메뉴 건너뛰기




Volumn 47, Issue 8, 2012, Pages 482-489

Model-based iterative reconstruction technique for ultralow-dose computed tomography of the lung: A pilot study

Author keywords

chest; CT; image quality; iterative reconstruction; nodule

Indexed keywords

ADULT; AGED; ARTICLE; COMPUTER ASSISTED TOMOGRAPHY; CONTROLLED STUDY; HUMAN; IMAGE QUALITY; IMAGE RECONSTRUCTION; INFORMED CONSENT; INTERMETHOD COMPARISON; LOW DOSE COMPUTED TOMOGRAPHY; LUNG NODULE; MAJOR CLINICAL STUDY; MODEL BASED ITERATIVE RECONSTRUCTION; PRIORITY JOURNAL; RADIATION DOSE; RADIOLOGIST; RECEIVER OPERATING CHARACTERISTIC; ULTRALOW DOSE LUNG COMPUTED TOMOGRAPHY;

EID: 84863666413     PISSN: 00209996     EISSN: 15360210     Source Type: Journal    
DOI: 10.1097/RLI.0b013e3182562a89     Document Type: Article
Times cited : (126)

References (41)
  • 2
    • 79961108629 scopus 로고    scopus 로고
    • Reduced lung-cancer mortality with low-dose computed tomographic screening
    • Aberle DR, Adams AM, Berg CD, et al. Reduced lung-cancer mortality with low-dose computed tomographic screening. N Engl J Med. 2011;365:395-409.
    • (2011) N Engl J Med , vol.365 , pp. 395-409
    • Aberle, D.R.1    Adams, A.M.2    Berg, C.D.3
  • 3
    • 35649025312 scopus 로고    scopus 로고
    • A three-dimensional statistical approach to improved image quality for multislice helical CT
    • DOI 10.1118/1.2789499
    • Thibault JB, Sauer KD, Bouman CA, et al. A three-dimensional statistical approach to improved image quality for multislice helical CT. Med Phys. 2007;34:4526-4544. (Pubitemid 350029675)
    • (2007) Medical Physics , vol.34 , Issue.11 , pp. 4526-4544
    • Thibault, J.-B.1    Sauer, K.D.2    Bouman, C.A.3    Hsieh, J.4
  • 4
    • 76449091107 scopus 로고    scopus 로고
    • Radiation dose reduction with chest computed tomography using adaptive statistical iterative reconstruction technique: Initial experience
    • Prakash P, Kalra MK, Digumarthy SR, et al. Radiation dose reduction with chest computed tomography using adaptive statistical iterative reconstruction technique: initial experience. J Comput Assist Tomogr. 2010;34:40-45.
    • (2010) J Comput Assist Tomogr , vol.34 , pp. 40-45
    • Prakash, P.1    Kalra, M.K.2    Digumarthy, S.R.3
  • 5
    • 69949096664 scopus 로고    scopus 로고
    • Iterative reconstruction technique for reducing body radiation dose at CT: Feasibility study
    • Hara AK, Paden RG, Silva AC, et al. Iterative reconstruction technique for reducing body radiation dose at CT: feasibility study. AJR Am J Roentgenol. 2009;193:764-771.
    • (2009) AJR Am J Roentgenol , vol.193 , pp. 764-771
    • Hara, A.K.1    Paden, R.G.2    Silva, A.C.3
  • 6
    • 79955036642 scopus 로고    scopus 로고
    • Adaptive statistical iterative reconstruction technique for radiation dose reduction in chest CT: A pilot study
    • Singh S, Kalra MK, Gilman MD, et al. Adaptive statistical iterative reconstruction technique for radiation dose reduction in chest CT: a pilot study. Radiology. 2011;259:565-573.
    • (2011) Radiology , vol.259 , pp. 565-573
    • Singh, S.1    Kalra, M.K.2    Gilman, M.D.3
  • 7
    • 77953939681 scopus 로고    scopus 로고
    • Diffuse lung disease: CT of the chest with adaptive statistical iterative reconstruction technique
    • Prakash P, Kalra MK, Ackman JB, et al. Diffuse lung disease: CT of the chest with adaptive statistical iterative reconstruction technique. Radiology. 2010; 256:261-269.
