-
1
-
-
0025186347
-
Rapid, sensitive analysis of protein mixtures by mass-spectrometry
-
Beavis, R.C.; Chait, B.T.: Rapid, sensitive analysis of protein mixtures by mass-spectrometry. Proc. Natl. Acad. Sci. U.S.A. 87(17), 6873-6877 (1990)
-
(1990)
Proc. Natl. Acad. Sci. U.S.A.
, vol.87
, Issue.17
, pp. 6873-6877
-
-
Beavis, R.C.1
Chait, B.T.2
-
2
-
-
0347834080
-
Mass spectrometry of synthetic polymers by UV-matrix-assisted laser desorption/ionization
-
10.1021/ac00046a036 1:CAS:528:DyaK38XlvFaltLs%3D
-
Bahr, U.; Deppe, A.; Karas, M.; Hillenkamp, F.; Giessmann, U.: Mass spectrometry of synthetic polymers by UV-matrix-assisted laser desorption/ionization. Anal. Chem. 64(22), 2866-2869 (1992)
-
(1992)
Anal. Chem.
, vol.64
, Issue.22
, pp. 2866-2869
-
-
Bahr, U.1
Deppe, A.2
Karas, M.3
Hillenkamp, F.4
Giessmann, U.5
-
3
-
-
19844366697
-
Characterization of polymers by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry: Molecular weight estimates in samples of varying polydispersity
-
10.1002/rcm.1290090514 1:CAS:528:DyaK2MXlt1Kjs7w%3D
-
Montaudo, G.; Montaudo, M.S.; Puglisi, C.; Samperi, F.: Characterization of polymers by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry: Molecular weight estimates in samples of varying polydispersity. Rapid Commun. Mass Spectrom. 9(5), 453-460 (1995)
-
(1995)
Rapid Commun. Mass Spectrom.
, vol.9
, Issue.5
, pp. 453-460
-
-
Montaudo, G.1
Montaudo, M.S.2
Puglisi, C.3
Samperi, F.4
-
4
-
-
0029325609
-
Characterization of polymers by matrix-assisted laser-desorption ionization-time of flight mass-spectrometry. End group determination and molecular-weight estimates in poly(ethylene glycols)
-
10.1021/ma00117a028 1:CAS:528:DyaK2MXlvFWktr0%3D
-
Montaudo, G.; Montaudo, M.S.; Puglisi, C.; Samperi, F.: Characterization of polymers by matrix-assisted laser-desorption ionization-time of flight mass-spectrometry. End group determination and molecular-weight estimates in poly(ethylene glycols). Macromolecules 28(13), 4562-4569 (1995)
-
(1995)
Macromolecules
, vol.28
, Issue.13
, pp. 4562-4569
-
-
Montaudo, G.1
Montaudo, M.S.2
Puglisi, C.3
Samperi, F.4
-
5
-
-
0029911398
-
Why does matrix-assisted laser desorption/ionization time-of-flight mass spectrometry give incorrect results for broad polymer distributions?
-
10.1002/(SICI)1097-0231(199609)10:12<1471: AID-RCM693>3.0.CO;2-X 1:CAS:528:DyaK28XmtFOisb0%3D
-
Martin, K.; Spickermann, J.; Räder, H.J.; Müllen, K.: Why does matrix-assisted laser desorption/ionization time-of-flight mass spectrometry give incorrect results for broad polymer distributions? Rapid Commun. Mass Spectrom. 10(12), 1471-1474 (1996)
-
(1996)
Rapid Commun. Mass Spectrom.
