메뉴 건너뛰기




Volumn 27, Issue 2, 2013, Pages 187-200

Monitoring cardiac function: Echocardiography, pulse contour analysis and beyond

Author keywords

cardiac function; cardiac output; echocardiography; haemodynamic monitoring; optimisation; pulse contour analysis; stroke volume

Indexed keywords

ARTERIAL PRESSURE; ARTICLE; CLINICAL ASSESSMENT TOOL; HEART FUNCTION; HEART OUTPUT; HEART STROKE VOLUME; HUMAN; KNOWLEDGE; MORTALITY; PATIENT MONITORING; PRIORITY JOURNAL; TRANSESOPHAGEAL ECHOCARDIOGRAPHY; TRANSPULMONARY THERMODILUTION; TRANSTHORACIC ECHOCARDIOGRAPHY;

EID: 84884140201     PISSN: 15216896     EISSN: 1532169X     Source Type: Journal    
DOI: 10.1016/j.bpa.2013.06.005     Document Type: Review
Times cited : (5)

References (72)
  • 1
    • 80051578300 scopus 로고    scopus 로고
    • Hemodynamic monitoring and management in patients undergoing high risk surgery: A survey among North American and European anesthesiologists
    • M. Cannesson, G. Pestel, and C. Ricks Hemodynamic monitoring and management in patients undergoing high risk surgery: a survey among North American and European anesthesiologists Crit Care 15 4 2011 R197
    • (2011) Crit Care , vol.15 , Issue.4 , pp. 197
    • Cannesson, M.1    Pestel, G.2    Ricks, C.3
  • 2
    • 0036342470 scopus 로고    scopus 로고
    • Meta-analysis of hemodynamic optimization in high-risk patients
    • J.W. Kern, and W.C. Shoemaker Meta-analysis of hemodynamic optimization in high-risk patients Crit Care Med 30 8 2002 1686 1692
    • (2002) Crit Care Med , vol.30 , Issue.8 , pp. 1686-1692
    • Kern, J.W.1    Shoemaker, W.C.2
  • 3
    • 79958110885 scopus 로고    scopus 로고
    • A systematic review and meta-analysis on the use of preemptive hemodynamic intervention to improve postoperative outcomes in moderate and high-risk surgical patients
    • M.A. Hamilton, M. Cecconi, and A. Rhodes A systematic review and meta-analysis on the use of preemptive hemodynamic intervention to improve postoperative outcomes in moderate and high-risk surgical patients Anesth Analg 112 6 2011 1392 1402
    • (2011) Anesth Analg , vol.112 , Issue.6 , pp. 1392-1402
    • Hamilton, M.A.1    Cecconi, M.2    Rhodes, A.3
  • 4
    • 79958113679 scopus 로고    scopus 로고
    • Maintaining tissue perfusion in high-risk surgical patients: A systematic review of randomized clinical trials
    • S.T. Gurgel, and P. do Nascimento Jr. Maintaining tissue perfusion in high-risk surgical patients: a systematic review of randomized clinical trials Anesth Analg 112 6 2011 1384 1391
    • (2011) Anesth Analg , vol.112 , Issue.6 , pp. 1384-1391
    • Gurgel, S.T.1    Do Nascimento, Jr.P.2
  • 5
    • 74949092815 scopus 로고    scopus 로고
    • Goal-directed haemodynamic therapy and gastrointestinal complications in major surgery: A meta-analysis of randomized controlled trials
    • M.T. Giglio, M. Marucci, and M. Testini Goal-directed haemodynamic therapy and gastrointestinal complications in major surgery: a meta-analysis of randomized controlled trials Br J Anaesth 103 5 2009 637 646
    • (2009) Br J Anaesth , vol.103 , Issue.5 , pp. 637-646
    • Giglio, M.T.1    Marucci, M.2    Testini, M.3
  • 6
    • 80052083566 scopus 로고    scopus 로고
    • Haemodynamic goal-directed therapy and postoperative infections: Earlier is better. A systematic review and meta-analysis
    • L. Dalfino, M.T. Giglio, and F. Puntillo Haemodynamic goal-directed therapy and postoperative infections: earlier is better. A systematic review and meta-analysis Crit Care 15 3 2011 R154
    • (2011) Crit Care , vol.15 , Issue.3 , pp. 154
    • Dalfino, L.1    Giglio, M.T.2    Puntillo, F.3
  • 7
    • 0020682945 scopus 로고
    • Evaluation of right-heart catheterization in the critically ill patient without acute myocardial infarction
    • A.F. Connors Jr., D.R. McCaffree, and B.A. Gray Evaluation of right-heart catheterization in the critically ill patient without acute myocardial infarction N Engl J Med 308 5 1983 263 267
    • (1983) N Engl J Med , vol.308 , Issue.5 , pp. 263-267
    • Connors, Jr.A.F.1    McCaffree, D.R.2    Gray, B.A.3
  • 8
    • 0025825991 scopus 로고
