메뉴 건너뛰기




Volumn 4, Issue 5, 2013, Pages 661-669

Comparison of image quality between filtered back-projection and the adaptive statistical and novel model-based iterative reconstruction techniques in abdominal CT for renal calculi

Author keywords

Computed tomography; Image enhancement; Image processing; Urolithiasis

Indexed keywords


EID: 84884559428     PISSN: None     EISSN: 18694101     Source Type: Journal    
DOI: 10.1007/s13244-013-0273-5     Document Type: Article
Times cited : (42)

References (28)
  • 1
    • 0036828479 scopus 로고    scopus 로고
    • CT in detecting urinary tract calculi: influence on patient imaging and clinical outcomes
    • Gottlieb RH, La TC, Erturk EN et al (2002) CT in detecting urinary tract calculi: influence on patient imaging and clinical outcomes. Radiology 225: 441-449.
    • (2002) Radiology , vol.225 , pp. 441-449
    • Gottlieb, R.H.1    La, T.C.2    Erturk, E.N.3
  • 3
    • 64949128238 scopus 로고    scopus 로고
    • Urinary calculi: radiation dose reduction of 50% and 75% at CT-effect on sensitivity 1
    • Ciaschini MW, Remer EM, Baker ME et al (2009) Urinary calculi: radiation dose reduction of 50% and 75% at CT-effect on sensitivity 1. Radiology 251: 105-111.
    • (2009) Radiology , vol.251 , pp. 105-111
    • Ciaschini, M.W.1    Remer, E.M.2    Baker, M.E.3
  • 4
    • 77950447085 scopus 로고    scopus 로고
    • Effect of reduced radiation CT protocols on the detection of renal calculi
    • Jin DH, Lamberton GR, Broome DR et al (2010) Effect of reduced radiation CT protocols on the detection of renal calculi. Radiology 255: 100-107.
    • (2010) Radiology , vol.255 , pp. 100-107
    • Jin, D.H.1    Lamberton, G.R.2    Broome, D.R.3
  • 5
    • 84870516674 scopus 로고    scopus 로고
    • Image quality assessment in torso phantom comparing effects of varying automatic current modulation with filtered back projection, adaptive statistical, and model-based iterative reconstruction techniques in CT
    • Vardhanabhuti V, Olubaniyi B, Loader R et al (2012) Image quality assessment in torso phantom comparing effects of varying automatic current modulation with filtered back projection, adaptive statistical, and model-based iterative reconstruction techniques in CT. J Med Imaging Radiat Sci 43: 228-238.
    • (2012) J Med Imaging Radiat Sci , vol.43 , pp. 228-238
    • Vardhanabhuti, V.1    Olubaniyi, B.2    Loader, R.3
  • 6
    • 79952267021 scopus 로고    scopus 로고
    • Impact of adaptive statistical iterative reconstruction (ASIR) on radiation dose and image quality in aortic dissection studies: a qualitative and quantitative analysis
    • Cornfeld D, Israel G, Detroy E et al (2011) Impact of adaptive statistical iterative reconstruction (ASIR) on radiation dose and image quality in aortic dissection studies: a qualitative and quantitative analysis. Am J Roentgenol 196: W336-W340.
    • (2011) Am J Roentgenol , vol.196
    • Cornfeld, D.1    Israel, G.2    Detroy, E.3
  • 7
    • 79955036642 scopus 로고    scopus 로고
    • Adaptive statistical iterative reconstruction technique for radiation dose reduction in chest CT: a pilot study
    • Singh S, Kalra MK, Gilman MD et al (2011) Adaptive statistical iterative reconstruction technique for radiation dose reduction in chest CT: a pilot study. Radiology 259: 565-573.
    • (2011) Radiology , vol.259 , pp. 565-573
    • Singh, S.1    Kalra, M.K.2    Gilman, M.D.3
