-
1
-
-
72149091535
-
-
European Commission. Council Directive 97/43/EURATOM of 30 June 1997 on Health Protection of Individuals Against the Dangers of Ionising Radiation in Relation to Medical Exposure, and Repealing Directive 84/466/EURATOM. Official Journal of the European Communities L-180/22 7-9-1997.
-
European Commission. Council Directive 97/43/EURATOM of 30 June 1997 on Health Protection of Individuals Against the Dangers of Ionising Radiation in Relation to Medical Exposure, and Repealing Directive 84/466/EURATOM. Official Journal of the European Communities L-180/22 7-9-1997.
-
-
-
-
2
-
-
34250322597
-
An inter-hospital comparison of patient dose based on clinical indications
-
Teeuwisse W., Geleijns J., and Veldkamp W. An inter-hospital comparison of patient dose based on clinical indications. European Radiology 17 7 (2007) 1795-1805
-
(2007)
European Radiology
, vol.17
, Issue.7
, pp. 1795-1805
-
-
Teeuwisse, W.1
Geleijns, J.2
Veldkamp, W.3
-
3
-
-
33846655389
-
Recent advances in chest radiography
-
McAdams H.P., Samei E., Dobbins III J., Tourassi G.D., and Ravin C.E. Recent advances in chest radiography. Radiology 241 3 (2006) 663-683
-
(2006)
Radiology
, vol.241
, Issue.3
, pp. 663-683
-
-
McAdams, H.P.1
Samei, E.2
Dobbins III, J.3
Tourassi, G.D.4
Ravin, C.E.5
-
5
-
-
0003543948
-
-
Lippincott Williams & Wilkins, Philadelphia pp. 255-91 12-15-2001
-
Bushberg J.T., Seibert J.A., Leidholdt E.M., and Boone J.M. Image quality. The Essential Physics of Medical Imaging. 2nd ed. (2001), Lippincott Williams & Wilkins, Philadelphia pp. 255-91 12-15-2001
-
(2001)
Image quality. The Essential Physics of Medical Imaging. 2nd ed.
-
-
Bushberg, J.T.1
Seibert, J.A.2
Leidholdt, E.M.3
Boone, J.M.4
-
6
-
-
0037700163
-
Subtle lung nodules: influence of local anatomic variations on detection
-
Samei E., Flynn M.J., Peterson E., and Eyler W.R. Subtle lung nodules: influence of local anatomic variations on detection. Radiology 228 1 (2003) 76-84
-
(2003)
Radiology
, vol.228
, Issue.1
, pp. 76-84
-
-
Samei, E.1
Flynn, M.J.2
Peterson, E.3
Eyler, W.R.4
-
7
-
-
21244443851
-
Nodule detection in digital chest radiography: effect of anatomical noise
-
Bath M., Hakansson M., Borjesson S., et al. Nodule detection in digital chest radiography: effect of anatomical noise. Radiation Protection Dosimetry 114 1-3 (2005) 109-113
-
(2005)
Radiation Protection Dosimetry
, vol.114
, Issue.1-3
, pp. 109-113
-
-
Bath, M.1
Hakansson, M.2
Borjesson, S.3
-
8
-
-
21244465968
-
Nodule detection in digital chest radiography: effect of system noise
-
Hakansson M., Bath M., Borjesson S., Kheddache S., Johnsson A.A., and Mansson L.G. Nodule detection in digital chest radiography: effect of system noise. Radiation Protection Dosimetry 114 1-3 (2005) 97-101
-
(2005)
Radiation Protection Dosimetry
, vol.114
, Issue.1-3
, pp. 97-101
-
-
Hakansson, M.1
Bath, M.2
Borjesson, S.3
Kheddache, S.4
Johnsson, A.A.5
Mansson, L.G.6
-
9
-
-
72149127970
-
A technique for simulating the effect of dose reduction on image quality in digital chest radiography
-
2-8-2008
-
Veldkamp W.J., Kroft L.J., van Delft J.P., and Geleijns J. A technique for simulating the effect of dose reduction on image quality in digital chest radiography. Journal of Digital Imaging (2008) 2-8-2008
-
(2008)
Journal of Digital Imaging
-
-
Veldkamp, W.J.1
Kroft, L.J.2
van Delft, J.P.3
Geleijns, J.4
-
10
-
-
35648929997
-
Advances in computed radiography systems and their physical imaging characteristics
-
Cowen A.R., Davies A.G., and Kengyelics S.M. Advances in computed radiography systems and their physical imaging characteristics. Clinical Radiology 62 12 (2007) 1132-1141
