1
-
-
0022918233
-
Incidence and specificity of interference in two-site immunoassays
-
Boscato LM, Stuart MC. Incidence and specificity of interference in two-site immunoassays. Clin Chem 1986; 32:1491-5.
-
(1986)
Clin Chem
, vol.32
, pp. 1491-1495
-
-
Boscato, L.M.1
Stuart, M.C.2
-
2
-
-
0031911110
-
Antibody interference in thyroid assays: A potential for clinical misinformation
-
Després N, Grant AM. Antibody interference in thyroid assays: a potential for clinical misinformation. [Review] Clin Chem 1998; 44:440-54.
-
(1998)
[Review] Clin Chem
, vol.44
, pp. 440-454
-
-
Després, N.1
Grant, A.M.2
-
3
-
-
0030765913
-
Heterophilic antibodies remain a problem for the immunoassay laboratory
-
Ward G, McKinnon L, Badrick T, Hickman PE. Heterophilic antibodies remain a problem for the immunoassay laboratory. Am J Clin Pathol 1997; 108:417-21.
-
(1997)
Am J Clin Pathol
, vol.108
, pp. 417-421
-
-
Ward, G.1
McKinnon, L.2
Badrick, T.3
Hickman, P.E.4
-
4
-
-
0029128635
-
Falsely elevated steroidal assay levels related to heterophile antibodies against various animal species
-
Check JH, Ubelacker L, Lauer CC. Falsely elevated steroidal assay levels related to heterophile antibodies against various animal species. Gynecol Obstet Invest 1995; 40:139-40.
-
(1995)
Gynecol Obstet Invest
, vol.40
, pp. 139-140
-
-
Check, J.H.1
Ubelacker, L.2
Lauer, C.C.3
-
5
-
-
0030892115
-
Heterophilic antibodies produce spuriously elevated concentrations of the MB isoenzyme of creatine kinase in a selected patient population
-
Sosolik RC, Hitchcock CL, Becker WJ. Heterophilic antibodies produce spuriously elevated concentrations of the MB isoenzyme of creatine kinase in a selected patient population. Am J Clin Pathol 1997; 107:506-10.
-
(1997)
Am J Clin Pathol
, vol.107
, pp. 506-510
-
-
Sosolik, R.C.1
Hitchcock, C.L.2
Becker, W.J.3
-
6
-
-
0026013686
-
Interference by iatrogenically induced anti-mouse IgG antibodies in a two-site immunometric assay for thyrotropin
-
Zweig MH, Csako G, Reynolds JC, Carrasquillo JA. Interference by iatrogenically induced anti-mouse IgG antibodies in a two-site immunometric assay for thyrotropin. Arch Pathol Lab Med 1991; 115:164-8.
-
(1991)
Arch Pathol Lab Med
, vol.115
, pp. 164-168
-
-
Zweig, M.H.1
Csako, G.2
Reynolds, J.C.3
Carrasquillo, J.A.4
-
7
-
-
0023739995
-
Artifactual CEA elevation due to human antimouse antibodies
-
Morton BA, O'Connor-Tressel M, Beatty BG, Shively JE, Beatty JD. Artifactual CEA elevation due to human antimouse antibodies. Arch Surg 1988; 123:1242-6.
-
(1988)
Arch Surg
, vol.123
, pp. 1242-1246
-
-
Morton, B.A.1
O'Connor-Tressel, M.2
Beatty, B.G.3
Shively, J.E.4
Beatty, J.D.5
-
8
-
-
0025981995
-
Human antimurine antibody interference in measurement of carcinoembryonic antigen assessed with a double-antibody enzyme immunoassay
-
Price T, Beatty BG, Beatty JD, McNally AJ. Human antimurine antibody interference in measurement of carcinoembryonic antigen assessed with a double-antibody enzyme immunoassay. Clin Chem 1991; 37:51-7.
-
(1991)
Clin Chem
, vol.37
, pp. 51-57
-
-
Price, T.1
Beatty, B.G.2
Beatty, J.D.3
McNally, A.J.4
-
9
-
-
84987460586
-
Immunotherapy of pancreatic cancer with monoclonal antibody BW 494
-
Schulz G, Büchler M, Muhrer KH, Klapdor R, Kübel R, Harthus HP, et al. Immunotherapy of pancreatic cancer with monoclonal antibody BW 494. Int J Cancer 1988; 41:Suppl 2:89-94.
