메뉴 건너뛰기




Volumn 48, Issue 11, 2013, Pages 2734-2745

Ultrasonic imaging transceiver design for cmut: A three-level 30-vpp pulse-shaping pulser with improved efficiency and a noise-optimized receiver

Author keywords

Capacitive micromachined ultrasonic transducer (CMUT); Charge recycling; Multilevel pulse shaping; Noise efficiency factor (NEF); Pulse echo response; Transimpedance amplifier (TIA); Transmitter (Tx) efficiency; Tx beamformation; Ultrasonic Doppler flow rate detection; Ultrasonic transceiver

Indexed keywords

BEAMFORMATION; CAPACITIVE MICROMACHINED ULTRASONIC TRANSDUCER; CHARGE RECYCLING; NOISE EFFICIENCY FACTORS; PULSE ECHOES; RATE DETECTION; TRANSIMPEDANCE AMPLIFIERS; TRANSMITTERS (TX);

EID: 84887322148     PISSN: 00189200     EISSN: None     Source Type: Journal    
DOI: 10.1109/JSSC.2013.2274895     Document Type: Article
Times cited : (118)

References (36)
  • 1
    • 0031696792 scopus 로고    scopus 로고
    • Cramming more components onto integrated circuits
    • Jan.
    • G. E. Moore, "Cramming more components onto integrated circuits," Proc. IEEE, vol. 86, no. 1, pp. 82-85, Jan. 1998.
    • (1998) Proc. IEEE , vol.86 , Issue.1 , pp. 82-85
    • Moore, G.E.1
  • 2
    • 79551506547 scopus 로고    scopus 로고
    • Diagnostic accuracy of a hand-held ultrasound scanner in routine patients referred for echocardiography
    • C. Prinz and J. Voigt, "Diagnostic accuracy of a hand-held ultrasound scanner in routine patients referred for echocardiography," J. Amer. Soc. Echocardiography, vol. 24, no. 2, pp. 111-116, 2010.
    • (2010) J. Amer. Soc. Echocardiography , vol.24 , Issue.2 , pp. 111-116
    • Prinz, C.1    Voigt, J.2
  • 8
    • 80052043902 scopus 로고    scopus 로고
    • Front-end receiver electronics for high-frequency monolithic CMUT-on-CMOS imaging arrays
    • Aug.
    • G. Gurun, P. Hasler, and F. L. Degertekin, "Front-end receiver electronics for high-frequency monolithic CMUT-on-CMOS imaging arrays," IEEE Trans. Ultrason., Ferroelectr., Freq. Control, vol. 58, no. 8, pp. 1658-1668, Aug. 2011.
    • (2011) IEEE Trans. Ultrason., Ferroelectr., Freq. Control , vol.58 , Issue.8 , pp. 1658-1668
    • Gurun, G.1    Hasler, P.2    Degertekin, F.L.3
  • 13
    • 84856643529 scopus 로고    scopus 로고
    • Harmonic reduction in capacitive micromachined ultrasonic transducers by gap feedback linearization
    • Jan.
    • S. Satir and F. L. Degertekin, "Harmonic reduction in capacitive micromachined ultrasonic transducers by gap feedback linearization," IEEE Trans. Ultrason., Ferroelectr., Freq. Control, vol. 59, no. 1, pp. 50-59, Jan. 2012.
    • (2012) IEEE Trans. Ultrason., Ferroelectr., Freq. Control , vol.59 , Issue.1 , pp. 50-59
    • Satir, S.1    Degertekin, F.L.2
  • 14
    • 84855471609 scopus 로고    scopus 로고
    • Ultrasound system considerations and their impact on front-end components
    • E. Brunner, "Ultrasound system considerations and their impact on front-end components," Analog Dialogue, Analog Devices Inc., vol. 36, no. 3, 2002.
    • (2002) Analog Dialogue, Analog Devices Inc. , vol.36 , Issue.3
    • Brunner, E.1
  • 20
    • 84881082341 scopus 로고    scopus 로고
    • Ultrasonic imaging front-end design for CMUT: A 3-level 30 vpp pulse-shaping pulser with improved efficiency and a noise-optimized receiver
    • K. Chen, A. P. Chandrakasan, and C. G. Sodini, "Ultrasonic imaging front-end design for CMUT: A 3-level 30 vpp pulse-shaping pulser with improved efficiency and a noise-optimized receiver," in Proc. IEEE Asian Solid State Circuits Conf., 2012, pp. 173-176.