    • (2010) Radiology , vol.256 , pp. 261-269
    • Prakash, P.1    Kalra, M.K.2    Ackman, J.B.3
  • 8
    • 78649700320 scopus 로고    scopus 로고
    • A prospective evaluation of dose reduction and image quality in chest CTusing adaptive statistical iterative reconstruction
    • Leipsic J, Nguyen G, Brown J, et al. A prospective evaluation of dose reduction and image quality in chest CTusing adaptive statistical iterative reconstruction. AJR Am J Roentgenol. 2010;195:1095-1099.
    • (2010) AJR Am J Roentgenol , vol.195 , pp. 1095-1099
    • Leipsic, J.1    Nguyen, G.2    Brown, J.3
  • 9
    • 79751534189 scopus 로고    scopus 로고
    • Chest computed tomography using iterative reconstruction vs filtered back projection (part 1): Evaluation of image noise reduction in 32 patients
    • Pontana F, Pagniez J, Flohr T, et al. Chest computed tomography using iterative reconstruction vs filtered back projection (part 1): evaluation of image noise reduction in 32 patients. Eur Radiol. 2011;21:627-635.
    • (2011) Eur Radiol , vol.21 , pp. 627-635
    • Pontana, F.1    Pagniez, J.2    Flohr, T.3
  • 10
    • 79751526184 scopus 로고    scopus 로고
    • Chest computed tomography using iterative reconstruction vs filtered back projection (part 2): Image quality of low-dose CT examinations in 80 patients
    • Pontana F, Duhamel A, Pagniez J, et al. Chest computed tomography using iterative reconstruction vs filtered back projection (part 2): image quality of low-dose CT examinations in 80 patients. Eur Radiol. 2011;21:636-643.
    • (2011) Eur Radiol , vol.21 , pp. 636-643
    • Pontana, F.1    Duhamel, A.2    Pagniez, J.3
  • 11
    • 79551517886 scopus 로고    scopus 로고
    • Fast model-based X-ray CT reconstruction using spatially nonhomogeneous ICD optimization
    • Yu Z, Thibault JB, Bouman CA, et al. Fast model-based X-ray CT reconstruction using spatially nonhomogeneous ICD optimization. IEEE Trans Image Process. 2011;20:161-175.
    • (2011) IEEE Trans Image Process , vol.20 , pp. 161-175
    • Yu, Z.1    Thibault, J.B.2    Bouman, C.A.3
  • 12
    • 84863229324 scopus 로고    scopus 로고
    • The national lung screening trial: Overview and study design
    • Aberle DR, Berg CD, Black WC, et al. The National Lung Screening Trial: overview and study design. Radiology. 2011;258:243-253.
    • (2011) Radiology , vol.258 , pp. 243-253
    • Aberle, D.R.1    Berg, C.D.2    Black, W.C.3
  • 13
    • 79953025769 scopus 로고    scopus 로고
    • UK Lung Screen (UKLS) nodule management protocol: Modelling of a single screen randomised controlled trial of low-dose CT screening for lung cancer
    • Baldwin DR, Duffy SW, Wald NJ, et al. UK Lung Screen (UKLS) nodule management protocol: modelling of a single screen randomised controlled trial of low-dose CT screening for lung cancer. Thorax. 2011;66:308-313.
    • (2011) Thorax , vol.66 , pp. 308-313
    • Baldwin, D.R.1    Duffy, S.W.2    Wald, N.J.3
  • 14
    • 77958569748 scopus 로고    scopus 로고
    • Abdominal CT: Comparison of adaptive statistical iterative and filtered back projection reconstruction techniques
    • Singh S, Kalra MK, Hsieh J, et al. Abdominal CT: comparison of adaptive statistical iterative and filtered back projection reconstruction techniques. Radiology. 2010;257:373-383.
