메뉴 건너뛰기




Volumn 23, Issue 2, 2013, Pages 360-366

Computed tomography of the chest with model-based iterative reconstruction using a radiation exposure similar to chest X-ray examination: Preliminary observations

Author keywords

Chest; Computed tomography; Low dose; Model based iterative reconstruction (MBIR); Pulmonary nodules

Indexed keywords

ADULT; AGED; ALGORITHM; ARTICLE; BRONCHIECTASIS; CLINICAL ARTICLE; COMPUTER ASSISTED TOMOGRAPHY; DIAGNOSTIC IMAGING; EMPHYSEMA; FEMALE; HUMAN; IMAGE ANALYSIS; IMAGE QUALITY; IMAGE RECONSTRUCTION; INTERMETHOD COMPARISON; MALE; NOISE; NOISE MEASUREMENT; PRIORITY JOURNAL; RADIATION DOSE; RADIATION EXPOSURE; THORAX RADIOGRAPHY;

EID: 84878598953     PISSN: 09387994     EISSN: 14321084     Source Type: Journal    
DOI: 10.1007/s00330-012-2627-7     Document Type: Article
Times cited : (182)

References (23)
  • 1
    • 36549007486 scopus 로고    scopus 로고
    • Computed tomography - An increasing source of radiation exposure
    • 18046031 10.1056/NEJMra072149 1:CAS:528:DC%2BD2sXhsVSlurfF
    • Brenner DJ, Hall EJ (2007) Computed tomography - an increasing source of radiation exposure. N Engl J Med 357:2277-2284
    • (2007) N Engl J Med , vol.357 , pp. 2277-2284
    • Brenner, D.J.1    Hall, E.J.2
  • 2
    • 2142695134 scopus 로고    scopus 로고
    • Radiation risks potentially associated with low-dose CT screening of adult smokers for lung cancer
    • 15128988 10.1148/radiol.2312030880
    • Brenner DJ (2004) Radiation risks potentially associated with low-dose CT screening of adult smokers for lung cancer. Radiology 231:440-445
    • (2004) Radiology , vol.231 , pp. 440-445
    • Brenner, D.J.1
  • 3
    • 83155193047 scopus 로고    scopus 로고
    • Comparison of image quality and radiation dose between combined automatic tube current modulation and fixed tube current technique in CT of abdomen and pelvis
    • 21903869 10.1258/ar.2011.100295
    • Lee S, Yoon SW, Yoo SM, et al. (2011) Comparison of image quality and radiation dose between combined automatic tube current modulation and fixed tube current technique in CT of abdomen and pelvis. Acta Radiol 52:1101-1106
    • (2011) Acta Radiol , vol.52 , pp. 1101-1106
    • Lee, S.1    Yoon, S.W.2    Yoo, S.M.3
  • 4
    • 78649700320 scopus 로고    scopus 로고
    • A prospective evaluation of dose reduction and image quality in chest CT using adaptive statistical iterative reconstruction
    • 20966312 10.2214/AJR.09.4050
    • Leipsic J, Nguyen G, Brown J, Sin D, Mayo JR (2010) A prospective evaluation of dose reduction and image quality in chest CT using adaptive statistical iterative reconstruction. AJR Am J Roentgenol 195:1095-1099
    • (2010) AJR Am J Roentgenol , vol.195 , pp. 1095-1099
    • Leipsic, J.1    Nguyen, G.2    Brown, J.3    Sin, D.4    Mayo, J.R.5
  • 5
    • 79751526184 scopus 로고    scopus 로고
    • Chest computed tomography using iterative reconstruction vs filtered back projection (Part 2): Image quality of low-dose CT examinations in 80 patients
    • 21080171 10.1007/s00330-010-1991-4
    • Pontana F, Duhamel A, Pagniez J, et al. (2011) Chest computed tomography using iterative reconstruction vs filtered back projection (Part 2): image quality of low-dose CT examinations in 80 patients. Eur Radiol 21:636-643
    • (2011) Eur Radiol , vol.21 , pp. 636-643
    • Pontana, F.1    Duhamel, A.2    Pagniez, J.3
  • 6
    • 79751534189 scopus 로고    scopus 로고
    • Chest computed tomography using iterative reconstruction vs filtered back projection (Part 1): Evaluation of image noise reduction in 32 patients
    • 21053003 10.1007/s00330-010-1990-5
    • Pontana F, Pagniez J, Flohr T, et al. (2011) Chest computed tomography using iterative reconstruction vs filtered back projection (Part 1): evaluation of image noise reduction in 32 patients. Eur Radiol 21:627-635
    • (2011) Eur Radiol , vol.21 , pp. 627-635
    • Pontana, F.1    Pagniez, J.2    Flohr, T.3
  • 7
    • 76449091107 scopus 로고    scopus 로고