    • (2012) Proc. IEEE Asian Solid State Circuits Conf. , pp. 173-176
    • Chen, K.1    Chandrakasan, A.P.2    Sodini, C.G.3
  • 22
    • 67649307355 scopus 로고    scopus 로고
    • Co-optimization of CMUT and receive amplifiers to suppress effects of neighbor coupling between CMUT elements
    • Nov.
    • S. Berg, T. Ytterdal, and A. Ronnekleiv, "Co-optimization of CMUT and receive amplifiers to suppress effects of neighbor coupling between CMUT elements," in Proc. IEEE Ultrason. Symp., Nov. 2008, pp. 2103-2106.
    • (2008) Proc. IEEE Ultrason. Symp. , pp. 2103-2106
    • Berg, S.1    Ytterdal, T.2    Ronnekleiv, A.3
  • 26
    • 37849004333 scopus 로고    scopus 로고
    • Evaluation of the angular spectrum approach for simulations of near-field pressures
    • X. Zeng and R. J. McGough, "Evaluation of the angular spectrum approach for simulations of near-field pressures," J. Acoust. Soc. Amer., vol. 123, no. 1, p. 68, 2008.
    • (2008) J. Acoust. Soc. Amer. , vol.123 , Issue.1 , pp. 68
    • Zeng, X.1    McGough, R.J.2
  • 27
    • 24044478820 scopus 로고    scopus 로고
    • Field: A program for simulating ultrasound systems
    • J. Jensen, "Field: A program for simulating ultrasound systems," in Proc. NordicBaltic Conf. Biomed. Imaging, 1996, vol. 4, pp. 351-353, suppl. 1, pt. 1.
    • Proc. NordicBaltic Conf. Biomed. Imaging, 1996 , vol.4 , Issue.SUPPL. 1 , pp. 351-353
    • Jensen, J.1
  • 28
    • 0026838720 scopus 로고
    • Calculation of pressure fields from arbitrarily shaped, apodized, and excited ultrasound transducers
    • Mar.
    • J. A. Jensen and N. B. Svendsen, "Calculation of pressure fields from arbitrarily shaped, apodized, and excited ultrasound transducers," IEEE Trans. Ultrason., Ferroelectr., Freq. Control, vol. 39, no. 2, pp. 262-267, Mar. 1992.
    • (1992) IEEE Trans. Ultrason., Ferroelectr., Freq. Control , vol.39 , Issue.2 , pp. 262-267
    • Jensen, J.A.1    Svendsen, N.B.2
  • 29
    • 33644859258 scopus 로고    scopus 로고
    • Design of a front-end integrated circuit for 3D acoustic imaging using 2D CMUT arrays
    • Dec.
    • I. Cicek, A. Bozkurt, and M. Karaman, "Design of a front-end integrated circuit for 3D acoustic imaging using 2D CMUT arrays," IEEE Trans. Ultrason., Ferroelectr., Freq. Control, vol. 52, no. 12, pp. 2235-2241, Dec. 2005.
    • (2005) IEEE Trans. Ultrason., Ferroelectr., Freq. Control , vol.52 , Issue.12 , pp. 2235-2241
    • Cicek, I.1    Bozkurt, A.2    Karaman, M.3
  • 30
    • 0023561471 scopus 로고
    • A micropower low-noise monolithic instrumentation amplifier for medical purposes
    • Dec.
    • M. S. J. Steyaert,W.M. C. Sansen, and C. Zhongyuan, "A micropower low-noise monolithic instrumentation amplifier for medical purposes," IEEE J. Solid-State Circuits, vol. SSC-22, pp. 1163-1168, Dec. 1987.
    • (1987) IEEE J. Solid-State Circuits , vol.SSC-22 , pp. 1163-1168
    • Steyaert, M.S.J.1    Sansen, W.M.C.2    Zhongyuan, C.3
  • 35
    • 84939739865 scopus 로고
    • Real-time twodimensional blood flow imaging using an autocorrelation technique
    • May
    • C. Kasai, K. Namekawa, A. Koyano, and R. Omoto, "Real-time twodimensional blood flow imaging using an autocorrelation technique," IEEE Trans. Sonics Ultrason., vol. SU-32, no. 3, pp. 458-463, May 1985.
    • (1985) IEEE Trans. Sonics Ultrason. , vol.SU-32 , Issue.3 , pp. 458-463
    • Kasai, C.1    Namekawa, K.2    Koyano, A.3    Omoto, R.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.