-
(2007)
Clinical Radiology
, vol.62
, Issue.12
, pp. 1132-1141
-
-
Cowen, A.R.1
Davies, A.G.2
Kengyelics, S.M.3
-
11
-
-
0032767558
-
Comparison of low contrast detectability between a digital amorphous silicon and a screen-film based imaging system for thoracic radiography
-
Aufrichtig R. Comparison of low contrast detectability between a digital amorphous silicon and a screen-film based imaging system for thoracic radiography. Medical Physics 26 7 (1999) 1349-1358
-
(1999)
Medical Physics
, vol.26
, Issue.7
, pp. 1349-1358
-
-
Aufrichtig, R.1
-
12
-
-
1642304940
-
Digital slot-scan charge-coupled device radiography versus amber and bucky screen-film radiography for detection of simulated nodules and interstitial disease in a chest phantom
-
Kroft L.J.M., Geleijns J., Mertens B.J.A., Veldkamp W.J.H., Zonderland H.M., and de Roos A. Digital slot-scan charge-coupled device radiography versus amber and bucky screen-film radiography for detection of simulated nodules and interstitial disease in a chest phantom. Radiology 231 1 (2004) 156-163
-
(2004)
Radiology
, vol.231
, Issue.1
, pp. 156-163
-
-
Kroft, L.J.M.1
Geleijns, J.2
Mertens, B.J.A.3
Veldkamp, W.J.H.4
Zonderland, H.M.5
de Roos, A.6
-
13
-
-
18844380903
-
Digital slot-scan charge-coupled device radiography versus amber and bucky screen-film radiography: comparison of image quality in a phantom study
-
Veldkamp W.J., Kroft L.J., Mertens B.J., and Geleijns J. Digital slot-scan charge-coupled device radiography versus amber and bucky screen-film radiography: comparison of image quality in a phantom study. Radiology 235 3 (2005) 857-866
-
(2005)
Radiology
, vol.235
, Issue.3
, pp. 857-866
-
-
Veldkamp, W.J.1
Kroft, L.J.2
Mertens, B.J.3
Geleijns, J.4
-
14
-
-
25644434974
-
Comparison of eight different digital chest radiography systems: variation in detection of simulated chest disease
-
Kroft L.J., Veldkamp W.J., Mertens B.J., Boot M.V., and Geleijns J. Comparison of eight different digital chest radiography systems: variation in detection of simulated chest disease. AJR American Journal of Roentgenology 185 2 (2005) 339-346
-
(2005)
AJR American Journal of Roentgenology
, vol.185
, Issue.2
, pp. 339-346
-
-
Kroft, L.J.1
Veldkamp, W.J.2
Mertens, B.J.3
Boot, M.V.4
Geleijns, J.5
-
15
-
-
4644357257
-
Fundamental imaging characteristics of a slot-scan digital chest radiographic system
-
Samei E., Saunders R.S., Lo J.Y., et al. Fundamental imaging characteristics of a slot-scan digital chest radiographic system. Medical Physics 31 9 (2004) 2687-2698
-
(2004)
Medical Physics
, vol.31
, Issue.9
, pp. 2687-2698
-
-
Samei, E.1
Saunders, R.S.2
Lo, J.Y.3
-
16
-
-
0038033836
-
On site evaluation of three flat panel detectors for digital radiography
-
Borasi G., Nitrosi A., Ferrari P., and Tassoni D. On site evaluation of three flat panel detectors for digital radiography. Medical Physics 30 7 (2003) 1719-1731
-
(2003)
Medical Physics
, vol.30
, Issue.7
, pp. 1719-1731
-
-
Borasi, G.1
Nitrosi, A.2
Ferrari, P.3
Tassoni, D.4
-
17
-
-
0037393386
-
An experimental comparison of detector performance for direct and indirect digital radiography systems
-
Samei E., and Flynn M.J. An experimental comparison of detector performance for direct and indirect digital radiography systems. Medical Physics 30 4 (2003) 608-622
-
(2003)
Medical Physics
, vol.30
, Issue.4
, pp. 608-622
-
-
Samei, E.1
Flynn, M.J.2
-
18
-
-
0036781512
-
Digital radiography with large-area flat-panel detectors
-