    • (2010) Radiology , vol.257 , pp. 373-383
    • Singh, S.1    Kalra, M.K.2    Hsieh, J.3
  • 16
    • 4043148805 scopus 로고    scopus 로고
    • Observer studies involving detection and localization: Modeling, analysis, and validation
    • DOI 10.1118/1.1769352
    • Chakraborty DP, Berbaum KS. Observer studies involving detection and localization: modeling, analysis, and validation. Med Phys. 2004;31:2313-2330. (Pubitemid 39079724)
    • (2004) Medical Physics , vol.31 , Issue.8 , pp. 2313-2330
    • Chakraborty, D.P.1    Berbaum, K.S.2
  • 17
    • 17844393908 scopus 로고    scopus 로고
    • A comparison of two data analyses from two observer performance studies using Jackknife ROC and JAFROC
    • DOI 10.1118/1.1884766
    • Zheng B, Chakraborty DP, Rockette HE, et al. A comparison of two data analyses from two observer performance studies using Jackknife ROC and JAFROC. Med Phys. 2005;32:1031-1034. (Pubitemid 40586788)
    • (2005) Medical Physics , vol.32 , Issue.4 , pp. 1031-1034
    • Zheng, B.1    Chakraborty, D.P.2    Rockette, H.E.3    Maitz, G.S.4    Gur, D.5
  • 18
    • 33748427526 scopus 로고    scopus 로고
    • Analysis of Location Specific Observer Performance Data: Validated Extensions of the Jackknife Free-Response (JAFROC) Method
    • DOI 10.1016/j.acra.2006.06.016, PII S107663320600359X
    • Chakraborty DP. Analysis of location specific observer performance data: validated extensions of the jackknife free-response (JAFROC) method. Acad Radiol. 2006;13:1187-1193. (Pubitemid 44345253)
    • (2006) Academic Radiology , vol.13 , Issue.10 , pp. 1187-1193
    • Chakraborty, D.P.1
  • 19
    • 51549112607 scopus 로고    scopus 로고
    • American Association of Physicists in Medicine January 2008 Accessed January 15
    • American Association of Physicists in Medicine. The measurement, reporting, and management of radiation dose in CT; January 2008. Available at: http://www.aapm.org/pubs/reports/rpt-96.pdf. Accessed January 15, 2012.
    • (2012) The Measurement, Reporting, and Management of Radiation Dose in CT
  • 21
    • 1642389455 scopus 로고    scopus 로고
    • Low-kilovoltage multidetector row chest CT in adults: Feasibility and effect on image quality and iodine dose
    • DOI 10.1148/radiol.2311030191
    • Sigal-Cinqualbre AB, Hennequin R, Abada HT, et al. Low-kilovoltage multidetector row chest CT in adults: feasibility and effect on image quality and iodine dose. Radiology. 2004;231:169-174. (Pubitemid 38375425)
    • (2004) Radiology , vol.231 , Issue.1 , pp. 169-174
    • Sigal-Cinqualbre, A.B.1    Hennequin, R.2    Abada, H.T.3    Chen, X.4    Paul, J.-F.5
  • 22
    • 53249140708 scopus 로고    scopus 로고
    • Use of 3D adaptive raw-data filter in CTof the lung: Effect on radiation dose reduction
    • Kubo T, Ohno Y, Gautam S, et al. Use of 3D adaptive raw-data filter in CTof the lung: effect on radiation dose reduction. AJR Am J Roentgenol. 2008;191:1071.
    • (2008) AJR Am J Roentgenol , vol.191 , pp. 1071
    • Kubo, T.1    Ohno, Y.2    Gautam, S.3
  • 23
    • 70350508400 scopus 로고    scopus 로고
    • Cystic fibrosis: Are volumetric ultralow-dose expiratory CT scans sufficient for monitoring related lung disease?
    • Loeve M, Lequin MH, de Bruijne M, et al. Cystic fibrosis: are volumetric ultralow-dose expiratory CT scans sufficient for monitoring related lung disease? Radiology. 2009;253:223-229.
    • (2009) Radiology , vol.253 , pp. 223-229
    • Loeve, M.1    Lequin, M.H.2    De Bruijne, M.3
  • 24
    • 79952440432 scopus 로고    scopus 로고
    • Computed tomography of the lung in the high-pitch mode: Is breath holding still required?
    • Baumueller S, Alkadhi H, Stolzmann P, et al. Computed tomography of the lung in the high-pitch mode: is breath holding still required? Invest Radiol. 2011;46:240-245.
    • (2011) Invest Radiol , vol.46 , pp. 240-245
    • Baumueller, S.1    Alkadhi, H.2    Stolzmann, P.3
  • 25
    • 79959960464 scopus 로고    scopus 로고
    • Dose reduction in abdominal computed tomography: Intraindividual comparison of image quality of full-dose standard and half-dose iterative reconstructions with dual-source computed tomography
    • May MS, Wust W, Brand M, et al. Dose reduction in abdominal computed tomography: intraindividual comparison of image quality of full-dose standard and half-dose iterative reconstructions with dual-source computed tomography. Invest Radiol. 2011;46:465-470.
