메뉴 건너뛰기




Volumn 122, Issue 1306, 2009, Pages 130-132

Heterophile antibodies and troponin results: Implications in rural setting

Author keywords

[No Author keywords available]

Indexed keywords

CA 125 ANTIGEN; CREATINE KINASE MB; HETEROPHILE ANTIBODY; IMMUNOGLOBULIN F(AB) FRAGMENT; IMMUNOGLOBULIN FC FRAGMENT; IMMUNOGLOBULIN G; TROPONIN; TROPONIN I; TROPONIN T;

EID: 71649083738     PISSN: None     EISSN: 11758716     Source Type: Journal    
DOI: None     Document Type: Letter
Times cited : (5)

References (22)
  • 3
    • 0036403028 scopus 로고    scopus 로고
    • Causes of elevated troponin with a normal coronary angiogram
    • Bakshi T, Choo MFK, Edwards CC, et al. Causes of elevated troponin with a normal coronary angiogram. Intern. Med. J. 2002;32: 520-525
    • (2002) Intern. Med. J. , vol.32 , pp. 520-525
    • Bakshi, T.1    Choo, M.F.K.2    Edwards, C.C.3
  • 4
    • 2442438574 scopus 로고    scopus 로고
    • Common Causes of Troponin Elevations in the Absence of Acute Myocardial Infarction
    • Roongstritong C, Warraich I, Bradley C. Common Causes of Troponin Elevations in the Absence of Acute Myocardial Infarction. Chest 2004;125: 1877-1884.
    • (2004) Chest , vol.125 , pp. 1877-1884
    • Roongstritong, C.1    Warraich, I.2    Bradley, C.3
  • 6
    • 0032814344 scopus 로고    scopus 로고
    • Human anti animal antibody interferences in immunological assays
    • Kricka LJ. Human anti animal antibody interferences in immunological assays. Clin chem. 1999;45:942-956
    • (1999) Clin Chem. , vol.45 , pp. 942-956
    • Kricka, L.J.1
  • 7
    • 0036844469 scopus 로고    scopus 로고
    • Towards a better understanding of heterophile (and the like) antibody interference with modern immunoassays
    • Levinson SS, Miller JJ. Towards a better understanding of heterophile (and the like) antibody interference with modern immunoassays. Clin chem. Acta 2002;325:1-15.
    • (2002) Clin Chem. Acta , vol.325 , pp. 1-15
    • Levinson, S.S.1    Miller, J.J.2
  • 8
    • 0036840561 scopus 로고    scopus 로고
    • Wrong biochemistry results: Two case reports and observational study in 5310 patients on potentially misleading thyroid-stimulating hormone and gonadotropin immunoassay results
    • Ismail AA, Walker PL, Barth JH, Lewandowski KC, Jones R, Burr WA. Wrong Biochemistry results:Two case reports and observational study in 5310 patients on potentially misleading thyroid stimulating hormone and gonaotrophin immunoassay results. Clin Chem 2002;48:2023-2029 (Pubitemid 35222761)
    • (2002) Clinical Chemistry , vol.48 , Issue.11 , pp. 2023-2029
    • Ismail, A.A.A.1    Walker, P.L.2    Barth, J.H.3    Lewandowski, K.C.4    Jones, R.5    Burr, W.A.6
  • 9
    • 0023853204 scopus 로고
    • Heterophilic antibodies: A problem for all immunoassays
    • Boscato Lm, Stuart MC. Heterophilic antibodies: a problem for all immunoassays. Clin chem.1988;34:27-33.
    • (1988) Clin Chem , vol.34 , pp. 27-33
    • Lm, B.1    Stuart, M.C.2
  • 11
    • 0033248168 scopus 로고    scopus 로고
    • False positive troponin I in the MEIA due to the presence of rheumatoid factors in serum
    • Dasgupta A, Banjiree SK, Datta P. False positive troponin I in the MEIA due to the presence of rheumatoid factors in serum. Am J Clin Pathol 1999;112:753-756.
    • (1999) Am J Clin Pathol , vol.112 , pp. 753-756
    • Dasgupta, A.1    Banjiree, S.K.2    Datta, P.3
  • 12
    • 0033869592 scopus 로고    scopus 로고
    • An IgM antibody to Escherichia coli produces false-positive results in multiple immunometric assays
    • Covinsky M, Laterza O, Pfeifer JD, et al. An IgM antibody to Escherichia coli produces falsepositive results in multiple immunometric assays. Clin Chem 2000;46:1157-1161 (Pubitemid 30643319)
    • (2000) Clinical Chemistry , vol.46 , Issue.8 I , pp. 1157-1161
    • Covinsky, M.1    Laterza, O.2    Pfeifer, J.D.3    Farkas-Szallasi, T.4    Scott, M.G.5
  • 13
    • 0022918233 scopus 로고
