메뉴 건너뛰기




Volumn 72, Issue 4, 2004, Pages 267-271

Arterial cannulation: A critical review

Author keywords

Arterial cannulation; Site review

Indexed keywords

AORTA; AORTA PRESSURE; ARTERY CATHETERIZATION; AXILLARY ARTERY; BIBLIOGRAPHIC DATABASE; BRACHIAL ARTERY; BRACHIAL PLEXUS INJURY; CATHETER INFECTION; CINAHL; COLLATERAL CIRCULATION; FEMORAL ARTERY; HEMODYNAMIC MONITORING; HUMAN; MEDIAN NERVE; MEDIAN NERVE INJURY; MEDLINE; NERVE INJURY; PULSE WAVE; RADIAL ARTERY; REVIEW; SYSTEMATIC REVIEW; THROMBOSIS; TISSUE INJURY; WAVEFORM; WAVEFORM DISTORTION;

EID: 3843116717     PISSN: 00946354     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Review
Times cited : (68)

References (27)
  • 1
    • 0035290275 scopus 로고    scopus 로고
    • Radial arterial lines and sticks: What are the risks?
    • Durbin CG Jr. Radial arterial lines and sticks: what are the risks? Respir Care. 2001;46:229-230.
    • (2001) Respir Care , vol.46 , pp. 229-230
    • Durbin Jr., C.G.1
  • 2
    • 0031824677 scopus 로고    scopus 로고
    • Incidence and patterns of iatrogenic arterial injuries: A decade's experience
    • Lazarides MK, Tsoupanos SS, Georgopoulos SE, et al. Incidence and patterns of iatrogenic arterial injuries: a decade's experience. J Cardiovasc Surg. 1998;39:281-285.
    • (1998) J Cardiovasc Surg , vol.39 , pp. 281-285
    • Lazarides, M.K.1    Tsoupanos, S.S.2    Georgopoulos, S.E.3
  • 3
    • 0031717777 scopus 로고    scopus 로고
    • Radial artery pressure monitoring underestimates central arterial pressure during vasopressor therapy in critically ill surgical patients
    • Dorman T, Breslow M, Lipsett PA, et al. Radial artery pressure monitoring underestimates central arterial pressure during vasopressor therapy in critically ill surgical patients. Crit Care Med. 1998;26:1646-1649.
    • (1998) Crit Care Med , vol.26 , pp. 1646-1649
    • Dorman, T.1    Breslow, M.2    Lipsett, P.A.3
  • 4
    • 0017922194 scopus 로고
    • Long-term radial artery cannulation: Effects on subsequent vessel formation
    • Bedford RF. Long-term radial artery cannulation: effects on subsequent vessel formation. Crit Care Med. 1978;6:64-67.
    • (1978) Crit Care Med , vol.6 , pp. 64-67
    • Bedford, R.F.1
  • 6
    • 0035092534 scopus 로고    scopus 로고
    • Long term arterial cannulation in lCU patients using the radial artery or dorsalis pedis artery
    • Martin C, Sauz P, Papazian L, Gouin F. Long term arterial cannulation in lCU patients using the radial artery or dorsalis pedis artery. Chest. 2001;119:901-906.
    • (2001) Chest , vol.119 , pp. 901-906
    • Martin, C.1    Sauz, P.2    Papazian, L.3    Gouin, F.4
  • 7
    • 0023636274 scopus 로고
    • The Allen test: An investigation of its accuracy by fluorescein angiography
    • McGregor AD. The Allen test: an investigation of its accuracy by fluorescein angiography. J Hand Surg [Br]. 1987;12:82-85.
    • (1987) J Hand Surg [Br] , vol.12 , pp. 82-85
    • McGregor, A.D.1
  • 9
    • 0025337053 scopus 로고
    • Comparison of brachial and radial arterial pressure monitoring in patients undergoing coronary artery bypass surgery
    • Bazaral MG, Welch M, Golding LA, Badhwar K. Comparison of brachial and radial arterial pressure monitoring in patients undergoing coronary artery bypass surgery. Anesthesiology. 1990;73:38-45.
    • (1990) Anesthesiology , vol.73 , pp. 38-45
    • Bazaral, M.G.1    Welch, M.2    Golding, L.A.3    Badhwar, K.4
  • 10
    • 0026769004 scopus 로고
    • Influence of arterial access sites and interventional procedures on vascular complications after cardiac catheterizations
    • Khoury M, Batra S, Berg R, Kumara R. Influence of arterial access sites and interventional procedures on vascular complications after cardiac catheterizations. Am J Surg. 1992;164:205-209.
    • (1992) Am J Surg , vol.164 , pp. 205-209
    • Khoury, M.1    Batra, S.2    Berg, R.3    Kumara, R.4
  • 12
    • 0016982419 scopus 로고
    • Axillary arterial monitoring
    • DeAngelis J. Axillary arterial monitoring. Crit Care Med. 1976;4:205-206.
    • (1976) Crit Care Med , vol.4 , pp. 205-206
    • DeAngelis, J.1
  • 16
    • 0021914529 scopus 로고
    • Cannulation of big arteries in critically ill patients
    • Gurman GM, Kriemerman S. Cannulation of big arteries in critically ill patients. Crit Care Med. 1985;13:217-220.
    • (1985) Crit Care Med , vol.13 , pp. 217-220
    • Gurman, G.M.1    Kriemerman, S.2
  • 17
    • 0021048417 scopus 로고