    • Therapeutic impact of pulmonary artery catheterization in a medical/surgical ICU
    • J.S. Steingrub, G. Celoria, and M. Vickers-Lahti Therapeutic impact of pulmonary artery catheterization in a medical/surgical ICU Chest 99 6 1991 1451 1455
    • (1991) Chest , vol.99 , Issue.6 , pp. 1451-1455
    • Steingrub, J.S.1    Celoria, G.2    Vickers-Lahti, M.3
  • 9
    • 84874029064 scopus 로고    scopus 로고
    • Goal-directed fluid therapy- A survey of anaesthetists in the UK, USA, Australia and New Zealand
    • S. Srinivasa, A. Kahokehr, and M. Soop Goal-directed fluid therapy- a survey of anaesthetists in the UK, USA, Australia and New Zealand BMC Anesthesiol 13 1 2013 5
    • (2013) BMC Anesthesiol , vol.13 , Issue.1 , pp. 5
    • Srinivasa, S.1    Kahokehr, A.2    Soop, M.3
  • 10
    • 84866510395 scopus 로고    scopus 로고
    • Mortality after surgery in Europe: A 7 day cohort study
    • R.M. Pearse, R.P. Moreno, and P. Bauer Mortality after surgery in Europe: a 7 day cohort study Lancet 380 9847 2012 1059 1065
    • (2012) Lancet , vol.380 , Issue.9847 , pp. 1059-1065
    • Pearse, R.M.1    Moreno, R.P.2    Bauer, P.3
  • 11
    • 31744438011 scopus 로고    scopus 로고
    • Functional hemodynamic monitoring
    • M.R. Pinsky, and D. Payen Functional hemodynamic monitoring Crit Care 9 6 2005 566 572
    • (2005) Crit Care , vol.9 , Issue.6 , pp. 566-572
    • Pinsky, M.R.1    Payen, D.2
  • 12
    • 77949305811 scopus 로고    scopus 로고
    • Cardiac output monitoring using indicator-dilution techniques: Basics, limits, and perspectives
    • D.A. Reuter, C. Huang, and T. Edrich Cardiac output monitoring using indicator-dilution techniques: basics, limits, and perspectives Anesth Analg 110 3 2010 799 811
    • (2010) Anesth Analg , vol.110 , Issue.3 , pp. 799-811
    • Reuter, D.A.1    Huang, C.2    Edrich, T.3
  • 13
    • 79955631501 scopus 로고    scopus 로고
    • Pulmonary artery catheter monitoring in 2011
    • C. Richard, X. Monnet, and J.L. Teboul Pulmonary artery catheter monitoring in 2011 Curr Opin Crit Care 17 3 2011 296 302
    • (2011) Curr Opin Crit Care , vol.17 , Issue.3 , pp. 296-302
    • Richard, C.1    Monnet, X.2    Teboul, J.L.3
  • 14
    • 59649127189 scopus 로고    scopus 로고
    • Comparison of pulmonary artery and aortic transpulmonary thermodilution for monitoring of cardiac output in patients with severe heart failure: Validation of a novel method
    • S. Friesecke, A. Heinrich, and P. Abel Comparison of pulmonary artery and aortic transpulmonary thermodilution for monitoring of cardiac output in patients with severe heart failure: validation of a novel method Crit Care Med 37 1 2009 119 123
    • (2009) Crit Care Med , vol.37 , Issue.1 , pp. 119-123
    • Friesecke, S.1    Heinrich, A.2    Abel, P.3
  • 15
    • 0032847442 scopus 로고    scopus 로고
    • Comparison of pulmonary artery and arterial thermodilution cardiac output in critically ill patients
    • S.G. Sakka, K. Reinhart, and A. Meier-Hellmann Comparison of pulmonary artery and arterial thermodilution cardiac output in critically ill patients Intensive Care Med 25 8 1999 843 846
    • (1999) Intensive Care Med , vol.25 , Issue.8 , pp. 843-846
    • Sakka, S.G.1    Reinhart, K.2    Meier-Hellmann, A.3
  • 16
    • 84868379180 scopus 로고    scopus 로고
    • The transpulmonary thermodilution technique
    • S.G. Sakka, D.A. Reuter, and A. Perel The transpulmonary thermodilution technique J Clin Monit Comput 26 5 2012 347 353
    • (2012) J Clin Monit Comput , vol.26 , Issue.5 , pp. 347-353
    • Sakka, S.G.1    Reuter, D.A.2    Perel, A.3
  • 17
    • 0035987571 scopus 로고    scopus 로고
    • Transpulmonary thermodilution cardiac output measurement using the axillary artery in critically ill patients
    • E. Segal, R. Katzenelson, and H. Berkenstadt Transpulmonary thermodilution cardiac output measurement using the axillary artery in critically ill patients J Clin Anesth 14 3 2002 210 213
    • (2002) J Clin Anesth , vol.14 , Issue.3 , pp. 210-213
    • Segal, E.1    Katzenelson, R.2    Berkenstadt, H.3
  • 18
    • 0036020297 scopus 로고    scopus 로고