    • (2011) Invest Radiol , vol.46 , pp. 465-470
    • May, M.S.1    Wust, W.2    Brand, M.3
  • 26
    • 3042786399 scopus 로고    scopus 로고
    • Distance-driven projection and backprojection in three dimensions
    • DOI 10.1088/0031-9155/49/11/024, PII S003191550470994X, Seventh International Conference on Fully Three-Dimensional Reconstruction in Radiology and Nuclear Medicine
    • De Man B, Basu S. Distance-driven projection and backprojection in three dimensions. Phys Med Biol. 2004;49:2463-2475. (Pubitemid 38867914)
    • (2004) Physics in Medicine and Biology , vol.49 , Issue.11 , pp. 2463-2475
    • De Man, B.1    Basu, S.2
  • 28
    • 0027624429 scopus 로고
    • Generalized Gaussian image model for edge-preserving MAP estimation
    • DOI 10.1109/83.236536
    • Bouman C, Sauer K. A generalized Gaussian image model for edge-preserving MAP estimation. IEEE Trans Image Process. 1993;2:296-310. (Pubitemid 23697158)
    • (1993) IEEE Transactions on Image Processing , vol.2 , Issue.3 , pp. 296-310
    • Bouman Charles1    Sauer Ken2
  • 29
    • 77956841482 scopus 로고    scopus 로고
    • Abdominal CT: Comparison of low-dose CT with adaptive statistical iterative reconstruction and routine-dose CT with filtered back projection in 53 patients
    • Sagara Y, Hara AK, Pavlicek W, et al. Abdominal CT: comparison of low-dose CT with adaptive statistical iterative reconstruction and routine-dose CT with filtered back projection in 53 patients. AJR Am J Roentgenol. 2010;195:713-719.
    • (2010) AJR Am J Roentgenol , vol.195 , pp. 713-719
    • Sagara, Y.1    Hara, A.K.2    Pavlicek, W.3
  • 30
    • 77949865226 scopus 로고    scopus 로고
    • Reducing abdominal CT radiation dose with adaptive statistical iterative reconstruction technique
    • Prakash P, Kalra MK, Kambadakone AK, et al. Reducing abdominal CT radiation dose with adaptive statistical iterative reconstruction technique. Invest Radiol. 2010;45:202-210.
    • (2010) Invest Radiol , vol.45 , pp. 202-210
    • Prakash, P.1    Kalra, M.K.2    Kambadakone, A.K.3
  • 31
    • 80053922582 scopus 로고    scopus 로고
    • Coronary CT angiography: Image quality, diagnostic accuracy, and potential for radiation dose reduction using a novel iterative image reconstruction techniqueVcomparison with traditional filtered back projection
    • Moscariello A, Takx RA, Schoepf UJ, et al. Coronary CT angiography: image quality, diagnostic accuracy, and potential for radiation dose reduction using a novel iterative image reconstruction techniqueVcomparison with traditional filtered back projection. Eur Radiol. 2011;21:2130-2138.
    • (2011) Eur Radiol , vol.21 , pp. 2130-2138
    • Moscariello, A.1    Takx, R.A.2    Schoepf, U.J.3
  • 32
    • 80051517687 scopus 로고    scopus 로고
    • Combination of a low-tube-voltage technique with hybrid iterative reconstruction (iDose) algorithm at coronary computed tomographic angiography
    • Funama Y, Taguchi K, Utsunomiya D, et al. Combination of a low-tube-voltage technique with hybrid iterative reconstruction (iDose) algorithm at coronary computed tomographic angiography. J Comput Assist Tomogr. 2011;35:480-485.
    • (2011) J Comput Assist Tomogr , vol.35 , pp. 480-485
    • Funama, Y.1    Taguchi, K.2    Utsunomiya, D.3
  • 33
    • 84863677220 scopus 로고    scopus 로고
    • Iterative reconstruction methods in two different MDCT scanners: Physical metrics and 4-alternative forced-choice detectability experiments-A phantom approach
    • In press
    • Mieville FA, Gudinchet F, Brunelle F, et al. Iterative reconstruction methods in two different MDCT scanners: physical metrics and 4-alternative forced-choice detectability experiments-A phantom approach. Phys Med. 2012. In press.
