메뉴 건너뛰기




Volumn 426, Issue , 2013, Pages 79-84

Interference from heterophilic antibodies in troponin testing. Case report and systematic review of the literature

Author keywords

Heterophilic antibodies; Human anti mouse antibodies; Interference; Troponin

Indexed keywords

ALANINE AMINOTRANSFERASE; BILIRUBIN; BIOLOGICAL MARKER; CREATINE KINASE MB; CREATININE; HETEROPHILE ANTIBODY; MACROGOL; PROTEIN A; TROPONIN I; TROPONIN T;

EID: 84884789108     PISSN: 00098981     EISSN: 18733492     Source Type: Journal    
DOI: 10.1016/j.cca.2013.09.004     Document Type: Review
Times cited : (75)

References (39)
  • 1
    • 84856998946 scopus 로고    scopus 로고
    • Biomedical research platforms and their influence on article submissions and journal rankings: an update
    • Lippi G., Favalor E.J., Simundic A.M. Biomedical research platforms and their influence on article submissions and journal rankings: an update. Biochem Med (Zagreb) 2012, 22:7-14.
    • (2012) Biochem Med (Zagreb) , vol.22 , pp. 7-14
    • Lippi, G.1    Favalor, E.J.2    Simundic, A.M.3
  • 3
    • 84882514040 scopus 로고    scopus 로고
    • False positive cardiac troponin elevation due to heterophile antibodies: more common than we recognise?
    • Zaidi A., Cowell R. False positive cardiac troponin elevation due to heterophile antibodies: more common than we recognise?. BMJ Case Rep Jul 2010, 15:2010. 10.1136/bcr.11.2009.2477.
    • (2010) BMJ Case Rep , vol.15 , pp. 2010
    • Zaidi, A.1    Cowell, R.2
  • 4
    • 0036581603 scopus 로고    scopus 로고
    • False-positive troponin I in a young healthy woman with chest pain
    • Ringdahl E.N., Stevermer J.J. False-positive troponin I in a young healthy woman with chest pain. J Am Board Fam Pract 2002, 15:242-245.
    • (2002) J Am Board Fam Pract , vol.15 , pp. 242-245
    • Ringdahl, E.N.1    Stevermer, J.J.2
  • 6
    • 0031710957 scopus 로고    scopus 로고
    • False increase of cardiac troponin I with heterophilic antibodies
    • Fitzmaurice T.F., Brown C., Rifai N., Wu A.H., Yeo K.T. False increase of cardiac troponin I with heterophilic antibodies. Clin Chem 1998, 44:2212-2214.
    • (1998) Clin Chem , vol.44 , pp. 2212-2214
    • Fitzmaurice, T.F.1    Brown, C.2    Rifai, N.3    Wu, A.H.4    Yeo, K.T.5
  • 7
    • 0033970391 scopus 로고    scopus 로고
    • Performance of the enhanced Abbott AxSYM cardiac troponin I reagent in patients with heterophilic antibodies
    • Yeo K.T., Storm C.A., Li Y., et al. Performance of the enhanced Abbott AxSYM cardiac troponin I reagent in patients with heterophilic antibodies. Clin Chim Acta 2000, 292:13-23.
    • (2000) Clin Chim Acta , vol.292 , pp. 13-23
    • Yeo, K.T.1    Storm, C.A.2    Li, Y.3
  • 8
    • 0034026889 scopus 로고    scopus 로고
    • Transient nature of interference effects from heterophile antibodies: examples of interference with cardiac marker measurements
    • Kazmierczak S.C., Catrou P.G., Briley K.P. Transient nature of interference effects from heterophile antibodies: examples of interference with cardiac marker measurements. Clin Chem Lab Med 2000, 38:33-39.
    • (2000) Clin Chem Lab Med , vol.38 , pp. 33-39
    • Kazmierczak, S.C.1    Catrou, P.G.2    Briley, K.P.3
  • 9
    • 18444363329 scopus 로고    scopus 로고
    • Multicenter evaluation of an automated assay for troponin I
    • Uettwiller-Geiger D., Wu A.H., Apple F.S., et al. Multicenter evaluation of an automated assay for troponin I. Clin Chem 2002, 48:869-876.
    • (2002) Clin Chem , vol.48 , pp. 869-876
    • Uettwiller-Geiger, D.1    Wu, A.H.2    Apple, F.S.3
  • 10
    • 0036139229 scopus 로고    scopus 로고
    • Heterophilic antibody interference with CARDIAC T Quantitative Rapid Assay
