메뉴 건너뛰기




Volumn 9, Issue 10, 2009, Pages 8230-8262

Breath analysis using laser spectroscopic techniques: Breath biomarkers, spectral fingerprints, and detection limits

Author keywords

Acetone; Biomarkers; Breath analysis; CALOS; Carbon dioxide; CEAS; CRDS; ICOS; Laser spectroscopic detection techniques; Nitric oxide; OFC ECAS; PAS; TDLAS

Indexed keywords

BREATH ANALYSIS; CALOS; CEAS; CRDS; ICOS; OFC-ECAS; PAS; SPECTROSCOPIC DETECTION; TDLAS;

EID: 70350375896     PISSN: 14248220     EISSN: None     Source Type: Journal    
DOI: 10.3390/s91008230     Document Type: Review
Times cited : (536)

References (167)
  • 1
    • 0015131404 scopus 로고
    • Quantitative analysis of urine vapor and breath by gas-liquid partition chromatography
    • Pauling, L.; Robinson, A.B.; Teranishi, R.; Cary, P. Quantitative analysis of urine vapor and breath by gas-liquid partition chromatography. Proc. Natl. Acad. Sci. USA 1971, 68, 2374-2384.
    • (1971) Proc. Natl. Acad. Sci. USA , vol.68 , pp. 2374-2384
    • Pauling, L.1    Robinson, A.B.2    Teranishi, R.3    Cary, P.4
  • 2
    • 0014633582 scopus 로고
    • Analysis of organic compounds in human breath by gas chromatography-mass spectrometry lab
    • Jansson, B.O.; Larsson, B.T.J. Analysis of organic compounds in human breath by gas chromatography-mass spectrometry lab. Clin. Med. 1969, 74, 961-966.
    • (1969) Clin. Med , vol.74 , pp. 961-966
    • Jansson, B.O.1    Larsson, B.T.J.2
  • 4
    • 0023750364 scopus 로고
    • Computerized classification technique for screening for the presence of breath biomarkers in lung cancer
    • O'Neill, H.; Gordon, S.M.; O'Neill, M.; Gibbons, R.D.; Szidon, J.P. A computerized classification technique for screening for the presence of breath biomarkers in lung cancer. Clin. Chem. 1988, 34, 1613-1618.
    • (1988) Clin. Chem , vol.34 , pp. 1613-1618
    • O'Neill, H.1    Gordon, S.M.2    O'Neill, M.3    Gibbons, R.D.4    Szidon, J.P.A.5
  • 6
    • 0031568680 scopus 로고    scopus 로고
    • Solid-phase microextraction for the analysis of human breath. Anal
    • Grote, C.; Pawliszyn, J. Solid-phase microextraction for the analysis of human breath. Anal. Chem. 1997, 69, 587-596.
    • (1997) Chem , vol.69 , pp. 587-596
    • Grote, C.1    Pawliszyn, J.2
  • 7
    • 0036829707 scopus 로고    scopus 로고
    • Breath analysis and monitoring by membrane extraction with sorbent interface
    • Lord, H.; Yu, Y.F.; Segal, A.; Pawliszyn, J. Breath analysis and monitoring by membrane extraction with sorbent interface. Anal. Chem. 2002, 74, 5650-5657.
    • (2002) Anal. Chem , vol.74 , pp. 5650-5657
    • Lord, H.1    Yu, Y.F.2    Segal, A.3    Pawliszyn, J.4
  • 8
    • 33645835176 scopus 로고    scopus 로고
    • Measuring airway exchange of endogenous acetone using a single-exhalation breathing maneuver
    • Anderson, J.C.; Lamm, W.J.E.; Hlasatala, M.P. Measuring airway exchange of endogenous acetone using a single-exhalation breathing maneuver. J. Appl. Physiol. 2005, 100, 880-889.
    • (2005) J. Appl. Physiol , vol.100 , pp. 880-889
    • Anderson, J.C.1    Lamm, W.J.E.2    Hlasatala, M.P.3
  • 9
    • 0025245413 scopus 로고
    • Device for sampling of human alveolar breath for the measurement of expired volatile organic compounds
    • Raymer, J.H.; Thomas, K.W.; Cooper, S.D.; Whitaker, D.A.; Pellizzari, E.D. A device for sampling of human alveolar breath for the measurement of expired volatile organic compounds. J. Anal. Toxicol. 1990, 14, 337-344.
    • (1990) J. Anal. Toxicol , vol.14 , pp. 337-344
    • Raymer, J.H.1    Thomas, K.W.2    Cooper, S.D.3    Whitaker, D.A.4    Pellizzari, E.D.A.5
  • 10
    • 0028103871 scopus 로고
    • Pentane and isoprene in expired air from humans: Gas-chromatographic analysis of single breath
    • Mendis, S.; Sobotka, P.A.; Euler, D.E. Pentane and isoprene in expired air from humans: gas-chromatographic analysis of single breath. Clin. Chem. 1994, 40, 1485-1488.
    • (1994) Clin. Chem. , vol.40 , pp. 1485-1488
    • Mendis, S.1    Sobotka, P.A.2    Euler, D.E.3
  • 11
    • 0343742253 scopus 로고
    • Acetone in the breath; A study of acetone exhalation in diabetic and nondiabetic human subjects
    • Henderson, M.J.; Karger, B.A.; Wrenshall, G.A. Acetone in the breath; A study of acetone exhalation in diabetic and nondiabetic human subjects. Diabetes 1952, 1, 188-193.
    • (1952) Diabetes , vol.1 , pp. 188-193
    • Henderson, M.J.1    Karger, B.A.2    Wrenshall, G.A.3
  • 12
    • 0031149661 scopus 로고    scopus 로고
    • Method for the collection and assay of volatile organic compounds in breath
    • Phillips, M. Method for the collection and assay of volatile organic compounds in breath. Anal. Biochem. 1997, 247, 272-278.
    • (1997) Anal. Biochem , vol.247 , pp. 272-278
    • Phillips, M.1
  • 15
    • 0344668784 scopus 로고    scopus 로고
    • Real-time breath monitoring of propane and its volatile metabolites during surgery using a novel mass spectrometric technique: A feasibility study
    • Harrison, G.R.; Critchley, A.D.; Mayhew, C.A.; Thompson, J.M. Real-time breath monitoring of propane and its volatile metabolites during surgery using a novel mass spectrometric technique: a feasibility study. Br. J. Anaesth. 2003, 91, 797-799.
    • (2003) Br. J. Anaesth. , vol.91 , pp. 797-799
    • Harrison, G.R.1    Critchley, A.D.2    Mayhew, C.A.3    Thompson, J.M.4
  • 16
    • 0034469369 scopus 로고    scopus 로고
    • Automated in-tube solid phase microextraction coupled with liquid chromatography-electrospray ionization mass spectrometry for the determination of selected benzodiazepines
    • Yuan, H.; Mester, Z.; Lord, H.; Pawliszyn, J. Automated in-tube solid phase microextraction coupled with liquid chromatography-electrospray ionization mass spectrometry for the determination of selected benzodiazepines. J. Anal. Toxicol. 2000, 24, 718-725.
    • (2000) J. Anal. Toxicol , vol.24 , pp. 718-725
    • Yuan, H.1    Mester, Z.2    Lord, H.3    Pawliszyn, J.4
  • 17
    • 22044456844 scopus 로고    scopus 로고
    • Detection of human metabolites using multi-capillary columns coupled to ion mobility spectrometers
    • Ruzsanyi, V.; Baumbach, J.; Litterst, P.; Westhoff, M.; Freitag, L. Detection of human metabolites using multi-capillary columns coupled to ion mobility spectrometers. J. Chromatogr. A 2005, 1084, 145-151.
    • (2005) J. Chromatogr. A , vol.1084 , pp. 145-151
    • Ruzsanyi, V.1    Baumbach, J.2    Litterst, P.3    Westhoff, M.4    Freitag, L.5
  • 18
    • 0036667790 scopus 로고    scopus 로고
    • On-line, simultaneous quantification of ethanol, some metabolites and water vapour in breath following the ingestion of alcohol
    • Smith, D.; Wang, T.; Spanel, P. On-line, simultaneous quantification of ethanol, some metabolites and water vapour in breath following the ingestion of alcohol. Physiol. Meas. 2002, 23, 477-479.
    • (2002) Physiol. Meas , vol.23 , pp. 477-479
    • Smith, D.1    Wang, T.2    Spanel, P.3
  • 19
    • 0037296006 scopus 로고    scopus 로고
    • Time variation of ammonia, acetone, isoprene and ethanol in breath: A quantitative SIFT-MS study over 30 days
    • Diskin, A.M.; Spanel, P.; Smith, D. Time variation of ammonia, acetone, isoprene and ethanol in breath: a quantitative SIFT-MS study over 30 days. Physiol. Meas. 2003, 24, 107-120.
