. L., Philips M., Mazzone P. A comparison of follow-up recommendations by chest radiologists, general radiologists, and pulmonologists using computer-aided detection to assess radiographs for actionable pulmonary nodules. AJR Am J Roentgenol: 2011; 196 5 W542 W549
-
(2011)
AJR Am J Roentgenol
, vol.196
, Issue.5
-
-
Meziane, M.1
Obuchowski, N.A.2
Lababede, O.3
Lieber, M.L.4
Philips, M.5
Mazzone, P.6
-
64
-
-
77149124587
-
Dual energy subtraction digital radiography improves performance of a next generation computer-aided detection program
-
Balkman J. D., Mehandru S., DuPont E., Novak R. D., Gilkeson R. C. Dual energy subtraction digital radiography improves performance of a next generation computer-aided detection program. J Thorac Imaging: 2010; 25 1 41 47
-
(2010)
J Thorac Imaging
, vol.25
, Issue.1
, pp. 41-47
-
-
Balkman, J.D.1
Mehandru, S.2
Dupont, E.3
Novak, R.D.4
Gilkeson, R.C.5
-
65
-
-
77952098839
-
Improved detection of pulmonary nodules on energy-subtracted chest radiographs with a commercial computer-aided diagnosis software: Comparison with human observers
-
Szucs-Farkas Z., Patak M. A., Yuksel-Hatz S., Ruder T., Vock P. Improved detection of pulmonary nodules on energy-subtracted chest radiographs with a commercial computer-aided diagnosis software: comparison with human observers. Eur Radiol: 2010; 20 6 1289 1296
-
(2010)
Eur Radiol
, vol.20
, Issue.6
, pp. 1289-1296
-
-
Szucs-Farkas, Z.1
Patak, M.A.2
Yuksel-Hatz, S.3
Ruder, T.4
Vock, P.5
-
66
-
-
84880174377
-
A comparison of computer-aided detection (CAD) effectiveness in pulmonary nodule identification using different methods of bone suppression in chest radiographs
-
Novak R. D., Novak N. J., Gilkeson R., Mansoori B., Aandal G. E. A comparison of computer-aided detection (CAD) effectiveness in pulmonary nodule identification using different methods of bone suppression in chest radiographs. J Digit Imaging: 2013; 26 4 651 656
-
(2013)
J Digit Imaging
, vol.26
, Issue.4
, pp. 651-656
-
-
Novak, R.D.1
Novak, N.J.2
Gilkeson, R.3
Mansoori, B.4
Aandal, G.E.5
-
67
-
-
84879299885
-
Comparison of dual-energy subtraction and electronic bone suppression combined with computer-aided detection on chest radiographs: Effect on human observers' performance in nodule detection
-
Szucs-Farkas Z., Schick A., Cullmann J. L., et al. Comparison of dual-energy subtraction and electronic bone suppression combined with computer-aided detection on chest radiographs: effect on human observers' performance in nodule detection. AJR Am J Roentgenol: 2013; 200 5 1006 1013
-
(2013)
AJR Am J Roentgenol
, vol.200
, Issue.5
, pp. 1006-1013
-
-
Szucs-Farkas, Z.1
Schick, A.2
Cullmann, J.L.3
-
68
-
-
84893227819
-
Computer aided detection helps radiologists to detect pulmonary nodules in chest radiographs, when having bone suppressed images available
-
Presented at
-
Schalekamp S., van Ginneken B., Koedam E., et al. Computer aided detection helps radiologists to detect pulmonary nodules in chest radiographs, when having bone suppressed images available. Presented at: Annual Meeting of the Radiological Society of North America; 2012
-
(2012)
Annual Meeting of the Radiological Society of North America
-
-
Schalekamp, S.1
Van Ginneken, B.2
Koedam, E.3
-
69
-
-
77952253563
-
Global and local multi-valued dissimilarity-based classification: Application to computer-aided detection of tuberculosis
-
Arzhaeva Y., Hogeweg L., de Jong P. A., Viergever M. A., van Ginneken B. Global and local multi-valued dissimilarity-based classification: application to computer-aided detection of tuberculosis. Med Image Comput Comput Assist Interv: 2009; 12 2 724 731
-
(2009)
Med Image Comput Comput Assist Interv