    • White G.H., Tideman P.A. Heterophilic antibody interference with CARDIAC T Quantitative Rapid Assay. Clin Chem 2002, 48:201-203.
    • (2002) Clin Chem , vol.48 , pp. 201-203
    • White, G.H.1    Tideman, P.A.2
  • 13
    • 18444375563 scopus 로고    scopus 로고
    • Performance of a revised cardiac troponin method that minimizes interferences from heterophilic antibodies
    • Kim W.J., Laterza O.F., Hock K.G., et al. Performance of a revised cardiac troponin method that minimizes interferences from heterophilic antibodies. Clin Chem 2002, 48:1028-1034.
    • (2002) Clin Chem , vol.48 , pp. 1028-1034
    • Kim, W.J.1    Laterza, O.F.2    Hock, K.G.3
  • 14
    • 0037094123 scopus 로고    scopus 로고
    • False-positive cardiac troponin I in a routine clinical population
    • Fleming S.M., O'Byrne L., Finn J., Grimes H., Daly K.M. False-positive cardiac troponin I in a routine clinical population. Am J Cardiol 2002, 89:1212-1215.
    • (2002) Am J Cardiol , vol.89 , pp. 1212-1215
    • Fleming, S.M.1    O'Byrne, L.2    Finn, J.3    Grimes, H.4    Daly, K.M.5
  • 15
    • 4043141400 scopus 로고    scopus 로고
    • A patient with an increased troponin level without evidence of ischaemic cardiac injury
    • Chan A.O., Chan J.P., Choi K.L., Shek C.C. A patient with an increased troponin level without evidence of ischaemic cardiac injury. Hong Kong Med J 2004, 10:277-279.
    • (2004) Hong Kong Med J , vol.10 , pp. 277-279
    • Chan, A.O.1    Chan, J.P.2    Choi, K.L.3    Shek, C.C.4
  • 16
    • 3242659235 scopus 로고    scopus 로고
    • Quality specifications for biochemical markers of myocardial injury
    • Zaninotto M., Mion M., Altinier S., Forni M., Plebani M. Quality specifications for biochemical markers of myocardial injury. Clin Chim Acta 2004, 346:65-72.
    • (2004) Clin Chim Acta , vol.346 , pp. 65-72
    • Zaninotto, M.1    Mion, M.2    Altinier, S.3    Forni, M.4    Plebani, M.5
  • 17
    • 18844451473 scopus 로고    scopus 로고
    • Heterophile antibodies produce spuriously elevated concentrations of cardiac Troponin I in patients with Legionella pneumophila
    • García-Mancebo M.L., Agulló-Ortuño M.T., Gimeno J.R., et al. Heterophile antibodies produce spuriously elevated concentrations of cardiac Troponin I in patients with Legionella pneumophila. Clin Biochem 2005, 38:584-587.
    • (2005) Clin Biochem , vol.38 , pp. 584-587
    • García-Mancebo, M.L.1    Agulló-Ortuño, M.T.2    Gimeno, J.R.3
  • 18
    • 33748932343 scopus 로고    scopus 로고
    • False positive cardiac troponin results in patients without acute myocardial infarction
    • Lum G., Solarz D.E., Farney L. False positive cardiac troponin results in patients without acute myocardial infarction. Lab Med 2006, 37:546-550.
    • (2006) Lab Med , vol.37 , pp. 546-550
    • Lum, G.1    Solarz, D.E.2    Farney, L.3
  • 19
    • 33847006249 scopus 로고    scopus 로고
    • Unnecessary coronary angiography due to false positive troponin I results in a 51-year-old man
    • Bionda C., Rousson R., Collin-Chavagnac D., Manchon M., Chikh K., Charrié A. Unnecessary coronary angiography due to false positive troponin I results in a 51-year-old man. Clin Chim Acta 2007, 378:225-226.
    • (2007) Clin Chim Acta , vol.378 , pp. 225-226
    • Bionda, C.1    Rousson, R.2    Collin-Chavagnac, D.3    Manchon, M.4    Chikh, K.5    Charrié, A.6
  • 20
    • 47649094165 scopus 로고    scopus 로고
    • Heterophilic antibody interference in an ultra-sensitive 3-site sandwich troponin I immunoassay
    • Zhu Y., Jenkins M.M., Brass D.A., et al. Heterophilic antibody interference in an ultra-sensitive 3-site sandwich troponin I immunoassay. Clin Chim Acta 2008, 395:181-182.
    • (2008) Clin Chim Acta , vol.395 , pp. 181-182
