메뉴 건너뛰기




Volumn 38, Issue 1, 2000, Pages 33-39

Transient nature of interference effects from heterophile antibodies: Examples of interference with cardiac marker measurements

Author keywords

Cardiac marker measurement; Human anti murine antibodies; Interference

Indexed keywords

BIOLOGICAL MARKER; CREATINE KINASE MB; HETEROPHILE ANTIBODY; IMMUNOGLOBULIN; TROPONIN I; TROPONIN T;

EID: 0034026889     PISSN: 14346621     EISSN: None     Source Type: Journal    
DOI: 10.1515/CCLM.2000.006     Document Type: Article
Times cited : (34)

References (23)
  • 1
    • 0022918233 scopus 로고
    • Incidence and specificity of interference in two-site immunoassays
    • Boscato LM, Stuart MC. Incidence and specificity of interference in two-site immunoassays. Clin Chem 1986; 32:1491-5.
    • (1986) Clin Chem , vol.32 , pp. 1491-1495
    • Boscato, L.M.1    Stuart, M.C.2
  • 2
    • 0031911110 scopus 로고    scopus 로고
    • Antibody interference in thyroid assays: A potential for clinical misinformation
    • Després N, Grant AM. Antibody interference in thyroid assays: a potential for clinical misinformation. [Review] Clin Chem 1998; 44:440-54.
    • (1998) [Review] Clin Chem , vol.44 , pp. 440-454
    • Després, N.1    Grant, A.M.2
  • 3
    • 0030765913 scopus 로고    scopus 로고
    • Heterophilic antibodies remain a problem for the immunoassay laboratory
    • Ward G, McKinnon L, Badrick T, Hickman PE. Heterophilic antibodies remain a problem for the immunoassay laboratory. Am J Clin Pathol 1997; 108:417-21.
    • (1997) Am J Clin Pathol , vol.108 , pp. 417-421
    • Ward, G.1    McKinnon, L.2    Badrick, T.3    Hickman, P.E.4
  • 4
    • 0029128635 scopus 로고
    • Falsely elevated steroidal assay levels related to heterophile antibodies against various animal species
    • Check JH, Ubelacker L, Lauer CC. Falsely elevated steroidal assay levels related to heterophile antibodies against various animal species. Gynecol Obstet Invest 1995; 40:139-40.
    • (1995) Gynecol Obstet Invest , vol.40 , pp. 139-140
    • Check, J.H.1    Ubelacker, L.2    Lauer, C.C.3
  • 5
    • 0030892115 scopus 로고    scopus 로고
    • Heterophilic antibodies produce spuriously elevated concentrations of the MB isoenzyme of creatine kinase in a selected patient population
    • Sosolik RC, Hitchcock CL, Becker WJ. Heterophilic antibodies produce spuriously elevated concentrations of the MB isoenzyme of creatine kinase in a selected patient population. Am J Clin Pathol 1997; 107:506-10.
    • (1997) Am J Clin Pathol , vol.107 , pp. 506-510
    • Sosolik, R.C.1    Hitchcock, C.L.2    Becker, W.J.3
  • 6
    • 0026013686 scopus 로고
    • Interference by iatrogenically induced anti-mouse IgG antibodies in a two-site immunometric assay for thyrotropin
    • Zweig MH, Csako G, Reynolds JC, Carrasquillo JA. Interference by iatrogenically induced anti-mouse IgG antibodies in a two-site immunometric assay for thyrotropin. Arch Pathol Lab Med 1991; 115:164-8.
    • (1991) Arch Pathol Lab Med , vol.115 , pp. 164-168
    • Zweig, M.H.1    Csako, G.2    Reynolds, J.C.3    Carrasquillo, J.A.4
  • 8
    • 0025981995 scopus 로고
    • Human antimurine antibody interference in measurement of carcinoembryonic antigen assessed with a double-antibody enzyme immunoassay
    • Price T, Beatty BG, Beatty JD, McNally AJ. Human antimurine antibody interference in measurement of carcinoembryonic antigen assessed with a double-antibody enzyme immunoassay. Clin Chem 1991; 37:51-7.
    • (1991) Clin Chem , vol.37 , pp. 51-57
    • Price, T.1    Beatty, B.G.2    Beatty, J.D.3    McNally, A.J.4
  • 10
    • 0022909145 scopus 로고
    • Artefactual increase in serum thyrotropin concentration caused by heterophilic antibodies with specificity for IgG of the family bovidea
    • Bartlett WA, Browning MCK, Jung RT. Artefactual increase in serum thyrotropin concentration caused by heterophilic antibodies with specificity for IgG of the family bovidea. Clin Chem 1986; 32:2214-9.
    • (1986) Clin Chem , vol.32 , pp. 2214-2219
    • Bartlett, W.A.1    Browning, M.C.K.2    Jung, R.T.3
  • 11
    • 0026389671 scopus 로고
    • Sudden appearance and subsequent disappearance of interference in immunometric assays of thyrotropin neutralizable with purified mouse IgG
    • Wickus GG, Caplan RH, Mathews EA, Pehling GB. Sudden appearance and subsequent disappearance of interference in immunometric assays of thyrotropin neutralizable with purified mouse IgG. [Editorial]. Clin Chem 1991; 37:595-6.
    • (1991) Clin Chem , vol.37 , pp. 595-596
    • Wickus, G.G.1    Caplan, R.H.2    Mathews, E.A.3    Pehling, G.B.4
  • 12
    • 0026702425 scopus 로고
    • 2 conjugate and polyclonal mouse IgG
    • 2 conjugate and polyclonal mouse IgG. Clin Chem 1992; 38:1737-42.
    • (1992) Clin Chem , vol.38 , pp. 1737-1742
