메뉴 건너뛰기




Volumn 43, Issue 4, 2012, Pages 228-238

Image quality assessment in torso phantom comparing effects of varying automatic current modulation with filtered back projection, adaptive statistical, and model-based iterative reconstruction techniques in CT

Author keywords

[No Author keywords available]

Indexed keywords

ADAPTIVE STATISTICAL ITERATIVE RECONSTRUCTION; ALGORITHM; AMPLITUDE MODULATION; ARTICLE; COMPUTER ASSISTED TOMOGRAPHY; CONTROLLED STUDY; DIGITAL FILTERING; DOSE RESPONSE; FILTERED BACK PROJECTION; IMAGE ANALYSIS; IMAGE QUALITY; IMAGE RECONSTRUCTION; INTERMETHOD COMPARISON; MODEL BASED ITERATIVE RECONSTRUCTION; NOISE REDUCTION; PRIORITY JOURNAL; QUALITY CONTROL; SIGNAL NOISE RATIO; STATISTICAL MODEL; TRUNK;

EID: 84870516674     PISSN: 19398654     EISSN: 18767982     Source Type: Journal    
DOI: 10.1016/j.jmir.2012.09.006     Document Type: Article
Times cited : (7)

References (24)
  • 1
    • 77949419896 scopus 로고    scopus 로고
    • Radiologic and nuclear medicine studies in the United States and worldwide: Frequency, radiation dose, and comparison with other radiation sources - 1950-2007
    • F.A. Mettler, M. Bhargavan, K. Faulkner, D.B. Gilley, J.E. Gray, and G.S. Ibbott Radiologic and nuclear medicine studies in the United States and worldwide: frequency, radiation dose, and comparison with other radiation sources - 1950-2007 Radiology 253 2009 520 531
    • (2009) Radiology , vol.253 , pp. 520-531
    • Mettler, F.A.1    Bhargavan, M.2    Faulkner, K.3    Gilley, D.B.4    Gray, J.E.5    Ibbott, G.S.6
  • 5
    • 84872429969 scopus 로고    scopus 로고
    • US Food and Drug Administration Accessed December 12, 2011
    • US Food and Drug Administration. FDA 510(k) premarket notification. Available from: http://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfPMN/pmn.cfm? ID=35628. Accessed December 12, 2011.
    • FDA 510(k) Premarket Notification
  • 6
    • 77956841482 scopus 로고    scopus 로고
    • Abdominal CT: Comparison of low-dose CT with adaptive statistical iterative reconstruction and routine-dose CT with filtered back projection in 53 patients
    • Y. Sagara, A.K. Hara, W. Pavlicek, A.C. Silva, R.G. Paden, and Q. Wu Abdominal CT: comparison of low-dose CT with adaptive statistical iterative reconstruction and routine-dose CT with filtered back projection in 53 patients AJR Am J Roentgenol 195 2010 713 719
    • (2010) AJR Am J Roentgenol , vol.195 , pp. 713-719
    • Sagara, Y.1    Hara, A.K.2    Pavlicek, W.3    Silva, A.C.4    Paden, R.G.5    Wu, Q.6
  • 7
    • 79751526184 scopus 로고    scopus 로고
    • Chest computed tomography using iterative reconstruction vs filtered back projection (part 2): Image quality of low-dose CT examinations in 80 patients
    • F. Pontana, A. Duhamel, J. Pagniez, T. Flohr, J.-B. Faivre, and A.-L. Hachulla Chest computed tomography using iterative reconstruction vs filtered back projection (part 2): image quality of low-dose CT examinations in 80 patients Eur Radiol 21 2010 636 643
    • (2010) Eur Radiol , vol.21 , pp. 636-643
    • Pontana, F.1    Duhamel, A.2    Pagniez, J.3    Flohr, T.4    Faivre, J.-B.5    Hachulla, A.-L.6
  • 8
    • 78249261294 scopus 로고    scopus 로고
    • Image quality and radiation exposure with a low tube voltage protocol for coronary CT angiography results of the PROTECTION II Trial
    • J. Hausleiter, S. Martinoff, M. Hadamitzky, E. Martuscelli, I. Pschierer, and G.M. Feuchtner Image quality and radiation exposure with a low tube voltage protocol for coronary CT angiography results of the PROTECTION II Trial JACC Cardiovasc Imaging 3 2010 1113 1123
    • (2010) JACC Cardiovasc Imaging , vol.3 , pp. 1113-1123
    • Hausleiter, J.1    Martinoff, S.2    Hadamitzky, M.3    Martuscelli, E.4    Pschierer, I.5    Feuchtner, G.M.6
  • 9
    • 75349092506 scopus 로고    scopus 로고
