메뉴 건너뛰기




Volumn 194, Issue 2, 2010, Pages 398-406

Computer-aided volumetry of pulmonary nodules exhibiting ground-glass opacity at MDCT

Author keywords

Computer aided diagnosis; Ground glass opacity; High resolution CT; Pulmonary nodules; Volumetry

Indexed keywords

ADULT; AGED; ARTICLE; COMPUTER AIDED DESIGN; COMPUTER ASSISTED TOMOGRAPHY; CONTROLLED STUDY; DIAGNOSTIC ACCURACY; FEMALE; GROUND GLASS OPACITY; HUMAN; IMAGE DISPLAY; LUNG NODULE; MAJOR CLINICAL STUDY; MALE; MEASUREMENT; MEASUREMENT ERROR; MULTIDETECTOR COMPUTED TOMOGRAPHY; OBSERVER VARIATION; PHANTOM; PRIORITY JOURNAL; RADIOLOGIST; REPRODUCIBILITY; SIMULATION; VOLUMETRY;

EID: 76149092829     PISSN: 0361803X     EISSN: None     Source Type: Journal    
DOI: 10.2214/AJR.09.2583     Document Type: Article
Times cited : (79)

References (30)
  • 2
    • 0036892529 scopus 로고    scopus 로고
    • Lung cancers missed at low-dose helical CT screening in a general population: Comparison of clinical, histopathologic, and imaging findings
    • Li F, Sone S, Abe H, MacMahon H, Armato SG 3rd, Doi K. Lung cancers missed at low-dose helical CT screening in a general population: comparison of clinical, histopathologic, and imaging findings. Radiology 2002; 225:673-683
    • (2002) Radiology , vol.225 , pp. 673-683
    • Li, F.1    Sone, S.2    Abe, H.3    MacMahon, H.4    Armato 3rd, S.G.5    Doi, K.6
  • 3
    • 34548084613 scopus 로고    scopus 로고
    • Focal interstitial fibrosis manifesting as nodular ground-glass opacity: Thin-section CT findings
    • Park CM, Goo JM, Lee HJ, et al. Focal interstitial fibrosis manifesting as nodular ground-glass opacity: thin-section CT findings. Eur Radiol 2007; 17:2325-2331
    • (2007) Eur Radiol , vol.17 , pp. 2325-2331
    • Park, C.M.1    Goo, J.M.2    Lee, H.J.3
  • 5
    • 0036251768 scopus 로고    scopus 로고
    • Focal groundglass opacity detected by low-dose helical CT
    • Nakata M, Saeki H, Takata I, et al. Focal groundglass opacity detected by low-dose helical CT. Chest 2002; 121:1464-1467
    • (2002) Chest , vol.121 , pp. 1464-1467
    • Nakata, M.1    Saeki, H.2    Takata, I.3
  • 6
    • 0032793947 scopus 로고    scopus 로고
    • Ground-glass opacity on thin-section CT: Value in differentiating subtypes of adenocarcinoma of the lung
    • Kuriyama K, Seto M, Kasugai T, et al. Ground-glass opacity on thin-section CT: value in differentiating subtypes of adenocarcinoma of the lung. AJR 1999; 173:465-469
    • (1999) AJR , vol.173 , pp. 465-469
    • Kuriyama, K.1    Seto, M.2    Kasugai, T.3
  • 7
    • 34548672818 scopus 로고    scopus 로고
    • Persistent pulmonary nodular ground-glass opacity at thin-section CT: Histopathologic comparisons
    • Kim HY, Shim YM, Lee KS, Han J, Yi CA, Kim YK. Persistent pulmonary nodular ground-glass opacity at thin-section CT: histopathologic comparisons. Radiology 2007; 245:267-275
    • (2007) Radiology , vol.245 , pp. 267-275
    • Kim, H.Y.1    Shim, Y.M.2    Lee, K.S.3    Han, J.4    Yi, C.A.5    Kim, Y.K.6
  • 8
    • 0034004916 scopus 로고    scopus 로고
    • Evolution of peripheral lung adenocarcinomas: CT findings correlated with histology and tumor doubling time
    • Aoki T, Nakata H, Watanabe H, et al. Evolution of peripheral lung adenocarcinomas: CT findings correlated with histology and tumor doubling time. AJR 2000; 174:763-768