    • Cardiac output determination in children: Equivalence of the transpulmonary thermodilution method to the direct Fick principle
    • C. Pauli, U. Fakler, and T. Genz Cardiac output determination in children: equivalence of the transpulmonary thermodilution method to the direct Fick principle Intensive Care Med 28 7 2002 947 952
    • (2002) Intensive Care Med , vol.28 , Issue.7 , pp. 947-952
    • Pauli, C.1    Fakler, U.2    Genz, T.3
  • 19
    • 84055182994 scopus 로고    scopus 로고
    • Prediction of fluid responsiveness in infants and neonates undergoing congenital heart surgery
    • J. Renner, O. Broch, and P. Duetschke Prediction of fluid responsiveness in infants and neonates undergoing congenital heart surgery Br J Anaesth 108 1 2012 108 115
    • (2012) Br J Anaesth , vol.108 , Issue.1 , pp. 108-115
    • Renner, J.1    Broch, O.2    Duetschke, P.3
  • 20
    • 0036793048 scopus 로고    scopus 로고
    • Assessment of cardiac output, intravascular volume status, and extravascular lung water by transpulmonary indicator dilution in critically ill neonates and infants
    • H. Schiffmann, B. Erdlenbruch, and D. Singer Assessment of cardiac output, intravascular volume status, and extravascular lung water by transpulmonary indicator dilution in critically ill neonates and infants J Cardiothorac Vasc Anesth 16 5 2002 592 597
    • (2002) J Cardiothorac Vasc Anesth , vol.16 , Issue.5 , pp. 592-597
    • Schiffmann, H.1    Erdlenbruch, B.2    Singer, D.3
  • 21
    • 0028334544 scopus 로고
    • Bedside assessment of intravascular volume status in patients undergoing coronary bypass surgery
    • A. Hoeft, B. Schorn, and A. Weyland Bedside assessment of intravascular volume status in patients undergoing coronary bypass surgery Anesthesiology 81 1 1994 76 86
    • (1994) Anesthesiology , vol.81 , Issue.1 , pp. 76-86
    • Hoeft, A.1    Schorn, B.2    Weyland, A.3
  • 22
    • 73449127209 scopus 로고    scopus 로고
    • Cardiac function index provided by transpulmonary thermodilution behaves as an indicator of left ventricular systolic function
    • J. Jabot, X. Monnet, and L. Bouchra Cardiac function index provided by transpulmonary thermodilution behaves as an indicator of left ventricular systolic function Crit Care Med 37 11 2009 2913 2918
    • (2009) Crit Care Med , vol.37 , Issue.11 , pp. 2913-2918
    • Jabot, J.1    Monnet, X.2    Bouchra, L.3
  • 23
    • 0033001658 scopus 로고    scopus 로고
    • Comparison between intrathoracic blood volume and cardiac filling pressures in the early phase of hemodynamic instability of patients with sepsis or septic shock
    • S.G. Sakka, D.L. Bredle, and K. Reinhart Comparison between intrathoracic blood volume and cardiac filling pressures in the early phase of hemodynamic instability of patients with sepsis or septic shock J Crit Care 14 2 1999 78 83
    • (1999) J Crit Care , vol.14 , Issue.2 , pp. 78-83
    • Sakka, S.G.1    Bredle, D.L.2    Reinhart, K.3
  • 24
    • 0034027184 scopus 로고    scopus 로고
    • Assessment of cardiac preload and extravascular lung water by single transpulmonary thermodilution
    • S.G. Sakka, C.C. Ruhl, and U.J. Pfeiffer Assessment of cardiac preload and extravascular lung water by single transpulmonary thermodilution Intensive Care Med 26 2 2000 180 187
    • (2000) Intensive Care Med , vol.26 , Issue.2 , pp. 180-187
    • Sakka, S.G.1    Ruhl, C.C.2    Pfeiffer, U.J.3
  • 25
    • 78549250767 scopus 로고    scopus 로고
    • Validation of a new transpulmonary thermodilution system to assess global end-diastolic volume and extravascular lung water
    • K. Bendjelid, R. Giraud, and N. Siegenthaler Validation of a new transpulmonary thermodilution system to assess global end-diastolic volume and extravascular lung water Crit Care 14 6 2010 R209
    • (2010) Crit Care , vol.14 , Issue.6 , pp. 209
    • Bendjelid, K.1    Giraud, R.2    Siegenthaler, N.3
  • 26
    • 84859800640 scopus 로고    scopus 로고
    • Variation of left ventricular outflow tract velocity and global end-diastolic volume index reliably predict fluid responsiveness in cardiac surgery patients
    • 325 e7-e13