    • Low-tube-voltage, high-tube-current multidetector abdominal CT: Improved image quality and decreased radiation dose with adaptive statistical iterative reconstruction algorithm - Initial clinical experience
    • D. Marin, R.C. Nelson, S.T. Schindera, S. Richard, R.S. Youngblood, and T.T. Yoshizumi Low-tube-voltage, high-tube-current multidetector abdominal CT: improved image quality and decreased radiation dose with adaptive statistical iterative reconstruction algorithm - initial clinical experience Radiology 254 2010 145 153
    • (2010) Radiology , vol.254 , pp. 145-153
    • Marin, D.1    Nelson, R.C.2    Schindera, S.T.3    Richard, S.4    Youngblood, R.S.5    Yoshizumi, T.T.6
  • 10
    • 78649674600 scopus 로고    scopus 로고
    • Development of low-dose protocols for thin-section CT assessment of cystic fibrosis in pediatric patients
    • O.J. O'Connor, M. Vandeleur, A.M. McGarrigle, N. Moore, S.R. McWilliams, and S.E. McSweeney Development of low-dose protocols for thin-section CT assessment of cystic fibrosis in pediatric patients Radiology 257 2010 820 829
    • (2010) Radiology , vol.257 , pp. 820-829
    • O'Connor, O.J.1    Vandeleur, M.2    McGarrigle, A.M.3    Moore, N.4    McWilliams, S.R.5    McSweeney, S.E.6
  • 11
    • 73449113287 scopus 로고    scopus 로고
    • Method for automatic tube current selection for obtaining a consistent image quality and dose optimization in a cardiac multidetector CT
    • W. Qi, J. Li, and X. Du Method for automatic tube current selection for obtaining a consistent image quality and dose optimization in a cardiac multidetector CT Korean J Radiol 10 2009 568
    • (2009) Korean J Radiol , vol.10 , pp. 568
    • Qi, W.1    Li, J.2    Du, X.3
  • 12
    • 84255202174 scopus 로고    scopus 로고
    • A review of patient dose and optimisation methods in adult and paediatric CT scanning
    • E. Dougeni, K. Faulkner, and G. Panayiotakis A review of patient dose and optimisation methods in adult and paediatric CT scanning Eur J Radiol 81 2012 e665 e683
    • (2012) Eur J Radiol , vol.81
    • Dougeni, E.1    Faulkner, K.2    Panayiotakis, G.3
  • 13
    • 3242815478 scopus 로고    scopus 로고
    • CT colonography: Feasibility of substantial dose reduction - Comparison of medium to very low doses in identical patients
    • R.E. van Gelder, H.W. Venema, J. Florie, C.Y. Nio, I.W.O. Serlie, and M.P. Schutter CT colonography: feasibility of substantial dose reduction - comparison of medium to very low doses in identical patients Radiology 232 2004 611 620
    • (2004) Radiology , vol.232 , pp. 611-620
    • Van Gelder, R.E.1    Venema, H.W.2    Florie, J.3    Nio, C.Y.4    Serlie, I.W.O.5    Schutter, M.P.6
  • 14
    • 77954708865 scopus 로고    scopus 로고
    • Reducing the radiation dose for CT colonography using adaptive statistical iterative reconstruction: A pilot study
    • K.T. Flicek, A.K. Hara, A.C. Silva, Q. Wu, M.B. Peter, and C.D. Johnson Reducing the radiation dose for CT colonography using adaptive statistical iterative reconstruction: a pilot study AJR Am J Roentgenol 195 2010 126 131
    • (2010) AJR Am J Roentgenol , vol.195 , pp. 126-131
    • Flicek, K.T.1    Hara, A.K.2    Silva, A.C.3    Wu, Q.4    Peter, M.B.5    Johnson, C.D.6
  • 15
    • 21244473081 scopus 로고    scopus 로고
    • A framework for optimising the radiographic technique in digital X-ray imaging
    • E. Samei A framework for optimising the radiographic technique in digital X-ray imaging Radiat Protect Dosim 114 2005 220 229
    • (2005) Radiat Protect Dosim , vol.114 , pp. 220-229
    • Samei, E.1
  • 18
    • 67650077358 scopus 로고    scopus 로고
    • Dose reduction and compliance with pediatric CT protocols adapted to patient size, clinical indication, and number of prior studies
    • S. Singh, M.K. Kalra, M.A. Moore, R. Shailam, B. Liu, and T.L. Toth Dose reduction and compliance with pediatric CT protocols adapted to patient size, clinical indication, and number of prior studies Radiology 252 2009 200 208