    • Prospective evaluation of radial and femoral artery catheterization sites in critically ill patients
    • Russell JA, Joel M, Hudson RJ, Mangano DT, Schlobohm RM. Prospective evaluation of radial and femoral artery catheterization sites in critically ill patients. Crit Care Med. 1983;11:936-939.
    • (1983) Crit Care Med , vol.11 , pp. 936-939
    • Russell, J.A.1    Joel, M.2    Hudson, R.J.3    Mangano, D.T.4    Schlobohm, R.M.5
  • 18
    • 0023874627 scopus 로고
    • Complications of invasive hemodynamic monitoring in the intensive care unit
    • Sladen A. Complications of invasive hemodynamic monitoring in the intensive care unit. Curr Probl Surg. 1988;25:69-145.
    • (1988) Curr Probl Surg , vol.25 , pp. 69-145
    • Sladen, A.1
  • 19
    • 0027535538 scopus 로고
    • Ischemic complications of radial artery cannulation: An association with a calcinosis, Raynaud's phenomena, esophageal dysmotility, sclerodactyly, and telangiectasia variant of scleroderma
    • Rose SH. Ischemic complications of radial artery cannulation: an association with a calcinosis, Raynaud's phenomena, esophageal dysmotility, sclerodactyly, and telangiectasia variant of scleroderma. Anesthesiology. 1993;78:587-589.
    • (1993) Anesthesiology , vol.78 , pp. 587-589
    • Rose, S.H.1
  • 20
    • 0020617745 scopus 로고
    • On the safety of radial artery cannulation
    • Slogoff S, Keats AS, Arlund C. On the safety of radial artery cannulation. Anesthesiology. 1983;59:42-47.
    • (1983) Anesthesiology , vol.59 , pp. 42-47
    • Slogoff, S.1    Keats, A.S.2    Arlund, C.3
  • 21
    • 0017250820 scopus 로고
    • Safety of brachial artery catheters as monitors in the intensive care unit: A prospective evaluation with the ultrasonic velocity detector
    • Barnes RW, Foster EJ, Janssen A, Boutros AR. Safety of brachial artery catheters as monitors in the intensive care unit: a prospective evaluation with the ultrasonic velocity detector. Anesthesiology. 1976;44:260-264.
    • (1976) Anesthesiology , vol.44 , pp. 260-264
    • Barnes, R.W.1    Foster, E.J.2    Janssen, A.3    Boutros, A.R.4
  • 22
    • 0031951612 scopus 로고    scopus 로고
    • Arterial catheter use in surgical or medical intensive care units: An analysis of 4932 patients
    • Frezza EE, Mezghebe H. Arterial catheter use in surgical or medical intensive care units: an analysis of 4932 patients. Am Surg. 1998;64:127-131.
    • (1998) Am Surg , vol.64 , pp. 127-131
    • Frezza, E.E.1    Mezghebe, H.2
  • 23
    • 0027460281 scopus 로고
    • An analysis of the relationship between central and aortic and peripheral upper limb pressure waves in man
    • Karamanoglu M, O'Rourke MF, Avolio AP, Kelly RP. An analysis of the relationship between central and aortic and peripheral upper limb pressure waves in man. Eur Heart J. 1993;14:160-176.
    • (1993) Eur Heart J , vol.14 , pp. 160-176
    • Karamanoglu, M.1    O'Rourke, M.F.2    Avolio, A.P.3    Kelly, R.P.4
  • 24
    • 0028464181 scopus 로고
    • Thermoregulatory vasoconstriction increases the difference between femoral and radial arterial pressures
    • Urzua J, Sessler DI, Meneses G, Sacco CM, Canessa R, Lema G. Thermoregulatory vasoconstriction increases the difference between femoral and radial arterial pressures. J Clin Monit. 1994;10:229-236.
    • (1994) J Clin Monit , vol.10 , pp. 229-236
    • Urzua, J.1    Sessler, D.I.2    Meneses, G.3    Sacco, C.M.4    Canessa, R.5    Lema, G.6
  • 25
    • 0027161576 scopus 로고
    • Comparison of axillary artery or brachial artery pressure with aortic pressure after cardiopulmonary bypass using a long radial artery catheter
    • Van Beck JO, White RD, Abenstein JP, Mullany CJ, Orszulak TA. Comparison of axillary artery or brachial artery pressure with aortic pressure after cardiopulmonary bypass using a long radial artery catheter. J Cardiothorac Vasc Anesth. 1993;7:312-315.
    • (1993) J Cardiothorac Vasc Anesth , vol.7 , pp. 312-315
    • Van Beck, J.O.1    White, R.D.2    Abenstein, J.P.3    Mullany, C.J.4    Orszulak, T.A.5
  • 27
    • 0026753406 scopus 로고
    • Does radial artery pressure accurately reflect aortic pressure?
    • Pauca AL, Wallenhaupt SL, Kon ND, Tucker WY. Does radial artery pressure accurately reflect aortic pressure? Chest. 1992;102:1193-1198.
    • (1992) Chest , vol.102 , pp. 1193-1198
    • Pauca, A.L.1    Wallenhaupt, S.L.2    Kon, N.D.3    Tucker, W.Y.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.