    • (2003) Physiol. Meas. , vol.24 , pp. 107-120
    • Diskin, A.M.1    Spanel, P.2    Smith, D.3
  • 20
    • 33645003060 scopus 로고    scopus 로고
    • Longitudinal study of ammonia, acetone and propanol in the exhaled breath of 30 subjects using selected ion flow tube mass spectrometry SIFT-MS
    • Turner, C.; Spanel, P.; Smith, D. A longitudinal study of ammonia, acetone and propanol in the exhaled breath of 30 subjects using selected ion flow tube mass spectrometry SIFT-MS. Physiol. Meas. 2006, 27, 321-337.
    • (2006) Physiol. Meas , vol.27 , pp. 321-337
    • Turner, C.1    Spanel, P.2    Smith, D.A.3
  • 21
    • 17444399677 scopus 로고    scopus 로고
    • Selected ion flow tube mass spectrometry (SIFT-MS) for on-line trace gas analysis
    • Smith, D.; Spanel, P. Selected ion flow tube mass spectrometry (SIFT-MS) for on-line trace gas analysis. Mass Spectrom. Rev. 2005, 24, 661-700.
    • (2005) Mass Spectrom. Rev , vol.24 , pp. 661-700
    • Smith, D.1    Spanel, P.2
  • 25
    • 84919497866 scopus 로고    scopus 로고
    • Recent advances of laser-spectroscopy-based techniques for applications in breath analysis
    • 014001/1-12
    • McCurdy, M. R.; Bakhirkin, Y.; Wysocki, G.; Lewicki, R.; Tittel, F.K. Recent advances of laser-spectroscopy-based techniques for applications in breath analysis. J. Breath Res. 2007, 1, 014001/1-12.
    • (2007) J. Breath Res. , vol.1
    • McCurdy, M.R.1    Bakhirkin, Y.2    Wysocki, G.3    Lewicki, R.4    Tittel, F.K.5
  • 27
    • 11844286343 scopus 로고    scopus 로고
    • Breath diagnostics using laser spectroscopy
    • Mürtz, M. Breath diagnostics using laser spectroscopy. Opt. Photon. News 2005, 16, 30-35.
    • (2005) Opt. Photon. News , vol.16 , pp. 30-35
    • Mürtz, M.1
  • 28
    • 33746216893 scopus 로고    scopus 로고
    • From highly sophisticated analytical techniques to life-saving diagnostics: Technical developments in breath analysis
    • Miekisch, W.; Schubert, J. From highly sophisticated analytical techniques to life-saving diagnostics: Technical developments in breath analysis. Trends Anal. Chem. 2006, 25, 665-673.
    • (2006) Trends Anal. Chem. , vol.25 , pp. 665-673
    • Miekisch, W.1    Schubert, J.2
  • 29
    • 34247624670 scopus 로고    scopus 로고
    • The challenge of breath analysis for clinical diagnosis and therapeutic monitoring
    • Smith, D.; Spanel, P. The challenge of breath analysis for clinical diagnosis and therapeutic monitoring. Analyst 2007, 132, 390-396.
    • (2007) Analyst , vol.132 , pp. 390-396
    • Smith, D.1    Spanel, P.2
  • 30
    • 33847639202 scopus 로고    scopus 로고
    • Current status of methods and techniques for breath analysis
    • Cao, W.; Duan, Y. Current status of methods and techniques for breath analysis. Critical Rev. Anal. Chem. 2007, 37, 3-13.
    • (2007) Critical Rev. Anal. Chem , vol.37 , pp. 3-13
    • Cao, W.1    Duan, Y.2
  • 31
    • 0001406682 scopus 로고    scopus 로고
    • Tunable diode-laser absorption measurements of NO2 near 670 and 395 nm
    • Mihalcea, R.M.; Baer, D.S.; Hanson, R.K. Tunable diode-laser absorption measurements of NO2 near 670 and 395 nm. Appl. Opt. 1996, 35, 4059-4064.
    • (1996) Appl. Opt , vol.35 , pp. 4059-4064
    • Mihalcea, R.M.1    Baer, D.S.2    Hanson, R.K.3
  • 32
    • 0028545917 scopus 로고
    • Multiplexed diode-laser sensor system for simultaneous H2O, O2, and temperature measurements
    • Baer, D.S.; Hanson, R.K.; Newfield, M.E.; Gopaul, N.K.L.M. Multiplexed diode-laser sensor system for simultaneous H2O, O2, and temperature measurements. Opt. Lett. 1994, 19, 1900-1902.
    • (1994) Opt. Lett , vol.19 , pp. 1900-1902
    • Baer, D.S.1    Hanson, R.K.2    Newfield, M.E.3    Gopaul, N.K.L.M.4
  • 33
    • 29144464162 scopus 로고
    • Cavity ring-down optical spectrometer for absorption measurements using pulsed laser sources
    • O'Keefe, A.; Deacon, D.A.G. Cavity ring-down optical spectrometer for absorption measurements using pulsed laser sources. Rev. Sci. Instrum. 1988, 59, 2544-2551.
    • (1988) Rev. Sci. Instrum , vol.59 , pp. 2544-2551
    • O'Keefe, A.1    Deacon, D.A.G.2
  • 35
    • 0034536080 scopus 로고    scopus 로고
    • Cavity ring-down spectroscopy: Experimental schemes and applications
    • Berden, G.; Peeters, R.; Meijer, G. Cavity ring-down spectroscopy: Experimental schemes and applications. Int. Rev. Phys. Chem. 2000, 19, 565-607.
    • (2000) Int. Rev. Phys. Chem. , vol.19 , pp. 565-607
    • Berden, G.1    Peeters, R.2    Meijer, G.3
  • 37
    • 0013400697 scopus 로고    scopus 로고
    • Broadband ringdown spectral photography
    • Scherer, J.J.; Paul, J.B.; Jiao, H.; O'Keefe, A. Broadband ringdown spectral photography. Appl. Opt. 2001, 40, 6725-6732.
    • (2001) Appl. Opt , vol.40 , pp. 6725-6732
    • Scherer, J.J.1    Paul, J.B.2    Jiao, H.3    O'Keefe, A.4
  • 38
    • 0036757006 scopus 로고    scopus 로고
    • Sensitive absorption measurements in the near-infrared region using off-axis integrated-cavity-output spectroscopy
    • Baer, D.S.; Paul, J.B.; Gupta, J.B.; O'Keefe, A. Sensitive absorption measurements in the near-infrared region using off-axis integrated-cavity-output spectroscopy. Appl. Phys. B: Lasers Opt. 2002, 75, 261-265.
    • (2002) Appl. Phys. B: Lasers Opt , vol.75 , pp. 261-265
    • Baer, D.S.1    Paul, J.B.2    Gupta, J.B.3    O'Keefe, A.4
  • 39
    • 2342584132 scopus 로고    scopus 로고
    • Mid-infrared quantum cascade laser based off-axis integrated cavity output spectroscopy for biogenic nitric oxide detection
    • Bakhirkin, Y.A.; Kosterev, A.A.; Roller, C.; Curl, R.F.; Tittel, F.K. Mid-infrared quantum cascade laser based off-axis integrated cavity output spectroscopy for biogenic nitric oxide detection. Appl. Opt. 2004, 43, 2257-2266.
    • (2004) Appl. Opt , vol.43 , pp. 2257-2266
    • Bakhirkin, Y.A.1    Kosterev, A.A.2    Roller, C.3    Curl, R.F.4    Tittel, F.K.5
  • 40
    • 29044437356 scopus 로고    scopus 로고
    • Sub ppbv nitric oxide concentration measurements using cw thermoelectrically cooled quantum cascade laser-based integrated cavity output spectroscopy
    • Bakhirkin, Y.A.; Kosterev, A.A.; Curl, R.; Tittel, F.K.; Yarekha, D.A.; Hvozdara, L.; Giovannini, M.; Faist, J. Sub ppbv nitric oxide concentration measurements using cw thermoelectrically cooled quantum cascade laser-based integrated cavity output spectroscopy. Appl. Phys. B: Lasers Opt. 2006, 82, 149-154.
    • (2006) Appl. Phys. B: Lasers Opt , vol.82 , pp. 149-154
    • Bakhirkin, Y.A.1    Kosterev, A.A.2    Curl, R.3    Tittel, F.K.4    Yarekha, D.A.5    Hvozdara, L.6    Giovannini, M.7    Faist, J.8
  • 41
    • 0002773698 scopus 로고    scopus 로고
    • Open-path trace gas detection of ammonia based on cavity-enhanced absorption spectroscopy
    • Peeters, R.; Berden, G.; Apituley, A.; Meijer, G. Open-path trace gas detection of ammonia based on cavity-enhanced absorption spectroscopy. Appl. Phys. B: Lasers Opt. 2000, 71, 231-236.
