메뉴 건너뛰기




Volumn 41, Issue 7, 2006, Pages 593-599

Depiction of low-contrast detail in digital radiography: Comparison of powder- and needle-structured storage phosphor systems

Author keywords

Digital radiography; Low contrast; Needle image plate; Storage phosphor

Indexed keywords

ARTICLE; CALCULATION; COMPUTER ASSISTED RADIOGRAPHY; CONTRAST ENHANCEMENT; DIGITAL RADIOGRAPHY; IMAGING SYSTEM; PARAMETER; PHANTOM; PRIORITY JOURNAL; SIMULATION; STATISTICAL SIGNIFICANCE; STUDENT T TEST;

EID: 33747825638     PISSN: 00209996     EISSN: None     Source Type: Journal    
DOI: 10.1097/01.rli.0000223765.73182.55     Document Type: Article
Times cited : (21)

References (27)
  • 1
    • 23844489226 scopus 로고    scopus 로고
    • Reflective and transmissive CR. ScanHead technology on needle image plates
    • Frankenberger J, Mair S, Herrmann C, et al. Reflective and transmissive CR. ScanHead technology on needle image plates. Proc SPIE. 2005;5745:499-510.
    • (2005) Proc SPIE , vol.5745 , pp. 499-510
    • Frankenberger, J.1    Mair, S.2    Herrmann, C.3
  • 2
    • 0033625293 scopus 로고    scopus 로고
    • A new needle-crystalline computed radiography detector
    • Leblans P, Struye L, Willems P. A new needle-crystalline computed radiography detector. J Digit Imaging. 2000;13:117-120.
    • (2000) J Digit Imaging , vol.13 , pp. 117-120
    • Leblans, P.1    Struye, L.2    Willems, P.3
  • 3
    • 3142640846 scopus 로고    scopus 로고
    • A new fast and large area neutron detector using a novel image plate readout technique
    • Schillinger B, Baumann J, Gebele H, et al. A new fast and large area neutron detector using a novel image plate readout technique. Appl Radiat Isot. 2004;61:451-454.
    • (2004) Appl Radiat Isot , vol.61 , pp. 451-454
    • Schillinger, B.1    Baumann, J.2    Gebele, H.3
  • 4
    • 0036033697 scopus 로고    scopus 로고
    • New high-speed scanning technique for computed radiography
    • Schaetzing R, Fasbender R, Kersten P. New high-speed scanning technique for computed radiography. Proc SPIE. 2002;4682:511-520.
    • (2002) Proc SPIE , vol.4682 , pp. 511-520
    • Schaetzing, R.1    Fasbender, R.2    Kersten, P.3
  • 5
    • 0028999842 scopus 로고
    • Comparison of receiver operating characteristic and forced choice observer performance measurement methods
    • Burgess AE. Comparison of receiver operating characteristic and forced choice observer performance measurement methods. Med Phys. 1995;22:643-655.
    • (1995) Med Phys , vol.22 , pp. 643-655
    • Burgess, A.E.1
  • 6
    • 85076214954 scopus 로고
    • Multiscale image contrast amplification (MUSICA)
    • Vuylsteke P, Schoeters E. Multiscale image contrast amplification (MUSICA). Proc SPIE. 1994;2167:551-560.
    • (1994) Proc SPIE , vol.2167 , pp. 551-560
    • Vuylsteke, P.1    Schoeters, E.2
  • 8
    • 3042546856 scopus 로고    scopus 로고
    • Measurement of the detective quantum efficiency (DQE) of digital X-ray imaging devices according to the standard IEC 62220&cjs0025;1
    • Illers H, Buhr E, Bergmann D, et al. Measurement of the detective quantum efficiency (DQE) of digital X-ray imaging devices according to the standard IEC 62220&cjs0025;1. Proc SPIE. 2004;177-187.
    • (2004) Proc SPIE , pp. 177-187
    • Illers, H.1    Buhr, E.2    Bergmann, D.3
  • 9
    • 31444445988 scopus 로고    scopus 로고
    • Contrast-detail evaluation and dose assessment of eight digital chest radiography systems in clinical practice
    • Veldkamp WJ, Kroft LJ, Boot MV, et al. Contrast-detail evaluation and dose assessment of eight digital chest radiography systems in clinical practice. Eur Radiol. 2006;16:333-341.
    • (2006) Eur Radiol , vol.16 , pp. 333-341
    • Veldkamp, W.J.1    Kroft, L.J.2    Boot, M.V.3
  • 10
    • 17644379010 scopus 로고    scopus 로고
    • Computed radiography and direct radiography: Influence of acquisition dose on the detection of simulated lung lesions
    • Uffmann M, Prokop M, Eisenhuber E, et al. Computed radiography and direct radiography: influence of acquisition dose on the detection of simulated lung lesions. Invest Radiol. 2005;40:249-256.
    • (2005) Invest Radiol , vol.40 , pp. 249-256