    • (2009) Radiology , vol.252 , pp. 200-208
    • Singh, S.1    Kalra, M.K.2    Moore, M.A.3    Shailam, R.4    Liu, B.5    Toth, T.L.6
  • 19
    • 79953310158 scopus 로고    scopus 로고
    • Adaptive statistical iterative reconstruction for volume-rendered computed tomography portovenography: Improvement of image quality
    • I. Matsuda, S. Hanaoka, M. Akahane, J. Sato, S. Komatsu, and S. Inoh Adaptive statistical iterative reconstruction for volume-rendered computed tomography portovenography: improvement of image quality Jpn J Radiol 28 2010 700 706
    • (2010) Jpn J Radiol , vol.28 , pp. 700-706
    • Matsuda, I.1    Hanaoka, S.2    Akahane, M.3    Sato, J.4    Komatsu, S.5    Inoh, S.6
  • 20
    • 77956490090 scopus 로고    scopus 로고
    • Adaptive statistical iterative reconstruction technique for pulmonary CT: Image quality of the cadaveric lung on standard- and reduced-dose CT
    • M. Yanagawa, O. Honda, S. Yoshida, A. Kikuyama, A. Inoue, and H. Sumikawa Adaptive statistical iterative reconstruction technique for pulmonary CT: image quality of the cadaveric lung on standard- and reduced-dose CT Acad Radiol 17 2010 1259 1266
    • (2010) Acad Radiol , vol.17 , pp. 1259-1266
    • Yanagawa, M.1    Honda, O.2    Yoshida, S.3    Kikuyama, A.4    Inoue, A.5    Sumikawa, H.6
  • 21
    • 84871759658 scopus 로고    scopus 로고
    • Iterative reconstruction methods in two different MDCT scanners: Physical metrics and 4-alternative forced-choice detectability experiments - A phantom approach
    • In Press
    • F.A. Miéville, F. Gudinchet, F. Brunelle, F.O. Bochud, and F.R. Verdun Iterative reconstruction methods in two different MDCT scanners: physical metrics and 4-alternative forced-choice detectability experiments - a phantom approach Phys Med 2012 In Press
    • (2012) Phys Med
    • Miéville, F.A.1    Gudinchet, F.2    Brunelle, F.3    Bochud, F.O.4    Verdun, F.R.5
  • 22
    • 77956832667 scopus 로고    scopus 로고
    • Estimated Radiation Dose Reduction using Adaptive Statistical Iterative Reconstruction in coronary CT angiography: The ERASIR Study
    • J. Leipsic, T.M. LaBounty, B. Heilbron, J.K. Min, G.B.J. Mancini, and F.Y. Lin Estimated Radiation Dose Reduction using Adaptive Statistical Iterative Reconstruction in coronary CT angiography: the ERASIR Study AJR Am J Roentgenol 195 2010 655 660
    • (2010) AJR Am J Roentgenol , vol.195 , pp. 655-660
    • Leipsic, J.1    Labounty, T.M.2    Heilbron, B.3    Min, J.K.4    Mancini, G.B.J.5    Lin, F.Y.6
  • 23
    • 84878575339 scopus 로고    scopus 로고
    • Computed tomography of the chest with model-based iterative reconstruction using a radiation exposure similar to chest X-ray examination: Preliminary observations
    • Aug 15. [Epub ahead of print]
    • A. Neroladaki, D. Botsikas, S. Boudabbous, C.D. Becker, and X. Montet Computed tomography of the chest with model-based iterative reconstruction using a radiation exposure similar to chest X-ray examination: preliminary observations Eur Radiol 2012 Aug 15. [Epub ahead of print]
    • (2012) Eur Radiol
    • Neroladaki, A.1    Botsikas, D.2    Boudabbous, S.3    Becker, C.D.4    Montet, X.5
  • 24
    • 84861487196 scopus 로고    scopus 로고
    • Comparison of hybrid and pure iterative reconstruction techniques with conventional filtered back projection: Dose reduction potential in the abdomen
    • S. Singh, M.K. Kalra, S. Do, J.B. Thibault, H. Pien, and O.O.J. Connor Comparison of hybrid and pure iterative reconstruction techniques with conventional filtered back projection: dose reduction potential in the abdomen J Comput Assist Tomogr 36 2012 347 353.
    • (2012) J Comput Assist Tomogr , vol.36 , pp. 347-353
    • Singh, S.1    Kalra, M.K.2    Do, S.3    Thibault, J.B.4    Pien, H.5    Connor, O.O.J.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.