    • O. Broch, J. Renner, and M. Gruenewald Variation of left ventricular outflow tract velocity and global end-diastolic volume index reliably predict fluid responsiveness in cardiac surgery patients J Crit Care 27 3 2012 325 e7-e13
    • (2012) J Crit Care , vol.27 , Issue.3
    • Broch, O.1    Renner, J.2    Gruenewald, M.3
  • 27
    • 0242468625 scopus 로고    scopus 로고
    • Global end-diastolic volume as an indicator of cardiac preload in patients with septic shock
    • F. Michard, S. Alaya, and V. Zarka Global end-diastolic volume as an indicator of cardiac preload in patients with septic shock Chest 124 5 2003 1900 1908
    • (2003) Chest , vol.124 , Issue.5 , pp. 1900-1908
    • Michard, F.1    Alaya, S.2    Zarka, V.3
  • 28
    • 33748116524 scopus 로고    scopus 로고
    • Intrathoracic blood volume and global end-diastolic volume should be included among indexes used in intensive care for assessment of fluid responsiveness in spontaneously breathing patients
    • [author reply 7]
    • A. Perel Intrathoracic blood volume and global end-diastolic volume should be included among indexes used in intensive care for assessment of fluid responsiveness in spontaneously breathing patients Crit Care Med 34 8 2006 2266 2267 [author reply 7]
    • (2006) Crit Care Med , vol.34 , Issue.8 , pp. 2266-2267
    • Perel, A.1
  • 29
    • 34648825072 scopus 로고    scopus 로고
    • Global end-diastolic volume as a variable of fluid responsiveness during acute changing loading conditions
    • J. Renner, M. Gruenewald, and P. Brand Global end-diastolic volume as a variable of fluid responsiveness during acute changing loading conditions J Cardiothorac Vasc Anesth 21 5 2007 650 654
    • (2007) J Cardiothorac Vasc Anesth , vol.21 , Issue.5 , pp. 650-654
    • Renner, J.1    Gruenewald, M.2    Brand, P.3
  • 30
    • 37349093358 scopus 로고    scopus 로고
    • Global end-diastolic volume during different loading conditions in a pediatric animal model
    • J. Renner, P. Meybohm, and M. Gruenewald Global end-diastolic volume during different loading conditions in a pediatric animal model Anesth Analg 105 5 2007 1243 1249
    • (2007) Anesth Analg , vol.105 , Issue.5 , pp. 1243-1249
    • Renner, J.1    Meybohm, P.2    Gruenewald, M.3
  • 31
    • 3843116717 scopus 로고    scopus 로고
    • Arterial cannulation: A critical review
    • T.R. Cousins, and J.M. O'Donnell Arterial cannulation: a critical review AANA J 72 4 2004 267 271
    • (2004) AANA J , vol.72 , Issue.4 , pp. 267-271
    • Cousins, T.R.1    O'Donnell, J.M.2
  • 32
    • 66149118641 scopus 로고    scopus 로고
    • Femoral-radial arterial pressure gradients in critically ill patients
    • S.T. Galluccio, M.J. Chapman, and M.E. Finnis Femoral-radial arterial pressure gradients in critically ill patients Crit Care Resusc 11 1 2009 34 38
    • (2009) Crit Care Resusc , vol.11 , Issue.1 , pp. 34-38
    • Galluccio, S.T.1    Chapman, M.J.2    Finnis, M.E.3
  • 33
    • 79952965623 scopus 로고    scopus 로고
    • Complications related to less-invasive haemodynamic monitoring
    • F.J. Belda, G. Aguilar, and J.L. Teboul Complications related to less-invasive haemodynamic monitoring Br J Anaesth 106 4 2011 482 486
    • (2011) Br J Anaesth , vol.106 , Issue.4 , pp. 482-486
    • Belda, F.J.1    Aguilar, G.2    Teboul, J.L.3
  • 34
    • 79953820585 scopus 로고    scopus 로고
    • Interpretation of the transpulmonary thermodilution curve in the presence of a left-to-right shunt
    • [author reply 2-3]
    • A. Nusmeier, J.G. van der Hoeven, and J. Lemson Interpretation of the transpulmonary thermodilution curve in the presence of a left-to-right shunt Intensive Care Med 37 3 2011 550 551 [author reply 2-3]
    • (2011) Intensive Care Med , vol.37 , Issue.3 , pp. 550-551
    • Nusmeier, A.1    Van Der Hoeven, J.G.2    Lemson, J.3
  • 35
    • 1642492872 scopus 로고    scopus 로고
    • Monitoring right-to-left intracardiac shunt in acute respiratory distress syndrome
    • F. Michard, S. Alaya, and F. Medkour Monitoring right-to-left intracardiac shunt in acute respiratory distress syndrome Crit Care Med 32 1 2004 308 309
    • (2004) Crit Care Med , vol.32 , Issue.1 , pp. 308-309
    • Michard, F.1    Alaya, S.2    Medkour, F.3