    • Zhu, Y.1    Jenkins, M.M.2    Brass, D.A.3
  • 21
    • 49549120208 scopus 로고    scopus 로고
    • False-positive cardiac troponin T due to assay interference with heterophilic antibodies
    • Shayanfar N., Bestmann L., Schulthess G., Hersberger M. False-positive cardiac troponin T due to assay interference with heterophilic antibodies. Swiss Med Wkly 2008, 138:470.
    • (2008) Swiss Med Wkly , vol.138 , pp. 470
    • Shayanfar, N.1    Bestmann, L.2    Schulthess, G.3    Hersberger, M.4
  • 22
    • 52949085535 scopus 로고    scopus 로고
    • Point-of-care testing: false elevation of cardiac troponin I assayed in the emergency department
    • Pernet P., Bénéteau-Burnat B., Hermand C., Vaubourdolle M. Point-of-care testing: false elevation of cardiac troponin I assayed in the emergency department. Am J Emerg Med 2008, 26(969):e1-e2.
    • (2008) Am J Emerg Med , vol.26 , Issue.969
    • Pernet, P.1    Bénéteau-Burnat, B.2    Hermand, C.3    Vaubourdolle, M.4
  • 23
    • 84884736438 scopus 로고    scopus 로고
    • Fluctuation of spuriously elevated troponin I: a case report
    • Ghali S., Lewis K., Kazan V., et al. Fluctuation of spuriously elevated troponin I: a case report. Case Reports in, Critical Care 2012, 585879.
    • (2012) Case Reports in, Critical Care , pp. 585879
    • Ghali, S.1    Lewis, K.2    Kazan, V.3
  • 24
    • 84860383231 scopus 로고    scopus 로고
    • High-sensitive cardiac troponin T outperforms novel diagnostic biomarkers in patients with acute chest pain
    • Eggers K.M., Venge P., Lindahl B. High-sensitive cardiac troponin T outperforms novel diagnostic biomarkers in patients with acute chest pain. Clin Chim Acta 2012, 413:1135-1140.
    • (2012) Clin Chim Acta , vol.413 , pp. 1135-1140
    • Eggers, K.M.1    Venge, P.2    Lindahl, B.3
  • 25
    • 84874243017 scopus 로고    scopus 로고
    • Diagnosis and management of ischemic heart disease
    • Lippi G., Franchini M., Cervellin G. Diagnosis and management of ischemic heart disease. Semin Thromb Hemost 2013, 39:202-213.
    • (2013) Semin Thromb Hemost , vol.39 , pp. 202-213
    • Lippi, G.1    Franchini, M.2    Cervellin, G.3
  • 26
    • 84886748212 scopus 로고    scopus 로고
    • Cardiospecific troponins in non-ischemic cardiological pathologies
    • Lippi G., Montagnana M., Guidi G.C. Cardiospecific troponins in non-ischemic cardiological pathologies. Emerg Care J 2006, 2:35-42.
    • (2006) Emerg Care J , vol.2 , pp. 35-42
    • Lippi, G.1    Montagnana, M.2    Guidi, G.C.3
  • 27
    • 84856553201 scopus 로고    scopus 로고
    • Influence of hemolysis on troponin testing: studies on Beckman Coulter UniCel Dxl 800 Accu-TnI and overview of the literature
    • Lippi G., Avanzini P., Dipalo M., Aloe R., Cervellin G. Influence of hemolysis on troponin testing: studies on Beckman Coulter UniCel Dxl 800 Accu-TnI and overview of the literature. Clin Chem Lab Med 2011, 49:2097-2100.
    • (2011) Clin Chem Lab Med , vol.49 , pp. 2097-2100
    • Lippi, G.1    Avanzini, P.2    Dipalo, M.3    Aloe, R.4    Cervellin, G.5
  • 28
    • 84858133049 scopus 로고    scopus 로고
    • Degradation of troponin I in serum or plasma: mechanisms, and analytical and clinical implications
    • Lippi G., Cervellin G. Degradation of troponin I in serum or plasma: mechanisms, and analytical and clinical implications. Semin Thromb Hemost 2012, 38:222-229.
    • (2012) Semin Thromb Hemost , vol.38 , pp. 222-229
    • Lippi, G.1    Cervellin, G.2
  • 29
    • 84881155977 scopus 로고    scopus 로고
    • Appropriate sample dilution for troponin I testing
    • [Epub ahead of print]
    • Lippi G., Avanzini P., Aloe R., Cervellin G. Appropriate sample dilution for troponin I testing. Am J Emerg Med Jun 24 2013, [Epub ahead of print]. 10.1016/j.ajem.2013.03.022.