    • (2000) Appl. Phys. B: Lasers Opt , vol.71 , pp. 231-236
    • Peeters, R.1    Berden, G.2    Apituley, A.3    Meijer, G.4
  • 42
    • 0034807561 scopus 로고    scopus 로고
    • Real-time monitoring of ethane in human breath using mid-infrared cavity leak-out spectroscopy
    • Dahnke, H.; Kleine, D.; Hering, P.; Mürtz, M. Real-time monitoring of ethane in human breath using mid-infrared cavity leak-out spectroscopy. Appl. Phys. B: Lasers Opt. 2001, 72, 971-975.
    • (2001) Appl. Phys. B: Lasers Opt , vol.72 , pp. 971-975
    • Dahnke, H.1    Kleine, D.2    Hering, P.3    Mürtz, M.4
  • 43
    • 0034812054 scopus 로고    scopus 로고
    • Isotopic ratio measurement of methane in ambient air using mid-infrared cavity leak-out spectroscopy
    • Dahnke, H.; Kleine, D.; Urban, C.; Hering, P.; Murtz, M. Isotopic ratio measurement of methane in ambient air using mid-infrared cavity leak-out spectroscopy. Appl. Phys. B: Lasers Opt. 2001, 72, 121-125.
    • (2001) Appl. Phys. B: Lasers Opt , vol.72 , pp. 121-125
    • Dahnke, H.1    Kleine, D.2    Urban, C.3    Hering, P.4    Murtz, M.5
  • 44
    • 1942424116 scopus 로고    scopus 로고
    • Parts per trillion sensitivity for ethane in air with an optical parametric oscillator cavity leak-out spectrometer
    • von Basum, G.; Halmer, D.; Hering, P.; Murtz, M.; Schiller, S.; Mueller, F.; Popp, A.; Kuehnemann, F. Parts per trillion sensitivity for ethane in air with an optical parametric oscillator cavity leak-out spectrometer. Opt. Lett. 2004, 29, 797-799.
    • (2004) Opt. Lett , vol.29 , pp. 797-799
    • von Basum, G.1    Halmer, D.2    Hering, P.3    Murtz, M.4    Schiller, S.5    Mueller, F.6    Popp, A.7    Kuehnemann, F.8
  • 45
    • 33749005133 scopus 로고    scopus 로고
    • Online monitoring of ethane traces in exhaled breath with a difference frequency generation spectrometer
    • Halmer, D.; Thelen, S.; Hering, P.; Mürtz, M. Online monitoring of ethane traces in exhaled breath with a difference frequency generation spectrometer. Appl. Phys. B: Lasers Opt. 2006, 85, 437-443.
    • (2006) Appl. Phys. B: Lasers Opt , vol.85 , pp. 437-443
    • Halmer, D.1    Thelen, S.2    Hering, P.3    Mürtz, M.4
  • 46
    • 25144518792 scopus 로고    scopus 로고
    • Mid-infrared cavity leak-out spectroscopy for ultrasensitive detection of carbonyl sulfide
    • Halmer, D.; von Basum, G.; Hering, P.; Murtz, M. Mid-infrared cavity leak-out spectroscopy for ultrasensitive detection of carbonyl sulfide. Opt. Lett. 2005, 30, 2314-2316.
    • (2005) Opt. Lett , vol.30 , pp. 2314-2316
    • Halmer, D.1    von Basum, G.2    Hering, P.3    Murtz, M.4
  • 47
    • 0001092650 scopus 로고    scopus 로고
    • Photoacoustic spectroscopy with quantum cascade distributed-feedback lasers
    • Hofstetter, D.; Beck, M.; Faist, J.; Nagele, M.; Sigrist, M.W. Photoacoustic spectroscopy with quantum cascade distributed-feedback lasers. Opt. Lett. 2001, 26, 887-889.
    • (2001) Opt. Lett , vol.26 , pp. 887-889
    • Hofstetter, D.1    Beck, M.2    Faist, J.3    Nagele, M.4    Sigrist, M.W.5
  • 49
    • 33645052979 scopus 로고    scopus 로고
    • Broadband cavity ringdown spectroscopy for sensitive and rapid molecular detection
    • Thorpe, M.J.; Moll, K.D.; Jones, J.R.; Safdi, B.; Ye, J. Broadband cavity ringdown spectroscopy for sensitive and rapid molecular detection. Science 2006, 311, 1595-1599.
    • (2006) Science , vol.311 , pp. 1595-1599
    • Thorpe, M.J.1    Moll, K.D.2    Jones, J.R.3    Safdi, B.4    Ye, J.5
  • 50
    • 39749110134 scopus 로고    scopus 로고
    • Cavity-enhanced optical frequency comb spectroscopy: Application to human breath analysis
    • Thorpe, M.J.; Balslev-Clausen, D.; Kirchner, M.S.; Ye, J. Cavity-enhanced optical frequency comb spectroscopy: application to human breath analysis. Opt. Express 2008, 16, 2387-2397.
    • (2008) Opt. Express , vol.16 , pp. 2387-2397
    • Thorpe, M.J.1    Balslev-Clausen, D.2    Kirchner, M.S.3    Ye, J.4
  • 51
    • 7944239290 scopus 로고    scopus 로고
    • Nitric oxide, nitrotyrosine, and nitric oxide modulators in asthma and chronic obstructive pulmonary disease
    • Kharitonov, S.A.; Barnes, P.J. Nitric oxide, nitrotyrosine, and nitric oxide modulators in asthma and chronic obstructive pulmonary disease. Curr. Allergy Asthma Rep. 2003, 3, 121-129.
    • (2003) Curr. Allergy Asthma Rep , vol.3 , pp. 121-129
    • Kharitonov, S.A.1    Barnes, P.J.2
  • 54
    • 0030098644 scopus 로고    scopus 로고
    • Increased levels of exhaled nitric oxide during nasal and oral breathing in subjects with seasonal rhinitis
    • Martin, U.; Bryden, K.; Devoy, M.; Howarth, P. Increased levels of exhaled nitric oxide during nasal and oral breathing in subjects with seasonal rhinitis. J. Allergy Clin. Immunol. 1996, 97, 768-772.
    • (1996) J. Allergy Clin. Immunol , vol.97 , pp. 768-772
    • Martin, U.1    Bryden, K.2    Devoy, M.3    Howarth, P.4
  • 55
    • 0026047596 scopus 로고
    • Utility of breath ethane as a noninvasive biomarker of vitamin E status in children
    • Refat, M.; Moore, T.J.; Kazui, M.; Risby, T.H.; Perman, J.A.; Schwarz, K.B. Utility of breath ethane as a noninvasive biomarker of vitamin E status in children. Pediatr. Res. 1991, 30, 396-403.
    • (1991) Pediatr. Res , vol.30 , pp. 396-403
    • Refat, M.1    Moore, T.J.2    Kazui, M.3    Risby, T.H.4    Perman, J.A.5    Schwarz, K.B.6
  • 56
    • 0015952772 scopus 로고
    • Ethane evolution: A new index of lipid peroxidation
    • Riely, C.A.; Cohen, G.; Lieberman, M. Ethane evolution: a new index of lipid peroxidation. Science 1974, 183, 208-210.
    • (1974) Science , vol.183 , pp. 208-210
    • Riely, C.A.1    Cohen, G.2    Lieberman, M.3
  • 57
    • 0020315963 scopus 로고
    • Ethane exhalation as an index of in vivo lipid peroxidation: Concentrating ethane from a breath collection chamber
    • Lawrence, G.D.; Cohen, G. Ethane exhalation as an index of in vivo lipid peroxidation: concentrating ethane from a breath collection chamber. Anal. Biochem. 1982, 122, 283-290.
    • (1982) Anal. Biochem. , vol.122 , pp. 283-290
    • Lawrence, G.D.1    Cohen, G.2
  • 59
    • 0031040970 scopus 로고    scopus 로고
    • Hydrogen peroxide in exhaled air is increased in stable asthmatic children
    • Jobsis, Q.; Raatgeep, H.C.; Hermans, P.W.; de Jongste, J.C. Hydrogen peroxide in exhaled air is increased in stable asthmatic children. Eur. Respir. J. 1997, 10, 519-521.
    • (1997) Eur. Respir. J , vol.10 , pp. 519-521
    • Jobsis, Q.1    Raatgeep, H.C.2    Hermans, P.W.3    de Jongste, J.C.4
  • 61
    • 0028277936 scopus 로고
    • The potential of the hydrocarbon breath test as a measure of lipid peroxidation. Free Radic
    • Kneepkens, C.M.; Lepage, G.; Roy, C.C. The potential of the hydrocarbon breath test as a measure of lipid peroxidation. Free Radic. Biol. Med. 1994, 17, 127-160.
    • (1994) Biol. Med , vol.17 , pp. 127-160
    • Kneepkens, C.M.1    Lepage, G.2    Roy, C.C.3
  • 62
    • 68849121023 scopus 로고    scopus 로고
    • Breath pentane: An indicator for early and continuous monitoring of lipid peroxidation in hepatic ischaemia-reperfusion injury
    • Li, P.; Xu, G.; Wang, C.; Gong, Y.; He, Y. Breath pentane: an indicator for early and continuous monitoring of lipid peroxidation in hepatic ischaemia-reperfusion injury. Eur. J. Anaesthesiol. 2009, 26, 513-519.