  • 36
    • 0027195184 scopus 로고
    • Computation of aortic flow from pressure in humans using a nonlinear, three-element model
    • K.H. Wesseling, J.R. Jansen, and J.J. Settels Computation of aortic flow from pressure in humans using a nonlinear, three-element model J Appl Physiol 74 5 1993 2566 2573
    • (1993) J Appl Physiol , vol.74 , Issue.5 , pp. 2566-2573
    • Wesseling, K.H.1    Jansen, J.R.2    Settels, J.J.3
  • 37
    • 79953017467 scopus 로고    scopus 로고
    • Cardiac output monitoring: An integrative perspective
    • J.A. Alhashemi, M. Cecconi, and C.K. Hofer Cardiac output monitoring: an integrative perspective Crit Care 15 2 2011 214
    • (2011) Crit Care , vol.15 , Issue.2 , pp. 214
    • Alhashemi, J.A.1    Cecconi, M.2    Hofer, C.K.3
  • 38
    • 0032734448 scopus 로고    scopus 로고
    • Continuous cardiac output by femoral arterial thermodilution calibrated pulse contour analysis: Comparison with pulmonary arterial thermodilution
    • O. Goedje, K. Hoeke, and M. Lichtwarck-Aschoff Continuous cardiac output by femoral arterial thermodilution calibrated pulse contour analysis: comparison with pulmonary arterial thermodilution Crit Care Med 27 11 1999 2407 2412
    • (1999) Crit Care Med , vol.27 , Issue.11 , pp. 2407-2412
    • Goedje, O.1    Hoeke, K.2    Lichtwarck-Aschoff, M.3
  • 39
    • 34250805960 scopus 로고    scopus 로고
    • The reliability of pulse contour-derived cardiac output during hemorrhage and after vasopressor administration
    • B. Bein, P. Meybohm, and E. Cavus The reliability of pulse contour-derived cardiac output during hemorrhage and after vasopressor administration Anesth Analg 105 1 2007 107 113
    • (2007) Anesth Analg , vol.105 , Issue.1 , pp. 107-113
    • Bein, B.1    Meybohm, P.2    Cavus, E.3
  • 41
    • 70350442849 scopus 로고    scopus 로고
    • Validation of continuous cardiac output technologies: Consensus still awaited
    • M. Cecconi, and A. Rhodes Validation of continuous cardiac output technologies: consensus still awaited Crit Care 13 3 2009 159
    • (2009) Crit Care , vol.13 , Issue.3 , pp. 159
    • Cecconi, M.1    Rhodes, A.2
  • 42
    • 77953533489 scopus 로고    scopus 로고
    • Intraoperative fluid optimization using stroke volume variation in high risk surgical patients: Results of prospective randomized study
    • J. Benes, I. Chytra, and P. Altmann Intraoperative fluid optimization using stroke volume variation in high risk surgical patients: results of prospective randomized study Crit Care 14 3 2010 R118
    • (2010) Crit Care , vol.14 , Issue.3 , pp. 118
    • Benes, J.1    Chytra, I.2    Altmann, P.3
  • 43
    • 84865017866 scopus 로고    scopus 로고
    • A comparison of third-generation semi-invasive arterial waveform analysis with thermodilution in patients undergoing coronary surgery
    • O. Broch, J. Renner, and M. Gruenewald A comparison of third-generation semi-invasive arterial waveform analysis with thermodilution in patients undergoing coronary surgery ScientificWorldJournal 2012 2012 451081
    • (2012) ScientificWorldJournal , vol.2012 , pp. 451081
    • Broch, O.1    Renner, J.2    Gruenewald, M.3
  • 44
    • 79953827557 scopus 로고    scopus 로고
    • Arterial pressure-based cardiac output monitoring: A multicenter validation of the third-generation software in septic patients
    • D. De Backer, G. Marx, and A. Tan Arterial pressure-based cardiac output monitoring: a multicenter validation of the third-generation software in septic patients Intensive Care Med 37 2 2011 233 240
    • (2011) Intensive Care Med , vol.37 , Issue.2 , pp. 233-240
    • De Backer, D.1    Marx, G.2    Tan, A.3
  • 45
    • 84878336009 scopus 로고    scopus 로고
    • Cardiac output monitoring in septic shock: Evaluation of the third-generation Flotrac-Vigileo (R)
    • S. Marque, A. Gros, and L. Chimot Cardiac output monitoring in septic shock: evaluation of the third-generation Flotrac-Vigileo (R) J Clin Monit Comput 27 3 2013 Jun 273 279
    • (2013) J Clin Monit Comput , vol.27 , Issue.3 , pp. 273-279
    • Marque, S.1    Gros, A.2    Chimot, L.3
  • 46
    • 84858433268 scopus 로고    scopus 로고
