Volumn 18, Issue 1, 2014, Pages 301-311

Comparative study of image quality and radiation dose of cone beam and low-dose multislice computed tomography - an in-vitro investigation

Author keywords

Cone beam computed tomography; Image quality; Multislice computed tomography; Radiation dosage

Indexed keywords

ADULT; CADAVER; COMPARATIVE STUDY; CONE BEAM COMPUTED TOMOGRAPHY; FEMALE; HEAD; HUMAN; IMAGE PROCESSING; IN VITRO STUDY; MULTIDETECTOR COMPUTED TOMOGRAPHY; RADIATION DOSE; RADIOGRAPHY; STANDARDS;

EID: 84891557357     PISSN: 14326981     EISSN: 14363771     Source Type: Journal    
DOI: 10.1007/s00784-013-0948-9     Document Type: Article
Times cited : (27)

References (36)
  • 2
    • 14244264415 scopus 로고    scopus 로고
    • Analysis of the accuracy of linear measurements obtained by cone beam computed tomography (CBCT-New Tom)
    • Lascala CA, Panella J, Marques MM (2004) Analysis of the accuracy of linear measurements obtained by cone beam computed tomography (CBCT-New Tom). Dentomaxillofac Radiol 33: 291-294.
    • (2004) Dentomaxillofac Radiol , vol.33 , pp. 291-294
    • Lascala, C.A.1    Panella, J.2    Marques, M.M.3
  • 3
    • 33645731806 scopus 로고    scopus 로고
    • Cone beam computed tomography in orthodontics: benefits and limitations
    • Holberg C, Steinhäuser S, Geis P, Rudzki-Janson I (2005) Cone beam computed tomography in orthodontics: benefits and limitations. J Orofac Orthop 66: 434-444.
    • (2005) J Orofac Orthop , vol.66 , pp. 434-444
    • Holberg, C.1    Steinhäuser, S.2    Geis, P.3    Rudzki-Janson, I.4
  • 4
    • 84880699380 scopus 로고    scopus 로고
    • Quantification of metal artifacts on cone beam computed tomography images
    • doi: 10. 1111/j. 1600-0501. 2011. 02382. x
    • Pauwels R et al (2011) Quantification of metal artifacts on cone beam computed tomography images. Clin Oral Implants Res. doi: 10. 1111/j. 1600-0501. 2011. 02382. x.
    • (2011) Clin Oral Implants Res.
    • Pauwels, R.1
  • 5
    • 47149116057 scopus 로고    scopus 로고
    • Schnittbildverfahren zur dentomaxillofacialen Diagnostik: dosisvergleich von Dental-MSCT und New Tom 9000 DVT
    • Coppenrath E, Draenert F, Lechel U, Veit R, Meindl T, Reiser M et al (2008) Schnittbildverfahren zur dentomaxillofacialen Diagnostik: dosisvergleich von Dental-MSCT und New Tom 9000 DVT. Fortschr Röntgenstr 180: 396-401.
    • (2008) Fortschr Röntgenstr , vol.180 , pp. 396-401
    • Coppenrath, E.1    Draenert, F.2    Lechel, U.3    Veit, R.4    Meindl, T.5    Reiser, M.6
  • 6
    • 43449117523 scopus 로고    scopus 로고
    • Linear accuracy and reliability of cone beam derived 3-dimensional images constructed using an orthodontic volumetric rendering program
    • Periago D, Scarfe W, Moshiri M, Scheetz JP, Silveira AM, Farman AG (2008) Linear accuracy and reliability of cone beam derived 3-dimensional images constructed using an orthodontic volumetric rendering program. Angle Orthod 78: 387-395.
    • (2008) Angle Orthod , vol.78 , pp. 387-395
    • Periago, D.1    Scarfe, W.2    Moshiri, M.3    Scheetz, J.P.4    Silveira, A.M.5    Farman, A.G.6
  • 7
    • 69249102664 scopus 로고    scopus 로고
    • Dosimetry and image quality of four dental cone beam computed tomography scanners compared with multislice computed tomography scanners
    • Suomalainen A, Kiljunen T, Käser Y, Peltola J, Kortesniemi M (2009) Dosimetry and image quality of four dental cone beam computed tomography scanners compared with multislice computed tomography scanners. Dentomaxillofac Radiol 38: 367-378.
    • (2009) Dentomaxillofac Radiol , vol.38 , pp. 367-378