    • (2013) Am J Emerg Med
    • Lippi, G.1    Avanzini, P.2    Aloe, R.3    Cervellin, G.4
  • 30
    • 84894550464 scopus 로고    scopus 로고
    • Analytically false or true positive elevations of high sensitivity cardiac troponin: a systematic approach
    • [Epub ahead of print]
    • Vafaie M., Biener M., Mueller M., et al. Analytically false or true positive elevations of high sensitivity cardiac troponin: a systematic approach. Heart Apr 25 2013, [Epub ahead of print].
    • (2013) Heart
    • Vafaie, M.1    Biener, M.2    Mueller, M.3
  • 31
    • 71649083738 scopus 로고    scopus 로고
    • Heterophile antibodies and troponin results: implications in rural setting
    • Narasimhan S., Clausen D. Heterophile antibodies and troponin results: implications in rural setting. N Z Med J 2009, 122:130-132.
    • (2009) N Z Med J , vol.122 , pp. 130-132
    • Narasimhan, S.1    Clausen, D.2
  • 32
    • 11144302516 scopus 로고    scopus 로고
    • The war on heterophilic antibody interference
    • Bjerner J., Børmer O.P., Nustad K. The war on heterophilic antibody interference. Clin Chem 2005, 51:9-11.
    • (2005) Clin Chem , vol.51 , pp. 9-11
    • Bjerner, J.1    Børmer, O.P.2    Nustad, K.3
  • 34
    • 74849108786 scopus 로고    scopus 로고
    • Prevalence of human anti-mouse antibodies (HAMAs) in routine examinations
    • Koshida S., Asanuma K., Kuribayashi K., et al. Prevalence of human anti-mouse antibodies (HAMAs) in routine examinations. Clin Chim Acta 2010, 411:391-394.
    • (2010) Clin Chim Acta , vol.411 , pp. 391-394
    • Koshida, S.1    Asanuma, K.2    Kuribayashi, K.3
  • 35
    • 84856522611 scopus 로고    scopus 로고
    • Heterophilic antibody interference in commercial immunoassays; a screening study using paired native and pre-blocked sera
    • Bolstad N., Warren D.J., Bjerner J., et al. Heterophilic antibody interference in commercial immunoassays; a screening study using paired native and pre-blocked sera. Clin Chem Lab Med 2011, 49:2001-2006.
    • (2011) Clin Chem Lab Med , vol.49 , pp. 2001-2006
    • Bolstad, N.1    Warren, D.J.2    Bjerner, J.3
  • 36
    • 68149156930 scopus 로고    scopus 로고
    • Prevalence of autoantibodies to cardiac troponin T in healthy blood donors
    • Adamczyk M., Brashear R.J., Mattingly P.G. Prevalence of autoantibodies to cardiac troponin T in healthy blood donors. Clin Chem 2009, 55:1592-1593.
    • (2009) Clin Chem , vol.55 , pp. 1592-1593
    • Adamczyk, M.1    Brashear, R.J.2    Mattingly, P.G.3
  • 37
    • 68149101247 scopus 로고    scopus 로고
    • Circulating cardiac troponin-I autoantibodies in human plasma and serum
    • Adamczyk M., Brashear R.J., Mattingly P.G. Circulating cardiac troponin-I autoantibodies in human plasma and serum. Ann N Y Acad Sci 2009, 1173:67-74.
    • (2009) Ann N Y Acad Sci , vol.1173 , pp. 67-74
    • Adamczyk, M.1    Brashear, R.J.2    Mattingly, P.G.3
  • 38
    • 84862568823 scopus 로고    scopus 로고
    • Highly sensitive troponin immunoassays: navigating between the scylla and charybdis
    • Lippi G., Montagnana M., Aloe R., Cervellin G. Highly sensitive troponin immunoassays: navigating between the scylla and charybdis. Adv Clin Chem 2012, 58:1-29.
    • (2012) Adv Clin Chem , vol.58 , pp. 1-29
    • Lippi, G.1    Montagnana, M.2    Aloe, R.3    Cervellin, G.4
  • 39
    • 69549120483 scopus 로고    scopus 로고
    • Highly sensitive cardiac troponin I assay leads to lowered specificity
    • Pfäfflin A. Highly sensitive cardiac troponin I assay leads to lowered specificity. Clin Chem 2009, 55:1749.
    • (2009) Clin Chem , vol.55 , pp. 1749
    • Pfäfflin, A.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.