-
2
-
-
83155168249
-
Background levels and diurnal variations of hydrogen cyanide in breath and emitted from skin
-
F. M. Schmidt et al., "Background levels and diurnal variations of hydrogen cyanide in breath and emitted from skin, " J. Breath Res. 5(4), 1-10 (2011).
-
(2011)
J. Breath Res.
, vol.5
, Issue.4
, pp. 1-10
-
-
Schmidt, F.M.1
-
3
-
-
0031985773
-
Why are so many food plants cyanogenic?
-
DOI 10.1016/S0031-9422(97)00425-1, PII S0031942297004251
-
D. A. Jones, "Why are so many food plants cyanogenic?" Phytochemistry 47(2), 155-162 (1998). (Pubitemid 28029036)
-
(1998)
Phytochemistry
, vol.47
, Issue.2
, pp. 155-162
-
-
Jones, D.A.1
-
4
-
-
0003884930
-
-
McGraw-Hill Professional, Blacklick, OH
-
J. E. Tintinalli, G. D. Kelen, and J. S. Stapczynski, Emergency Medicine: A Comprehensive Study Guide, McGraw-Hill Professional, Blacklick, OH (2004).
-
(2004)
Emergency Medicine: A Comprehensive Study Guide
-
-
Tintinalli, J.E.1
Kelen, G.D.2
Stapczynski, J.S.3
-
5
-
-
33751282207
-
Cyanide action in plants - From toxic to regulatory
-
I. Siegien and R. Bogatek, "Cyanide action in plants-from toxic to regulatory, " Acta Physiol. 28(5), 483-497 (2006). (Pubitemid 44800045)
-
(2006)
Acta Physiologiae Plantarum
, vol.28
, Issue.5
, pp. 483-497
-
-
Siegien, I.1
Bogatek, R.2
-
6
-
-
0001213003
-
Formation of cyanide from carbon-1 of 1-amino-cyclopropane-1-carboxylic acid during its conversion to ethylene
-
G. D. Peiser et al., "Formation of cyanide from carbon-1 of 1-amino-cyclopropane-1-carboxylic acid during its conversion to ethylene, " Proc. Natl. Acad. Sci. U. S. A. 81(10), 3059-3063 (1984).
-
(1984)
Proc. Natl. Acad. Sci. U. S. A.
, vol.81
, Issue.10
, pp. 3059-3063
-
-
Peiser, G.D.1
-
7
-
-
0001626381
-
Metabolism of hydrogen-cyanide by higher-plants
-
J. M. Miller and E. E. Conn, "Metabolism of hydrogen-cyanide by higher-plants, " Plant Physiol. 65(6), 1199-1202 (1980).
-
(1980)
Plant Physiol.
, vol.65
, Issue.6
, pp. 1199-1202
-
-
Miller, J.M.1
Conn, E.E.2
-
8
-
-
77954860450
-
Dissipation of cyanogenic glucosides and cyanide in soil amended with white clover (Trifolium repens L.)
-
K. Refsgaard et al., "Dissipation of cyanogenic glucosides and cyanide in soil amended with white clover (Trifolium repens L.), " Soil Biol. Biochem. 42(7), 1108-1113 (2010).
-
(2010)
Soil Biol. Biochem.
, vol.42
, Issue.7
, pp. 1108-1113
-
-
Refsgaard, K.1
-
9
-
-
1642593932
-
Cyanoglucoside biosynthesis in white clover (Trifolium repens)
-
M. A. Hughes and E. E. Conn, "Cyanoglucoside biosynthesis in white clover (Trifolium repens), " Phytochemistry 15(5), 697-701 (1976).
-
(1976)
Phytochemistry
, vol.15
, Issue.5
, pp. 697-701
-
-
Hughes, M.A.1
Conn, E.E.2
-
10
-
-
84861194931
-
Quantification of Pseudomonas aeruginosa hydrogen cyanide production by a polarographic approach
-
A.-S. Blieret al., "Quantification of Pseudomonas aeruginosa hydrogen cyanide production by a polarographic approach, " J. Microbiol. Methods 90(1), 20-24 (2012).