Kotter E., and Langer M. Digital radiography with large-area flat-panel detectors. European Radiology 12 10 (2002) 2562-2570
-
(2002)
European Radiology
, vol.12
, Issue.10
, pp. 2562-2570
-
-
Kotter, E.1
Langer, M.2
-
19
-
-
49049099386
-
Digital chest radiography: an update on modern technology, dose containment and control of image quality
-
Schaefer-Prokop C., Neitzel U., Venema H.W., Uffmann M., and Prokop M. Digital chest radiography: an update on modern technology, dose containment and control of image quality. European Radiology 18 9 (2008) 1818-1830
-
(2008)
European Radiology
, vol.18
, Issue.9
, pp. 1818-1830
-
-
Schaefer-Prokop, C.1
Neitzel, U.2
Venema, H.W.3
Uffmann, M.4
Prokop, M.5
-
20
-
-
33644623914
-
The clinical effectiveness and cost-effectiveness of computed tomography screening for lung cancer: systematic reviews
-
iii-x, 1
-
Black C., Bagust A., Boland A., et al. The clinical effectiveness and cost-effectiveness of computed tomography screening for lung cancer: systematic reviews. Health Technology Assessment 10 3 (2006) iii-x, 1
-
(2006)
Health Technology Assessment
, vol.10
, Issue.3
-
-
Black, C.1
Bagust, A.2
Boland, A.3
-
21
-
-
0037260023
-
Missed non-small cell lung cancer: radiographic findings of potentially resectable lesions evident only in retrospect
-
Shah P.K., Austin J.H.M., White C.S., et al. Missed non-small cell lung cancer: radiographic findings of potentially resectable lesions evident only in retrospect. Radiology 226 1 (2003) 235-241
-
(2003)
Radiology
, vol.226
, Issue.1
, pp. 235-241
-
-
Shah, P.K.1
Austin, J.H.M.2
White, C.S.3
-
22
-
-
0026513806
-
Missed bronchogenic-carcinoma - radiographic findings in 27 patients with a potentially resectable lesion evident in retrospect
-
Austin J.H.M., Romney B.M., and Goldsmith L.S. Missed bronchogenic-carcinoma - radiographic findings in 27 patients with a potentially resectable lesion evident in retrospect. Radiology 182 1 (1992) 115-122
-
(1992)
Radiology
, vol.182
, Issue.1
, pp. 115-122
-
-
Austin, J.H.M.1
Romney, B.M.2
Goldsmith, L.S.3
-
23
-
-
21244435246
-
Method of simulating dose reduction for digital radiographic systems
-
Bath M., Hakansson M., Tingberg A., and Mansson L.G. Method of simulating dose reduction for digital radiographic systems. Radiation Protection Dosimetry 114 1-3 (2005) 253-259
-
(2005)
Radiation Protection Dosimetry
, vol.114
, Issue.1-3
, pp. 253-259
-
-
Bath, M.1
Hakansson, M.2
Tingberg, A.3
Mansson, L.G.4
-
24
-
-
0037458378
-
An adaptive algorithm for the detection of microcalcifications in simulated low-dose mammography
-
2-21-2003
-
Treiber O., Wanninger F., Fuhr H., Panzer W., Regulla D., and Winkler G. An adaptive algorithm for the detection of microcalcifications in simulated low-dose mammography. Physics in Medicine and Biology 48 4 (2003) 449-466 2-21-2003
-
(2003)
Physics in Medicine and Biology
, vol.48
, Issue.4
, pp. 449-466
-
-
Treiber, O.1
Wanninger, F.2
Fuhr, H.3
Panzer, W.4
Regulla, D.5
Winkler, G.6
-
25
-
-
0036838456
-
Computer-simulated radiation dose reduction for abdominal multidetector CT of pediatric patients
-
Frush D.P., Slack C.C., Hollingsworth C.L., et al. Computer-simulated radiation dose reduction for abdominal multidetector CT of pediatric patients. American Journal of Roentgenology 179 5 (2002) 1107-1113
-
(2002)
American Journal of Roentgenology
, vol.179
, Issue.5
, pp. 1107-1113
-
-
Frush, D.P.1
Slack, C.C.2
Hollingsworth, C.L.3
-
26
-
-
0031023761
-
Simulated dose reduction in conventional chest CT: validation study
-
Mayo J.R., Whittall K.P., Leung A.N., et al. Simulated dose reduction in conventional chest CT: validation study. Radiology 202 2 (1997) 453-457