  • 8
    • 77958569748 scopus 로고    scopus 로고
    • Abdominal CT: comparison of adaptive statistical iterative and filtered back projection reconstruction techniques
    • Singh S, Kalra MK, Hsieh J et al (2010) Abdominal CT: comparison of adaptive statistical iterative and filtered back projection reconstruction techniques. Radiology 257: 373-383.
    • (2010) Radiology , vol.257 , pp. 373-383
    • Singh, S.1    Kalra, M.K.2    Hsieh, J.3
  • 9
    • 84863666413 scopus 로고    scopus 로고
    • Model-based iterative reconstruction technique for ultralow-dose computed tomography of the lung: a pilot study
    • Yamada Y, Jinzaki M, Tanami Y et al (2012) Model-based iterative reconstruction technique for ultralow-dose computed tomography of the lung: a pilot study. Invest Radiol 47: 482-489.
    • (2012) Invest Radiol , vol.47 , pp. 482-489
    • Yamada, Y.1    Jinzaki, M.2    Tanami, Y.3
  • 10
    • 84864713607 scopus 로고    scopus 로고
    • Model-based iterative reconstruction technique for radiation dose reduction in chest CT: comparison with the adaptive statistical iterative reconstruction technique
    • Katsura M, Matsuda I, Akahane M et al (2012) Model-based iterative reconstruction technique for radiation dose reduction in chest CT: comparison with the adaptive statistical iterative reconstruction technique. Eur Radiol 22: 1613-1623.
    • (2012) Eur Radiol , vol.22 , pp. 1613-1623
    • Katsura, M.1    Matsuda, I.2    Akahane, M.3
  • 11
    • 84863721418 scopus 로고    scopus 로고
    • Radiation dose reduction in abdominal computed tomography during the late hepatic arterial phase using a model-based iterative reconstruction algorithm: how low can we go?
    • Husarik DB, Marin D, Samei E et al (2012) Radiation dose reduction in abdominal computed tomography during the late hepatic arterial phase using a model-based iterative reconstruction algorithm: how low can we go? Invest Radiol 47: 468-474.
    • (2012) Invest Radiol , vol.47 , pp. 468-474
    • Husarik, D.B.1    Marin, D.2    Samei, E.3
  • 12
    • 77957358643 scopus 로고    scopus 로고
    • Multisection CT protocols: sex- and age-specific conversion factors used to determine effective dose from dose length product
    • Deak PD, Smal Y, Kalender WA (2010) Multisection CT protocols: sex- and age-specific conversion factors used to determine effective dose from dose length product. Radiology 257: 158-166.
    • (2010) Radiology , vol.257 , pp. 158-166
    • Deak, P.D.1    Smal, Y.2    Kalender, W.A.3
  • 13
    • 78651076120 scopus 로고    scopus 로고
    • Patient size compensated automatic tube current modulation in multi-detector row CT of the abdomen and pelvis
    • Li J, Udayasankar UK, Tang X, Toth TL, Small WC, Kalra MK (2011) Patient size compensated automatic tube current modulation in multi-detector row CT of the abdomen and pelvis. Acad Radiol 18: 205-211.
    • (2011) Acad Radiol , vol.18 , pp. 205-211
    • Li, J.1    Udayasankar, U.K.2    Tang, X.3    Toth, T.L.4    Small, W.C.5    Kalra, M.K.6
  • 15
    • 0031610920 scopus 로고    scopus 로고
    • Renal colic: comparison of spiral CT, US and IVU in the detection of ureteral calculi
    • Yilmaz S, Sindel T, Arslan G et al (1998) Renal colic: comparison of spiral CT, US and IVU in the detection of ureteral calculi. Eur Radiol 8: 212-217.
    • (1998) Eur Radiol , vol.8 , pp. 212-217
    • Yilmaz, S.1    Sindel, T.2    Arslan, G.3