, vol.10
, Issue.12
, pp. 1471-1474
-
-
Martin, K.1
Spickermann, J.2
Räder, H.J.3
Müllen, K.4
-
6
-
-
0031572678
-
Mass discrimination in the analysis of polydisperse polymers by MALDI time-of-flight mass spectrometry. 1. Sample preparation and desorption/ ionization issues
-
10.1021/ac9702610 1:CAS:528:DyaK2sXlvFyiu7s%3D
-
Schriemer, D.C.; Li, L.: Mass discrimination in the analysis of polydisperse polymers by MALDI time-of-flight mass spectrometry. 1. Sample preparation and desorption/ionization issues. Anal. Chem. 69(20), 4169-4175 (1997)
-
(1997)
Anal. Chem.
, vol.69
, Issue.20
, pp. 4169-4175
-
-
Schriemer, D.C.1
Li, L.2
-
7
-
-
0031572630
-
Mass discrimination in the analysis of polydisperse polymers by MALDI time-of-flight mass spectrometry. 2. Instrumental issues
-
10.1021/ac9707794 1:CAS:528:DyaK2sXlvFyhsro%3D
-
Schriemer, D.C.; Li, L.: Mass discrimination in the analysis of polydisperse polymers by MALDI time-of-flight mass spectrometry. 2. Instrumental issues. Anal. Chem. 69(20), 4176-4183 (1997)
-
(1997)
Anal. Chem.
, vol.69
, Issue.20
, pp. 4176-4183
-
-
Schriemer, D.C.1
Li, L.2
-
8
-
-
0035093112
-
Evaluation of mass discrimination effects in the quantitative analysis of polydisperse polymers by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry using uniform oligostyrenes
-
10.1002/rcm.224 1:CAS:528:DC%2BD3MXhs1Siurs%3D
-
Shimada, K.; Lusenkova, M.A.; Sato, K.; Saito, T.; Matsuyama, S.; Nakahara, H.; Kinugasa, S.: Evaluation of mass discrimination effects in the quantitative analysis of polydisperse polymers by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry using uniform oligostyrenes. Rapid Commun. Mass Spectrom. 15(4), 277-282 (2001)
-
(2001)
Rapid Commun. Mass Spectrom.
, vol.15
, Issue.4
, pp. 277-282
-
-
Shimada, K.1
Lusenkova, M.A.2
Sato, K.3
Saito, T.4
Matsuyama, S.5
Nakahara, H.6
Kinugasa, S.7
-
9
-
-
0141458004
-
Evaluation of the quantitativeness of matrix-assisted laser desorption/ionization time-of-flight mass spectrometry using an equimolar mixture of uniform poly(ethylene glycol) oligomers
-
10.1002/jms.508 1:CAS:528:DC%2BD3sXntlals7k%3D
-
Shimada, K.; Nagahata, R.; Kawabata, S.-I.; Matsuyama, S.; Saito, T.; Kinugasa, S.: Evaluation of the quantitativeness of matrix-assisted laser desorption/ionization time-of-flight mass spectrometry using an equimolar mixture of uniform poly(ethylene glycol) oligomers. J. Mass Spectrom. 38(9), 948-954 (2003)
-
(2003)
J. Mass Spectrom.
, vol.38
, Issue.9
, pp. 948-954
-
-
Shimada, K.1
Nagahata, R.2
Kawabata, S.-I.3
Matsuyama, S.4
Saito, T.5
Kinugasa, S.6
-
10
-
-
0027240210
-
Matrix-assisted laser desorption ionization time-of-flight mass-spectrometry: A powerful tool for the mass and sequence analysis of natural and modified oligonucleotides
-
10.1093/nar/21.14.3191 1:CAS:528:DyaK3sXlsFGht7Y%3D
-
Pieles, U.; Zürcher, W.; Schär, M.; Moser, H.E.: Matrix-assisted laser desorption ionization time-of-flight mass-spectrometry: A powerful tool for the mass and sequence analysis of natural and modified oligonucleotides. Nucleic Acids Res. 21(14), 3191-3196 (1993)
-
(1993)
Nucleic Acids Res.