, vol.12
, Issue.2
, pp. 724-731
-
-
Arzhaeva, Y.1
Hogeweg, L.2
De Jong, P.A.3
Viergever, M.A.4
Van Ginneken, B.5
-
70
-
-
0036476995
-
Automatic detection of abnormalities in chest radiographs using local texture analysis
-
DOI 10.1109/42.993132, PII S0278006202029427
-
van Ginneken B., Katsuragawa S., ter Haar Romeny B. M., Doi K., Viergever M. A. Automatic detection of abnormalities in chest radiographs using local texture analysis. IEEE Trans Med Imaging: 2002; 21 2 139 149 (Pubitemid 34466427)
-
(2002)
IEEE Transactions on Medical Imaging
, vol.21
, Issue.2
, pp. 139-149
-
-
Van Ginneken, B.1
Katsuragawa, S.2
Ter Haar Romeny, B.M.3
Doi, K.4
Viergever, M.A.5
-
71
-
-
84894043846
-
Performance evaluation of automatic chest radiograph reading for detection of tuberculosis (TB): A comparative study with clinical officers and certified readers on TB suspects in sub-Saharan Africa
-
Presented at
-
Maduskar P., Hogeweg L., Ayles H., van Ginneken B. Performance evaluation of automatic chest radiograph reading for detection of tuberculosis (TB): a comparative study with clinical officers and certified readers on TB suspects in sub-Saharan Africa. Presented at: European Congress of Radiology; 2013
-
(2013)
European Congress of Radiology
-
-
Maduskar, P.1
Hogeweg, L.2
Ayles, H.3
Van Ginneken, B.4
-
72
-
-
0025224132
-
Potential usefulness of an artificial neural network for differential diagnosis of interstitial lung diseases: Pilot study
-
Asada N., Doi K., MacMahon H., et al. Potential usefulness of an artificial neural network for differential diagnosis of interstitial lung diseases: pilot study. Radiology: 1990; 177 3 857 860
-
(1990)
Radiology
, vol.177
, Issue.3
, pp. 857-860
-
-
Asada, N.1
Doi, K.2
Macmahon, H.3
-
73
-
-
36649001129
-
Computer-aided detection of interstitial abnormalities in chest radiographs using a reference standard based on computed tomography
-
DOI 10.1118/1.2795672
-
Arzhaeva Y., Prokop M., Tax D. MJ, De Jong P. A., Schaefer-Prokop C. M., van Ginneken B. Computer-aided detection of interstitial abnormalities in chest radiographs using a reference standard based on computed tomography. Med Phys: 2007; 34 12 4798 4809 (Pubitemid 350197719)
-
(2007)
Medical Physics
, vol.34
, Issue.12
, pp. 4798-4809
-
-
Arzhaeva, Y.1
Prokop, M.2
Tax, D.M.J.3
De Jong, P.A.4
Schaefer-Prokop, C.M.5
Ginneken, B.V.6
-
74
-
-
0347993887
-
Artificial Neural Networks (ANNs) for Differential Diagnosis of Interstitial Lung Disease: Results of a Simulation Test with Actual Clinical Cases
-
DOI 10.1016/S1076-6332(03)00572-5
-
Abe H., Ashizawa K., Li F., et al. Artificial neural networks (ANNs) for differential diagnosis of interstitial lung disease: results of a simulation test with actual clinical cases. Acad Radiol: 2004; 11 1 29 37 (Pubitemid 38029817)
-
(2004)
Academic Radiology
, vol.11
, Issue.1
, pp. 29-37
-
-
Abe, H.1
Ashizawa, K.2
Li, F.3
Matsuyama, N.4
Fukushima, A.5
Shiraishi, J.6
MacMahon, H.7
Doi, K.8
-
75
-
-
84893268603
-
Rib suppression in chest radiographs to improve classification of textural abnormalities
-
Accessed July 05, 2013.
-
Hogeweg L., Mol C., de Jong P. A., van Ginneken B. Rib suppression in chest radiographs to improve classification of textural abnormalities. Proc. SPIE: 2010; 7624 76240Y1 76240Y6 http://proceedings.spiedigitallibrary.org/ proceeding.aspx?articleid=747829. Accessed July 05, 2013.
-
(2010)
Proc. SPIE
, vol.7624
-
-
Hogeweg, L.1
Mol, C.2
De Jong, P.A.3
Van Ginneken, B.4
-
76
-
-
84878381764
-
Improved texture analysis for automatic detection of Tuberculosis (TB) on Chest Radiographs with Bone Suppression images
-
p. 86700H-86700H-6. Accessed July 05, 2013.