    • Suomalainen, A.1    Kiljunen, T.2    Käser, Y.3    Peltola, J.4    Kortesniemi, M.5
  • 9
    • 33746041477 scopus 로고    scopus 로고
    • Dosimetry of 3 CBCT devices for oral and maxillofacial radiology: CB Mercuray, NewTom 3 G, i-Cat
    • Ludlow JB, Davies-Ludlow LE, Brooks SL, Howerton WB (2006) Dosimetry of 3 CBCT devices for oral and maxillofacial radiology: CB Mercuray, NewTom 3 G, i-Cat. Dentomaxillofac Radiol 35: 219-226.
    • (2006) Dentomaxillofac Radiol , vol.35 , pp. 219-226
    • Ludlow, J.B.1    Davies-Ludlow, L.E.2    Brooks, S.L.3    Howerton, W.B.4
  • 10
    • 52749087498 scopus 로고    scopus 로고
    • Patient risk related to common dental radiographic examination: the impact of 2007 International Commission on Radiological Protection recommendations regarding dose calculations
    • Ludlow JB, Davies-Ludlow LE, White SC (2008) Patient risk related to common dental radiographic examination: the impact of 2007 International Commission on Radiological Protection recommendations regarding dose calculations. J Am Dent Assoc 139(9): 1237-1243.
    • (2008) J Am Dent Assoc , vol.139 , Issue.9 , pp. 1237-1243
    • Ludlow, J.B.1    Davies-Ludlow, L.E.2    White, S.C.3
  • 11
    • 69949169325 scopus 로고    scopus 로고
    • Comparison between effective radiation dose of CBCT and MSCT scanners for dentomaxillofacial applications
    • Loubele M, Bogaerts R, Dijck V, Pauwels R, Vanheusden S, Suetens P et al (2009) Comparison between effective radiation dose of CBCT and MSCT scanners for dentomaxillofacial applications. Eur J Radiol 71: 461-468.
    • (2009) Eur J Radiol , vol.71 , pp. 461-468
    • Loubele, M.1    Bogaerts, R.2    Dijck, V.3    Pauwels, R.4    Vanheusden, S.5    Suetens, P.6
  • 13
    • 5044251144 scopus 로고    scopus 로고
    • Radiation exposure during midfacial imaging using 4- and 16-slice computed tomography, cone beam computed tomography systems and conventional radiography
    • Schulze D, Heiland M, Thurmann H, Adam G (2004) Radiation exposure during midfacial imaging using 4- and 16-slice computed tomography, cone beam computed tomography systems and conventional radiography. Dentomaxillofac Radiol 33: 83-86.
    • (2004) Dentomaxillofac Radiol , vol.33 , pp. 83-86
    • Schulze, D.1    Heiland, M.2    Thurmann, H.3    Adam, G.4
  • 15
    • 77955850723 scopus 로고    scopus 로고
    • A comparative evaluation of cone beam computed tomography (CBCT) and multi-slice CT (MSCT). Part I: on subjective image quality
    • Liang X, Jacobs R, Hassan B, Li L, Pauwels R, Corpas L et al (2010) A comparative evaluation of cone beam computed tomography (CBCT) and multi-slice CT (MSCT). Part I: on subjective image quality. Eur J Radiol 75: 265-269.
    • (2010) Eur J Radiol , vol.75 , pp. 265-269
    • Liang, X.1    Jacobs, R.2    Hassan, B.3    Li, L.4    Pauwels, R.5    Corpas, L.6
  • 16
    • 77955007139 scopus 로고    scopus 로고
    • Comparative study of jaws with multislice computed tomography and cone-beam computed tomography
    • Carrafiello G, Dizonno M, Colli V, Strocchi S, Taubert SP, Leonardi A et al (2010) Comparative study of jaws with multislice computed tomography and cone-beam computed tomography. Radiol med 115: 600-611.
    • (2010) Radiol Med , vol.115 , pp. 600-611
    • Carrafiello, G.1    Dizonno, M.2    Colli, V.3    Strocchi, S.4    Taubert, S.P.5    Leonardi, A.6
  • 17
    • 84866600061 scopus 로고    scopus 로고
    • Dose distribution for dental cone beam CT and its implication for defining a dose index
    • The SEDENTEXCT Project Consortium