, vol.21
, Issue.14
, pp. 3191-3196
-
-
Pieles, U.1
Zürcher, W.2
Schär, M.3
Moser, H.E.4
-
11
-
-
0030047433
-
DNA sequencing by delayed extraction matrix-assisted laser desorption/ionization time of flight mass spectrometry
-
Roskey, M.T.; Juhasz, P.; Smirnov, I.P.; Takach, E.J.; Martin, S.A.; Haff, L.A.: DNA sequencing by delayed extraction matrix-assisted laser desorption/ionization time of flight mass spectrometry. Proc. Natl. Acad. Sci. U.S.A. 93(10), 4724-4729 (1996)
-
(1996)
Proc. Natl. Acad. Sci. U.S.A.
, vol.93
, Issue.10
, pp. 4724-4729
-
-
Roskey, M.T.1
Juhasz, P.2
Smirnov, I.P.3
Takach, E.J.4
Martin, S.A.5
Haff, L.A.6
-
12
-
-
0028796545
-
Analysis of enzymatic DNA-sequencing reactions by matrix-assisted laser-desorption ionization time-of-flight mass-spectrometry
-
10.1002/rcm.1290091015 1:CAS:528:DyaK2MXns12gsrk%3D
-
Shaler, T.A.; Tan, Y.; Wickham, J.N.; Wu, K.J.; Becker, C.H.: Analysis of enzymatic DNA-sequencing reactions by matrix-assisted laser-desorption ionization time-of-flight mass-spectrometry. Rapid Commun. Mass Spectrom. 9(10), 942-947 (1995)
-
(1995)
Rapid Commun. Mass Spectrom.
, vol.9
, Issue.10
, pp. 942-947
-
-
Shaler, T.A.1
Tan, Y.2
Wickham, J.N.3
Wu, K.J.4
Becker, C.H.5
-
13
-
-
0242291110
-
Mass spectrometric analysis of DNA mixtures: Instrumental effects responsible for decreased sensitivity with increasing mass
-
10.1021/ac030127h 1:CAS:528:DC%2BD3sXntlyrtb8%3D
-
Chen, X.; Westphall, M.S.; Smith, L.M.: Mass spectrometric analysis of DNA mixtures: Instrumental effects responsible for decreased sensitivity with increasing mass. Anal. Chem. 75(21), 5944-5952 (2003)
-
(2003)
Anal. Chem.
, vol.75
, Issue.21
, pp. 5944-5952
-
-
Chen, X.1
Westphall, M.S.2
Smith, L.M.3
-
14
-
-
0026410965
-
Assessing the multimeric states of proteins: Studies using laser desorption mass spectrometry
-
10.1002/bms.1200201209 1:CAS:528:DyaK38XlsVyqtw%3D%3D
-
Farmer, T.B.; Caprioli, R.M.: Assessing the multimeric states of proteins: Studies using laser desorption mass spectrometry. Biol. Mass Spectrom. 20(12), 796-800 (1991)
-
(1991)
Biol. Mass Spectrom.
, vol.20
, Issue.12
, pp. 796-800
-
-
Farmer, T.B.1
Caprioli, R.M.2
-
15
-
-
0031874403
-
Determination of protein-protein interactions by matrix-assisted laser desorption/ionization mass spectrometry
-
10.1002/(SICI)1096-9888(199808)33:8<697: AID-JMS711>3.0.CO;2-H 1:CAS:528:DyaK1cXmtVCju70%3D
-
Farmer, T.B.; Caprioli, R.M.: Determination of protein-protein interactions by matrix-assisted laser desorption/ionization mass spectrometry. J. Mass Spectrom. 33(8), 697-704 (1998)
-
(1998)
J. Mass Spectrom.
, vol.33
, Issue.8
, pp. 697-704
-
-
Farmer, T.B.1
Caprioli, R.M.2
-
16
-
-
77956881617
-
Does chemical cross-linking with NHS esters reflect the chemical equilibrium of protein-protein noncovalent interactions in solution?