-
(1988)
Int J Cancer
, vol.41
, Issue.SUPPL. 2
, pp. 89-94
-
-
Schulz, G.1
Büchler, M.2
Muhrer, K.H.3
Klapdor, R.4
Kübel, R.5
Harthus, H.P.6
-
10
-
-
0022909145
-
Artefactual increase in serum thyrotropin concentration caused by heterophilic antibodies with specificity for IgG of the family bovidea
-
Bartlett WA, Browning MCK, Jung RT. Artefactual increase in serum thyrotropin concentration caused by heterophilic antibodies with specificity for IgG of the family bovidea. Clin Chem 1986; 32:2214-9.
-
(1986)
Clin Chem
, vol.32
, pp. 2214-2219
-
-
Bartlett, W.A.1
Browning, M.C.K.2
Jung, R.T.3
-
11
-
-
0026389671
-
Sudden appearance and subsequent disappearance of interference in immunometric assays of thyrotropin neutralizable with purified mouse IgG
-
Wickus GG, Caplan RH, Mathews EA, Pehling GB. Sudden appearance and subsequent disappearance of interference in immunometric assays of thyrotropin neutralizable with purified mouse IgG. [Editorial]. Clin Chem 1991; 37:595-6.
-
(1991)
Clin Chem
, vol.37
, pp. 595-596
-
-
Wickus, G.G.1
Caplan, R.H.2
Mathews, E.A.3
Pehling, G.B.4
-
12
-
-
0026702425
-
2 conjugate and polyclonal mouse IgG
-
2 conjugate and polyclonal mouse IgG. Clin Chem 1992; 38:1737-42.
-
(1992)
Clin Chem
, vol.38
, pp. 1737-1742
-
-
Vaidya, H.C.1
Beatty, B.G.2
-
13
-
-
0031710957
-
False increases of cardiac troponin I with heterophilic antibodies
-
Fitzmaurice TF, Brown C, Rifai N, Wu AHB, Yeo KJ. False increases of cardiac troponin I with heterophilic antibodies. Clin Chem 1998; 44:2212-3.
-
(1998)
Clin Chem
, vol.44
, pp. 2212-2213
-
-
Fitzmaurice, T.F.1
Brown, C.2
Rifai, N.3
Wu, A.H.B.4
Yeo, K.J.5
-
14
-
-
0030610825
-
Value of HAMA determination in clinical practice- an overview
-
Hasholzner U, Stieber P, Meier W, Lamerz R. Value of HAMA determination in clinical practice- an overview. Anticancer Res 1997; 17:3055-8.
-
(1997)
Anticancer Res
, vol.17
, pp. 3055-3058
-
-
Hasholzner, U.1
Stieber, P.2
Meier, W.3
Lamerz, R.4
-
15
-
-
0024268439
-
Escape from blocking of interfering heterophile antibodies in a two-site immunoradiometric assay for thyrotropin
-
Zweig MH, Csako G, Spero M. Escape from blocking of interfering heterophile antibodies in a two-site immunoradiometric assay for thyrotropin. Clin Chem 1988; 34:2589-91.
-
(1988)
Clin Chem
, vol.34
, pp. 2589-2591
-
-
Zweig, M.H.1
Csako, G.2
Spero, M.3
-
16
-
-
0023359668
-
Interference by anti-immunoglobulin G antibodies in immunoradiometric assays of thyrotropin involving mouse monoclonal antibodies
-
Zweig MH, Csako G, Benson CC, Weintraub BD, Kahn BB. Interference by anti-immunoglobulin G antibodies in immunoradiometric assays of thyrotropin involving mouse monoclonal antibodies. Clin Chem 1987; 33:840-4.