-
(2012)
J. Microbiol. Methods
, vol.90
, Issue.1
, pp. 20-24
-
-
-
11
-
-
79953715144
-
Pseudomonas aeruginosa and cyanide production
-
W. Lenney and F Gilchrist, "Pseudomonas aeruginosa and cyanide production, " Eur. Respir. J. 37(3), 482-483 (2011).
-
(2011)
Eur. Respir. J.
, vol.37
, Issue.3
, pp. 482-483
-
-
Lenney, W.1
Gilchrist, F.2
-
12
-
-
0034764166
-
Early pulmonary infection, inflammation, and clinical outcomes in infants with cystic fibrosis
-
DOI 10.1002/ppul.1144
-
M. Rosenfeld et al., "Early pulmonary infection, inflammation, and clinical outcomes in infants with cystic fibrosis, " Pediatr. Pulmonol. 32(5), 356-366 (2001). (Pubitemid 33015652)
-
(2001)
Pediatric Pulmonology
, vol.32
, Issue.5
, pp. 356-366
-
-
Rosenfeld, M.1
Gibson, R.L.2
McNamara, S.3
Emerson, J.4
Burns, J.L.5
Castile, R.6
Hiatt, P.7
McCoy, K.8
Wilson, C.B.9
Inglis, A.10
Smith, A.11
Martin, T.R.12
Ramsey, B.W.13
-
13
-
-
0036320272
-
Pseudomonas aeruginosa and other predictors of mortality and morbidity in young children with cystic fibrosis
-
DOI 10.1002/ppul.10127
-
J. Emerson et al., "Pseudomonas aeruginosa and other predictors of mortality and morbidity in young children with cystic fibrosis, " Pediatr. Pulmonol. 34(2), 91-100 (2002). (Pubitemid 34809519)
-
(2002)
Pediatric Pulmonology
, vol.34
, Issue.2
, pp. 91-100
-
-
Emerson, J.1
Rosenfeld, M.2
McNamara, S.3
Ramsey, B.4
Gibson, R.L.5
-
14
-
-
0025349031
-
Cystic fibrosis: A disease in electrolyte transport
-
P. M. Quinton, "Cystic fibrosis: a disease in electrolyte transport, " FASEB J. 4(10), 2709-2717 (1990).
-
(1990)
FASEB J.
, vol.4
, Issue.10
, pp. 2709-2717
-
-
Quinton, P.M.1
-
15
-
-
0025242929
-
Defective intracellular transport and processing of CFTR is the molecular basis of most cystic fibrosis
-
S. H. Cheng et al., "Defective intracellular transport and processing of CFTR is the molecular basis of most cystic fibrosis, " Cell 63(4), 827-834 (1990). (Pubitemid 120035055)
-
(1990)
Cell
, vol.63
, Issue.4
, pp. 827-834
-
-
Cheng, S.H.1
Gregory, R.J.2
Marshall, J.3
Paul, S.4
Souza, D.W.5
White, G.A.6
O'Riordan, C.R.7
Smith, A.E.8
-
16
-
-
0035191641
-
Pharmacological treatment of the ion transport defect in cystic fibrosis
-
DOI 10.1517/13543784.10.1.1
-
G. M. Roomans, "Pharmacological treatment of the ion transport defect in cystic fibrosis, " Expert Opin. Invest. Drugs 10(1), 1-19 (2001). (Pubitemid 32014151)
-
(2001)
Expert Opinion on Investigational Drugs
, vol.10
, Issue.1
, pp. 1-19
-
-
Roomans, G.M.1
-
17
-
-
34047166052
-
Airway surface dehydration in cystic fibrosis: Pathogenesis and therapy
-
DOI 10.1146/annurev.med.58.071905.105316
-
R. C. Boucher, "Airway surface dehydration in cystic fibrosis: pathogenesis and therapy, " Annu. Rev. Med. 58, 157-170 (2007). (Pubitemid 46706507)
-
(2007)
Annual Review of Medicine
, vol.58
, pp. 157-170
-
-
Boucher, R.C.1
-
18
-
-
0029870085
-
Cystic fibrosis airway epithelia fail to kill bacteria because of abnormal airway surface fluid
-
DOI 10.1016/S0092-8674(00)81099-5
-
J. J. Smith et al., "Cystic fibrosis airway epithelia fail to kill bacteria because of abnormal airway surface fluid, " Cell 85(2), 229-236 (1996). (Pubitemid 26118164)