    • (2000) AJR , vol.174 , pp. 763-768
    • Aoki, T.1    Nakata, H.2    Watanabe, H.3
  • 9
    • 0034867875 scopus 로고    scopus 로고
    • Peripheral lung adenocarcinoma: Correlation of thin-section CT findings with histologic prognostic factors and survival
    • Aoki T, Tomoda Y, Watanabe H, et al. Peripheral lung adenocarcinoma: correlation of thin-section CT findings with histologic prognostic factors and survival. Radiology 2001; 220:803-809
    • (2001) Radiology , vol.220 , pp. 803-809
    • Aoki, T.1    Tomoda, Y.2    Watanabe, H.3
  • 10
    • 9144238705 scopus 로고    scopus 로고
    • Progression of focal pure ground-glass opacity detected by low-dose helical computed tomography screening for lung cancer
    • Kakinuma R, Ohmatsu H, Kaneko M, et al. Progression of focal pure ground-glass opacity detected by low-dose helical computed tomography screening for lung cancer. J Comput Assist Tomogr 2004; 28:17-23
    • (2004) J Comput Assist Tomogr , vol.28 , pp. 17-23
    • Kakinuma, R.1    Ohmatsu, H.2    Kaneko, M.3
  • 11
    • 0034491707 scopus 로고    scopus 로고
    • Growth rate of small lung cancers detected on mass CT screening
    • Hasegawa M, Sone S, Takashima S, et al. Growth rate of small lung cancers detected on mass CT screening. Br J Radiol 2000; 73:1252-1259
    • (2000) Br J Radiol , vol.73 , pp. 1252-1259
    • Hasegawa, M.1    Sone, S.2    Takashima, S.3
  • 12
    • 34248632699 scopus 로고    scopus 로고
    • Accuracy of automated volumetry of pulmonary nodules across different multislice CT scanners
    • Das M, Ley-Zaporozhan J, Gietema HA, et al. Accuracy of automated volumetry of pulmonary nodules across different multislice CT scanners. Eur Radiol 2007; 17:1979-1984
    • (2007) Eur Radiol , vol.17 , pp. 1979-1984
    • Das, M.1    Ley-Zaporozhan, J.2    Gietema, H.A.3
  • 13
    • 0842345498 scopus 로고    scopus 로고
    • Volumetric measurements of pulmonary nodules at multi-row detector CT: In vivo reproducibility
    • Wormanns D, Kohl G, Klotz E, et al. Volumetric measurements of pulmonary nodules at multi-row detector CT: in vivo reproducibility. Eur Radiol 2004; 14:86-92
    • (2004) Eur Radiol , vol.14 , pp. 86-92
    • Wormanns, D.1    Kohl, G.2    Klotz, E.3
  • 14
    • 0141954913 scopus 로고    scopus 로고
    • Three-dimensional segmentation and growth-rate estimation of small pulmonary nodules in helical CT images
    • Kostis WJ, Reeves AP, Yankelevitz DF, Henschke CI. Three-dimensional segmentation and growth-rate estimation of small pulmonary nodules in helical CT images. IEEE Trans Med Imaging 2003; 22:1259-1274
    • (2003) IEEE Trans Med Imaging , vol.22 , pp. 1259-1274
    • Kostis, W.J.1    Reeves, A.P.2    Yankelevitz, D.F.3    Henschke, C.I.4
  • 15
    • 0042931348 scopus 로고    scopus 로고
    • Small pulmonary nodules: Volume measurement at chest CT - phantom study
    • Ko JP, Rusinek H, Jacobs EL, et al. Small pulmonary nodules: volume measurement at chest CT - phantom study. Radiology 2003; 228:864-870
    • (2003) Radiology , vol.228 , pp. 864-870
    • Ko, J.P.1    Rusinek, H.2    Jacobs, E.L.3
  • 16
    • 0034538087 scopus 로고    scopus 로고
    • Small pulmonary nodules: Volumetrically determined growth rates based on CT evaluation
