메뉴 건너뛰기




Volumn 56, Issue , 2013, Pages 396-397

3D volumetric ultrasound imaging with a 32×32 CMUT array integrated with front-end ICs using flip-chip bonding technology

Author keywords

[No Author keywords available]

Indexed keywords

3D IMAGING SYSTEM; 3D ULTRASOUND IMAGES; 3D ULTRASOUND IMAGING; CAPACITIVE MICROMACHINED ULTRASONIC TRANSDUCER; FLIP-CHIP BONDING; MECHANICAL DEMONSTRATIONS; TRANSDUCER ARRAY; ULTRASOUND IMAGING;

EID: 84876523487     PISSN: 01936530     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/ISSCC.2013.6487786     Document Type: Conference Paper
Times cited : (37)

References (5)
  • 1
    • 77952817084 scopus 로고    scopus 로고
    • Multi-row linear cmut array using cmuts and multiplexing electronics
    • Sept
    • R. Wodnicki, C.G. Woychik, A.T. Byun, et al., "Multi-Row Linear CMUT Array using CMUTs and Multiplexing Electronics," IEEE Ultrason. Symp., pp. 2696-2699, Sept. 2009
    • (2009) IEEE Ultrason. Symp , pp. 2696-2699
    • Wodnicki, R.1    Woychik, C.G.2    Byun, A.T.3
  • 3
    • 72749107528 scopus 로고    scopus 로고
    • An integrated circuit with transmit beamforming flip-chip bonded to a 2-d cmut array for 3-d ultrasound imaging
    • Oct
    • I.O. Wygant, N.S. Jamal, H.J. Lee, et al., "An Integrated Circuit with Transmit Beamforming Flip-Chip Bonded to a 2-D CMUT Array for 3-D Ultrasound Imaging," IEEE Trans. Ultrason., Ferroelect., Freq. Contr., vol. 56, no. 10, pp. 2145-56, Oct. 2009
    • (2009) IEEE Trans. Ultrason., Ferroelect., Freq. Contr , vol.56 , Issue.10 , pp. 2145-2156
    • Wygant, I.O.1    Jamal, N.S.2    Lee, H.J.3
  • 4
    • 85057115507 scopus 로고
    • 5 V-To-75 v cmos output interface circuits
    • Feb
    • M. Declerq, M. Schubert, and F. Clement, "5 V-To-75 V CMOS Output Interface Circuits," ISSCC Dig. Tech. Papers, pp. 162-163, 283, Feb. 1993
    • (1993) ISSCC Dig. Tech. Papers , vol.283 , pp. 162-163
    • Declerq, M.1    Schubert, M.2    Clement, F.3
  • 5
    • 67649537421 scopus 로고    scopus 로고
    • Minimally redundant 2-d array designs for 3-d medical ultrasound imaging
    • July
    • M. Karaman, I.O. Wygant Oralkan, and B.T. Khuri-Yakub, "Minimally Redundant 2-D Array Designs for 3-D Medical Ultrasound Imaging," IEEE Trans. Med. Imag., vol. 28, no. 7, pp. 1051-1061, July 2009
    • (2009) IEEE Trans. Med. Imag , vol.28 , Issue.7 , pp. 1051-1061
    • Karaman, M.1    Wygant Oralkan, I.O.2    Khuri-Yakub, B.T.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.