-
(1996)
Cell
, vol.85
, Issue.2
, pp. 229-236
-
-
Smith, J.J.1
Travis, S.M.2
Greenberg, E.P.3
Welsh, M.J.4
-
19
-
-
0030995361
-
Antibiotic treatment of initial colonization with Pseudomonas aeruginosa postpones chronic infection and prevents deterioration of pulmonary function in cystic fibrosis
-
DOI 10.1002/(SICI)1099-0496(199705)23:5<330::AID-PPUL4>3.0.CO;2-O
-
B. Frederiksen, C. Koch, and N. Hoiby, "Antibiotic treatment of initial colonization with Pseudomonas aeruginosa postpones chronic infection and prevents deterioration of pulmonary function in cystic fibrosis, " Pediatr. Pulmonol. 23(5), 330-335 (1997). (Pubitemid 27225208)
-
(1997)
Pediatric Pulmonology
, vol.23
, Issue.5
, pp. 330-335
-
-
Frederiksen, B.1
Koch, C.2
Hoiby, N.3
-
20
-
-
59949089075
-
Hydrogen cyanide as a biomarker for Pseudomonas aeruginosa in the breath of children with cystic fibrosis
-
B. Enderby et al., "Hydrogen cyanide as a biomarker for Pseudomonas aeruginosa in the breath of children with cystic fibrosis, " Pediatr. Pulmonol. 44(2), 142-147 (2009).
-
(2009)
Pediatr. Pulmonol.
, vol.44
, Issue.2
, pp. 142-147
-
-
Enderby, B.1
-
21
-
-
79953677459
-
Cyanide in bronchoalveolar lavage is not diagnostic for Pseudomonas aeruginosa in children with cystic fibrosis
-
M. D. Stutz et al., "Cyanide in bronchoalveolar lavage is not diagnostic for Pseudomonas aeruginosa in children with cystic fibrosis, " Eur. Respir. J. 37(3), 553-558 (2011).
-
(2011)
Eur. Respir. J.
, vol.37
, Issue.3
, pp. 553-558
-
-
Stutz, M.D.1
-
22
-
-
79955946752
-
Volatile biomarkers of Pseudomonas aeruginosa in cystic fibrosis and noncystic fibrosis bronchiectasis
-
S. U. Savelev et al., "Volatile biomarkers of Pseudomonas aeruginosa in cystic fibrosis and noncystic fibrosis bronchiectasis, " Lett. Appl. Microbiol. 52(6), 610-613 (2011).
-
(2011)
Lett. Appl. Microbiol.
, vol.52
, Issue.6
, pp. 610-613
-
-
Savelev, S.U.1
-
23
-
-
33846845001
-
Hydrogen cyanide exhaust emissions from in-use motor vehicles
-
DOI 10.1021/es061402v
-
M. M. Baum et al., "Hydrogen cyanide exhaust emissions from in-use motor vehicles, " Environ. Sci. Technol. 41(3), 857-862 (2007). (Pubitemid 46208521)
-
(2007)
Environmental Science and Technology
, vol.41
, Issue.3
, pp. 857-862
-
-
Baum, M.M.1
Moss, J.A.2
Pastel, S.H.3
Poskrebyshev, G.A.4
-
24
-
-
70149122593
-
Background levels of hydrogen cyanide in human breath measured by infrared cavity ring down spectroscopy
-
K. Stamyr et al., "Background levels of hydrogen cyanide in human breath measured by infrared cavity ring down spectroscopy, " Biomarkers 14(5), 285-291 (2009).
-
(2009)
Biomarkers
, vol.14
, Issue.5
, pp. 285-291
-
-
Stamyr, K.1
-
25
-
-
77954216524
-
Recent developments in cyanide detection: A review
-
J. A. Ma and P. K. Dasgupta, "Recent developments in cyanide detection: a review, " Anal. Chem. Acta 673(2), 117-125 (2010).
-
(2010)
Anal. Chem. Acta
, vol.673
, Issue.2
, pp. 117-125
-
-
Ma, J.A.1
Dasgupta, P.K.2
-
26
-
-
41649117295
-
A highly sensitive and selective chemosensor for cyanide
-
J. Q. Ren, W. H. Zhu, and H. Tian, "A highly sensitive and selective chemosensor for cyanide, " Talanta 75(3), 760-764 (2008).