    • Third-generation FloTrac/Vigileo does not reliably track changes in cardiac output induced by norepinephrine in critically ill patients
    • X. Monnet, N. Anguel, and M. Jozwiak Third-generation FloTrac/Vigileo does not reliably track changes in cardiac output induced by norepinephrine in critically ill patients Br J Anaesth 108 4 2012 615 622
    • (2012) Br J Anaesth , vol.108 , Issue.4 , pp. 615-622
    • Monnet, X.1    Anguel, N.2    Jozwiak, M.3
  • 47
    • 84880528583 scopus 로고    scopus 로고
    • Systemic vascular resistance has an impact on the reliability of the Vigileo-FloTrac system in measuring cardiac output and tracking cardiac output changes
    • [Epub ahead of print]
    • K. Suehiro, K. Tanaka, and T. Funao Systemic vascular resistance has an impact on the reliability of the Vigileo-FloTrac system in measuring cardiac output and tracking cardiac output changes Br J Anaesth 2013 Mar 10 [Epub ahead of print]
    • (2013) Br J Anaesth
    • Suehiro, K.1    Tanaka, K.2    Funao, T.3
  • 48
    • 56349120707 scopus 로고    scopus 로고
    • Reliability of continuous cardiac output measurement during intra-abdominal hypertension relies on repeated calibrations: An experimental animal study
    • M. Gruenewald, J. Renner, and P. Meybohm Reliability of continuous cardiac output measurement during intra-abdominal hypertension relies on repeated calibrations: an experimental animal study Crit Care 12 5 2008 R132
    • (2008) Crit Care , vol.12 , Issue.5 , pp. 132
    • Gruenewald, M.1    Renner, J.2    Meybohm, P.3
  • 49
    • 84855993098 scopus 로고    scopus 로고
    • Validation of the LiDCO pulse contour system in patients with impaired left ventricular function
    • [author reply 188-9]
    • I. Mowat, E. Todman, and S. Jaggar Validation of the LiDCO pulse contour system in patients with impaired left ventricular function Anaesthesia 67 2 2012 188 [author reply 188-9]
    • (2012) Anaesthesia , vol.67 , Issue.2 , pp. 188
    • Mowat, I.1    Todman, E.2    Jaggar, S.3
  • 50
    • 79952062181 scopus 로고    scopus 로고
    • Uncalibrated pulse power analysis fails to reliably measure cardiac output in patients undergoing coronary artery bypass surgery
    • O. Broch, J. Renner, and J. Hocker Uncalibrated pulse power analysis fails to reliably measure cardiac output in patients undergoing coronary artery bypass surgery Crit Care 15 1 2011 R76
    • (2011) Crit Care , vol.15 , Issue.1 , pp. 76
    • Broch, O.1    Renner, J.2    Hocker, J.3
  • 51
    • 84874382964 scopus 로고    scopus 로고
    • Stroke volume optimization in elective bowel surgery: A comparison between pulse power wave analysis (LiDCOrapid) and oesophageal Doppler (CardioQ)
    • J. Nordstrom, C. Hallsjo-Sander, and R. Shore Stroke volume optimization in elective bowel surgery: a comparison between pulse power wave analysis (LiDCOrapid) and oesophageal Doppler (CardioQ) Br J Anaesth 110 3 2013 374 380
    • (2013) Br J Anaesth , vol.110 , Issue.3 , pp. 374-380
    • Nordstrom, J.1    Hallsjo-Sander, C.2    Shore, R.3
  • 52
    • 78049488760 scopus 로고    scopus 로고
    • Pulse contour cardiac output derived from non-invasive arterial pressure in cardiovascular disease
    • L.W. Bogert, K.H. Wesseling, and O. Schraa Pulse contour cardiac output derived from non-invasive arterial pressure in cardiovascular disease Anaesthesia 65 11 2010 1119 1125
    • (2010) Anaesthesia , vol.65 , Issue.11 , pp. 1119-1125
    • Bogert, L.W.1    Wesseling, K.H.2    Schraa, O.3
  • 53
  • 54
    • 0034869820 scopus 로고    scopus 로고
    • A comparison of cardiac output derived from the arterial pressure wave against thermodilution in cardiac surgery patients
    • J.R. Jansen, J.J. Schreuder, and J.P. Mulier A comparison of cardiac output derived from the arterial pressure wave against thermodilution in cardiac surgery patients Br J Anaesth 87 2 2001 212 222
    • (2001) Br J Anaesth , vol.87 , Issue.2 , pp. 212-222
    • Jansen, J.R.1    Schreuder, J.J.2    Mulier, J.P.3
  • 55
    • 0005928630 scopus 로고    scopus 로고
    • Continuous stroke volume monitoring by modelling flow from non-invasive measurement of arterial pressure in humans under orthostatic stress