-
10.1016/j.jasms.2010.06.016
-
Mädler, S.; Seitz, M.; Robinson, J.; Zenobi, R.: Does chemical cross-linking with NHS esters reflect the chemical equilibrium of protein-protein noncovalent interactions in solution? J. Am. Soc. Mass Spectrom. 21(10), 1775-1783 (2010)
-
(2010)
J. Am. Soc. Mass Spectrom.
, vol.21
, Issue.10
, pp. 1775-1783
-
-
Mädler, S.1
Seitz, M.2
Robinson, J.3
Zenobi, R.4
-
17
-
-
0037941316
-
Influence of response factors on determining equilibrium association constants of noncovalent complexes by electrospray ionization mass spectrometry
-
10.1002/jms.459 1:CAS:528:DC%2BD3sXksVKqtro%3D
-
Gabelica, V.; Galic, N.; Rosu, F.; Houssier, C.; De Pauw, E.: Influence of response factors on determining equilibrium association constants of noncovalent complexes by electrospray ionization mass spectrometry. J. Mass Spectrom. 38(5), 491-501 (2003)
-
(2003)
J. Mass Spectrom.
, vol.38
, Issue.5
, pp. 491-501
-
-
Gabelica, V.1
Galic, N.2
Rosu, F.3
Houssier, C.4
De Pauw, E.5
-
18
-
-
84875418865
-
A new, modular mass calibrant for high-mass MALDI-MS
-
10.1021/ac400129h 1:CAS:528:DC%2BC3sXit1ehsb0%3D
-
Weidmann, S.; Barylyuk, K.; Nespovitaya, N.; Mädler, S.; Zenobi, R.: A new, modular mass calibrant for high-mass MALDI-MS. Anal. Chem. 85(6), 3425-3432 (2013)
-
(2013)
Anal. Chem.
, vol.85
, Issue.6
, pp. 3425-3432
-
-
Weidmann, S.1
Barylyuk, K.2
Nespovitaya, N.3
Mädler, S.4
Zenobi, R.5
-
19
-
-
0029117359
-
Mass discrimination in matrix-assisted laser-desorption ionization time-of-flight mass-spectrometry: A study using cross-linked oligomeric complexes
-
10.1002/jms.1190300906 1:CAS:528:DyaK2MXotFWrurY%3D
-
Farmer, T.B.; Caprioli, R.M.: Mass discrimination in matrix-assisted laser-desorption ionization time-of-flight mass-spectrometry: A study using cross-linked oligomeric complexes. J. Mass Spectrom. 30(9), 1245-1254 (1995)
-
(1995)
J. Mass Spectrom.
, vol.30
, Issue.9
, pp. 1245-1254
-
-
Farmer, T.B.1
Caprioli, R.M.2
-
20
-
-
0018478296
-
Microchannel plate detectors
-
Wiza, J.L.: Microchannel plate detectors. Nucl. Inst. Methods 162(1-3), 587-601 (1979)
-
(1979)
Nucl. Inst. Methods
, vol.162
, Issue.1-3
, pp. 587-601
-
-
Wiza, J.L.1
-
21
-
-
0001254611
-
Threshold studies of secondary-electron emission induced by macro-ion impact on solid-surfaces
-
Beuhler, R.J.; Friedman, L.: Threshold studies of secondary-electron emission induced by macro-ion impact on solid-surfaces. Nucl. Inst. Methods 170(1-3), 309-315 (1980)
-
(1980)
Nucl. Inst. Methods
, vol.170
, Issue.1-3
, pp. 309-315
-
-
Beuhler, R.J.1
Friedman, L.2
-
22
-
-
0037689628
-
Secondary electron emission induced by impact of low-velocity molecular ions on a microchannel plate
-
10.1016/0168-1176(89)83028-9 1:CAS:528:DyaK3cXhvFyqu7w%3D
-
Geno, P.W.; Macfarlane, R.D.: Secondary electron emission induced by impact of low-velocity molecular ions on a microchannel plate. Int. J. Mass Spectrom. Ion Process. 92, 195-210 (1989)
-
(1989)
Int. J. Mass Spectrom. Ion Process.