-
Maduskar P., Hogeweg L., Philipsen R., Schalekamp S., van Ginneken B. Improved texture analysis for automatic detection of Tuberculosis (TB) on Chest Radiographs with Bone Suppression images. Proc. SPIE: 2013; 8670:p. 86700H-86700H-6. http://proceedings.spiedigitallibrary.org/proceeding.aspx? articleid=1669548. Accessed July 05, 2013.
-
(2013)
Proc. SPIE
, vol.8670
-
-
Maduskar, P.1
Hogeweg, L.2
Philipsen, R.3
Schalekamp, S.4
Van Ginneken, B.5
-
77
-
-
80053647853
-
Computer-aided recognition of emphysema on digital chest radiography
-
Miniati M., Coppini G., Monti S., Bottai M., Paterni M., Ferdeghini E. M. Computer-aided recognition of emphysema on digital chest radiography. Eur J Radiol: 2011; 80 2 e169 e175
-
(2011)
Eur J Radiol
, vol.80
, Issue.2
-
-
Miniati, M.1
Coppini, G.2
Monti, S.3
Bottai, M.4
Paterni, M.5
Ferdeghini, E.M.6
-
78
-
-
84871508045
-
A computer-aided diagnosis approach for emphysema recognition in chest radiography
-
Coppini G., Miniati M., Monti S., Paterni M., Favilla R., Ferdeghini E. M. A computer-aided diagnosis approach for emphysema recognition in chest radiography. Med Eng Phys: 2013; 35 1 63 73
-
(2013)
Med Eng Phys
, vol.35
, Issue.1
, pp. 63-73
-
-
Coppini, G.1
Miniati, M.2
Monti, S.3
Paterni, M.4
Favilla, R.5
Ferdeghini, E.M.6
-
79
-
-
0026806940
-
Image feature analysis and computer-aided diagnosis in digital radiography: Automated detection of pneumothorax in chest images
-
Sanada S., Doi K., MacMahon H. Image feature analysis and computer-aided diagnosis in digital radiography: automated detection of pneumothorax in chest images. Med Phys: 1992; 19 5 1153 1160
-
(1992)
Med Phys
, vol.19
, Issue.5
, pp. 1153-1160
-
-
Sanada, S.1
Doi, K.2
Macmahon, H.3
-
80
-
-
35248867498
-
Semi-automated location identification of catheters in digital chest radiographs
-
p. 65141O-65141O-9. Accessed July 11, 2013.
-
Keller B. M., Reeves A. P., Cham M. D., Henschke C. I., Yankelevitz D. F. Semi-automated location identification of catheters in digital chest radiographs. Proc. SPIE: 2007; 6514:p. 65141O-65141O-9. http://proceedings. spiedigitallibrary.org/proceeding.aspx?articleid=1299820. Accessed July 11, 2013.
-
(2007)
Proc. SPIE
, vol.6514
-
-
Keller, B.M.1
Reeves, A.P.2
Cham, M.D.3
Henschke, C.I.4
Yankelevitz, D.F.5
-
81
-
-
79955775845
-
Catheter detection and classification on chest radiographs: An automated prototype computer-aided detection (CAD) system for radiologists
-
p. 796333 Accessed July 11, 2013.
-
Ramakrishna B., Brown M., Goldin J., Cagnon C., Enzmann D. Catheter detection and classification on chest radiographs: an automated prototype computer-aided detection (CAD) system for radiologists. Proc. SPIE: 2011; 7963:p. 796333 http://proceedings.spiedigitallibrary.org/proceeding.aspx? articleid=725597. Accessed July 11, 2013.
-
(2011)
Proc. SPIE
, vol.7963
-
-
Ramakrishna, B.1
Brown, M.2
Goldin, J.3
Cagnon, C.4
Enzmann, D.5
-
82
-
-
84874874928
-
An improved automatic computer aided tube detection and labeling system on chest radiographs
-
p. 83150R-83150R-7 Accessed July 11, 2013.
-
Ramakrishna B., Brown M., Goldin J., Cagnon C., Enzmann D. An improved automatic computer aided tube detection and labeling system on chest radiographs. Proc. SPIE: 2012; 8315:p. 83150R-83150R-7 http://proceedings. spiedigitallibrary.org/proceeding.aspx?articleid=1285261. Accessed July 11, 2013.
-
(2012)
Proc. SPIE
, vol.8315
-
-
Ramakrishna, B.1
Brown, M.2
Goldin, J.3
Cagnon, C.4
Enzmann, D.5
-
83
-
-
84893324937
-
Application of digital image change detection to diagnosis and follow-up of cancer involving the lungs
-
Accessed July 11, 2013.