-
(2008)
Talanta
, vol.75
, Issue.3
, pp. 760-764
-
-
Ren, J.Q.1
Zhu, W.H.2
Tian, H.3
-
27
-
-
70649096182
-
A straightforward method for the colorimetric detection of endogenous biological cyanide
-
C. Mannel-Croise, B. Probst, and F. Zelder, "A straightforward method for the colorimetric detection of endogenous biological cyanide, " Anal. Chem. 81(22), 9493-9498 (2009).
-
(2009)
Anal. Chem.
, vol.81
, Issue.22
, pp. 9493-9498
-
-
Mannel-Croise, C.1
Probst, B.2
Zelder, F.3
-
28
-
-
77952512258
-
New facile method to measure cyanide in blood
-
W. C. Blackledge et al., "New facile method to measure cyanide in blood, " Anal. Chem. 82(10), 4216-4221 (2010).
-
(2010)
Anal. Chem.
, vol.82
, Issue.10
, pp. 4216-4221
-
-
Blackledge, W.C.1
-
29
-
-
33845335833
-
Headspace single-drop microextraction with in-drop derivatization and capillary electrophoretic determination for free cyanide analysis
-
DOI 10.1002/elps.200600295
-
S. Jermak, B. Pranaityte, and A. Padarauskas, "Headspace single-drop microextraction with in-drop derivatization and capillary electrophoretic determination for free cyanide analysis, " Electrophoresis 27(22), 4538-4544 (2006). (Pubitemid 44869608)
-
(2006)
Electrophoresis
, vol.27
, Issue.22
, pp. 4538-4544
-
-
Jermak, S.1
Pranaityte, B.2
Padarauskas, A.3
-
30
-
-
27144519265
-
Colorimetric detection of cyanide with a chromogenic oxazine
-
DOI 10.1021/ol051750m
-
M. Tomasulo and F. M. Raymo, "Colorimetric detection of cyanide with a chromogenic oxazine, " Org. Lett. 7(21), 4633-4636 (2005). (Pubitemid 41507059)
-
(2005)
Organic Letters
, vol.7
, Issue.21
, pp. 4633-4636
-
-
Tomasulo, M.1
Raymo, F.M.2
-
31
-
-
64349122735
-
Side chains of cobalt corrinoids control the sensitivity and selectivity in the colorimetric detection of cyanide
-
C. Mannel-Croise and F. Zelder, "Side chains of cobalt corrinoids control the sensitivity and selectivity in the colorimetric detection of cyanide, " Inorg. Chem. 48(4), 1272-1274 (2009).
-
(2009)
Inorg. Chem.
, vol.48
, Issue.4
, pp. 1272-1274
-
-
Mannel-Croise, C.1
Zelder, F.2
-
32
-
-
33744975438
-
Determination of cyanide in microliter samples by capillary electrophoresis and in-capillary enzymatic reaction with rhodanese
-
DOI 10.1016/j.chroma.2006.03.030, PII S0021967306005887, 29th International Symposium on High Performance Liquid Phase Separations and Related Techniques Part II
-
K. Papezova and Z. Glatz, "Determination of cyanide in microliter samples by capillary electrophoresis and in-capillary enzymatic reaction with rhodanese, " J. Chromatogr, A 1120(1-2), 268-272 (2006). (Pubitemid 43866773)
-
(2006)
Journal of Chromatography A
, vol.1120
, Issue.1-2
, pp. 268-272
-
-
Papezova, K.1
Glatz, Z.2
-
33
-
-
72049096674
-
Simultaneous derivatization and extraction of free cyanide in biological samples with home-made hollow fiber-protected headspace liquid-phase microextraction followed by capillary electrophoresis with UV detection
-
L. Meng et al., "Simultaneous derivatization and extraction of free cyanide in biological samples with home-made hollow fiber-protected headspace liquid-phase microextraction followed by capillary electrophoresis with UV detection, " J. Chromatogr., B 877(29), 3645-3651 (2009).