    • (2009) Eur. J. Anaesthesiol. , vol.26 , pp. 513-519
    • Li, P.1    Xu, G.2    Wang, C.3    Gong, Y.4    He, Y.5
  • 63
    • 0027430206 scopus 로고
    • Increased pentane and carbon disulfide in the breath of patients with schizophrenia
    • Phillips, M.; Sabas, M.; Greenberg, J. Increased pentane and carbon disulfide in the breath of patients with schizophrenia. J. Clin. Pathol. 1993, 46, 861-864.
    • (1993) J. Clin. Pathol , vol.46 , pp. 861-864
    • Phillips, M.1    Sabas, M.2    Greenberg, J.3
  • 64
    • 12144290029 scopus 로고    scopus 로고
    • The HITRAN molecular spectroscopic database: Edition of 2000 including updates through 2001
    • Rothman, L.S.; Barbe, A.; Benner, D.C. The HITRAN molecular spectroscopic database: edition of 2000 including updates through 2001. J. Quant. Spectrosc. Radiat. Transfer 2003, 82, 5-44.
    • (2003) J. Quant. Spectrosc. Radiat. Transfer , vol.82 , pp. 5-44
    • Rothman, L.S.1    Barbe, A.2    Benner, D.C.3
  • 65
    • 10944226055 scopus 로고    scopus 로고
    • Large-modulation-depth 2f spectroscopy with diode lasers for rapid temperature and species measurements in gases with blended and broadened spectra
    • For example
    • For example: Liu, J.T.C.; Jeffries, J.B.; Hanson, R.K. Large-modulation-depth 2f spectroscopy with diode lasers for rapid temperature and species measurements in gases with blended and broadened spectra. Appl. Opt. 2004, 43, 6500-6509.
    • (2004) Appl. Opt. , vol.43 , pp. 6500-6509
    • Liu, J.T.C.1    Jeffries, J.B.2    Hanson, R.K.3
  • 66
    • 0035979607 scopus 로고    scopus 로고
    • Wavelength modulation absorption spectrometry - An extensive scrutiny of the generation of signals. Spectrochim
    • Kluczynski, P.; Gustafsson, J.; Lindberg, A.M.; Axner, O. Wavelength modulation absorption spectrometry - an extensive scrutiny of the generation of signals. Spectrochim. Acta B 2001, 56, 1277-1354.
    • (2001) Acta B , vol.56 , pp. 1277-1354
    • Kluczynski, P.1    Gustafsson, J.2    Lindberg, A.M.3    Axner, O.4
  • 67
    • 0035305186 scopus 로고    scopus 로고
    • Application of acoustic resonators in photoacoustic trace gas analysis and metrology
    • Miklos, A.; Hess P.; Bozoki, Z. Application of acoustic resonators in photoacoustic trace gas analysis and metrology. Rev. Sci. Instru. 2001, 72, 1937-1955.
    • (2001) Rev. Sci. Instru , vol.72 , pp. 1937-1955
    • Miklos, A.1    Hess, P.2    Bozoki, Z.3
  • 68
    • 0030400086 scopus 로고    scopus 로고
    • Sensitive trace gas detection with near-infrared laser diode and an integrating sphere
    • Tranchart, S.; Bachir, I.H.; Destomber, J.L. Sensitive trace gas detection with near-infrared laser diode and an integrating sphere. Appl. Opt. 1996, 35, 7070-7074.
    • (1996) Appl. Opt , vol.35 , pp. 7070-7074
    • Tranchart, S.1    Bachir, I.H.2    Destomber, J.L.3
  • 69
    • 0037374718 scopus 로고    scopus 로고
    • Tunable diode laser absorption spectrometer measurements of ambient nitrogen dioxide, nitric acid, formaldehyde, and hydrogen peroxide in Parlier, California
    • Sauer, C.G.; Pisano, J.T.; Fitz, D.R. Tunable diode laser absorption spectrometer measurements of ambient nitrogen dioxide, nitric acid, formaldehyde, and hydrogen peroxide in Parlier, California. Atmos. Environ. 2003, 37, 1583-1591.
    • (2003) Atmos. Environ , vol.37 , pp. 1583-1591
    • Sauer, C.G.1    Pisano, J.T.2    Fitz, D.R.3
  • 70
    • 0000605771 scopus 로고
    • Ring-down cavity absorption spectroscopy of the very weak HCN overtone bands with six, seven, and eight stretching quanta
    • Romanini, D.; Lehmann, K.K. Ring-down cavity absorption spectroscopy of the very weak HCN overtone bands with six, seven, and eight stretching quanta. J. Chem. Phys. 1993, 99, 6287-6301.
    • (1993) J. Chem. Phys , vol.99 , pp. 6287-6301
    • Romanini, D.1    Lehmann, K.K.2
  • 71
    • 33749035471 scopus 로고    scopus 로고
    • Impact of humidity on quartz-enhanced photoacoustic spectroscopy based detection of HCN
    • Kosterev, A.A.; Mosely, T.S.; Tittel, F.K. Impact of humidity on quartz-enhanced photoacoustic spectroscopy based detection of HCN. Appl. Phys. B: Lasers Opt. 2006, 85, 295-300.
    • (2006) Appl. Phys. B: Lasers Opt , vol.85 , pp. 295-300
    • Kosterev, A.A.1    Mosely, T.S.2    Tittel, F.K.3
  • 72
    • 39149085703 scopus 로고    scopus 로고
    • H2S trace concentration measurements using off-axis integrated cavity output spectroscopy in the near-infrared. Appl. Phys
    • Chen, W.; Kosterev, A.A.; Tittel, F.K.; Gao, X.; Zhao, W. H2S trace concentration measurements using off-axis integrated cavity output spectroscopy in the near-infrared. Appl. Phys. B: Lasers Opt. 2008, 90, 311-315.
    • (2008) B: Lasers Opt , vol.90 , pp. 311-315
    • Chen, W.1    Kosterev, A.A.2    Tittel, F.K.3    Gao, X.4    Zhao, W.5
  • 74
    • 33748991745 scopus 로고    scopus 로고
    • Photoacoustic system for on-line process monitoring of hydrogen sulfide (H2S) concentration in natural gas streams. Appl. Phys
    • Varga, A.; Bozoki, Z.; Szakall, M.; Szabo, G. Photoacoustic system for on-line process monitoring of hydrogen sulfide (H2S) concentration in natural gas streams. Appl. Phys. B: Lasers Opt. 2006, 85, 315-321.
    • (2006) B: Lasers Opt , vol.85 , pp. 315-321
    • Varga, A.1    Bozoki, Z.2    Szakall, M.3    Szabo, G.4
  • 76
    • 34547420208 scopus 로고    scopus 로고
    • A new acetone detection device using cavity ringdown spectroscopy at 266 nm: Evaluation of the instrument performance using acetone sample solutions
    • Wang, C.; Mbi, A. A new acetone detection device using cavity ringdown spectroscopy at 266 nm: evaluation of the instrument performance using acetone sample solutions. Meas. Sci. Technol. 2007, 18, 2731-2741.
    • (2007) Meas. Sci. Technol. , vol.18 , pp. 2731-2741
    • Wang, C.1    Mbi, A.2
  • 77
    • 72349088828 scopus 로고    scopus 로고
    • Study on breath acetone in diabetic patients using a cavity ringdown breath analyzer: Exploring correlations of breath acetone with blood glucose and glycohemoglobin A1C
    • (in press)
    • Wang, C.; Mbi, A.; Shepherd, M. A study on breath acetone in diabetic patients using a cavity ringdown breath analyzer: Exploring correlations of breath acetone with blood glucose and glycohemoglobin A1C. IEEE Sens. J. 2009, (in press).
    • (2009) IEEE Sens. J.
    • Wang, C.1    Mbi, A.2    Shepherd, M.A.3
  • 78
    • 58149292020 scopus 로고    scopus 로고
    • An acetone breath analyzer using cavity ringdown spectroscopy: An initial test with human subjects under various situations
    • Wang, C.; Surampudi, A.B. An acetone breath analyzer using cavity ringdown spectroscopy: an initial test with human subjects under various situations. Meas. Sci. Technol. 2008, 19, 105604-105614.
    • (2008) Meas. Sci. Technol. , vol.19 , pp. 105604-105614
    • Wang, C.1    Surampudi, A.B.2
  • 79
    • 0035836626 scopus 로고    scopus 로고
    • Correlation of breath ammonia with blood urea nitrogen and creatinine during hemodialysis
    • Narasimhan, L.R.; Goodman, W.; Patel, C.K.N. Correlation of breath ammonia with blood urea nitrogen and creatinine during hemodialysis. Proc. Natl. Acad. Sci. USA 2001, 98, 4617-4621.