-
(1997)
Radiology
, vol.202
, Issue.2
, pp. 453-457
-
-
Mayo, J.R.1
Whittall, K.P.2
Leung, A.N.3
-
27
-
-
0036085139
-
CT Colonography at different radiation dose levels: feasibility of dose reduction
-
van Gelder R.E., Venema H.W., Serlie I.W.O., et al. CT Colonography at different radiation dose levels: feasibility of dose reduction. Radiology 224 1 (2002) 25-33
-
(2002)
Radiology
, vol.224
, Issue.1
, pp. 25-33
-
-
van Gelder, R.E.1
Venema, H.W.2
Serlie, I.W.O.3
-
28
-
-
72149127970
-
A Technique for simulating the effect of dose reduction on image quality in digital chest radiography
-
2-8-2008
-
Veldkamp W., Kroft L., van Delft J., and Geleijns J. A Technique for simulating the effect of dose reduction on image quality in digital chest radiography. Jornal of Digital Imaging (2008) 2-8-2008
-
(2008)
Jornal of Digital Imaging
-
-
Veldkamp, W.1
Kroft, L.2
van Delft, J.3
Geleijns, J.4
-
29
-
-
38349043681
-
Dose reduction in digital chest radiography and perceived image quality
-
Kroft L.J.M., Veldkamp W.J.H., Mertens B.J.A., Van Delft J.P.A., and Geleijns J. Dose reduction in digital chest radiography and perceived image quality. British Journal of Radiology 80 960 (2007) 984-988
-
(2007)
British Journal of Radiology
, vol.80
, Issue.960
, pp. 984-988
-
-
Kroft, L.J.M.1
Veldkamp, W.J.H.2
Mertens, B.J.A.3
Van Delft, J.P.A.4
Geleijns, J.5
-
30
-
-
33750337562
-
Detection of simulated nodules on clinical radiographs: dose reduction at digital posteroanterior chest radiography
-
Kroft L.J., Veldkamp W.J., Mertens B.J., van Delft J.P., and Geleijns J. Detection of simulated nodules on clinical radiographs: dose reduction at digital posteroanterior chest radiography. Radiology 241 2 (2006) 392-398
-
(2006)
Radiology
, vol.241
, Issue.2
, pp. 392-398
-
-
Kroft, L.J.1
Veldkamp, W.J.2
Mertens, B.J.3
van Delft, J.P.4
Geleijns, J.5
-
31
-
-
13844256812
-
Chest radiography with a digital flat-panel detector: experimental receiver operating characteristic analysis
-
Metz S., Damoser P., Hollweck R., et al. Chest radiography with a digital flat-panel detector: experimental receiver operating characteristic analysis. Radiology 234 3 (2005) 776-784
-
(2005)
Radiology
, vol.234
, Issue.3
, pp. 776-784
-
-
Metz, S.1
Damoser, P.2
Hollweck, R.3
-
32
-
-
0029071262
-
A comparison of the threshold detail detectability of a screen-film combination and computed radiology under conditions relevant to high-kvp chest radiography
-
Launders J.H., and Cowen A.R. A comparison of the threshold detail detectability of a screen-film combination and computed radiology under conditions relevant to high-kvp chest radiography. Physics in Medicine and Biology 40 8 (1995) 1393-1398
-
(1995)
Physics in Medicine and Biology
, vol.40
, Issue.8
, pp. 1393-1398
-
-
Launders, J.H.1
Cowen, A.R.2
-
33
-
-
0027389777
-
Digital chest radiography with photostimulable storage phosphors - signal-to-noise ratio as a function of kilovoltage with matched exposure risk
-
Chotas H.G., Floyd C.E., Dobbins J.T., and Ravin C.E. Digital chest radiography with photostimulable storage phosphors - signal-to-noise ratio as a function of kilovoltage with matched exposure risk. Radiology 186 2 (1993) 395-398
-
(1993)
Radiology
, vol.186
, Issue.2
, pp. 395-398
-
-
Chotas, H.G.1
Floyd, C.E.2
Dobbins, J.T.3
Ravin, C.E.4
-
34
-
-
17644385206
-
Flat-Panel-Detector chest radiography: effect of tube voltage on image quality
-
Uffmann M., Neitzel U., Prokop M., et al. Flat-Panel-Detector chest radiography: effect of tube voltage on image quality. Radiology 235 2 (2005) 642-650