-
(2009)
J. Chromatogr. B
, vol.877
, Issue.29
, pp. 3645-3651
-
-
Meng, L.1
-
34
-
-
63649120764
-
Design of fluorescent assays for cyanide and hydrogen peroxide based on the inner filter effect of metal nanopar-ticles
-
L. Shang and S. J. Dong, "Design of fluorescent assays for cyanide and hydrogen peroxide based on the inner filter effect of metal nanopar-ticles, " Anal. Chem. 81(4), 1465-1470 (2009).
-
(2009)
Anal. Chem.
, vol.81
, Issue.4
, pp. 1465-1470
-
-
Shang, L.1
Dong, S.J.2
-
35
-
-
11144320672
-
A micro-chemiluminescence determination of cyanide in whole blood
-
DOI 10.1016/j.forsciint.2004.03.032, PII S0379073804002300
-
J. Lv et al., "A micro-chemiluminescence determination of cyanide in whole blood, " Forensic Sci. Int. 148(1), 15-19 (2005). (Pubitemid 40029391)
-
(2005)
Forensic Science International
, vol.148
, Issue.1
, pp. 15-19
-
-
Lv, J.1
Zhang, Z.2
Li, J.3
Luo, L.4
-
36
-
-
18844408629
-
A selective modified carbon paste electrode for determination of cyanide using tetra-3,4-pyridinoporphyrazinatocobalt(II)
-
DOI 10.1016/j.talanta.2004.12.062, PII S0039914004007490
-
A. Abbaspour et al., "A selective modified carbon paste electrode for determination of cyanide using tetra-3, 4-pyridinoporphyrazinatoco-balt(ii), " Talanta 66(4), 931-936 (2005). (Pubitemid 40690997)
-
(2005)
Talanta
, vol.66
, Issue.4
, pp. 931-936
-
-
Abbaspour, A.1
Asadi, M.2
Ghaffarinejad, A.3
Safaei, E.4
-
37
-
-
58149483717
-
Amperometric determination of cyanides at the low ppb level by automated preconcentration based on gas diffusion coupled to sequential injection analysis
-
C. K. Zacharis et al., "Amperometric determination of cyanides at the low ppb level by automated preconcentration based on gas diffusion coupled to sequential injection analysis, " Talanta 77(5), 1620-1626 (2009).
-
(2009)
Talanta
, vol.77
, Issue.5
, pp. 1620-1626
-
-
Zacharis, C.K.1
-
38
-
-
12344258819
-
Isotope dilution-mass spectrometry determination of blood cyanide by headspace gas chromatography
-
P. Dumas, G. Gingras, and A. LeBlanc, "Isotope dilution-mass spectrometry determination of blood cyanide by headspace gas chromatography, " J. Anal. Toxicol. 29(1), 71-75 (2005). (Pubitemid 40128950)
-
(2005)
Journal of Analytical Toxicology
, vol.29
, Issue.1
, pp. 71-75
-
-
Dumas, P.1
Gingras, G.2
LeBlanc, A.3
-
39
-
-
14744282134
-
110 GHz rapid, continuous tuning from an optical parametric oscillator pumped by a fiber-amplified DBR diode laser
-
I. Lindsay et al., "110 GHz rapid, continuous tuning from an optical parametric oscillator pumped by a fiber-amplified DBR diode laser, " Opt. Express 13(4), 1234-1239 (2005).