    • (2001) Proc. Natl. Acad. Sci. USA , vol.98 , pp. 4617-4621
    • Narasimhan, L.R.1    Goodman, W.2    Patel, C.K.N.3
  • 80
    • 0041020957 scopus 로고
    • Tunable diode laser based spectroscopic system for ammonia detection in human respiration
    • Lachish, U.; Rotter, S.; Adler, E.; El-Hanany, U. Tunable diode laser based spectroscopic system for ammonia detection in human respiration. Rev. Sci. Instrum. 1987, 58, 923-927.
    • (1987) Rev. Sci. Instrum , vol.58 , pp. 923-927
    • Lachish, U.1    Rotter, S.2    Adler, E.3    El-Hanany, U.4
  • 81
    • 33846885425 scopus 로고    scopus 로고
    • Pulsed quantum cascade laser-based cavity ring-down spectroscopy for ammonia detection in breath
    • Manne, J.; Sukhorukov, O.; Jager, W.; Tulip, J. Pulsed quantum cascade laser-based cavity ring-down spectroscopy for ammonia detection in breath. Appl. Opt. 2006, 45, 9230-9237.
    • (2006) Appl. Opt , vol.45 , pp. 9230-9237
    • Manne, J.1    Sukhorukov, O.2    Jager, W.3    Tulip, J.4
  • 82
    • 58349123080 scopus 로고    scopus 로고
    • Sensitive detection of ammonia and ethylene with a pulsed quantum cascade laser using intra and interpulse spectroscopic techniques
    • Manne, J.; Jager, W.; Tulip, J. Sensitive detection of ammonia and ethylene with a pulsed quantum cascade laser using intra and interpulse spectroscopic techniques. Appl. Phys. B: Lasers Opt. 2009, 94, 337-344.
    • (2009) Appl. Phys. B: Lasers Opt , vol.94 , pp. 337-344
    • Manne, J.1    Jager, W.2    Tulip, J.3
  • 83
    • 0030082070 scopus 로고    scopus 로고
    • Human breath trace gas content study by tunable diode laser spectroscopy technique
    • Moskalenko, K.L.; Nadezhdinskii, A.I.; Adamovskaya, I.A. Human breath trace gas content study by tunable diode laser spectroscopy technique. Infrared Phys. Tech. 1996, 37, 181-192.
    • (1996) Infrared Phys. Tech , vol.37 , pp. 181-192
    • Moskalenko, K.L.1    Nadezhdinskii, A.I.2    Adamovskaya, I.A.3
  • 84
    • 32844474285 scopus 로고    scopus 로고
    • Optical parametric oscillator-based photoacoustic detection of CO2 at 4.23 μm allows real-time monitoring of the respiration of small insects
    • Van Herpen, M.M.J.W.; Ngai, A.K.Y.; Bisson, S.E.; Hackstein, J.H.P.; Woltering, E.J.; Harren, F.J.M. Optical parametric oscillator-based photoacoustic detection of CO2 at 4.23 μm allows real-time monitoring of the respiration of small insects. Appl. Phys. B: Lasers Opt. 2006, 82, 665-669.
    • (2006) Appl. Phys. B: Lasers Opt , vol.82 , pp. 665-669
    • van Herpen, M.M.J.W.1    Ngai, A.K.Y.2    Bisson, S.E.3    Hackstein, J.H.P.4    Woltering, E.J.5    Harren, F.J.M.6
  • 86
  • 87
    • 9144242529 scopus 로고    scopus 로고
    • Pulsed quantum-cascade laser-based sensor for trace-gas detection of carbonyl sulfide
    • Wysocki, G.; McCurdy, M.; So, S.; Weidmann, D.; Roller, C.; Curl, R.F.; Tittel, F.K. Pulsed quantum-cascade laser-based sensor for trace-gas detection of carbonyl sulfide. Appl. Opt. 2004, 43, 6040-6046.
    • (2004) Appl. Opt , vol.43 , pp. 6040-6046
    • Wysocki, G.1    McCurdy, M.2    So, S.3    Weidmann, D.4    Roller, C.5    Curl, R.F.6    Tittel, F.K.7
  • 88
    • 34547895821 scopus 로고    scopus 로고
    • Performance of an exhaled nitric oxide and carbon dioxide sensor using quantum cascade laser-based integrated cavity output spectroscopy
    • 034034:1-034034:9
    • McCurdy, M.R.; Bakhirkin, Y.; Wysocki, G.; Tittel, F.K. Performance of an exhaled nitric oxide and carbon dioxide sensor using quantum cascade laser-based integrated cavity output spectroscopy. J. Biomed. Opt. 2007, 12, 034034:1-034034:9.
    • (2007) J. Biomed. Opt. , vol.12
    • McCurdy, M.R.1    Bakhirkin, Y.2    Wysocki, G.3    Tittel, F.K.4
  • 89
    • 0026245006 scopus 로고
    • Tunable diode laser spectroscopy for isotope analysis-detection of isotopic carbon monoxide in exhaled breath
    • Lee, P.S.; Majkowski, R.F.; Perry, T.A. Tunable diode laser spectroscopy for isotope analysis-detection of isotopic carbon monoxide in exhaled breath. IEEE Trans. Biomed. Eng. 1991, 38, 966-972.
    • (1991) IEEE Trans. Biomed. Eng , vol.38 , pp. 966-972
    • Lee, P.S.1    Majkowski, R.F.2    Perry, T.A.3
  • 90
    • 0242269963 scopus 로고    scopus 로고
    • Carbonyl sulfide detection with a thermoelectrically cooled midinfrared quantum cascade laser
    • Roller, C.; Kosterev, A.A.; Tittel, F.K.; Uehara, K.; Gmachl, C.; Sivco, D.L. Carbonyl sulfide detection with a thermoelectrically cooled midinfrared quantum cascade laser. Opt. Lett. 2003, 28, 2052-2054.
    • (2003) Opt. Lett , vol.28 , pp. 2052-2054
    • Roller, C.1    Kosterev, A.A.2    Tittel, F.K.3    Uehara, K.4    Gmachl, C.5    Sivco, D.L.6
  • 91
    • 66349118037 scopus 로고    scopus 로고
    • Laser based human breath analysis: D/H isotope ratio increases following heavy water intake
    • Bartlome, R.; Sigrist, M.W. laser based human breath analysis: D/H isotope ratio increases following heavy water intake. Opt. Lett. 2009, 34, 866-868.
    • (2009) Opt. Lett. , vol.34 , pp. 866-868
    • Bartlome, R.1    Sigrist, M.W.2
  • 92
    • 61449263007 scopus 로고    scopus 로고
    • Off-axis integrated cavity output spectroscopy with a mid-infrared interband cascade laser for real-time breath ethane measurements
    • Parameswaran, K.R.; Rosen, D.I.; Allen, M.G.; Ganz, A.M.; Risby, T.H. Off-axis integrated cavity output spectroscopy with a mid-infrared interband cascade laser for real-time breath ethane measurements. Appl. Opt. 2009, 48, B73-B79.
    • (2009) Appl. Opt , vol.48
    • Parameswaran, K.R.1    Rosen, D.I.2    Allen, M.G.3    Ganz, A.M.4    Risby, T.H.5
  • 98
    • 33749333402 scopus 로고    scopus 로고
    • Detection of formaldehyde using off-axis integrated cavity output spectroscopy with an interband cascade laser
    • Miller, J.H.; Bakhirkin, Y.A.; Ajtai, T.; Tittel, F.K.; Hill, C.J.; Yang, R.Q. Detection of formaldehyde using off-axis integrated cavity output spectroscopy with an interband cascade laser. Appl. Phys. B: Laser Opt. 2006, 85, 391-396.
    • (2006) Appl. Phys. B: Laser Opt , vol.85 , pp. 391-396
    • Miller, J.H.1    Bakhirkin, Y.A.2    Ajtai, T.3    Tittel, F.K.4    Hill, C.J.5    Yang, R.Q.6
  • 99
    • 0034741095 scopus 로고    scopus 로고
    • Ambient formaldehyde detection with a laser spectrometer based on difference-frequency generation in PPLN
    • Rehle, D.; Leleux, D.; Erdelyi, M.; Tittel, F.; Fraser, M.; Friedfeld, S. Ambient formaldehyde detection with a laser spectrometer based on difference-frequency generation in PPLN. Appl. Phys. B: Laser Opt. 2001, 72, 947-952.
    • (2001) Appl. Phys. B: Laser Opt , vol.72 , pp. 947-952
    • Rehle, D.1    Leleux, D.2    Erdelyi, M.3    Tittel, F.4    Fraser, M.5    Friedfeld, S.6
  • 100
    • 0036758018 scopus 로고    scopus 로고
    • Rapid formaldehyde monitoring in ambient air by means of mid-infrared cavity leak-out spectroscopy
    • Dahnke, H.; von Basum, G.; Kleinermanns, K.; Hering, P.; Murtz, M. Rapid formaldehyde monitoring in ambient air by means of mid-infrared cavity leak-out spectroscopy. Appl. Phys. B: Lasers Opt. 2002, 75, 311-316.