    • Radiation dose reduction with chest computed tomography using adaptive statistical iterative reconstruction technique: Initial experience
    • 20118720 10.1097/RCT.0b013e3181b26c67
    • Prakash P, Kalra MK, Digumarthy SR, et al. (2010) Radiation dose reduction with chest computed tomography using adaptive statistical iterative reconstruction technique: initial experience. J Comput Assist Tomogr 34:40-45
    • (2010) J Comput Assist Tomogr , vol.34 , pp. 40-45
    • Prakash, P.1    Kalra, M.K.2    Digumarthy, S.R.3
  • 8
    • 84878566197 scopus 로고    scopus 로고
    • Effect of radiation dose and adaptive statistical iterative reconstruction on image quality of pulmonary computed tomography
    • Sato J, Akahane M, Inano S, et al. (2011) Effect of radiation dose and adaptive statistical iterative reconstruction on image quality of pulmonary computed tomography. Jpn J Radiol
    • (2011) Jpn J Radiol
    • Sato, J.1    Akahane, M.2    Inano, S.3
  • 9
    • 79955036642 scopus 로고    scopus 로고
    • Adaptive statistical iterative reconstruction technique for radiation dose reduction in chest CT: A pilot study
    • 21386048 10.1148/radiol.11101450
    • Singh S, Kalra MK, Gilman MD, et al. (2011) Adaptive statistical iterative reconstruction technique for radiation dose reduction in chest CT: a pilot study. Radiology 259:565-573
    • (2011) Radiology , vol.259 , pp. 565-573
    • Singh, S.1    Kalra, M.K.2    Gilman, M.D.3
  • 10
    • 84856974997 scopus 로고    scopus 로고
    • Coronary artery plaques: Cardiac CT with model-based and adaptive-statistical iterative reconstruction technique
    • Scheffel H, Stolzmann P, Schlett CL, et al. (2011) Coronary artery plaques: Cardiac CT with model-based and adaptive-statistical iterative reconstruction technique. Eur J Radiol
    • (2011) Eur J Radiol
    • Scheffel, H.1    Stolzmann, P.2    Schlett, C.L.3
  • 11
    • 33847233255 scopus 로고    scopus 로고
    • Air trapping: Comparison of standard-dose and simulated low-dose thin-section CT techniques
    • 17244721 10.1148/radiol.2423060196
    • Bankier AA, Schaefer-Prokop C, De Maertelaer V, et al. (2007) Air trapping: comparison of standard-dose and simulated low-dose thin-section CT techniques. Radiology 242:898-906
    • (2007) Radiology , vol.242 , pp. 898-906
    • Bankier, A.A.1    Schaefer-Prokop, C.2    De Maertelaer, V.3
  • 12
    • 79952337769 scopus 로고    scopus 로고
    • Comparison of low dose and standard dose MDCT in detection of metastatic pulmonary nodules
    • 21534369
    • Muangman N, Maitreesorrasan N, Totanarungroj K (2011) Comparison of low dose and standard dose MDCT in detection of metastatic pulmonary nodules. J Med Assoc Thai 94:215-223
    • (2011) J Med Assoc Thai , vol.94 , pp. 215-223
    • Muangman, N.1    Maitreesorrasan, N.2    Totanarungroj, K.3
  • 14
    • 79952181279 scopus 로고    scopus 로고
    • CT effective dose per dose length product using ICRP 103 weighting factors
    • 21520838 10.1118/1.3544350
    • Huda W, Magill D, He W (2011) CT effective dose per dose length product using ICRP 103 weighting factors. Med Phys 38:1261-1265
    • (2011) Med Phys , vol.38 , pp. 1261-1265
    • Huda, W.1    Magill, D.2    He, W.3
  • 15
    • 84873281232 scopus 로고    scopus 로고
    • Why do commercial CT scanners still employ traditional, filtered back-projection for image reconstruction?
    • 20376330 10.1088/0266-5611/25/12/123009
    • Pan X, Sidky EY, Vannier M (2009) Why do commercial CT scanners still employ traditional, filtered back-projection for image reconstruction? Inverse Probl 25:1230009
    • (2009) Inverse Probl , vol.25 , pp. 1230009
    • Pan, X.1    Sidky, E.Y.2    Vannier, M.3
  • 16
    • 84864713607 scopus 로고    scopus 로고
    • Model-based iterative reconstruction technique for radiation dose reduction in chest CT: Comparison with the adaptive statistical iterative reconstruction technique