    • M.P. Harms, K.H. Wesseling, and F. Pott Continuous stroke volume monitoring by modelling flow from non-invasive measurement of arterial pressure in humans under orthostatic stress Clin Sci (Lond) 97 3 1999 291 301
    • (1999) Clin Sci (Lond) , vol.97 , Issue.3 , pp. 291-301
    • Harms, M.P.1    Wesseling, K.H.2    Pott, F.3
  • 56
    • 0032942194 scopus 로고    scopus 로고
    • Continuous cardiac output in septic shock by simulating a model of the aortic input impedance: A comparison with bolus injection thermodilution
    • W.T. Jellema, K.H. Wesseling, and A.B. Groeneveld Continuous cardiac output in septic shock by simulating a model of the aortic input impedance: a comparison with bolus injection thermodilution Anesthesiology 90 5 1999 1317 1328
    • (1999) Anesthesiology , vol.90 , Issue.5 , pp. 1317-1328
    • Jellema, W.T.1    Wesseling, K.H.2    Groeneveld, A.B.3
  • 57
    • 84858342283 scopus 로고    scopus 로고
    • A comparison of the Nexfin(R) and transcardiopulmonary thermodilution to estimate cardiac output during coronary artery surgery
    • O. Broch, J. Renner, and M. Gruenewald A comparison of the Nexfin(R) and transcardiopulmonary thermodilution to estimate cardiac output during coronary artery surgery Anaesthesia 67 4 2012 377 383
    • (2012) Anaesthesia , vol.67 , Issue.4 , pp. 377-383
    • Broch, O.1    Renner, J.2    Gruenewald, M.3
  • 58
    • 84867900309 scopus 로고    scopus 로고
    • The estimation of cardiac output by the Nexfin device is of poor reliability for tracking the effects of a fluid challenge
    • X. Monnet, F. Picard, and E. Lidzborski The estimation of cardiac output by the Nexfin device is of poor reliability for tracking the effects of a fluid challenge Crit Care 16 5 2012 R212
    • (2012) Crit Care , vol.16 , Issue.5 , pp. 212
    • Monnet, X.1    Picard, F.2    Lidzborski, E.3
  • 59
    • 34447131664 scopus 로고    scopus 로고
    • Noninvasive cardiac output monitoring (NICOM): A clinical validation
    • P. Squara, D. Denjean, and P. Estagnasie Noninvasive cardiac output monitoring (NICOM): a clinical validation Intensive Care Med 33 7 2007 1191 1194
    • (2007) Intensive Care Med , vol.33 , Issue.7 , pp. 1191-1194
    • Squara, P.1    Denjean, D.2    Estagnasie, P.3
  • 60
    • 67249088798 scopus 로고    scopus 로고
    • Comparison between Flotrac-Vigileo and bioreactance, a totally noninvasive method for cardiac output monitoring
    • S. Marque, A. Cariou, and J.D. Chiche Comparison between Flotrac-Vigileo and bioreactance, a totally noninvasive method for cardiac output monitoring Crit Care 13 3 2009 R73
    • (2009) Crit Care , vol.13 , Issue.3 , pp. 73
    • Marque, S.1    Cariou, A.2    Chiche, J.D.3
  • 61
    • 84869162516 scopus 로고    scopus 로고
    • Cardiac output measurements using the bioreactance technique in critically ill patients
    • D. Fagnoul, J.L. Vincent, and D.D. Backer Cardiac output measurements using the bioreactance technique in critically ill patients Crit Care 16 6 2012 460
    • (2012) Crit Care , vol.16 , Issue.6 , pp. 460
    • Fagnoul, D.1    Vincent, J.L.2    Backer, D.D.3
  • 62
    • 33745697192 scopus 로고    scopus 로고
    • Transoesophageal echocardiography (TOE) in the operating room
    • J.D. Kneeshaw Transoesophageal echocardiography (TOE) in the operating room Br J Anaesth 97 1 2006 77 84
    • (2006) Br J Anaesth , vol.97 , Issue.1 , pp. 77-84
    • Kneeshaw, J.D.1
  • 63
    • 0041784903 scopus 로고    scopus 로고
    • ACC/AHA/ASE 2003 guideline update for the clinical application of echocardiography: Summary article: A report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (ACC/AHA/ASE Committee to Update the 1997 Guidelines for the Clinical Application of Echocardiography)
    • M.D. Cheitlin, W.F. Armstrong, and G.P. Aurigemma ACC/AHA/ASE 2003 guideline update for the clinical application of echocardiography: summary article: a report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (ACC/AHA/ASE Committee to Update the 1997 Guidelines for the Clinical Application of Echocardiography) Circulation 108 9 2003 1146 1162