    • (2002) Appl. Phys. B: Lasers Opt , vol.75 , pp. 311-316
    • Dahnke, H.1    von Basum, G.2    Kleinermanns, K.3    Hering, P.4    Murtz, M.5
  • 101
    • 33749011449 scopus 로고    scopus 로고
    • Photoacoustic spectroscopy of formaldehyde with tunable laser radiation at the parts per billion level
    • Angelmahr, M.; Miklos, A.; Hess, P. Photoacoustic spectroscopy of formaldehyde with tunable laser radiation at the parts per billion level. Appl. Phys. B: Lasers Opt. 2006, 85, 285-288.
    • (2006) Appl. Phys. B: Lasers Opt , vol.85 , pp. 285-288
    • Angelmahr, M.1    Miklos, A.2    Hess, P.3
  • 103
    • 0036708815 scopus 로고    scopus 로고
    • Development of a tunable mid-IR difference frequency laser source for highly sensitive airborne trace gas detection
    • Richter, D.; Fried, A.; Wert, B.P.; Walega, J.G.; Tittel, F.K. Development of a tunable mid-IR difference frequency laser source for highly sensitive airborne trace gas detection. Appl. Phys. B: Lasers Opt. 2002, 75, 281-288.
    • (2002) Appl. Phys. B: Lasers Opt , vol.75 , pp. 281-288
    • Richter, D.1    Fried, A.2    Wert, B.P.3    Walega, J.G.4    Tittel, F.K.5
  • 105
    • 34447504028 scopus 로고    scopus 로고
    • Spectroscopic investigation of methylated amines by a cavity-ringdown-based spectrometer
    • Marinov, D.; Rey, J.M.; Muller, M.G.; Sigrist, M.W. Spectroscopic investigation of methylated amines by a cavity-ringdown-based spectrometer. Appl. Opt. 2007, 46, 3981-3986.
    • (2007) Appl. Opt , vol.46 , pp. 3981-3986
    • Marinov, D.1    Rey, J.M.2    Muller, M.G.3    Sigrist, M.W.4
  • 106
    • 33749018557 scopus 로고    scopus 로고
    • Determination of exhaled nitric oxide distributions in a diverse sample population using tunable diode laser absorption spectroscopy
    • Namjou, K.; Roller, C.B.; Reich, T.E.; Jeffers, J.D.; McMillen, G.L.; McCann, P.J.; Camp, M.A. Determination of exhaled nitric oxide distributions in a diverse sample population using tunable diode laser absorption spectroscopy. Appl. Phys. B: Lasers Opt. 2006, 85, 427-435.
    • (2006) Appl. Phys. B: Lasers Opt , vol.85 , pp. 427-435
    • Namjou, K.1    Roller, C.B.2    Reich, T.E.3    Jeffers, J.D.4    McMillen, G.L.5    McCann, P.J.6    Camp, M.A.7
  • 109
    • 0036771780 scopus 로고    scopus 로고
    • Nitric oxide breath testing by tunable-diode laser absorption spectroscopy: Application in monitoring respiratory inflammation
    • Roller, C.; Namjou, K.; Jeffers, J.D.; Camp, M.; Mock, A.; McCann, P.J.; Grego, J. Nitric oxide breath testing by tunable-diode laser absorption spectroscopy: application in monitoring respiratory inflammation. Appl. Opt. 2002, 41, 6018-6029.
    • (2002) Appl. Opt. , vol.41 , pp. 6018-6029
    • Roller, C.1    Namjou, K.2    Jeffers, J.D.3    Camp, M.4    Mock, A.5    McCann, P.J.6    Grego, J.7
  • 111
    • 64249148380 scopus 로고    scopus 로고
    • Infrared laser-spectroscopic analysis of 14NO and 15NO in human breath
    • Heinrich, K.; Fritsch, T.; Hering, P.; Murtz, M. Infrared laser-spectroscopic analysis of 14NO and 15NO in human breath. Appl. Phys. B: Lasers Opt. 2009, 95, 281-286.
    • (2009) Appl. Phys. B: Lasers Opt , vol.95 , pp. 281-286
    • Heinrich, K.1    Fritsch, T.2    Hering, P.3    Murtz, M.4
  • 112
    • 0037261382 scopus 로고    scopus 로고
    • Quantification of acetaldehyde released by lung cancer cells in vitro using selected-ion flow-tube mass spectrometry
    • Smith, D.; Wang, T.; Sule-Suso, J.; Spanel, P.; Haj, A.E. Quantification of acetaldehyde released by lung cancer cells in vitro using selected-ion flow-tube mass spectrometry. Rapid Commun. Mass Spectrom. 2003, 17, 845-850.
    • (2003) Rapid Commun. Mass Spectrom , vol.17 , pp. 845-850
    • Smith, D.1    Wang, T.2    Sule-Suso, J.3    Spanel, P.4    Haj, A.E.5
  • 113
    • 29144508524 scopus 로고    scopus 로고
    • Longitudinal study of ethanol and acetaldehyde in the exhaled breath of healthy volunteers using selected-ion flow-tube mass spectrometry. Rapid Commun
    • Turner, C.; Spanel, P.; Smith, D. A longitudinal study of ethanol and acetaldehyde in the exhaled breath of healthy volunteers using selected-ion flow-tube mass spectrometry. Rapid Commun. Mass Spectrom. 2006, 20, 61-68.
    • (2006) Mass Spectrom , vol.20 , pp. 61-68
    • Turner, C.1    Spanel, P.2    Smith, D.A.3
  • 115
    • 70350405860 scopus 로고    scopus 로고
    • Online laser-based detection of trace gas emission by avocado under changing atmospheric conditions. Acta Hortic
    • Persijn, S.T.; Parker, D.H.; Harren, F.J.M.; Veltman, R.H. Online laser-based detection of trace gas emission by avocado under changing atmospheric conditions. Acta Hortic. (ISHS) 2001, 553, 499-504.
    • (2001) , vol.553 , pp. 499-504
    • Persijn, S.T.1    Parker, D.H.2    Harren, F.J.M.3    Veltman, R.H.4
  • 116
    • 4544255985 scopus 로고    scopus 로고
    • Determination of acetone in human breath by gas chromatography-mass spectrometry and solid-phase microextraction with on-fiber derivatization
    • Deng, C.; Zhang, J.; Yu, X.; Zhang, W.; Zhang, X. Determination of acetone in human breath by gas chromatography-mass spectrometry and solid-phase microextraction with on-fiber derivatization. J. Chromatogr. B 2004, 810, 269-275.
    • (2004) J. Chromatogr. B , vol.810 , pp. 269-275
    • Deng, C.1    Zhang, J.2    Yu, X.3    Zhang, W.4    Zhang, X.5
  • 118
    • 36849055638 scopus 로고    scopus 로고
    • Monitoring of oxidative and metabolic stress during cardiac surgery by means of breath biomarkers: An observational study
    • Pabst, F.; Miekisch, W.; Fuchs, P.; Kischkel, S.; Schubert, J.K. Monitoring of oxidative and metabolic stress during cardiac surgery by means of breath biomarkers: an observational study. J. Cardiothorac. Surg. 2007, 2, 37.
    • (2007) J. Cardiothorac. Surg. , vol.2 , pp. 37
    • Pabst, F.1    Miekisch, W.2    Fuchs, P.3    Kischkel, S.4    Schubert, J.K.5
  • 121
    • 0036846881 scopus 로고    scopus 로고
    • Breath ammonia measurement in Helicobacter pylori infection
    • Kearney, D.J.; Hubbard, T.; Putnam, D. Breath ammonia measurement in Helicobacter pylori infection. Dig. Dis. Sci. 2002, 47, 2523-2530.
    • (2002) Dig. Dis. Sci , vol.47 , pp. 2523-2530
    • Kearney, D.J.1    Hubbard, T.2    Putnam, D.3
  • 122
    • 41149117049 scopus 로고    scopus 로고
    • Selected ion flow tube mass spectrometry study of ammonia in mouth- and nose-exhaled breath and in the oral cavity
    • Smith, D.; Wang, T.; Pysanenko, A.; Spanel, P. A selected ion flow tube mass spectrometry study of ammonia in mouth- and nose-exhaled breath and in the oral cavity. Rapid Commun. Mass Spectrom. 2008, 22, 783-789.
    • (2008) Rapid Commun. Mass Spectrom , vol.22 , pp. 783-789
    • Smith, D.1    Wang, T.2    Pysanenko, A.3    Spanel, P.A.4
  • 123
    • 0023262262 scopus 로고
    • Campylobacter pylori detected noninvasively by the 13C-urea breath test
    • Graham, D.Y.; Klein, P.D.; Evans, D.J., Jr. Campylobacter pylori detected noninvasively by the 13C-urea breath test. Lancet 1987, 11, 1174-1177.