  • 16
    • 0032802552 scopus 로고    scopus 로고
    • Unenhanced helical CT for suspected renal colic
    • Katz DS, Hines J, Rausch DR et al (1999) Unenhanced helical CT for suspected renal colic. AJR Am J Roentgenol 173: 425-430.
    • (1999) AJR Am J Roentgenol , vol.173 , pp. 425-430
    • Katz, D.S.1    Hines, J.2    Rausch, D.R.3
  • 17
    • 0036202292 scopus 로고    scopus 로고
    • Patients with acute flank pain: comparison of MR urography with unenhanced helical CT
    • Sudah M, Vanninen RL, Partanen K et al (2002) Patients with acute flank pain: comparison of MR urography with unenhanced helical CT. Radiology 223: 98-105.
    • (2002) Radiology , vol.223 , pp. 98-105
    • Sudah, M.1    Vanninen, R.L.2    Partanen, K.3
  • 18
    • 84866635102 scopus 로고    scopus 로고
    • Radiation dose reduction at multidetector CT with adaptive statistical iterative reconstruction for evaluation of urolithiasis: how low can we go?
    • Kulkarni NM, Uppot RN, Eisner BH, Sahani DV (2012) Radiation dose reduction at multidetector CT with adaptive statistical iterative reconstruction for evaluation of urolithiasis: how low can we go? Radiology 265(1): 158-166.
    • (2012) Radiology , vol.265 , Issue.1 , pp. 158-166
    • Kulkarni, N.M.1    Uppot, R.N.2    Eisner, B.H.3    Sahani, D.V.4
  • 19
    • 84873600660 scopus 로고    scopus 로고
    • Improved delineation of the anterior spinal artery with model-based iterative reconstruction in CT angiography: a clinical pilot study
    • Machida H, Tanaka I, Fukui R, Kita K, Shen Y, Ueno E, Suzuki S (2013) Improved delineation of the anterior spinal artery with model-based iterative reconstruction in CT angiography: a clinical pilot study. AJR Am J Roentgenol 200(2): 442-446.
    • (2013) AJR Am J Roentgenol , vol.200 , Issue.2 , pp. 442-446
    • Machida, H.1    Tanaka, I.2    Fukui, R.3    Kita, K.4    Shen, Y.5    Ueno, E.6    Suzuki, S.7
  • 20
    • 84871921772 scopus 로고    scopus 로고
    • Comparison of pure and hybrid iterative reconstruction techniques with conventional filtered back projection: image quality assessment in the cervicothoracic region
    • Katsura M, Sato J, Akahane M, Matsuda I, Ishida M, Yasaka K, Kunimatsu A, Ohtomo K (2013) Comparison of pure and hybrid iterative reconstruction techniques with conventional filtered back projection: image quality assessment in the cervicothoracic region. Eur J Radiol 82(2): 356-360.
    • (2013) Eur J Radiol , vol.82 , Issue.2 , pp. 356-360
    • Katsura, M.1    Sato, J.2    Akahane, M.3    Matsuda, I.4    Ishida, M.5    Yasaka, K.6    Kunimatsu, A.7    Ohtomo, K.8
  • 21
    • 84878511200 scopus 로고    scopus 로고
    • Improved delineation of arteries in the posterior fossa of the brain by model-based iterative reconstruction in volume-rendered 3D CT angiography
    • Machida H, Takeuchi H, Tanaka I, Fukui R, Shen Y, Ueno E, Suzuki S, Lin XZ (2013) Improved delineation of arteries in the posterior fossa of the brain by model-based iterative reconstruction in volume-rendered 3D CT angiography. AJNR Am J Neuroradiol 34(5): 971-5.
    • (2013) AJNR Am J Neuroradiol , vol.34 , Issue.5 , pp. 971-975
    • Machida, H.1    Takeuchi, H.2    Tanaka, I.3    Fukui, R.4    Shen, Y.5    Ueno, E.6    Suzuki, S.7    Lin, X.Z.8
  • 22
    • 84871698536 scopus 로고    scopus 로고