    • Incidence and specificity of interference in two site immunoassays
    • Boscato LM, Stuart MC. Incidence and specificity of interference in two site immunoassays. Clin Chem 1986;32:1491-1495
    • (1986) Clin Chem , vol.32 , pp. 1491-1495
    • Boscato, L.M.1    Stuart, M.C.2
  • 14
    • 0032814344 scopus 로고    scopus 로고
    • Human anti-animal antibody interference in immunologic assays
    • Kricka LJ. Human anti-animal antibody interference in immunologic assays. Clin Chem 1999;45:942-956
    • (1999) Clin Chem , vol.45 , pp. 942-956
    • Kricka, L.J.1
  • 15
    • 0022881264 scopus 로고
    • Circulating antibodies to mouse monoclonal immunoglobulins in normal subjects: Incidence, species specificity, and effects on a two-site assay for creatine kinase-MB isoenzyme
    • Thompson RJ, Jackson AP, Langlios N. Circulating antibodies to mouse monoclonal immunoglobulins in normal subjects: incidence, species specificity, and effects on a two-site assay for creatine kinase-MB isoenzyme. Clin Chem 1986;32:476-481
    • (1986) Clin Chem , vol.32 , pp. 476-481
    • Thompson, R.J.1    Jackson, A.P.2    Langlios, N.3
  • 16
    • 18444375563 scopus 로고    scopus 로고
    • Performance of a revised cardiac troponin method that minimizes interferences from heterophilic antibodies
    • Kim WJ, Lazerta OF, Hock KG, et al. Performance of a revised cardiac troponin method that minimizes interferences from heterophilic antibodies. Clin Chem 2002;48:1028-1034
    • (2002) Clin Chem , vol.48 , pp. 1028-1034
    • Kim, W.J.1    Lazerta, O.F.2    Hock, K.G.3
  • 17
    • 0029080326 scopus 로고
    • The incidence of antibody formation to OKT3 consequent to its use in organ transplantation
    • Carey G, Lisi PJ, Schroeder TJ. The incidence of antibody formation to OKT3 consequent to its use in organ transplantation. Transplantation 1995;60:151-158
    • (1995) Transplantation , vol.60 , pp. 151-158
    • Carey, G.1    Lisi, P.J.2    Schroeder, T.J.3
  • 18
    • 0031004589 scopus 로고    scopus 로고
    • When do microbes stimulate rheumatoid factor?
    • Posnet DN, Edinger J. When do microbes stimulate rheumatoid factor? J Exp Med 1997;185:1721-1723
    • (1997) J Exp Med , vol.185 , pp. 1721-1723
    • Posnet, D.N.1    Edinger, J.2
  • 19
    • 0025346127 scopus 로고
    • Heterophilic antibodies in human sera causing falsely increased results in the CA 125 immunofluorometric assay
    • Boerman OC, Segers MFG, Poels LG, Kenemans P, Thomas CMG. Heterophilic antibodies in human sera causing falsely increased results in the CA-125 immunofluorometric assay. Clin Chem 1990;36:888-891 (Pubitemid 20189259)
    • (1990) Clinical Chemistry , vol.36 , Issue.6 , pp. 888-891
    • Boerman, O.C.1    Segers, M.F.G.2    Poels, L.G.3    Kenemans, P.4    Thomas, C.M.G.5
  • 20
    • 0028826885 scopus 로고
    • CA 125 determined by three methods in samples from patients with human anti-mouse antibodies (HAMA)
    • Turpeinen U, Lehtovirta P, Stenman U. CA 125 determined by three methods in samples from patients with human anti-mouse antibodies (HAMA). Clin Chem 1995;41:1667-1669
    • (1995) Clin Chem , vol.41 , pp. 1667-1669
    • Turpeinen, U.1    Lehtovirta, P.2    Stenman, U.3
  • 21
    • 0030892115 scopus 로고    scopus 로고
    • Heterophilic antibodies produce spuriously elevated concentrations of the MB isozyme of creatine kinase in a selected patient population
    • Sosolik RC, Hitchcock CL, Becker WJ. Heterophilic antibodies produce spuriously elevated concentrations of the MB isozyme of creatine kinase in a selected patient population. Am J Clin Pathol 1997;107:506-510
    • (1997) Am J Clin Pathol , vol.107 , pp. 506-510
    • Sosolik, R.C.1    Hitchcock, C.L.2    Becker, W.J.3
  • 22
    • 71649092636 scopus 로고    scopus 로고
    • Online cited 2009 Sept 09
    • Scantibodies Laboratory, Inc. [Online]. 2009 [cited 2009 Sept 09]. http://www.scantibodies.com/hbr.html#scanhbr
    • (2009)


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.