    • Uffmann, M.1    Prokop, M.2    Eisenhuber, E.3
  • 11
    • 27144484886 scopus 로고    scopus 로고
    • Experimental evaluation of a portable indirect flat-panel detector for the pediatric chest: Comparison with storage phosphor radiography at different exposures by using a chest phantom
    • Rapp-Bernhardt U, Bernhardt TM, Lenzen H, et al. Experimental evaluation of a portable indirect flat-panel detector for the pediatric chest: comparison with storage phosphor radiography at different exposures by using a chest phantom. Radiology. 2005;237:485-491.
    • (2005) Radiology , vol.237 , pp. 485-491
    • Rapp-Bernhardt, U.1    Bernhardt, T.M.2    Lenzen, H.3
  • 12
    • 33644875839 scopus 로고    scopus 로고
    • Computed and conventional chest radiography: A comparison of image quality and radiation dose
    • Ramli K, Abdullah BJ, Ng KH, et al. Computed and conventional chest radiography: a comparison of image quality and radiation dose. Austr Radiol. 2005;49:460-466.
    • (2005) Austr Radiol , vol.49 , pp. 460-466
    • Ramli, K.1    Abdullah, B.J.2    Ng, K.H.3
  • 13
    • 21244469475 scopus 로고    scopus 로고
    • Chest radiography: A comparison of image quality and effective dose using four digital systems
    • Pascoal A, Lawinski CP, Mackenzie A, et al. Chest radiography: a comparison of image quality and effective dose using four digital systems. Radiat Prot Dosimetry. 2005;114:273-277.
    • (2005) Radiat Prot Dosimetry , vol.114 , pp. 273-277
    • Pascoal, A.1    Lawinski, C.P.2    Mackenzie, A.3
  • 14
    • 27744479362 scopus 로고    scopus 로고
    • Comparison of a digital flat-panel versus screen-film, photofluorography and storage-phosphor systems by detection of simulated lung adenocarcinoma lesions using hard copy images
    • Ono K, Yoshitake T, Akahane K, et al. Comparison of a digital flat-panel versus screen-film, photofluorography and storage-phosphor systems by detection of simulated lung adenocarcinoma lesions using hard copy images. Br J Radiol. 2005;78:922-927.
    • (2005) Br J Radiol , vol.78 , pp. 922-927
    • Ono, K.1    Yoshitake, T.2    Akahane, K.3
  • 15
    • 21244454496 scopus 로고    scopus 로고
    • Status and prospects of digital detector technology for CR and DR
    • Neitzel U. Status and prospects of digital detector technology for CR and DR. Radiat Prot Dosimetry. 2005;114:32-38.
    • (2005) Radiat Prot Dosimetry , vol.114 , pp. 32-38
    • Neitzel, U.1
  • 16
    • 25644434974 scopus 로고    scopus 로고
    • Comparison of eight different digital chest radiography systems: Variation in detection of simulated chest disease
    • Kroft LJ, Veldkamp WJ, Mertens BJ, et al. Comparison of eight different digital chest radiography systems: variation in detection of simulated chest disease. AJR Am J Roentgenol. 2005;185:339-346.
    • (2005) AJR Am J Roentgenol , vol.185 , pp. 339-346
    • Kroft, L.J.1    Veldkamp, W.J.2    Mertens, B.J.3
  • 17
    • 2142702254 scopus 로고    scopus 로고
    • Skeletal applications for flat-panel versus storage-phosphor radiography: Effect of exposure on detection of low-contrast details
    • Uffmann M, Schaefer-Prokop C, Neitzel U, et al. Skeletal applications for flat-panel versus storage-phosphor radiography: effect of exposure on detection of low-contrast details. Radiology. 2004;231:506-514.
    • (2004) Radiology , vol.231 , pp. 506-514
    • Uffmann, M.1    Schaefer-Prokop, C.2    Neitzel, U.3
  • 18
    • 0141855190 scopus 로고    scopus 로고
    • Dose reduction in patients undergoing chest imaging: Digital amorphous silicon flat-panel detector radiography versus conventional film-screen radiography and phosphor-based computed radiography
    • Bacher K, Smeets P, Bonnarens K, et al. Dose reduction in patients undergoing chest imaging: digital amorphous silicon flat-panel detector radiography versus conventional film-screen radiography and phosphor-based computed radiography. AJR Am J Roentgenol. 2003;181:923-929.
    • (2003) AJR Am J Roentgenol , vol.181 , pp. 923-929
    • Bacher, K.1    Smeets, P.2    Bonnarens, K.3
  • 19
    • 0036153992 scopus 로고    scopus 로고