    • Yankelevitz DF, Reeves AP, Kostis WJ, Zhao B, Henschke CI. Small pulmonary nodules: volumetrically determined growth rates based on CT evaluation. Radiology 2000; 217:251-256
    • (2000) Radiology , vol.217 , pp. 251-256
    • Yankelevitz, D.F.1    Reeves, A.P.2    Kostis, W.J.3    Zhao, B.4    Henschke, C.I.5
  • 17
    • 33645120370 scopus 로고    scopus 로고
    • Pulmonary nodules: Estimation of malignancy at thin-section helical CT - effect of computer-aided diagnosis on performance of radiologists
    • Awai K, Murao K, Ozawa A, et al. Pulmonary nodules: estimation of malignancy at thin-section helical CT - effect of computer-aided diagnosis on performance of radiologists. Radiology 2006; 239:276-284
    • (2006) Radiology , vol.239 , pp. 276-284
    • Awai, K.1    Murao, K.2    Ozawa, A.3
  • 19
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986; 1:307-310
    • (1986) Lancet , vol.1 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 20
    • 62649137035 scopus 로고    scopus 로고
    • A comparison of six software packages for evaluation of solid lung nodules using semi-automated volumetry: What is the minimum increase in size to detect growth in repeated CT examinations
    • de Hoop B, Gietema H, van Ginneken B, Zanen P, Groenewegen G, Prokop M. A comparison of six software packages for evaluation of solid lung nodules using semi-automated volumetry: what is the minimum increase in size to detect growth in repeated CT examinations. Eur Radiol 2009; 19:800-808
    • (2009) Eur Radiol , vol.19 , pp. 800-808
    • de Hoop, B.1    Gietema, H.2    van Ginneken, B.3    Zanen, P.4    Groenewegen, G.5    Prokop, M.6
  • 21
    • 33646913058 scopus 로고    scopus 로고
    • Inherent variability of CT lung nodule measurements in vivo using semiautomated volumetric measurements
    • Goodman LR, Gulsun M, Washington L, Nagy PG, Piacsek KL. Inherent variability of CT lung nodule measurements in vivo using semiautomated volumetric measurements. AJR 2006; 186:989-994
    • (2006) AJR , vol.186 , pp. 989-994
    • Goodman, L.R.1    Gulsun, M.2    Washington, L.3    Nagy, P.G.4    Piacsek, K.L.5
  • 22
    • 0141629562 scopus 로고    scopus 로고
    • Effect of varying CT section width on volumetric measurement of lung tumors and application of compensatory equations
    • Winer-Muram HT, Jennings SG, Meyer CA, et al. Effect of varying CT section width on volumetric measurement of lung tumors and application of compensatory equations. Radiology 2003; 229:184-194
    • (2003) Radiology , vol.229 , pp. 184-194
    • Winer-Muram, H.T.1    Jennings, S.G.2    Meyer, C.A.3
  • 23
    • 2142812310 scopus 로고    scopus 로고
    • Small pulmonary nodules: Reproducibility of three-dimensional volumetric measurement and estimation of time to follow-up CT
    • Kostis WJ, Yankelevitz DF, Reeves AP, Fluture SC, Henschke CI. Small pulmonary nodules: reproducibility of three-dimensional volumetric measurement and estimation of time to follow-up CT. Radiology 2004; 231:446-452
    • (2004) Radiology , vol.231 , pp. 446-452
    • Kostis, W.J.1    Yankelevitz, D.F.2    Reeves, A.P.3    Fluture, S.C.4    Henschke, C.I.5
  • 24
    • 33644890197 scopus 로고    scopus 로고
    • Inadequacy of manual measurements compared to automated CT volumetry in assessment of treatment response of pulmonary metastases using RECIST criteria