    • Pauwels R, Theodorakou C, Walker A, Bosmans H, Jacobs R, Horner K, Bogaerts R, The SEDENTEXCT Project Consortium (2012) Dose distribution for dental cone beam CT and its implication for defining a dose index. Dentomaxillofac Radiol 41(7): 583-593.
    • (2012) Dentomaxillofac Radiol , vol.41 , Issue.7 , pp. 583-593
    • Pauwels, R.1    Theodorakou, C.2    Walker, A.3    Bosmans, H.4    Jacobs, R.5    Horner, K.6    Bogaerts, R.7
  • 18
    • 37349063793 scopus 로고    scopus 로고
    • Comparison of image validity between cone beam computed tomography for dental use and multidetector row helical computed tomography
    • Hashimoto K, Kawashima S, Kameoka S, Akiyama Y, Honjoya T, Ejima K et al (2007) Comparison of image validity between cone beam computed tomography for dental use and multidetector row helical computed tomography. Dentomaxillofac Radiol 36: 465-471.
    • (2007) Dentomaxillofac Radiol , vol.36 , pp. 465-471
    • Hashimoto, K.1    Kawashima, S.2    Kameoka, S.3    Akiyama, Y.4    Honjoya, T.5    Ejima, K.6
  • 19
    • 55249126175 scopus 로고    scopus 로고
    • Comparative study of image quality for MSCT and CBCT scanners for dentomaxillofacial radiology applications
    • Loubele M, Maes F, Jacobs R, van Steenberghe WSC, Suetens P (2008) Comparative study of image quality for MSCT and CBCT scanners for dentomaxillofacial radiology applications. Radiat Prot Dosim 129: 222-226.
    • (2008) Radiat Prot Dosim , vol.129 , pp. 222-226
    • Loubele, M.1    Maes, F.2    Jacobs, R.3    van Steenberghe, W.S.C.4    Suetens, P.5
  • 20
    • 79551537475 scopus 로고    scopus 로고
    • Digital volume tomography (DVT) and multislice spiral CT (MSCT): an objective examination of dose and image quality
    • Kyriakou Y, Kolditz D, Langner O, Krause J, Kalender W (2010) Digital volume tomography (DVT) and multislice spiral CT (MSCT): an objective examination of dose and image quality. Fortschr Röntgenstr 183: 144-153.
    • (2010) Fortschr Röntgenstr , vol.183 , pp. 144-153
    • Kyriakou, Y.1    Kolditz, D.2    Langner, O.3    Krause, J.4    Kalender, W.5
  • 21
    • 84965886444 scopus 로고
    • The equivalence of weighted kappa and the intraclass correlation coefficient as measures of reliability
    • Fleiss JL, Cohen J (1973) The equivalence of weighted kappa and the intraclass correlation coefficient as measures of reliability. EPM 33: 613-619.
    • (1973) Epm , vol.33 , pp. 613-619
    • Fleiss, J.L.1    Cohen, J.2
  • 22
    • 0035531769 scopus 로고    scopus 로고
    • A measure of agreement for interval or nominal multivariate observations
    • Janson H, Olsson U (2001) A measure of agreement for interval or nominal multivariate observations. EPM 61: 277-289.
    • (2001) Epm , vol.61 , pp. 277-289
    • Janson, H.1    Olsson, U.2
  • 24
    • 0017360990 scopus 로고
    • The measurement of observer agreement for categorical data
    • Landis JR, Koch GG (1977) The measurement of observer agreement for categorical data. Biometrics 33: 159-174.
    • (1977) Biometrics , vol.33 , pp. 159-174
    • Landis, J.R.1    Koch, G.G.2
  • 25
    • 45949102819 scopus 로고    scopus 로고
    • Comparative dosimetry of dental CBCT devices and 64-slice CT for oral and maxillofacial radiology
    • Ludlow JB, Ivanovic M (2008) Comparative dosimetry of dental CBCT devices and 64-slice CT for oral and maxillofacial radiology. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 106: 930-938.
    • (2008) Oral Surg Oral Med Oral Pathol Oral Radiol Endod , vol.106 , pp. 930-938
    • Ludlow, J.B.1    Ivanovic, M.2
  • 26
    • 84878597341 scopus 로고    scopus 로고