    • Filtered back projection, adaptive statistical iterative reconstruction, and a model-based iterative reconstruction in abdominal CT: an experimental clinical study
    • Deák Z, Grimm JM, Treitl M, Geyer LL, Linsenmaier U, Körner M, Reiser MF, Wirth S (2013) Filtered back projection, adaptive statistical iterative reconstruction, and a model-based iterative reconstruction in abdominal CT: an experimental clinical study. Radiology 266(1): 197-206.
    • (2013) Radiology , vol.266 , Issue.1 , pp. 197-206
    • Deák, Z.1    Grimm, J.M.2    Treitl, M.3    Geyer, L.L.4    Linsenmaier, U.5    Körner, M.6    Reiser, M.F.7    Wirth, S.8
  • 24
    • 84874935300 scopus 로고    scopus 로고
    • Model-based iterative reconstruction technique for ultralow-dose chest CT: comparison of pulmonary nodule detectability with the adaptive statistical iterative reconstruction technique
    • Katsura M, Matsuda I, Akahane M, Yasaka K, Hanaoka S, Akai H, Sato J, Kunimatsu A, Ohtomo K (2013) Model-based iterative reconstruction technique for ultralow-dose chest CT: comparison of pulmonary nodule detectability with the adaptive statistical iterative reconstruction technique. Invest Radiol 48(4): 206-212.
    • (2013) Invest Radiol , vol.48 , Issue.4 , pp. 206-212
    • Katsura, M.1    Matsuda, I.2    Akahane, M.3    Yasaka, K.4    Hanaoka, S.5    Akai, H.6    Sato, J.7    Kunimatsu, A.8    Ohtomo, K.9
  • 25
    • 84878598953 scopus 로고    scopus 로고
    • Computed tomography of the chest with model-based iterative reconstruction using a radiation exposure similar to chest X-ray examination: preliminary observations
    • Neroladaki A, Botsikas D, Boudabbous S, Becker CD, Montet X (2013) Computed tomography of the chest with model-based iterative reconstruction using a radiation exposure similar to chest X-ray examination: preliminary observations. Eur Radiol 23(2): 360-366.
    • (2013) Eur Radiol , vol.23 , Issue.2 , pp. 360-366
    • Neroladaki, A.1    Botsikas, D.2    Boudabbous, S.3    Becker, C.D.4    Montet, X.5
  • 26
    • 84876036668 scopus 로고    scopus 로고
    • Image quality assessment of standard- and low-dose chest CT using filtered back projection, adaptive statistical iterative reconstruction, and novel model-based iterative reconstruction algorithms
    • 2214
    • Vardhanabhuti V, Loader RJ, Mitchell GR, Riordan RD, Roobottom CA (2013) Image quality assessment of standard- and low-dose chest CT using filtered back projection, adaptive statistical iterative reconstruction, and novel model-based iterative reconstruction algorithms. AJR Am J Roentgenol 200: 10. 2214.
    • (2013) AJR Am J Roentgenol , vol.200 , pp. 10
    • Vardhanabhuti, V.1    Loader, R.J.2    Mitchell, G.R.3    Riordan, R.D.4    Roobottom, C.A.5
  • 27
    • 84870903463 scopus 로고    scopus 로고
    • Abdominal CT with model-based iterative reconstruction (MBIR): initial results of a prospective trial comparing ultralow-dose with standard-dose imaging
    • Pickhardt PJ, Lubner MG, Kim DH, Tang J, Ruma JA, del Rio AM, Chen GH (2012) Abdominal CT with model-based iterative reconstruction (MBIR): initial results of a prospective trial comparing ultralow-dose with standard-dose imaging. AJR Am J Roentgenol 199(6): 1266-1274.
    • (2012) AJR Am J Roentgenol , vol.199 , Issue.6 , pp. 1266-1274
    • Pickhardt, P.J.1    Lubner, M.G.2    Kim, D.H.3    Tang, J.4    Ruma, J.A.5    del Rio, A.M.6    Chen, G.H.7


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.