-
Kinsey J., Vannelli B., Fontana R., Miller W., Johnson S., Gilbert B. Application of digital image change detection to diagnosis and follow-up of cancer involving the lungs. Proc. SPIE: 1976; 0070 99 112. http://proceedings. spiedigitallibrary.org/proceeding.aspx?articleid=1225514. Accessed July 11, 2013.
-
(1976)
Proc. SPIE
, vol.70
, pp. 99-112
-
-
Kinsey, J.1
Vannelli, B.2
Fontana, R.3
Miller, W.4
Johnson, S.5
Gilbert, B.6
-
84
-
-
0028218947
-
Digital image subtraction of temporally sequential chest images for detection of interval change
-
DOI 10.1118/1.597308
-
Kano A., Doi K., MacMahon H., Hassell D. D., Giger M. L. Digital image subtraction of temporally sequential chest images for detection of interval change. Med Phys: 1994; 21 3 453 461 (Pubitemid 24094961)
-
(1994)
Medical Physics
, vol.21
, Issue.3
, pp. 453-461
-
-
Kano, A.1
Doi, K.2
MacMahon, H.3
Hassell, D.D.4
Giger, M.L.5
-
85
-
-
0033216512
-
Comparison of the quality of temporal subtraction images obtained with manual and automated methods of digital chest radiography
-
Katsuragawa S., Tagashira H., Li Q., MacMahon H., Doi K. Comparison of the quality of temporal subtraction images obtained with manual and automated methods of digital chest radiography. J Digit Imaging: 1999; 12 4 166 172 (Pubitemid 30519378)
-
(1999)
Journal of Digital Imaging
, vol.12
, Issue.4
, pp. 166-172
-
-
Katsuragawa, S.1
Tagashira, H.2
Li, Q.3
MacMahon, H.4
Doi, K.5
-
86
-
-
33744781576
-
Temporal subtraction of dual-energy chest radiographs
-
DOI 10.1118/1.2163387
-
Armato S. G. III, Doshi D. J., Engelmann R., Caligiuri P., MacMahon H. Temporal subtraction of dual-energy chest radiographs. Med Phys: 2006; 33 6 1911 1919 (Pubitemid 43830279)
-
(2006)
Medical Physics
, vol.33
, Issue.6
, pp. 1911-1919
-
-
Armato III, S.G.1
Doshi, D.J.2
Engelmann, R.3
Caligiuri, P.4
MacMahon, H.5
-
87
-
-
0031024014
-
Digital chest radiography: Effect of temporal subtraction images on detection accuracy
-
Difazio M. C., MacMahon H., Xu X. W., et al. Digital chest radiography: effect of temporal subtraction images on detection accuracy. Radiology: 1997; 202 2 447 452 (Pubitemid 27051741)
-
(1997)
Radiology
, vol.202
, Issue.2
, pp. 447-452
-
-
Difazio, M.C.1
MacMahon, H.2
Xu, X.-W.3
Tsai, P.4
Shiraishi, J.5
Armato III, S.G.6
Doi, K.7
-
88
-
-
0034823999
-
ROC analysis of detection of metastatic pulmonary nodules on digital chest radiographs with temporal subtraction
-
DOI 10.1016/S1076-6332(03)80766-3
-
Uozumi T., Nakamura K., Watanabe H., Nakata H., Katsuragawa S., Doi K. ROC analysis of detection of metastatic pulmonary nodules on digital chest radiographs with temporal subtraction. Acad Radiol: 2001; 8 9 871 878 (Pubitemid 32822317)
-
(2001)
Academic Radiology
, vol.8
, Issue.9
, pp. 871-878
-
-
Uozumi, T.1
Nakamura, K.2
Watanabe, H.3
Nakata, H.4
Katsuragawa, S.5
Doi, K.6
-
89
-
-
0036068724
-
Temporal subtraction for the detection of hazy pulmonary opacities on chest radiography
-
Tsubamoto M., Johkoh T., Kozuka T., et al. Temporal subtraction for the detection of hazy pulmonary opacities on chest radiography. AJR Am J Roentgenol: 2002; 179 2 467 471 (Pubitemid 34785654)
-
(2002)
American Journal of Roentgenology
, vol.179
, Issue.2
, pp. 467-471
-
-
Tsubamoto, M.1
Johkoh, T.2
Kozuka, T.3
Tomiyama, N.4
Hamada, S.5
Honda, O.6
Mihara, N.7
Koyama, M.8
Maeda, M.9
Nakamura, H.10
Fujiwara, K.11
-
90
-
-
11144355339
-
