메뉴 건너뛰기




Volumn 114, Issue 1-3, 2005, Pages 32-38

Status and prospects of digital detector technology for CR and DR

Author keywords

[No Author keywords available]

Indexed keywords

CESIUM; IODIDE; PHOSPHORUS; SELENIUM; SILICON DIOXIDE;

EID: 21244454496     PISSN: 01448420     EISSN: None     Source Type: Journal    
DOI: 10.1093/rpd/nch532     Document Type: Article
Times cited : (52)

References (22)
  • 1
    • 0031029041 scopus 로고    scopus 로고
    • X-ray detectors for digital radiography
    • Yaffe, M. J. and Rowlands, J. A. X-ray detectors for digital radiography. Phys. Med. Biol. 42, 1-39 (1997).
    • (1997) Phys. Med. Biol. , vol.42 , pp. 1-39
    • Yaffe, M.J.1    Rowlands, J.A.2
  • 2
    • 0033378434 scopus 로고    scopus 로고
    • New detectors for radiology
    • Orava, R. New detectors for radiology. Phys. Med. 15, 295-300 (1999).
    • (1999) Phys. Med. , vol.15 , pp. 295-300
    • Orava, R.1
  • 3
    • 0036797088 scopus 로고    scopus 로고
    • Evaluation of the imaging properties of two generations of a CCD-based system for digital chest radiography
    • Båth, M., Sund, P. and Månsson, L. G. Evaluation of the imaging properties of two generations of a CCD-based system for digital chest radiography. Med. Phys. 29, 2286-2297 (2002).
    • (2002) Med. Phys. , vol.29 , pp. 2286-2297
    • Båth, M.1    Sund, P.2    Månsson, L.G.3
  • 4
    • 0020603401 scopus 로고
    • Computed radiography utilizing scanning laser stimulated luminescence
    • Sonoda, M., Takano, M., Miyahara, J. and Kato, H. Computed radiography utilizing scanning laser stimulated luminescence. Radiology 148, 833-838 (1983).
    • (1983) Radiology , vol.148 , pp. 833-838
    • Sonoda, M.1    Takano, M.2    Miyahara, J.3    Kato, H.4
  • 5
    • 0037038876 scopus 로고    scopus 로고
    • The physics of computed radiography
    • Rowlands, J. A. The physics of computed radiography. Phys. Med. Biol. 47, R123-R166 (2002).
    • (2002) Phys. Med. Biol. , vol.47
    • Rowlands, J.A.1
  • 6
    • 0036122063 scopus 로고    scopus 로고
    • An experimental comparison of detector performance for computed radiography systems
    • Samei, E. and Flynn, M. J. An experimental comparison of detector performance for computed radiography systems. Med. Phys. 29, 447-459 (2002).
    • (2002) Med. Phys. , vol.29 , pp. 447-459
    • Samei, E.1    Flynn, M.J.2
  • 7
    • 0032594583 scopus 로고    scopus 로고
    • Novel computed radiography system with improved image quality by detection of emissions from both sides of an imaging plate
    • Arakawa, S., Ito, W., Kohda, K. and Suzuki, T. Novel computed radiography system with improved image quality by detection of emissions from both sides of an imaging plate. Proc. SPIE 3659, 572-581 (1999).
    • (1999) Proc. SPIE , vol.3659 , pp. 572-581
    • Arakawa, S.1    Ito, W.2    Kohda, K.3    Suzuki, T.4
  • 8
    • 0033731305 scopus 로고    scopus 로고
    • Improvement of image quality in CR mammography by detection of emissions from dual sides of an imaging plate
    • Arakawa, S., Yasuda, H., Kohda, K. and Suzuki, T. Improvement of image quality in CR mammography by detection of emissions from dual sides of an imaging plate. Proc. SPIE 3977, 590-600 (2000).
    • (2000) Proc. SPIE , vol.3977 , pp. 590-600
    • Arakawa, S.1    Yasuda, H.2    Kohda, K.3    Suzuki, T.4
  • 9
    • 0037962482 scopus 로고    scopus 로고
    • Performance evaluation of a "dual-side read" Dedicated mammography computed radiography system
    • Fetterly, K. A. and Schueler, B. A. Performance evaluation of a "dual-side read" dedicated mammography computed radiography system. Med. Phys. 30, 1843-1854 (2003).
    • (2003) Med. Phys. , vol.30 , pp. 1843-1854
    • Fetterly, K.A.1    Schueler, B.A.2
  • 10
    • 0036033697 scopus 로고    scopus 로고
    • New high-speed scanning technique for computed radiography
    • Schaetzing, R., Fasbender, R. and Kersten, P. New high-speed scanning technique for computed radiography. Proc. SPIE 4682, 511-520 (2002).
    • (2002) Proc. SPIE , vol.4682 , pp. 511-520
    • Schaetzing, R.1    Fasbender, R.2    Kersten, P.3
  • 11
    • 0034871385 scopus 로고    scopus 로고
    • New needle-crystalline CR detector
    • Leblans, P. J. R., Struye, L. and Willems, P. New needle-crystalline CR detector. Proc. SPIE 4320, 59-67 (2001).
    • (2001) Proc. SPIE , vol.4320 , pp. 59-67
    • Leblans, P.J.R.1    Struye, L.2    Willems, P.3
  • 12