    • Vaidya, H.C.1    Beatty, B.G.2
  • 13
    • 0031710957 scopus 로고    scopus 로고
    • False increases of cardiac troponin I with heterophilic antibodies
    • Fitzmaurice TF, Brown C, Rifai N, Wu AHB, Yeo KJ. False increases of cardiac troponin I with heterophilic antibodies. Clin Chem 1998; 44:2212-3.
    • (1998) Clin Chem , vol.44 , pp. 2212-2213
    • Fitzmaurice, T.F.1    Brown, C.2    Rifai, N.3    Wu, A.H.B.4    Yeo, K.J.5
  • 14
    • 0030610825 scopus 로고    scopus 로고
    • Value of HAMA determination in clinical practice- an overview
    • Hasholzner U, Stieber P, Meier W, Lamerz R. Value of HAMA determination in clinical practice- an overview. Anticancer Res 1997; 17:3055-8.
    • (1997) Anticancer Res , vol.17 , pp. 3055-3058
    • Hasholzner, U.1    Stieber, P.2    Meier, W.3    Lamerz, R.4
  • 15
    • 0024268439 scopus 로고
    • Escape from blocking of interfering heterophile antibodies in a two-site immunoradiometric assay for thyrotropin
    • Zweig MH, Csako G, Spero M. Escape from blocking of interfering heterophile antibodies in a two-site immunoradiometric assay for thyrotropin. Clin Chem 1988; 34:2589-91.
    • (1988) Clin Chem , vol.34 , pp. 2589-2591
    • Zweig, M.H.1    Csako, G.2    Spero, M.3
  • 16
    • 0023359668 scopus 로고
    • Interference by anti-immunoglobulin G antibodies in immunoradiometric assays of thyrotropin involving mouse monoclonal antibodies
    • Zweig MH, Csako G, Benson CC, Weintraub BD, Kahn BB. Interference by anti-immunoglobulin G antibodies in immunoradiometric assays of thyrotropin involving mouse monoclonal antibodies. Clin Chem 1987; 33:840-4.
    • (1987) Clin Chem , vol.33 , pp. 840-844
    • Zweig, M.H.1    Csako, G.2    Benson, C.C.3    Weintraub, B.D.4    Kahn, B.B.5
  • 17
    • 0023846125 scopus 로고
    • "Sandwich"-type immunoassay of carcinoembryonic antigen in patients receiving murine monoclonal antibodies for diagnosis and therapy
    • Primus FJ, Kelley EA, Hansen HJ, Goldenberg DM. "Sandwich"-type immunoassay of carcinoembryonic antigen in patients receiving murine monoclonal antibodies for diagnosis and therapy. Clin Chem 1988; 34:261-4.
    • (1988) Clin Chem , vol.34 , pp. 261-264
    • Primus, F.J.1    Kelley, E.A.2    Hansen, H.J.3    Goldenberg, D.M.4
  • 18
    • 0024252555 scopus 로고
    • Tolerogenic conjugates of xenogenic monoclonal antibodies with monomethoxy-polyethylene glycol. I. Induction of long-lasting tolerance to xenogeneic monoclonal antibodies
    • Maita PK, Lang GM, Sehon AH. Tolerogenic conjugates of xenogenic monoclonal antibodies with monomethoxy-polyethylene glycol. I. Induction of long-lasting tolerance to xenogeneic monoclonal antibodies. Int J Cancer 1988; 41:Suppl 3:17-22.
    • (1988) Int J Cancer , vol.41 , Issue.SUPPL. 3 , pp. 17-22
    • Maita, P.K.1    Lang, G.M.2    Sehon, A.H.3
  • 19
    • 0024322229 scopus 로고
    • Murine monoclonal antibody adsorbed onto vinylidine fluoride floccules used to eliminate antibody interference in "sandwich"-type immunoassays
    • Newman ES, Moskie LA, Duggal RN, Goldenberg DM, Hansen HJ. Murine monoclonal antibody adsorbed onto vinylidine fluoride floccules used to eliminate antibody interference in "sandwich"-type immunoassays. Clin Chem 1989; 35:1743-6.
    • (1989) Clin Chem , vol.35 , pp. 1743-1746
    • Newman, E.S.1    Moskie, L.A.2    Duggal, R.N.3    Goldenberg, D.M.4    Hansen, H.J.5
  • 20
    • 0023802678 scopus 로고
    • The potency of immunoglobulin G fragments for inhibition of interference caused by anti-immunoglobulin antibodies in a monoclonal immunoradiometric assay for thyrotropin
    • Csako G, Weintraub BD, Zweig MH. The potency of immunoglobulin G fragments for inhibition of interference caused by anti-immunoglobulin antibodies in a monoclonal immunoradiometric assay for thyrotropin. Clin Chem 1988; 34:1481-3.
    • (1988) Clin Chem , vol.34 , pp. 1481-1483
    • Csako, G.1    Weintraub, B.D.2    Zweig, M.H.3
  • 22
    • 0029913059 scopus 로고    scopus 로고
    • Different efficacy of various blocking reagents to eliminate interferences by human antimouse antibodies with a two-site immunoassay
    • Reinsberg J. Different efficacy of various blocking reagents to eliminate interferences by human antimouse antibodies with a two-site immunoassay. Clin Biochem 1996; 29:145-8.
    • (1996) Clin Biochem , vol.29 , pp. 145-148
    • Reinsberg, J.1
  • 23
    • 0030841625 scopus 로고    scopus 로고
    • Measures to overcome HAMA interferences in immunoassays
    • Madry N, Auerbach B, Schelp C. Measures to overcome HAMA interferences in immunoassays. Anticancer Res 1997; 17:2883-6.
    • (1997) Anticancer Res , vol.17 , pp. 2883-2886
    • Madry, N.1    Auerbach, B.2    Schelp, C.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.