Improved detection of lung cancer arising in diffuse lung diseases on chest radiographs using temporal subtraction
-
DOI 10.1016/S1076-6332(03)00820-1
-
Okazaki H., Nakamura K., Watanabe H., et al. Improved detection of lung cancer arising in diffuse lung diseases on chest radiographs using temporal subtraction. Acad Radiol: 2004; 11 5 498 505 (Pubitemid 38533853)
-
(2004)
Academic Radiology
, vol.11
, Issue.5
, pp. 498-505
-
-
Okazaki, H.1
Nakamura, K.2
Watanabe, H.3
Matsuki, Y.4
Uozumi, T.5
Kakeda, S.6
Kamada, K.7
Oda, N.8
Nakata, H.9
Katsuragawa, S.10
Doi, K.11
-
91
-
-
0036082583
-
Improved detection of lung nodules by using a temporal subtraction technique
-
Kakeda S., Nakamura K., Kamada K., et al. Improved detection of lung nodules by using a temporal subtraction technique. Radiology: 2002; 224 1 145 151 (Pubitemid 34680386)
-
(2002)
Radiology
, vol.224
, Issue.1
, pp. 145-151
-
-
Kakeda, S.1
Nakamura, K.2
Kamada, K.3
Watanabe, H.4
Nakata, H.5
Katsuragawa, S.6
Doi, K.7
-
92
-
-
0036099335
-
Temporal subtraction for detection of solitary pulmonary nodules on chest radiographs: Evaluation of a commercially available computer-aided diagnosis system
-
Johkoh T., Kozuka T., Tomiyama N., et al. Temporal subtraction for detection of solitary pulmonary nodules on chest radiographs: evaluation of a commercially available computer-aided diagnosis system. Radiology: 2002; 223 3 806 811 (Pubitemid 34547601)
-
(2002)
Radiology
, vol.223
, Issue.3
, pp. 806-811
-
-
Johkoh, T.1
Kozuka, T.2
Tomiyama, N.3
Hamada, S.4
Honda, O.5
Mihara, N.6
Koyama, M.7
Tsubamoto, M.8
Maeda, M.9
Nakamura, H.10
Saki, H.11
Fujiwara, K.12
-
93
-
-
79251619725
-
Clinical usefulness of temporal subtraction method in screening digital chest radiography with a mobile computed radiography system
-
Sasaki Y., Abe K., Tabei M., Katsuragawa S., Kurosaki A., Matsuoka S. Clinical usefulness of temporal subtraction method in screening digital chest radiography with a mobile computed radiography system. Radiological Phys Technol: 2011; 4 1 84 90
-
(2011)
Radiological Phys Technol
, vol.4
, Issue.1
, pp. 84-90
-
-
Sasaki, Y.1
Abe, K.2
Tabei, M.3
Katsuragawa, S.4
Kurosaki, A.5
Matsuoka, S.6
-
94
-
-
33750293407
-
Effect of temporal subtraction technique on interpretation time and diagnostic accuracy of chest radiography
-
DOI 10.2214/AJR.05.1270
-
Kakeda S., Kamada K., Hatakeyama Y., et al. Effect of temporal subtraction technique on interpretation time and diagnostic accuracy of chest radiography. AJR Am J Roentgenol: 2006; 187 5 1253 1259 (Pubitemid 44630829)
-
(2006)
American Journal of Roentgenology
, vol.187
, Issue.5
, pp. 1253-1259
-
-
Kakeda, S.1
Kamada, K.2
Hatakeyama, Y.3
Aoki, T.4
Korogi, Y.5
Katsuragawa, S.6
Doi, K.7
-
95
-
-
84893265745
-
-
Accessed June 11, 2013
-
Technologies R.. Deltaview Reader Study; 2011; http://www.accessdata.fda. gov/cdrh-docs/pdf11/K111776.pdf. Accessed June 11, 2013.
-
(2011)
Deltaview Reader Study
-
-
Technologies, R.1
-
96
-
-
84859953744
-
Usefulness of computerized method for lung nodule detection on digital chest radiographs using similar subtraction images from different patients
-
Aoki T., Oda N., Yamashita Y., Yamamoto K., Korogi Y. Usefulness of computerized method for lung nodule detection on digital chest radiographs using similar subtraction images from different patients. Eur J Radiol: 2012; 81 5 1062 1067
-
(2012)
Eur J Radiol
, vol.81
, Issue.5
, pp. 1062-1067
-
-
Aoki, T.1
Oda, N.2
Yamashita, Y.3
Yamamoto, K.4
Korogi, Y.5
|