    • Performance of a flat-panel detector in detecting artificial bone lesions: Comparison with conventional screen-film and storage-phosphor radiography
    • Ludwig K, Lenzen H, Kamm KF, et al. Performance of a flat-panel detector in detecting artificial bone lesions: comparison with conventional screen-film and storage-phosphor radiography. Radiology. 2002;222:453-459.
    • (2002) Radiology , vol.222 , pp. 453-459
    • Ludwig, K.1    Lenzen, H.2    Kamm, K.F.3
  • 20
    • 0043244882 scopus 로고    scopus 로고
    • Chest imaging with flat-panel detector at low and standard doses: Comparison with storage phosphor technology in normal patients
    • Herrmann A, Bonel H, Stabler A, et al. Chest imaging with flat-panel detector at low and standard doses: comparison with storage phosphor technology in normal patients. Eur Radiol. 2002;12:385-390.
    • (2002) Eur Radiol , vol.12 , pp. 385-390
    • Herrmann, A.1    Bonel, H.2    Stabler, A.3
  • 21
    • 33645233780 scopus 로고    scopus 로고
    • Are new technologies always reducing patient doses in cardiac procedures?
    • Trianni A, Bernardi G, Padovani R. Are new technologies always reducing patient doses in cardiac procedures? Radiat Prot Dosimetry. 2006;117:97-101.
    • (2006) Radiat Prot Dosimetry , vol.117 , pp. 97-101
    • Trianni, A.1    Bernardi, G.2    Padovani, R.3
  • 22
    • 33645222405 scopus 로고    scopus 로고
    • Does digital imaging decrease patient dose? A pilot study and review of the literature
    • Neofotistou V, Tsapaki V, Kottou S, et al. Does digital imaging decrease patient dose? A pilot study and review of the literature. Radiat Prot Dosimetry. 2006;117:204 -210.
    • (2006) Radiat Prot Dosimetry , vol.117 , pp. 204-210
    • Neofotistou, V.1    Tsapaki, V.2    Kottou, S.3
  • 23
    • 2542425641 scopus 로고    scopus 로고
    • Dose reduction in skeletal and chest radiography using a large-area flat-panel detector based on amorphous silicon and thallium-doped cesium iodide: Technical background, basic image quality parameters, and review of the literature
    • Volk M, Hamer OW, Feuerbach S, et al. Dose reduction in skeletal and chest radiography using a large-area flat-panel detector based on amorphous silicon and thallium-doped cesium iodide: technical background, basic image quality parameters, and review of the literature. Eur Radiol. 2004;14:827-834.
    • (2004) Eur Radiol , vol.14 , pp. 827-834
    • Volk, M.1    Hamer, O.W.2    Feuerbach, S.3
  • 24
    • 28044467731 scopus 로고    scopus 로고
    • Initial clinical results with a new needle screen storage phosphor system in chest radiograms
    • Korner M, Wirth S, Treitl M, et al. Initial clinical results with a new needle screen storage phosphor system in chest radiograms. Rofo. 2005;177:1491-1496.
    • (2005) Rofo , vol.177 , pp. 1491-1496
    • Korner, M.1    Wirth, S.2    Treitl, M.3
  • 25
    • 0036122063 scopus 로고    scopus 로고
    • An experimental comparison of detector performance for computed radiography systems
    • Samei E, Flynn MJ. An experimental comparison of detector performance for computed radiography systems. Med Phys. 2002;29:447-459.
    • (2002) Med Phys , vol.29 , pp. 447-459
    • Samei, E.1    Flynn, M.J.2
  • 26
    • 33745108982 scopus 로고    scopus 로고
    • Direct detector radiography versus dual reading computed radiography: Feasibility of dose reduction in chest radiography
    • Gruber M, Uffmann M, Weber M, et al. Direct detector radiography versus dual reading computed radiography: feasibility of dose reduction in chest radiography. Eur Radiol. 2006;1-7.
    • (2006) Eur Radiol , pp. 1-7
    • Gruber, M.1    Uffmann, M.2    Weber, M.3
  • 27
    • 21244460779 scopus 로고    scopus 로고
    • Measurement of the detective quantum efficiency (DQE) of digital X-ray detectors according to the novel standard IEC 62220-1
    • Illers H, Buhr E, Hoeschen C. Measurement of the detective quantum efficiency (DQE) of digital X-ray detectors according to the novel standard IEC 62220-1. Radiat Prot Dosimetry. 2005;114:39-44.
    • (2005) Radiat Prot Dosimetry , vol.114 , pp. 39-44
    • Illers, H.1    Buhr, E.2    Hoeschen, C.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.