메뉴 건너뛰기




Volumn 378, Issue 1-2, 2007, Pages 225-226

Unnecessary coronary angiography due to false positive troponin I results in a 51-year-old man

Author keywords

[No Author keywords available]

Indexed keywords

AUTOANTIBODY; HETEROPHILE ANTIBODY; IMMUNOGLOBULIN M; RHEUMATOID FACTOR; TROPONIN I;

EID: 33847006249     PISSN: 00098981     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.cca.2006.10.007     Document Type: Letter
Times cited : (11)

References (9)
  • 1
    • 0033851515 scopus 로고    scopus 로고
    • Myocardial infarction redefined-a consensus document of The Joint European Society of Cardiology/American College of Cardiology Committee for the redefinition of myocardial infarction
    • Alpert J.S., Thygesen K., Antman E., and Bassand J.P. Myocardial infarction redefined-a consensus document of The Joint European Society of Cardiology/American College of Cardiology Committee for the redefinition of myocardial infarction. J Am Coll Cardiol 36 (2000) 959-969
    • (2000) J Am Coll Cardiol , vol.36 , pp. 959-969
    • Alpert, J.S.1    Thygesen, K.2    Antman, E.3    Bassand, J.P.4
  • 2
    • 15944396595 scopus 로고    scopus 로고
    • Cardiac troponin I and C: analytical comparison and clinical-biological interpretation of three troponins assays
    • Bionda C., Pettazzoni M., Rodriguez-Lafrasse C., Ardail D., and Rousson R. Cardiac troponin I and C: analytical comparison and clinical-biological interpretation of three troponins assays. Ann Biol Clin (Paris) 63 (2005) 185-192
    • (2005) Ann Biol Clin (Paris) , vol.63 , pp. 185-192
    • Bionda, C.1    Pettazzoni, M.2    Rodriguez-Lafrasse, C.3    Ardail, D.4    Rousson, R.5
  • 3
    • 0031710957 scopus 로고    scopus 로고
    • False increase of cardiac troponin I with heterophilic antibodies
    • Fitzmaurice T.F., Brown C., Rifai N., Wu A.H., and Yeo K.T. False increase of cardiac troponin I with heterophilic antibodies. Clin Chem 44 (1998) 2212-2214
    • (1998) Clin Chem , vol.44 , pp. 2212-2214
    • Fitzmaurice, T.F.1    Brown, C.2    Rifai, N.3    Wu, A.H.4    Yeo, K.T.5
  • 4
    • 0030330910 scopus 로고    scopus 로고
    • False-negative immunoassay results for cardiac troponin I probably due to circulating troponin I autoantibodies
    • Bohner J., von Pape K.W., Hannes W., and Stegmann T. False-negative immunoassay results for cardiac troponin I probably due to circulating troponin I autoantibodies. Clin Chem 42 (1996) 2046
    • (1996) Clin Chem , vol.42 , pp. 2046
    • Bohner, J.1    von Pape, K.W.2    Hannes, W.3    Stegmann, T.4
  • 5
    • 0033869592 scopus 로고    scopus 로고
    • An IgM lambda antibody to Escherichia coli produces false-positive results in multiple immunometric assays
    • Covinsky M., Laterza O., Pfeifer J.D., Farkas-Szallasi T., and Scott M.G. An IgM lambda antibody to Escherichia coli produces false-positive results in multiple immunometric assays. Clin Chem 46 (2000) 1157-1161
    • (2000) Clin Chem , vol.46 , pp. 1157-1161
    • Covinsky, M.1    Laterza, O.2    Pfeifer, J.D.3    Farkas-Szallasi, T.4    Scott, M.G.5
  • 6
    • 0032814344 scopus 로고    scopus 로고
    • Human anti-animal antibody interferences in immunological assays
    • [Review]
    • Kricka L.J. Human anti-animal antibody interferences in immunological assays. Clin Chem 45 (1999) 942-956 [Review]
    • (1999) Clin Chem , vol.45 , pp. 942-956
    • Kricka, L.J.1
  • 7
    • 0033248168 scopus 로고    scopus 로고
    • False-positive troponin I in the MEIA due to the presence of rheumatoid factors in serum. Elimination of this interference by using a polyclonal antisera against rheumatoid factors
    • Dasgupta A., Banerjee S.K., and Datta P. False-positive troponin I in the MEIA due to the presence of rheumatoid factors in serum. Elimination of this interference by using a polyclonal antisera against rheumatoid factors. Am J Clin Pathol 112 (1999) 753-756
    • (1999) Am J Clin Pathol , vol.112 , pp. 753-756
    • Dasgupta, A.1    Banerjee, S.K.2    Datta, P.3
  • 8
    • 3242659235 scopus 로고    scopus 로고
    • Quality specifications for biochemical markers of myocardial injury
    • Zaninotto M., Mion M., Altinier S., Forni M., and Plebani M. Quality specifications for biochemical markers of myocardial injury. Clin Chim Acta 346 (2004) 65-72
    • (2004) Clin Chim Acta , vol.346 , pp. 65-72
    • Zaninotto, M.1    Mion, M.2    Altinier, S.3    Forni, M.4    Plebani, M.5
  • 9
    • 0037934622 scopus 로고    scopus 로고
    • Screening for interference in immunoassays
    • Emerson J.F., Ngo G., and Emerson S.S. Screening for interference in immunoassays. Clin Chem 49 (2003) 1163-1169
    • (2003) Clin Chem , vol.49 , pp. 1163-1169
    • Emerson, J.F.1    Ngo, G.2    Emerson, S.S.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.