    • Katsura M, Matsuda I, Akahane M, et al. (2012) Model-based iterative reconstruction technique for radiation dose reduction in chest CT: comparison with the adaptive statistical iterative reconstruction technique. Eur Radiol 22:1613-1623
    • (2012) Eur Radiol , vol.22 , pp. 1613-1623
    • Katsura, M.1    Matsuda, I.2    Akahane, M.3
  • 17
    • 0141855190 scopus 로고    scopus 로고
    • Dose reduction in patients undergoing chest imaging: Digital amorphous silicon flat-panel detector radiography versus conventional film-screen radiography and phosphor-based computed radiography
    • 14500203
    • Bacher K, Smeets P, Bonnarens K, De Hauwere A, Verstraete K, Thierens H (2003) Dose reduction in patients undergoing chest imaging: digital amorphous silicon flat-panel detector radiography versus conventional film-screen radiography and phosphor-based computed radiography. AJR Am J Roentgenol 181:923-929
    • (2003) AJR Am J Roentgenol , vol.181 , pp. 923-929
    • Bacher, K.1    Smeets, P.2    Bonnarens, K.3    De Hauwere, A.4    Verstraete, K.5    Thierens, H.6
  • 18
    • 47249166093 scopus 로고    scopus 로고
    • Effective doses in radiology and diagnostic nuclear medicine: A catalog
    • 18566177 10.1148/radiol.2481071451
    • Mettler FA Jr, Huda W, Yoshizumi TT, Mahesh M (2008) Effective doses in radiology and diagnostic nuclear medicine: a catalog. Radiology 248:254-263
    • (2008) Radiology , vol.248 , pp. 254-263
    • Mettler, Jr.F.A.1    Huda, W.2    Yoshizumi, T.T.3    Mahesh, M.4
  • 19
    • 84864652883 scopus 로고    scopus 로고
    • Analysis of the impact of digital tomosynthesis on the radiological investigation of patients with suspected pulmonary lesions on chest radiography
    • doi: 10.1007/s00330-012-2440-3
    • Quaia E, Baratella E, Cernic S, et al. (2012) Analysis of the impact of digital tomosynthesis on the radiological investigation of patients with suspected pulmonary lesions on chest radiography. Eur Radiol. doi: 10.1007/s00330-012-2440-3
    • (2012) Eur Radiol.
    • Quaia, E.1    Baratella, E.2    Cernic, S.3
  • 20
    • 84856888168 scopus 로고    scopus 로고
    • Exposure of the Swiss population by medical x-rays: 2008 review
    • 22420018 1:CAS:528:DC%2BC38Xit1SlsLc%3D
    • Samara ET, Aroua A, Bochud FO, et al. (2012) Exposure of the Swiss population by medical x-rays: 2008 review. Health Phys 102:263-270
    • (2012) Health Phys , vol.102 , pp. 263-270
    • Samara, E.T.1    Aroua, A.2    Bochud, F.O.3
  • 21
    • 21244434852 scopus 로고    scopus 로고
    • Retrospective patient dose analysis of a digital radiography system in routine clinical use
    • 15933094 10.1093/rpd/nch535
    • Schuncke A, Neitzel U (2005) Retrospective patient dose analysis of a digital radiography system in routine clinical use. Radiat Prot Dosimetry 114:131-134
    • (2005) Radiat Prot Dosimetry , vol.114 , pp. 131-134
    • Schuncke, A.1    Neitzel, U.2
  • 22
    • 84858796991 scopus 로고    scopus 로고
    • CT screening for lung cancer brings forward early disease. The randomised Danish Lung Cancer Screening Trial: Status after five annual screening rounds with low-dose CT
    • 22286927 10.1136/thoraxjnl-2011-200736
    • Saghir Z, Dirksen A, Ashraf H, et al. (2012) CT screening for lung cancer brings forward early disease. The randomised Danish Lung Cancer Screening Trial: status after five annual screening rounds with low-dose CT. Thorax 67:296-301
    • (2012) Thorax , vol.67 , pp. 296-301
    • Saghir, Z.1    Dirksen, A.2    Ashraf, H.3
  • 23
    • 79551517886 scopus 로고    scopus 로고
    • Fast model-based X-ray CT reconstruction using spatially nonhomogeneous ICD optimization
    • 20643609 10.1109/TIP.2010.2058811
    • Yu Z, Thibault JB, Bouman CA, Sauer KD, Hsieh J (2011) Fast model-based X-ray CT reconstruction using spatially nonhomogeneous ICD optimization. IEEE Trans Image Process 20:161-175
    • (2011) IEEE Trans Image Process , vol.20 , pp. 161-175
    • Yu, Z.1    Thibault, J.B.2    Bouman, C.A.3    Sauer, K.D.4    Hsieh, J.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.