-
(2005)
Radiology
, vol.235
, Issue.2
, pp. 642-650
-
-
Uffmann, M.1
Neitzel, U.2
Prokop, M.3
-
35
-
-
33744796533
-
Towards optimization in digital chest radiography using monte carlo modelling
-
Ullman G., Sandborg M., Dance D.R., Hunt R.A., and Carlsson G.A. Towards optimization in digital chest radiography using monte carlo modelling. Physics in Medicine and Biology 51 11 (2006) 2729-2743
-
(2006)
Physics in Medicine and Biology
, vol.51
, Issue.11
, pp. 2729-2743
-
-
Ullman, G.1
Sandborg, M.2
Dance, D.R.3
Hunt, R.A.4
Carlsson, G.A.5
-
36
-
-
0037253990
-
Chest radiography: optimization of x-ray spectrum for cesium iodide-amorphous silicon flat-panel detector
-
Dobbins J.T., Samei E., Chotas H.G., et al. Chest radiography: optimization of x-ray spectrum for cesium iodide-amorphous silicon flat-panel detector. Radiology 226 1 (2003) 221-230
-
(2003)
Radiology
, vol.226
, Issue.1
, pp. 221-230
-
-
Dobbins, J.T.1
Samei, E.2
Chotas, H.G.3
-
37
-
-
0344412986
-
Dual-energy chest radiography with a flat-panel digital detector: revealing calcified chest abnormalities
-
Fischbach F., Freund T., Rottgen R., Engert U., Felix R., and Ricke J. Dual-energy chest radiography with a flat-panel digital detector: revealing calcified chest abnormalities. American Journal of Roentgenology 181 6 (2003) 1519-1524
-
(2003)
American Journal of Roentgenology
, vol.181
, Issue.6
, pp. 1519-1524
-
-
Fischbach, F.1
Freund, T.2
Rottgen, R.3
Engert, U.4
Felix, R.5
Ricke, J.6
-
38
-
-
0031024014
-
Digital chest radiography: effect of temporal subtraction images on detection accuracy
-
Difazio M.C., MacMahon H., Xu X.W., et al. Digital chest radiography: effect of temporal subtraction images on detection accuracy. Radiology 202 2 (1997) 447-452
-
(1997)
Radiology
, vol.202
, Issue.2
, pp. 447-452
-
-
Difazio, M.C.1
MacMahon, H.2
Xu, X.W.3
-
39
-
-
0034823999
-
ROC analysis of detection of metastatic pulmonary nodules on digital chest radiographs with temporal subtraction
-
Uozumi T., Nakamura K., Watanabe H., Nakata H., Katsuragawa S., and Doi K. ROC analysis of detection of metastatic pulmonary nodules on digital chest radiographs with temporal subtraction. Academic Radiology 8 9 (2001) 871-878
-
(2001)
Academic Radiology
, vol.8
, Issue.9
, pp. 871-878
-
-
Uozumi, T.1
Nakamura, K.2
Watanabe, H.3
Nakata, H.4
Katsuragawa, S.5
Doi, K.6
-
40
-
-
33751340816
-
Filter Learning: Application to Suppression of Bony Structures From Chest Radiographs
-
To appear in
-
Loog M, van Ginneken B, Schilham AM. Filter Learning: Application to Suppression of Bony Structures From Chest Radiographs. To appear in: Medical Image Analysis 2006.
-
(2006)
Medical Image Analysis
-
-
Loog, M.1
van Ginneken, B.2
Schilham, A.M.3
-
41
-
-
33645673568
-
Image-processing technique for suppressing ribs in chest radiographs by means of massive training artificial neural network (MTANN)
-
Suzuki K., Abe H., MacMahon H., and Doi K. Image-processing technique for suppressing ribs in chest radiographs by means of massive training artificial neural network (MTANN). IEEE Transactions on Medical Imaging 25 4 (2006) 406-416
-
(2006)
IEEE Transactions on Medical Imaging
, vol.25
, Issue.4
, pp. 406-416
-
-
Suzuki, K.1
Abe, H.2
MacMahon, H.3
Doi, K.4
-
43
-
-
54049126162
-
Digital tomosynthesis of the chest
-
Dobbins J.T., McAdams H.P., Godfrey D.J., and Li C.M. Digital tomosynthesis of the chest. Journal of Thoracic Imaging 23 2 (2008) 86-92
-
(2008)
Journal of Thoracic Imaging
, vol.23
, Issue.2
, pp. 86-92
-
-
Dobbins, J.T.1
McAdams, H.P.2
Godfrey, D.J.3
Li, C.M.4
|