    • (2003) Circulation , vol.108 , Issue.9 , pp. 1146-1162
    • Cheitlin, M.D.1    Armstrong, W.F.2    Aurigemma, G.P.3
  • 64
    • 0030053416 scopus 로고    scopus 로고
    • Transgastric, pulsed Doppler echocardiographic determination of cardiac output
    • A. Descorps-Declere, N. Smail, and B. Vigue Transgastric, pulsed Doppler echocardiographic determination of cardiac output Intensive Care Med 22 1 1996 34 38
    • (1996) Intensive Care Med , vol.22 , Issue.1 , pp. 34-38
    • Descorps-Declere, A.1    Smail, N.2    Vigue, B.3
  • 65
    • 0345131662 scopus 로고    scopus 로고
    • Intraoperative determination of cardiac output using multiplane transesophageal echocardiography: A comparison to thermodilution
    • A.C. Perrino Jr., S.N. Harris, and M.A. Luther Intraoperative determination of cardiac output using multiplane transesophageal echocardiography: a comparison to thermodilution Anesthesiology 89 2 1998 350 357
    • (1998) Anesthesiology , vol.89 , Issue.2 , pp. 350-357
    • Perrino, Jr.A.C.1    Harris, S.N.2    Luther, M.A.3
  • 66
    • 0028968403 scopus 로고
    • Multiplane transesophageal echocardiographic Doppler imaging accurately determines cardiac output measurements in critically ill patients
    • M.S. Feinberg, W.E. Hopkins, and V.G. Davila-Roman Multiplane transesophageal echocardiographic Doppler imaging accurately determines cardiac output measurements in critically ill patients Chest 107 3 1995 769 773
    • (1995) Chest , vol.107 , Issue.3 , pp. 769-773
    • Feinberg, M.S.1    Hopkins, W.E.2    Davila-Roman, V.G.3
  • 67
    • 0033385303 scopus 로고    scopus 로고
    • Measurement of cardiac output by transoesophageal echocardiography: A comparison of two Doppler methods with thermodilution
    • C.F. Royse, A.G. Royse, and D.W. Blake Measurement of cardiac output by transoesophageal echocardiography: a comparison of two Doppler methods with thermodilution Anaesth Intensive Care 27 6 1999 586 590
    • (1999) Anaesth Intensive Care , vol.27 , Issue.6 , pp. 586-590
    • Royse, C.F.1    Royse, A.G.2    Blake, D.W.3
  • 68
    • 0030119507 scopus 로고    scopus 로고
    • Training, certification, and credentialing in transesophageal echocardiography
    • D.M. Thys Training, certification, and credentialing in transesophageal echocardiography J Cardiothorac Vasc Anesth 10 3 1996 309 310
    • (1996) J Cardiothorac Vasc Anesth , vol.10 , Issue.3 , pp. 309-310
    • Thys, D.M.1
  • 69
    • 68049142922 scopus 로고    scopus 로고
    • Oesophageal Doppler
    • M. Singer Oesophageal Doppler Curr Opin Crit Care 15 3 2009 244 248
    • (2009) Curr Opin Crit Care , vol.15 , Issue.3 , pp. 244-248
    • Singer, M.1
  • 70
    • 63649109675 scopus 로고    scopus 로고
    • Systematic review of the clinical effectiveness and cost-effectiveness of oesophageal Doppler monitoring in critically ill and high-risk surgical patients
    • G. Mowatt, G. Houston, and R. Hernandez Systematic review of the clinical effectiveness and cost-effectiveness of oesophageal Doppler monitoring in critically ill and high-risk surgical patients Health Technol Assess 13 7 2009 1 95
    • (2009) Health Technol Assess , vol.13 , Issue.7 , pp. 1-95
    • Mowatt, G.1    Houston, G.2    Hernandez, R.3
  • 71
    • 34948909129 scopus 로고    scopus 로고
    • Goal-directed fluid management based on pulse pressure variation monitoring during high-risk surgery: A pilot randomized controlled trial
    • M.R. Lopes, M.A. Oliveira, and V.O. Pereira Goal-directed fluid management based on pulse pressure variation monitoring during high-risk surgery: a pilot randomized controlled trial Crit Care 11 5 2007 R100
    • (2007) Crit Care , vol.11 , Issue.5 , pp. 100
    • Lopes, M.R.1    Oliveira, M.A.2    Pereira, V.O.3
  • 72
    • 33745727003 scopus 로고    scopus 로고
    • Performing perioperative optimization of the high-risk surgical patient
    • S.P. Tote, and R.M. Grounds Performing perioperative optimization of the high-risk surgical patient Br J Anaesth 97 1 2006 4 11
    • (2006) Br J Anaesth , vol.97 , Issue.1 , pp. 4-11
    • Tote, S.P.1    Grounds, R.M.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.