    • (2012) Phys Med
    • Mieville, F.A.1    Gudinchet, F.2    Brunelle, F.3
  • 34
    • 84856605802 scopus 로고    scopus 로고
    • CT image quality improvement using adaptive iterative dose reduction with wide-volume acquisition on 320-detector CT
    • Gervaise A, Osemont B, Lecocq S, et al. CT image quality improvement using adaptive iterative dose reduction with wide-volume acquisition on 320-detector CT. Eur Radiol. 2012;22:295-301.
    • (2012) Eur Radiol , vol.22 , pp. 295-301
    • Gervaise, A.1    Osemont, B.2    Lecocq, S.3
  • 35
    • 0242552186 scopus 로고    scopus 로고
    • Utility of the Lateral Chest Radiograph in the Evaluation of Patients with a Positive Tuberculin Skin Test Result
    • DOI 10.1378/chest.124.5.1824
    • Meyer M, Clarke P, O'Regan AW. Utility of the lateral chest radiograph in the evaluation of patients with a positive tuberculin skin test result. Chest. 2003;124:1824-1827. (Pubitemid 37433579)
    • (2003) Chest , vol.124 , Issue.5 , pp. 1824-1827
    • Meyer, M.1    Clarke, P.2    O'Regan, A.W.3
  • 36
    • 0034554015 scopus 로고    scopus 로고
    • Radiation exposure associated with imaging of the chest: Comparison of different radiographic and computed tomography techniques
    • Diederich S, Lenzen H. Radiation exposure associated with imaging of the chest: comparison of different radiographic and computed tomography techniques. Cancer. 2000;89:2457-2460.
    • (2000) Cancer , vol.89 , pp. 2457-2460
    • Diederich, S.1    Lenzen, H.2
  • 37
    • 40049100060 scopus 로고    scopus 로고
    • An outlook on x-ray CT research and development
    • DOI 10.1118/1.2836950
    • Wang G, Yu H, De Man B. An outlook on X-ray CT research and development. Med Phys. 2008;35:1051-1064. (Pubitemid 351322651)
    • (2008) Medical Physics , vol.35 , Issue.3 , pp. 1051-1064
    • Wang, G.1    Yu, H.2    De Man, B.3
  • 38
    • 0036462553 scopus 로고    scopus 로고
    • Statistical image reconstruction for polyenergetic X-ray computed tomography
    • DOI 10.1109/42.993128, PII S0278006202029361
    • Elbakri IA, Fessler JA. Statistical image reconstruction for polyenergetic X-ray computed tomography. IEEE Trans Med Imaging. 2002;21:89-99. (Pubitemid 34466423)
    • (2002) IEEE Transactions on Medical Imaging , vol.21 , Issue.2 , pp. 89-99
    • Elbakri, I.A.1    Fessler, J.A.2
  • 39
    • 33846564402 scopus 로고    scopus 로고
    • Noise and resolution in images reconstructed with FBP and OSC algorithms for CT
    • DOI 10.1118/1.2409481
    • Ziegler A, Kohler T, Proksa R. Noise and resolution in images reconstructed with FBP and OSC algorithms for CT. Med Phys. 2007;34:585-598. (Pubitemid 46185138)
    • (2007) Medical Physics , vol.34 , Issue.2 , pp. 585-598
    • Ziegler, A.1    Kohler, Th.2    Proksa, R.3
  • 40
    • 12144261858 scopus 로고    scopus 로고
    • Detection of pulmonary nodules at multirow-detector CT: Effectiveness of double reading to improve sensitivity at standard-dose and low-dose chest CT
    • DOI 10.1007/s00330-004-2527-6
    • Wormanns D, Ludwig K, Beyer F, et al. Detection of pulmonary nodules at multirow-detector CT: effectiveness of double reading to improve sensitivity at standard-dose and low-dose chest CT. Eur Radiol. 2005;15:14-22. (Pubitemid 40109764)
    • (2005) European Radiology , vol.15 , Issue.1 , pp. 14-22
    • Wormanns, D.1    Ludwig, K.2    Beyer, F.3    Heindel, W.4    Diederich, S.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.