    • Three-dimensional volume tomographic study of the imaging accuracy of impacted teeth: MSCT and CBCT comparison-an in vitro study
    • doi: 10. 1093/ejo/cjr030
    • Hofmann E, Medelnik J, Fink M, Lell M, Hirschfelder U (2011) Three-dimensional volume tomographic study of the imaging accuracy of impacted teeth: MSCT and CBCT comparison-an in vitro study. Eur J Orthod. doi: 10. 1093/ejo/cjr030.
    • (2011) Eur J Orthod.
    • Hofmann, E.1    Medelnik, J.2    Fink, M.3    Lell, M.4    Hirschfelder, U.5
  • 27
    • 13944281399 scopus 로고    scopus 로고
    • Low-dose dental computed tomography: significant dose reduction without loss of image quality
    • Rustemeyer P, Streubühr U, Suttmoeller J (2004) Low-dose dental computed tomography: significant dose reduction without loss of image quality. Acta Radiol 45: 847-853.
    • (2004) Acta Radiol , vol.45 , pp. 847-853
    • Rustemeyer, P.1    Streubühr, U.2    Suttmoeller, J.3
  • 28
    • 0032240404 scopus 로고    scopus 로고
    • A new volumetric CT machine for dental imaging base on the cone-beam technique: preliminary results
    • Mozzo P, Procacci C, Tacconi A, Martini PT, Andreis IA (1998) A new volumetric CT machine for dental imaging base on the cone-beam technique: preliminary results. Eur Radiol 8: 1558-1564.
    • (1998) Eur Radiol , vol.8 , pp. 1558-1564
    • Mozzo, P.1    Procacci, C.2    Tacconi, A.3    Martini, P.T.4    Andreis, I.A.5
  • 30
  • 31
    • 72649103006 scopus 로고    scopus 로고
    • Accuracy of linear measurements from cone-beam computed tomography-derived surface models of different voxel sizes
    • discussion 16-7
    • Damstra J, Fourie Z, Huddleston Slater JJ, Ren Y (2010) Accuracy of linear measurements from cone-beam computed tomography-derived surface models of different voxel sizes. Am J Orthod Dentofacial Orthop 137: 16. e1-16. e6, discussion 16-7.
    • (2010) Am J Orthod Dentofacial Orthop , vol.137 , pp. 1-6
    • Damstra, J.1    Fourie, Z.2    Huddleston Slater, J.J.3    Ren, Y.4
  • 32
    • 80155176652 scopus 로고    scopus 로고
    • Stellungsnahme: Radiologische 3D-Diagnostik in der Kieferothopädie (CT/DVT)
    • Hirschfelder U (2008) Stellungsnahme: Radiologische 3D-Diagnostik in der Kieferothopädie (CT/DVT). J Orofac Orthoped 69: 484-487.
    • (2008) J Orofac Orthoped , vol.69 , pp. 484-487
    • Hirschfelder, U.1
  • 33
    • 84855604583 scopus 로고    scopus 로고
    • Effective dose range for dental cone beam computed tomography scanners
    • doi:10.1016/j.ejrad.2010.11.028
    • Pauwels R, Beinsberger J, Collaert B, Theodorakou C, Rogers J, Walker A et al (2011) Effective dose range for dental cone beam computed tomography scanners. Eur J Radiol 81(2): 267-271. doi: 10. 1016/j. ejrad. 2010. 11. 028.
    • (2011) Eur J Radiol , vol.81 , Issue.2 , pp. 267-271
    • Pauwels, R.1    Beinsberger, J.2    Collaert, B.3    Theodorakou, C.4    Rogers, J.5    Walker, A.6
  • 34
    • 33748632657 scopus 로고    scopus 로고
    • Three-dimensional cephalometry: spiral multi-slice vs. cone-beam computed tomography
    • Swennen G, Schutyser F (2006) Three-dimensional cephalometry: spiral multi-slice vs. cone-beam computed tomography. Am J Orthod Dentofac Orthop 130: 410-416.
    • (2006) Am J Orthod Dentofac Orthop , vol.130 , pp. 410-416
    • Swennen, G.1    Schutyser, F.2
  • 35
    • 84891557055 scopus 로고    scopus 로고
    • Bundesamt für Strahlenschutz
    • Bundesamt für Strahlenschutz (2010) http://www. bfs. de/de/ion/wirkungen/grenzwerte. html.
    • (2010)


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.