    • (1987) Lancet , vol.11 , pp. 1174-1177
    • Graham, D.Y.1    Klein, P.D.2    Evans Jr, D.J.3
  • 124
    • 0025611518 scopus 로고
    • A methodological analysis of the 13C-urea breath test for detection of Helicobacter pylori infections: High sensitivity and specificity within 30 min using 75 mg of 13C-urea
    • Eggers, R.H.; Kulp, A.; Tegeler, R.; Ludtke, F.E.; Lepsien, G.; Meyer, B.; Bauer, F.E. A methodological analysis of the 13C-urea breath test for detection of Helicobacter pylori infections: high sensitivity and specificity within 30 min using 75 mg of 13C-urea. Eur. J. Gastroenterol. Hepatol. 1990, 2, 437-444.
    • (1990) Eur. J. Gastroenterol. Hepatol. , vol.2 , pp. 437-444
    • Eggers, R.H.1    Kulp, A.2    Tegeler, R.3    Ludtke, F.E.4    Lepsien, G.5    Meyer, B.6    Bauer, F.E.7
  • 127
    • 0017729722 scopus 로고
    • Application of a stable isotope 13C-labeled glycocholate breath test to diagnosis of bacterial overgrowth and ileal dysfunction
    • Solomons, N.W.; Schoeler, D.A.; Wagonfeld, J.B.; Ott, D.G.; Rosenberg, I.H.; Klein, P.D. Application of a stable isotope 13C-labeled glycocholate breath test to diagnosis of bacterial overgrowth and ileal dysfunction. J. Lab. Clin. Med. 1977, 90, 431-439.
    • (1977) J. Lab. Clin. Med , vol.90 , pp. 431-439
    • Solomons, N.W.1    Schoeler, D.A.2    Wagonfeld, J.B.3    Ott, D.G.4    Rosenberg, I.H.5    Klein, P.D.6
  • 128
    • 84975597468 scopus 로고
    • Stable isotope analysis using tunable diode laser spectroscopy
    • Becker, J.F.; Sauke, T.B.; Loewenstein, M. Stable isotope analysis using tunable diode laser spectroscopy. Appl. Opt. 1992, 31, 1921-1927.
    • (1992) Appl. Opt , vol.31 , pp. 1921-1927
    • Becker, J.F.1    Sauke, T.B.2    Loewenstein, M.3
  • 129
    • 0036757449 scopus 로고    scopus 로고
    • 13CO2 /13CO2 isotopic ratio measurements using a difference frequency-based sensor operating at 4.35 μm
    • Erdélyi, M.; Richter, D.; Tittel, F.K. 13CO2 /13CO2 isotopic ratio measurements using a difference frequency-based sensor operating at 4.35 μm. Appl. Phys. B: Lasers Opt. 2002, 75, 289-295.
    • (2002) Appl. Phys. B: Lasers Opt , vol.75 , pp. 289-295
    • Erdélyi, M.1    Richter, D.2    Tittel, F.K.3
  • 130
    • 11244293661 scopus 로고    scopus 로고
    • First field determination of the 13C/12C isotope ratio in volcanic CO2 by diode-laser spectrometry
    • Castrillo, A.; Casa, G.; van Burgel, M.; Tedesco, D.; Gianfrani, L. First field determination of the 13C/12C isotope ratio in volcanic CO2 by diode-laser spectrometry. Opt. Express. 2004, 12, 6515-6523.
    • (2004) Opt. Express , vol.12 , pp. 6515-6523
    • Castrillo, A.1    Casa, G.2    van Burgel, M.3    Tedesco, D.4    Gianfrani, L.5
  • 131
    • 27244437586 scopus 로고    scopus 로고
    • Diode laser absorption spectrometry for 13CO2 /12CO2 isotope ratio analysis: Investigation on precision and accuracy levels
    • Castrillo, A.; Casa, G.; Kerstel, E.; Gianfrani, L. Diode laser absorption spectrometry for 13CO2 /12CO2 isotope ratio analysis: Investigation on precision and accuracy levels. Appl. Phys. B: Lasers Opt. 2005, 81, 863-869.
    • (2005) Appl. Phys. B: Lasers Opt. , vol.81 , pp. 863-869
    • Castrillo, A.1    Casa, G.2    Kerstel, E.3    Gianfrani, L.4
  • 133
    • 15844368334 scopus 로고    scopus 로고
    • NIR diode laser spectroscopy for isotope selective sensing of soil-respired carbon dioxide
    • Horner, G.; Lau, S.; Lohmannsroben, H-G. NIR diode laser spectroscopy for isotope selective sensing of soil-respired carbon dioxide. SPIE Proc. Ser. 2004, 5544, 47-54.
    • (2004) SPIE Proc. Ser , vol.5544 , pp. 47-54
    • Horner, G.1    Lau, S.2    Lohmannsroben, H.-G.3
  • 134
    • 39149094912 scopus 로고    scopus 로고
    • New method for isotopic ratio measurements of atmospheric carbon dioxide using a 4.3 μm pulsed quantum cascade laser
    • Nelson, D.D.; McManus, J.B.; Herndon, S.C.; Zahniser, M.S.; Tuzson, B.; Emmenegger, L. New method for isotopic ratio measurements of atmospheric carbon dioxide using a 4.3 μm pulsed quantum cascade laser. Appl. Phys. B: Lasers Opt. 2008, 90, 301-309.
    • (2008) Appl. Phys. B: Lasers Opt , vol.90 , pp. 301-309
    • Nelson, D.D.1    McManus, J.B.2    Herndon, S.C.3    Zahniser, M.S.4    Tuzson, B.5    Emmenegger, L.6
  • 137
    • 0030851657 scopus 로고    scopus 로고
    • Carbon monoxide and bilirubin production in neonates
    • Stevenson, D.K.; Vreman, H.J. Carbon monoxide and bilirubin production in neonates. Pediatr. Rev. 1997, 100, 252-259.
    • (1997) Pediatr. Rev , vol.100 , pp. 252-259
    • Stevenson, D.K.1    Vreman, H.J.2
  • 138
    • 0026033907 scopus 로고
    • Induction of heme oxygenase: A general response to oxidant stress in cultured mammalian cells
    • Applegate, L.A.; Luscher, P.; Tyrrell, R.M. Induction of heme oxygenase: a general response to oxidant stress in cultured mammalian cells. Cancer Res. 1991, 51, 974-978.
    • (1991) Cancer Res , vol.51 , pp. 974-978
    • Applegate, L.A.1    Luscher, P.2    Tyrrell, R.M.3
  • 141
    • 33645732076 scopus 로고    scopus 로고
    • Sub-part-per-billion monitoring of nitric oxide by use of wavelength modulation spectroscopy in combination with a thermoelectrically cooled, continuous-wave quantum cascade laser
    • Moeskops, B.W.; Cristescu, S.M.; Harren, F.J. Sub-part-per-billion monitoring of nitric oxide by use of wavelength modulation spectroscopy in combination with a thermoelectrically cooled, continuous-wave quantum cascade laser. Opt. Lett. 2006, 31, 823-825.
    • (2006) Opt. Lett , vol.31 , pp. 823-825
    • Moeskops, B.W.1    Cristescu, S.M.2    Harren, F.J.3
  • 142
    • 0036227810 scopus 로고    scopus 로고
    • Breath biomarkers for detection of human liver diseases: Preliminary study
    • Sehnert, S.S.; Jiang, L.; Burdick, J.F.; Risby, T.H. Breath biomarkers for detection of human liver diseases: preliminary study. Biomarkers 2002, 7, 174-187.
    • (2002) Biomarkers , vol.7 , pp. 174-187
    • Sehnert, S.S.1    Jiang, L.2    Burdick, J.F.3    Risby, T.H.4
  • 144
    • 84975602900 scopus 로고
    • Versatile integrated tunable diode laser system for high precsion: Application for ambient measurement of OCS
    • Fried, A.; Drummound, J.R.; Henry, B.; Fox, J. Versatile integrated tunable diode laser system for high precsion: application for ambient measurement of OCS. Appl. Opt. 1991, 30, 1916-1932.
    • (1991) Appl. Opt. , vol.30 , pp. 1916-1932
    • Fried, A.1    Drummound, J.R.2    Henry, B.3    Fox, J.4
  • 145
    • 0036757981 scopus 로고    scopus 로고
    • Trace gas sensing in the 3.3 μm region using a diode based difference frequency laser photoaocustic system
    • Fischer, C.; Sigrist, M.W. Trace gas sensing in the 3.3 μm region using a diode based difference frequency laser photoaocustic system. Appl. Phys. B: Lasers Opt. 2002, 75, 305-310.