-
(2005)
Opt. Express
, vol.13
, Issue.4
, pp. 1234-1239
-
-
Lindsay, I.1
-
40
-
-
33749019125
-
Automatically tunable continuous-wave optical parametric oscillator for high-resolution spectroscopy and sensitive trace-gas detection
-
DOI 10.1007/s00340-006-2362-3, Optics: Trends in Laser Sources, Spectroscopic Techniques and their Applications to Trace Gas-Detection
-
A. K. Y. Ngai et al., "Automatically tunable continuous-wave optical parametric oscillator for high-resolution spectroscopy and sensitive trace-gas detection, " Appl. Phys. B 85(2-3), 173-180 (2006). (Pubitemid 44451330)
-
(2006)
Applied Physics B: Lasers and Optics
, vol.85
, Issue.2-3
, pp. 173-180
-
-
Ngai, A.K.Y.1
Persijn, S.T.2
Von Basum, G.3
Harren, F.J.M.4
-
41
-
-
34548582041
-
Continuous wave optical parametric oscillator for quartz-enhanced photoacoustic trace gas sensing
-
DOI 10.1007/s00340-007-2755-y
-
A. K. Y. Ngai et al., "Continuous wave optical parametric oscillator for quartz-enhanced photoacoustic trace gas sensing, " Appl. Phys. B 89(1), 123-128 (2007). (Pubitemid 47389529)
-
(2007)
Applied Physics B: Lasers and Optics
, vol.89
, Issue.1
, pp. 123-128
-
-
Ngai, A.K.Y.1
Persijn, S.T.2
Lindsay, I.D.3
Kosterev, A.A.4
Gross, P.5
Lee, C.J.6
Cristescu, S.M.7
Tittel, F.K.8
Boller, K.-J.9
Harren, F.J.M.10
-
42
-
-
79952318709
-
Compact, single-frequency, doubly resonant optical parametric oscillator pumped in an achromatic phase-adapted double-pass geometry
-
B. Hardy et al., "Compact, single-frequency, doubly resonant optical parametric oscillator pumped in an achromatic phase-adapted double-pass geometry, " Opt. Lett. 36(5), 678-680 (2011).
-
(2011)
Opt. Lett.
, vol.36
, Issue.5
, pp. 678-680
-
-
Hardy, B.1
-
43
-
-
0010921157
-
Environmental applications of laser-based photo-acoustic spectroscopy
-
M. Sigrist et al., "Environmental applications of laser-based photo-acoustic spectroscopy, " Anal. Sci. 17(S1), S511-S514 (2001).
-
(2001)
Anal. Sci.
, vol.17
, Issue.S1
-
-
Sigrist, M.1
-
44
-
-
33750965710
-
Extremely sensitive trace gas analysis with modern photoacoustic spectroscopy
-
DOI 10.1016/j.vibspec.2006.05.018, PII S0924203106001202, A Collection of Papers Presented at the 3rd International Conference on Advanced Vibrational Spectroscopy (ICAVS-3)Part 2
-
V. Koskinen et al., "Extremely sensitive trace gas analysis with modern photoacoustic spectroscopy, " Vib. Spectrosc. 42(2), 239-242 (2006). (Pubitemid 44738510)
-
(2006)
Vibrational Spectroscopy
, vol.42
, Issue.2
, pp. 239-242
-
-
Koskinen, V.1
Fonsen, J.2
Kauppinen, J.3
Kauppinen, I.4
-
45
-
-
50649092651
-
Laser-based systems for trace gas detection in life sciences
-
S. M. Cristescu et al., "Laser-based systems for trace gas detection in life sciences, " Appl. Phys. B 92(3), 343-349 (2008).
-
(2008)
Appl. Phys. B
, vol.92
, Issue.3
, pp. 343-349
-
-
Cristescu, S.M.1
-
46
-
-
82055206270
-
Real-time, subsecond, multicomponent breath analysis by optical parametric oscillator based off-axis integrated cavity output spectroscopy
-
D. D. Arslanov et al., "Real-time, subsecond, multicomponent breath analysis by optical parametric oscillator based off-axis integrated cavity output spectroscopy, " Opt. Express 19(24), 24078-24089 (2011).
-
(2011)
Opt. Express
, vol.19
, Issue.24
, pp. 24078-24089
-
-
Arslanov, D.D.1
-
47
-
-
39149099422
-
Trace gas monitoring with infrared laser-based detection schemes
-
M. W. Sigrist et al., "Trace gas monitoring with infrared laser-based detection schemes, " Appl. Phys. B 90(2), 289-300 (2008).
-
(2008)
Appl. Phys. B
, vol.90
, Issue.2
, pp. 289-300
-
-
Sigrist, M.W.1
-
48
-
-
70350375896
-
Breath analysis using laser spectroscopic techniques: Breath biomarkers, spectral finger-prints, and detection limits
-
C. Wang and P. Sahay, "Breath analysis using laser spectroscopic techniques: breath biomarkers, spectral finger-prints, and detection limits, " Sensors 9(10), 8230-8262 (2009).