, vol.92
, pp. 195-210
-
-
Geno, P.W.1
Macfarlane, R.D.2
-
23
-
-
43949164714
-
Surface secondary-electron and secondary-ion emission induced by large molecular ion impacts
-
10.1016/0168-1176(93)80071-L 1:CAS:528:DyaK3sXmtFGhu7k%3D
-
Brunelle, A.; Chaurand, P.; Della-Negra, S.; Le Beyec, Y.; Baptista, G.B.: Surface secondary-electron and secondary-ion emission induced by large molecular ion impacts. Int. J. Mass Spectrom. Ion Process. 126, 65-73 (1993)
-
(1993)
Int. J. Mass Spectrom. Ion Process.
, vol.126
, pp. 65-73
-
-
Brunelle, A.1
Chaurand, P.2
Della-Negra, S.3
Le Beyec, Y.4
Baptista, G.B.5
-
24
-
-
31444435811
-
Microchannel plate response to high-intensity ion bunches
-
10.1016/j.nima.2005.11.061 1:CAS:528:DC%2BD28XhtVOqsLs%3D
-
Coeck, S.; Beck, M.; Delauré, B.; Golovko, V.V.; Herbane, M.; Lindroth, A.; Kopecky, S.; Kozlov, V.Y.; Kraev, I.S.; Phalet, T.; Severijns, N.: Microchannel plate response to high-intensity ion bunches. Nucl. Inst. Methods A 557(2), 516-522 (2006)
-
(2006)
Nucl. Inst. Methods A
, vol.557
, Issue.2
, pp. 516-522
-
-
Coeck, S.1
Beck, M.2
Delauré, B.3
Golovko, V.V.4
Herbane, M.5
Lindroth, A.6
Kopecky, S.7
Kozlov, V.Y.8
Kraev, I.S.9
Phalet, T.10
Severijns, N.11
-
25
-
-
0033126156
-
Energy-sensitive cryogenic detectors for high-mass biomolecule mass spectrometry
-
Frank, M.; Labov, S.E.; Westmacott, G.; Benner, W.H.: Energy-sensitive cryogenic detectors for high-mass biomolecule mass spectrometry. Mass Spectrom. Rev. 18(3-4), 155-186 (1999)
-
(1999)
Mass Spectrom. Rev.
, vol.18
, Issue.3-4
, pp. 155-186
-
-
Frank, M.1
Labov, S.E.2
Westmacott, G.3
Benner, W.H.4
-
26
-
-
0036535074
-
Cryogenic detectors and their application to mass spectrometry
-
Kraus, H.: Cryogenic detectors and their application to mass spectrometry. Int. J. Mass Spectrom. 215(1-3), 45-58 (2002)
-
(2002)
Int. J. Mass Spectrom.
, vol.215
, Issue.1-3
, pp. 45-58
-
-
Kraus, H.1
-
27
-
-
80052804740
-
A mechanical nanomembrane detector for time-of-flight mass spectrometry
-
10.1021/nl201645u 1:CAS:528:DC%2BC3MXpslWqurk%3D
-
Park, J.; Qin, H.; Scalf, M.; Hilger, R.T.; Westphall, M.S.; Smith, L.M.; Blick, R.H.: A mechanical nanomembrane detector for time-of-flight mass spectrometry. Nano Lett. 11(9), 3681-3684 (2011)
-
(2011)
Nano Lett.
, vol.11
, Issue.9
, pp. 3681-3684
-
-
Park, J.1
Qin, H.2
Scalf, M.3
Hilger, R.T.4
Westphall, M.S.5
Smith, L.M.6
Blick, R.H.7
-
28
-
-
77956873796
-
A detector device for high mass ion detection, a method for analyzing ions of high mass and a device for selection between ion detectors
-
Patent WO2009086642-A1, July 16
-
Wenzel, R.J.; Röhling, U.; Nazabal, A.; Hillenkamp, F.: A detector device for high mass ion detection, a method for analyzing ions of high mass and a device for selection between ion detectors. Internat. Patent WO2009086642-A1, July 16 (2009).