    • (2002) Appl. Phys. B: Lasers Opt , vol.75 , pp. 305-310
    • Fischer, C.1    Sigrist, M.W.2
  • 148
    • 0032607529 scopus 로고    scopus 로고
    • On-line laser photoacoustic detection of ethene in exhaled air as biomarker of ultraviolet radiation damage of the human skin. Appl. Phys. Lett
    • Harren, F.J.M.; Berkelmans, R.; Kuiper, K.; te Lintel Hekkert, S.; Scheepers, P.; Dekhuijzen, R.; Hollander, P.; Parker, D.H. On-line laser photoacoustic detection of ethene in exhaled air as biomarker of ultraviolet radiation damage of the human skin. Appl. Phys. Lett. 1999, 74, 1761-1763.
    • (1999) , vol.74 , pp. 1761-1763
    • Harren, F.J.M.1    Berkelmans, R.2    Kuiper, K.3    te Lintel Hekkert, S.4    Scheepers, P.5    Dekhuijzen, R.6    Hollander, P.7    Parker, D.H.8
  • 152
    • 0035181340 scopus 로고    scopus 로고
    • Rapid measurement of deuterium content of breath following oral ingestion to determine body water
    • Davies, S.; Spanel, P.; Smith, D. Rapid measurement of deuterium content of breath following oral ingestion to determine body water. Physiol. Meas. 2001, 22, 651-659.
    • (2001) Physiol. Meas , vol.22 , pp. 651-659
    • Davies, S.1    Spanel, P.2    Smith, D.3
  • 153
    • 0027082769 scopus 로고
    • Use of breath hydrogen and methane as markers of colonic fermentation in epidemiologic studies: Circadian patterns of excretion
    • Le Marchand, L.; Wilkens, L.R.; Harwood, P.; Cooney, R.V. Use of breath hydrogen and methane as markers of colonic fermentation in epidemiologic studies: circadian patterns of excretion. Environ. Health Perspect. 1992, 98, 199-202.
    • (1992) Environ. Health Perspect. , vol.98 , pp. 199-202
    • Le Marchand, L.1    Wilkens, L.R.2    Harwood, P.3    Cooney, R.V.4
  • 154
    • 32044441827 scopus 로고    scopus 로고
    • Simultaneous detection of ammonia, methane and ethylene at 1.63 μm with diode laser photoacoustic spectroscopy
    • Scotoni, M.; Rossi, A.; Bassi, D.; Buffa, R.; Iannotta, S.; Boschetti, A. Simultaneous detection of ammonia, methane and ethylene at 1.63 μm with diode laser photoacoustic spectroscopy. Appl. Phys. B: Lasers Opt. 2006, 82, 495-500.
    • (2006) Appl. Phys. B: Lasers Opt , vol.82 , pp. 495-500
    • Scotoni, M.1    Rossi, A.2    Bassi, D.3    Buffa, R.4    Iannotta, S.5    Boschetti, A.6
  • 155
    • 33644879420 scopus 로고    scopus 로고
    • New improvements in methane detection using a Helmholtz resonant photoacoustic laser sensor: A comparison between near-IR diode lasers and mid-IR quantum cascade lasers
    • Grossel, A.; Zeninari, V.; Joly, L.; Parvitte, B.; Courtois, D.; Durry, G. New improvements in methane detection using a Helmholtz resonant photoacoustic laser sensor: A comparison between near-IR diode lasers and mid-IR quantum cascade lasers. Spectrochim. Acta, Part A 2006, 63, 1021-1028.
    • (2006) Spectrochim. Acta, Part A , vol.63 , pp. 1021-1028
    • Grossel, A.1    Zeninari, V.2    Joly, L.3    Parvitte, B.4    Courtois, D.5    Durry, G.6
  • 156
    • 0036757489 scopus 로고    scopus 로고
    • Portable difference-frequency laser-based cavity leak-out spectrometer for trace-gas analysis
    • Stry, S.; Hering, P.; Murtz, M. Portable difference-frequency laser-based cavity leak-out spectrometer for trace-gas analysis. Appl. Phys. B: Lasers Opt. 2002, 75, 297-303.
    • (2002) Appl. Phys. B: Lasers Opt , vol.75 , pp. 297-303
    • Stry, S.1    Hering, P.2    Murtz, M.3
  • 159
    • 56349096481 scopus 로고    scopus 로고
    • Trace gas measurements using optically resonant cavities and quantum cascade lasers operating at room temperature
    • 093115/1-15
    • Welzel, S.; Lombardi, G.; Davies, P.B.; Engeln, R.; Schram, D.C.; Ropcke, J. Trace gas measurements using optically resonant cavities and quantum cascade lasers operating at room temperature. J. Appl. Phys. 2008, 104, 093115/1-15.
    • (2008) J. Appl. Phys. , vol.104
    • Welzel, S.1    Lombardi, G.2    Davies, P.B.3    Engeln, R.4    Schram, D.C.5    Ropcke, J.6
  • 160
    • 47749102875 scopus 로고    scopus 로고
    • Novel multiple species ringdown spectrometer for in situ measurements of methane, carbon dioxide, and carbon isotope
    • Wang, C.; Srivastava, N.; Jones, B.A.; Reese, R.B. A novel multiple species ringdown spectrometer for in situ measurements of methane, carbon dioxide, and carbon isotope. Appl. Phys. B: Lasers Opt. 2008, 92, 259-270.
    • (2008) Appl. Phys. B: Lasers Opt , vol.92 , pp. 259-270
    • Wang, C.1    Srivastava, N.2    Jones, B.A.3    Reese, R.B.A.4
  • 161
    • 0030483222 scopus 로고    scopus 로고
    • Nitric oxide in exhaled air is a new marker of airway inflammation
    • Kharitonov, S.A.; Barnes, P.J. Nitric oxide in exhaled air is a new marker of airway inflammation. Monaldi. Arch. Chest Dis. 1996, 51, 533-537.
    • (1996) Monaldi. Arch. Chest Dis , vol.51 , pp. 533-537
    • Kharitonov, S.A.1    Barnes, P.J.2
  • 162
    • 6344258223 scopus 로고    scopus 로고
    • Nitric oxide as a noninvasive biomarker of lipopolysaccharide-induced airway inflammation: Possible role in lung neutrophilia
    • McCluskie, K.; Birrell, M.A.; Wong, S.; Belvisi, M.G. Nitric oxide as a noninvasive biomarker of lipopolysaccharide-induced airway inflammation: possible role in lung neutrophilia. J. Pharmacol. Exp. Ther. 2004, 311, 625-633.
    • (2004) J. Pharmacol. Exp. Ther. , vol.311 , pp. 625-633
    • McCluskie, K.1    Birrell, M.A.2    Wong, S.3    Belvisi, M.G.4
  • 163
    • 33845372026 scopus 로고    scopus 로고
    • Utility of exhaled nitric oxide as a noninvasive biomarker of lung inflammation in a disease model
    • Birrell, M.A.; McCluskie, K.; Hardaker, E.; Knowles, R.; Belvisi, M.G. Utility of exhaled nitric oxide as a noninvasive biomarker of lung inflammation in a disease model. Eur. Respir. J. 2006, 28, 1236-1244.
    • (2006) Eur. Respir. J , vol.28 , pp. 1236-1244
    • Birrell, M.A.1    McCluskie, K.2    Hardaker, E.3    Knowles, R.4    Belvisi, M.G.5
  • 164
    • 84876614810 scopus 로고    scopus 로고
    • Available online, (accessed October 16, 2009)
    • Breathmeter; Available online: http://www.ekipstech.com/pages/homepage/breathmeter/webpage category.xml (accessed October 16, 2009).
    • Breathmeter
  • 165
    • 72349090502 scopus 로고    scopus 로고
    • Available online, (accessed October 16, 2009)
    • Gas Sensors; Available online: http://www.pranalytica.com/technology-gas-sensors.html (accessed October 16, 2009).
    • Gas Sensors
  • 166
    • 34250333048 scopus 로고    scopus 로고
    • QEPAS based detection of broadband absorbing molecules using a widely tunable, cw quantum cascade laser at 8.4 μm
    • Lewicki, R.; Wysocki, G.; Kosterev, A.A.; Tittel, F.K. QEPAS based detection of broadband absorbing molecules using a widely tunable, cw quantum cascade laser at 8.4 μm. Opt. Express. 2007, 15, 7357-7366.
    • (2007) Opt. Express , vol.15 , pp. 7357-7366
    • Lewicki, R.1    Wysocki, G.2    Kosterev, A.A.3    Tittel, F.K.4
  • 167
    • 17644363081 scopus 로고    scopus 로고
    • ATS/ERS recommendations for standardized procedures for the online and offline measurement of exhaled lower respiratory nitric oxide and nasal nitric oxide
    • ATS/ERS recommendations for standardized procedures for the online and offline measurement of exhaled lower respiratory nitric oxide and nasal nitric oxide, 2005. Am. J. Respir. Crit. Care Med. 2005, 171, 912-930
    • (2005) Am. J. Respir. Crit. Care Med , vol.171 , pp. 912-930


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.