메뉴 건너뛰기




Volumn 8, Issue 9, 1998, Pages 1558-1564

A new volumetric CT machine for dental imaging based on the cone-beam technique: Preliminary results

Author keywords

Computed tomography; Cone beam; Dental imaging

Indexed keywords

ABSORPTION; ARTICLE; COMPARATIVE STUDY; COMPUTER ASSISTED TOMOGRAPHY; COMPUTER PROGRAM; COST CONTROL; ECONOMICS; FACIAL BONE; HUMAN; IMAGE PROCESSING; IMAGE QUALITY; INSTRUMENTATION; JAW; METHODOLOGY; RADIATION DOSE; RADIOGRAPHY; TOOTH; TOOTH IMPLANTATION; TOOTH RADIOGRAPHY;

EID: 0032240404     PISSN: 09387994     EISSN: None     Source Type: Journal    
DOI: 10.1007/s003300050586     Document Type: Article
Times cited : (940)

References (15)
  • 1
    • 0019206789 scopus 로고
    • Computerized tomography in oral and maxillofacial surgery
    • Ames JR, Johnson RP, Stevens EA (1980) Computerized tomography in oral and maxillofacial surgery. J Oral Surg 38: 145
    • (1980) J Oral Surg , vol.38 , pp. 145
    • Ames, J.R.1    Johnson, R.P.2    Stevens, E.A.3
  • 2
    • 0023916309 scopus 로고
    • CT in the preoperative assessment of the mandible and maxilla for endosseous implant surgery
    • Rothman SLG, Chaftez N, Rhodes ML, Schwartz MS (1988) CT in the preoperative assessment of the mandible and maxilla for endosseous implant surgery. Radiology 168: 171
    • (1988) Radiology , vol.168 , pp. 171
    • Rothman, S.L.G.1    Chaftez, N.2    Rhodes, M.L.3    Schwartz, M.S.4
  • 3
    • 0027584215 scopus 로고
    • CT scan as radiologic database for optimum implant orientation
    • Weinberg LA (1993) CT scan as radiologic database for optimum implant orientation. J Prosthet Dent 69: 381
    • (1993) J Prosthet Dent , vol.69 , pp. 381
    • Weinberg, L.A.1
  • 4
    • 0027728555 scopus 로고
    • Precise site location for implants using CT scans: A technical note
    • Sethi A (1993) Precise site location for implants using CT scans: a technical note. Int J Oral Maxillofac Implants 8: 433
    • (1993) Int J Oral Maxillofac Implants , vol.8 , pp. 433
    • Sethi, A.1
  • 5
    • 0029247618 scopus 로고
    • CT data acquisition as a basis for modern diagnosis and therapy in maxillofacial surgery
    • Falk A, Gielen S, Heuser L (1995) CT data acquisition as a basis for modern diagnosis and therapy in maxillofacial surgery. Int J Oral Maxillofac Surg 24: 69
    • (1995) Int J Oral Maxillofac Surg , vol.24 , pp. 69
    • Falk, A.1    Gielen, S.2    Heuser, L.3
  • 6
    • 0017150067 scopus 로고
    • The capability of fluoroscopic systems for the production of computerized axial tomograms
    • Baily NA, Keller RA, Jacowatz CW, Kak AC (1976) The capability of fluoroscopic systems for the production of computerized axial tomograms. Invest Radiol 11: 434
    • (1976) Invest Radiol , vol.11 , pp. 434
    • Baily, N.A.1    Keller, R.A.2    Jacowatz, C.W.3    Kak, A.C.4
  • 7
    • 0017899102 scopus 로고
    • The determination of anatomical cross sections using a radiotherapy simulator
    • Harrison RM, Farmer FT (1978) The determination of anatomical cross sections using a radiotherapy simulator. Br J Radiol 59: 448
    • (1978) Br J Radiol , vol.59 , pp. 448
    • Harrison, R.M.1    Farmer, F.T.2
  • 8
    • 0021264428 scopus 로고
    • Investigations using an X-ray image intensifier and a TV camera for imaging transverse sections in humans
    • Arnot RN, Willetts RJ, Batten JR, Orr JS (1984) Investigations using an X-ray image intensifier and a TV camera for imaging transverse sections in humans. Br J Radiol 57: 47
    • (1984) Br J Radiol , vol.57 , pp. 47
    • Arnot, R.N.1    Willetts, R.J.2    Batten, J.R.3    Orr, J.S.4
  • 11
    • 0027968590 scopus 로고
    • Cone-beam X-ray microtomography of small specimens
    • Machin K, Webb S (1994) Cone-beam X-ray microtomography of small specimens. Phys Med Biol 39: 1639
    • (1994) Phys Med Biol , vol.39 , pp. 1639
    • Machin, K.1    Webb, S.2
  • 12
    • 0016776698 scopus 로고
    • X-ray scatter background signals in transmission radiography
    • Motz JW, Dick CE (1975) X-ray scatter background signals in transmission radiography. Med Phys 2: 259
    • (1975) Med Phys , vol.2 , pp. 259
    • Motz, J.W.1    Dick, C.E.2
  • 13
    • 0020631503 scopus 로고
    • Truncated-view artifacts: Clinical importance on CT
    • Lehr JL (1983) Truncated-view artifacts: clinical importance on CT. AJR 141: 183
    • (1983) AJR , vol.141 , pp. 183
    • Lehr, J.L.1
  • 14
    • 0026689155 scopus 로고
    • Grids or air gaps for scatter reduction in digital radiography: A model calculation
    • Neitzel U (1992) Grids or air gaps for scatter reduction in digital radiography: a model calculation. Med Phys 19: 475
    • (1992) Med Phys , vol.19 , pp. 475
    • Neitzel, U.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.