-
(2009)
Sensors
, vol.9
, Issue.10
, pp. 8230-8262
-
-
Wang, C.1
Sahay, P.2
-
49
-
-
0035305186
-
Application of acoustic resonators in photoacoustic trace gas analysis and metrology
-
DOI 10.1063/1.1353198
-
A. Miklos and P. Hess, "Application of acoustic resonators in photoacoustic trace gas analysis and metrology, " Rev. Sci. Instrum. 72(4), 1937-1955 (2001). (Pubitemid 33606044)
-
(2001)
Review of Scientific Instruments
, vol.72
, Issue.4
, pp. 1937-1955
-
-
Miklos, A.1
Hess, P.2
Bozoki, Z.3
-
50
-
-
0037286101
-
Trace gas monitoring by laser photoacoustic spectroscopy and related techniques plenary
-
M. W. Sigrist, "Trace gas monitoring by laser photoacoustic spectroscopy and related techniques plenary, " Rev. Sci. Instrum. 74(1), 486-490 (2003).
-
(2003)
Rev. Sci. Instrum.
, vol.74
, Issue.1
, pp. 486-490
-
-
Sigrist, M.W.1
-
51
-
-
0036757887
-
Tuning and stability of a continuous-wave mid-infrared high-power single resonant optical parametric oscillator
-
DOI 10.1007/s00340-002-0989-2
-
M. van Herpen et al., "Tuning and stability of a continuous-wave mid-infrared high-power single resonant optical parametric oscillator, " Appl. Phys. B 75(2-3), 329-333 (2002). (Pubitemid 35354449)
-
(2002)
Applied Physics B: Lasers and Optics
, vol.75
, Issue.2-3
, pp. 329-333
-
-
Van Herpen, M.M.J.W.1
Li, S.2
Bisson, S.E.3
Te Lintel Hekkert, S.4
Harren, F.J.M.5
-
52
-
-
84874865823
-
Continuous-wave optical parametric oscillator based infrared spectroscopy for sensitive molecular gas sensing
-
D. D. Arslanov et al., "Continuous-wave optical parametric oscillator based infrared spectroscopy for sensitive molecular gas sensing, " Laser Photonics Rev. 7(2), 188-206 (2013).
-
(2013)
Laser Photonics Rev.
, vol.7
, Issue.2
, pp. 188-206
-
-
Arslanov, D.D.1
-
53
-
-
64449085988
-
The HITRAN 2008 molecular spectroscopic database
-
L. Rothman et al., "The HITRAN 2008 molecular spectroscopic database, " J. Quant. Spectrosc. Radiat. Transfer 110(9-10), 533-572 (2009).
-
(2009)
J. Quant. Spectrosc. Radiat. Transfer
, vol.110
, Issue.9-10
, pp. 533-572
-
-
Rothman, L.1
-
54
-
-
84867040975
-
Detection limits of chemical sensors: Applications and misapplications
-
H.-P Loock and P. D. Wentzell, "Detection limits of chemical sensors: applications and misapplications, " Sens. Actuators, B 173, 157-163 (2012).
-
(2012)
Sens. Actuators B
, vol.173
, pp. 157-163
-
-
Loock, H.-P.1
Wentzell, P.D.2
-
55
-
-
79953849290
-
Current status of midinfrared quantum and interband cascade lasers for clinical breath analysis
-
T H. Risby and F. K. Tittel, "Current status of midinfrared quantum and interband cascade lasers for clinical breath analysis, " Opt. Eng. 49(11), 111123 (2010).
-
(2010)
Opt. Eng.
, vol.49
, Issue.11
, pp. 111123
-
-
Risby, T.H.1
Tittel, F.K.2
-
56
-
-
79956267548
-
Proton transfer reaction mass spectrometry detects rapid changes in volatile metabolite emission by Mycobacterium smeg-matis after the addition of specific antimicrobial agents
-
E. Crespo et al., "Proton transfer reaction mass spectrometry detects rapid changes in volatile metabolite emission by Mycobacterium smeg-matis after the addition of specific antimicrobial agents, " J. Microbiol. Methods 86(1), 8-15 (2011).
-
(2011)
J. Microbiol. Methods
, vol.86
, Issue.1
, pp. 8-15
-
-
Crespo, E.1
|