    • 0036781512 scopus 로고    scopus 로고
    • Digital radiography with large-area flat-panel detectors
    • Kotter, E. and Langer, M. Digital radiography with large-area flat-panel detectors. Eur. Radiol. 12, 2562-2570 (2002).
    • (2002) Eur. Radiol. , vol.12 , pp. 2562-2570
    • Kotter, E.1    Langer, M.2
  • 13
    • 2542425641 scopus 로고    scopus 로고
    • Dose reduction in skeletal and chest radiography using large-area flat-panel detector based on amorphous silicon and thallium-doped cesium iodide: Technical background, basic image quality parameters, and review of the literature
    • Völk, M., Hamer, O. W., Feuerbach, S. and Strotzer, M. Dose reduction in skeletal and chest radiography using large-area flat-panel detector based on amorphous silicon and thallium-doped cesium iodide: technical background, basic image quality parameters, and review of the literature. Eur. Radiol. 14, 827-834 (2004).
    • (2004) Eur. Radiol. , vol.14 , pp. 827-834
    • Völk, M.1    Hamer, O.W.2    Feuerbach, S.3    Strotzer, M.4
  • 14
    • 0000899259 scopus 로고    scopus 로고
    • Flat panel detectors for digital radiography
    • Beutel, J., Kundel, H. L. and Van Metter, R. L., Eds. (Bellingham: SPIE) ISBN 0-8194-3621-6
    • Rowlands, J. A. and Yorkston, J. Flat panel detectors for digital radiography. In: Handbook of Medical Imaging, Vol. 1. Physics and Psychophysics. Beutel, J., Kundel, H. L. and Van Metter, R. L., Eds. (Bellingham: SPIE) pp. 223-328 (2000), ISBN 0-8194-3621-6.
    • (2000) Handbook of Medical Imaging. Physics and Psychophysics , vol.1 , pp. 223-328
    • Rowlands, J.A.1    Yorkston, J.2
  • 15
    • 0037393386 scopus 로고    scopus 로고
    • An experimental comparison of detector performance for direct and indirect radiography systems
    • Samei, E. and Flynn, M. J. An experimental comparison of detector performance for direct and indirect radiography systems. Med. Phys. 30, 608-622 (2003).
    • (2003) Med. Phys. , vol.30 , pp. 608-622
    • Samei, E.1    Flynn, M.J.2
  • 16
    • 3042546856 scopus 로고    scopus 로고
    • Measurement of the detective quantum efficiency (DQE) of digital x-ray imaging devices according to the standard IEC 62220-1
    • Illers, H., Buhr, E., Bergmann, D. and Hoeschen, C. Measurement of the detective quantum efficiency (DQE) of digital x-ray imaging devices according to the standard IEC 62220-1. Proc. SPIE 5368 (2004).
    • (2004) Proc. SPIE , vol.5368
    • Illers, H.1    Buhr, E.2    Bergmann, D.3    Hoeschen, C.4
  • 17
    • 21244460779 scopus 로고    scopus 로고
    • Measurement of the detective quantum efficiency (DQE) of digital X-ray detectors according to the novel standard IEC 62220-1
    • Illers, H., Buhr, E. and Hoeschen, C. Measurement of the detective quantum efficiency (DQE) of digital X-ray detectors according to the novel standard IEC 62220-1. Radiat. Prot. Dosim. 114(1-3), 39-44 (2005).
    • (2005) Radiat. Prot. Dosim. , vol.114 , Issue.1-3 , pp. 39-44
    • Illers, H.1    Buhr, E.2    Hoeschen, C.3
  • 18
    • 0038033786 scopus 로고    scopus 로고
    • Image quality in phosphor-based flat panel digital radiographic detectors
    • Samei, E. Image quality in phosphor-based flat panel digital radiographic detectors. Med. Phys. 30, 1747-1757 (2003).
    • (2003) Med. Phys. , vol.30 , pp. 1747-1757
    • Samei, E.1
  • 19
  • 20
    • 58749103831 scopus 로고    scopus 로고
    • Degradation of the detective quantum efficiency due to a non-unity detector fill factor
    • Cunningham, I. A. Degradation of the detective quantum efficiency due to a non-unity detector fill factor. Proc. SPIE 3032, 22-31 (1997).
    • (1997) Proc. SPIE , vol.3032 , pp. 22-31
    • Cunningham, I.A.1
  • 21
    • 0034873661 scopus 로고    scopus 로고
    • High-resolution CMOS imaging detector
    • Graeve, T. and Weckler, G. P. High-resolution CMOS imaging detector. Proc. SPIE 4320, 68-76 (2001).
    • (2001) Proc. SPIE , vol.4320 , pp. 68-76
    • Graeve, T.1    Weckler, G.P.2
  • 22
    • 0142198857 scopus 로고    scopus 로고
    • New materials and processes for flat-panel X-ray detectors
    • Street, R. A., Lu, J.-P. and Ready, S. R. New materials and processes for flat-panel X-ray detectors. IEE Proc. Circuits Devices Syst. 150, 250-257 (2003).
    • (2003) IEE Proc. Circuits Devices Syst. , vol.150 , pp. 250-257
    • Street, R.A.1    Lu, J.-P.2    Ready, S.R.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.