-
(1987)
Clin Chem
, vol.33
, pp. 840-844
-
-
Zweig, M.H.1
Csako, G.2
Benson, C.C.3
Weintraub, B.D.4
Kahn, B.B.5
-
17
-
-
0023846125
-
"Sandwich"-type immunoassay of carcinoembryonic antigen in patients receiving murine monoclonal antibodies for diagnosis and therapy
-
Primus FJ, Kelley EA, Hansen HJ, Goldenberg DM. "Sandwich"-type immunoassay of carcinoembryonic antigen in patients receiving murine monoclonal antibodies for diagnosis and therapy. Clin Chem 1988; 34:261-4.
-
(1988)
Clin Chem
, vol.34
, pp. 261-264
-
-
Primus, F.J.1
Kelley, E.A.2
Hansen, H.J.3
Goldenberg, D.M.4
-
18
-
-
0024252555
-
Tolerogenic conjugates of xenogenic monoclonal antibodies with monomethoxy-polyethylene glycol. I. Induction of long-lasting tolerance to xenogeneic monoclonal antibodies
-
Maita PK, Lang GM, Sehon AH. Tolerogenic conjugates of xenogenic monoclonal antibodies with monomethoxy-polyethylene glycol. I. Induction of long-lasting tolerance to xenogeneic monoclonal antibodies. Int J Cancer 1988; 41:Suppl 3:17-22.
-
(1988)
Int J Cancer
, vol.41
, Issue.SUPPL. 3
, pp. 17-22
-
-
Maita, P.K.1
Lang, G.M.2
Sehon, A.H.3
-
19
-
-
0024322229
-
Murine monoclonal antibody adsorbed onto vinylidine fluoride floccules used to eliminate antibody interference in "sandwich"-type immunoassays
-
Newman ES, Moskie LA, Duggal RN, Goldenberg DM, Hansen HJ. Murine monoclonal antibody adsorbed onto vinylidine fluoride floccules used to eliminate antibody interference in "sandwich"-type immunoassays. Clin Chem 1989; 35:1743-6.
-
(1989)
Clin Chem
, vol.35
, pp. 1743-1746
-
-
Newman, E.S.1
Moskie, L.A.2
Duggal, R.N.3
Goldenberg, D.M.4
Hansen, H.J.5
-
20
-
-
0023802678
-
The potency of immunoglobulin G fragments for inhibition of interference caused by anti-immunoglobulin antibodies in a monoclonal immunoradiometric assay for thyrotropin
-
Csako G, Weintraub BD, Zweig MH. The potency of immunoglobulin G fragments for inhibition of interference caused by anti-immunoglobulin antibodies in a monoclonal immunoradiometric assay for thyrotropin. Clin Chem 1988; 34:1481-3.
-
(1988)
Clin Chem
, vol.34
, pp. 1481-1483
-
-
Csako, G.1
Weintraub, B.D.2
Zweig, M.H.3
-
21
-
-
0021251584
-
Transient autoantibodies with elevated complement levels in common viral diseases
-
Niwa Y, Sakane T, Kanoh T, Shichijo S, Wiederhold MD, Yokoyama MM. Transient autoantibodies with elevated complement levels in common viral diseases. Clin Lab Immunol 1984; 13:183-8.
-
(1984)
Clin Lab Immunol
, vol.13
, pp. 183-188
-
-
Niwa, Y.1
Sakane, T.2
Kanoh, T.3
Shichijo, S.4
Wiederhold, M.D.5
Yokoyama, M.M.6
-
22
-
-
0029913059
-
Different efficacy of various blocking reagents to eliminate interferences by human antimouse antibodies with a two-site immunoassay
-
Reinsberg J. Different efficacy of various blocking reagents to eliminate interferences by human antimouse antibodies with a two-site immunoassay. Clin Biochem 1996; 29:145-8.
-
(1996)
Clin Biochem
, vol.29
, pp. 145-148
-
-
Reinsberg, J.1
-
23
-
-
0030841625
-
Measures to overcome HAMA interferences in immunoassays
-
Madry N, Auerbach B, Schelp C. Measures to overcome HAMA interferences in immunoassays. Anticancer Res 1997; 17:2883-6.
-
(1997)
Anticancer Res
, vol.17
, pp. 2883-2886
-
-
Madry, N.1
Auerbach, B.2
Schelp, C.3
|