    • Marten K, Auer F, Schmidt S, Kohl G, Rummeny EJ, Engelke C. Inadequacy of manual measurements compared to automated CT volumetry in assessment of treatment response of pulmonary metastases using RECIST criteria. Eur Radiol 2006; 16:781-790
    • (2006) Eur Radiol , vol.16 , pp. 781-790
    • Marten, K.1    Auer, F.2    Schmidt, S.3    Kohl, G.4    Rummeny, E.J.5    Engelke, C.6
  • 25
    • 67049102265 scopus 로고
    • A biomathematical approach to clinical tumor growth
    • Schwartz M. A biomathematical approach to clinical tumor growth. Cancer 1961; 14:1272-1294
    • (1961) Cancer , vol.14 , pp. 1272-1294
    • Schwartz, M.1
  • 26
    • 0029063625 scopus 로고
    • Small adenocarcinoma of the lung: Histologic characteristics and prognosis
    • Noguchi M, Morikawa A, Kawasaki M, et al. Small adenocarcinoma of the lung: histologic characteristics and prognosis. Cancer 1995; 75:2844-2852
    • (1995) Cancer , vol.75 , pp. 2844-2852
    • Noguchi, M.1    Morikawa, A.2    Kawasaki, M.3
  • 27
    • 35449003214 scopus 로고    scopus 로고
    • Differential diagnosis of ground-glass opacity nodules: CT number analysis by three-dimensional computerized quantification
    • Ikeda K, Awai K, Mori T, Kawanaka K, Yamashita Y, Nomori H. Differential diagnosis of ground-glass opacity nodules: CT number analysis by three-dimensional computerized quantification. Chest 2007; 132:984-990
    • (2007) Chest , vol.132 , pp. 984-990
    • Ikeda, K.1    Awai, K.2    Mori, T.3    Kawanaka, K.4    Yamashita, Y.5    Nomori, H.6
  • 28
    • 34147179045 scopus 로고    scopus 로고
    • Automated volumetry of solid pulmonary nodules in a phantom: Accuracy across different CT scanner technologies
    • Das M, Muhlenbruch G, Katoh M, et al. Automated volumetry of solid pulmonary nodules in a phantom: accuracy across different CT scanner technologies. Invest Radiol 2007; 42:297-302
    • (2007) Invest Radiol , vol.42 , pp. 297-302
    • Das, M.1    Muhlenbruch, G.2    Katoh, M.3
  • 29
    • 18844382442 scopus 로고    scopus 로고
    • Volumetric measurement of synthetic lung nodules with multi-detector row CT: Effect of various image reconstruction parameters and segmentation thresholds on measurement accuracy
    • Goo JM, Tongdee T, Tongdee R, Yeo K, Hildebolt CF, Bae KT. Volumetric measurement of synthetic lung nodules with multi-detector row CT: effect of various image reconstruction parameters and segmentation thresholds on measurement accuracy. Radiology 2005; 235:850-856
    • (2005) Radiology , vol.235 , pp. 850-856
    • Goo, J.M.1    Tongdee, T.2    Tongdee, R.3    Yeo, K.4    Hildebolt, C.F.5    Bae, K.T.6
  • 30
    • 36249024875 scopus 로고    scopus 로고
    • Pulmonary nodules: Interscan variability of semiautomated volume measurements with multisection CT - influence of inspiration level, nodule size, and segmentation performance
    • Gietema HA, Schaefer-Prokop CM, Mali WP, Groenewegen G, Prokop M. Pulmonary nodules: interscan variability of semiautomated volume measurements with multisection CT - influence of inspiration level, nodule size, and segmentation performance. Radiology 2007; 245:888-894
    • (2007) Radiology , vol.245 , pp. 888-894
    • Gietema, H.A.1    Schaefer-Prokop, C.M.2    Mali, W.P.3    Groenewegen, G.4    Prokop, M.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.