-
(2009)
Internat.
-
-
Wenzel, R.J.1
Röhling, U.2
Nazabal, A.3
Hillenkamp, F.4
-
29
-
-
16244363702
-
The magic of cluster SIMS
-
10.1021/ac053355f 1:CAS:528:DC%2BD2MXivFajt78%3D A-149 A
-
Winograd, N.: The magic of cluster SIMS. Anal. Chem. 77(7), 142 A-149 A (2005)
-
(2005)
Anal. Chem.
, vol.77
, Issue.7
, pp. 142
-
-
Winograd, N.1
-
30
-
-
78650708928
-
Developments in molecular SIMS depth profiling and 3D imaging of biological systems using polyatomic primary ions
-
10.1002/mas.20275 1:CAS:528:DC%2BC3MXhsFymuro%3D
-
Fletcher, J.S.; Lockyer, N.P.; Vickerman, J.C.: Developments in molecular SIMS depth profiling and 3D imaging of biological systems using polyatomic primary ions. Mass Spectrom. Rev. 30(1), 142-174 (2011)
-
(2011)
Mass Spectrom. Rev.
, vol.30
, Issue.1
, pp. 142-174
-
-
Fletcher, J.S.1
Lockyer, N.P.2
Vickerman, J.C.3
-
31
-
-
84875792090
-
High-mass matrix-assisted laser desorption ionization-mass spectrometry of integral membrane proteins and their complexes
-
10.1021/ac4000943 1:CAS:528:DC%2BC3sXjs1yitLg%3D
-
Chen, F.; Gerber, S.; Heuser, K.; Korkhov, V.M.; Lizak, C.; Mireku, S.; Locher, K.P.; Zenobi, R.: High-mass matrix-assisted laser desorption ionization-mass spectrometry of integral membrane proteins and their complexes. Anal. Chem. 85(7), 3483-3488 (2013)
-
(2013)
Anal. Chem.
, vol.85
, Issue.7
, pp. 3483-3488
-
-
Chen, F.1
Gerber, S.2
Heuser, K.3
Korkhov, V.M.4
Lizak, C.5
Mireku, S.6
Locher, K.P.7
Zenobi, R.8
-
32
-
-
38049063892
-
Folding and unfolding mechanism of highly stable full-consensus ankyrin repeat proteins
-
10.1016/j.jmb.2007.11.046 1:CAS:528:DC%2BD1cXpt1ymtw%3D%3D
-
Wetzel, S.K.; Settanni, G.; Kenig, M.; Binz, H.K.; Plückthun, A.: Folding and unfolding mechanism of highly stable full-consensus ankyrin repeat proteins. J. Mol. Biol. 376(1), 241-257 (2008)
-
(2008)
J. Mol. Biol.
, vol.376
, Issue.1
, pp. 241-257
-
-
Wetzel, S.K.1
Settanni, G.2
Kenig, M.3
Binz, H.K.4
Plückthun, A.5
-
33
-
-
0042780350
-
Designing repeat proteins: Well-expressed, soluble and stable proteins from combinatorial libraries of consensus ankyrin repeat proteins
-
10.1016/S0022-2836(03)00896-9 1:CAS:528:DC%2BD3sXms1OqurY%3D
-
Binz, H.K.; Stumpp, M.T.; Forrer, P.; Amstutz, P.; Plückthun, A.: Designing repeat proteins: Well-expressed, soluble and stable proteins from combinatorial libraries of consensus ankyrin repeat proteins. J. Mol. Biol. 332(2), 489-503 (2003)
-
(2003)
J. Mol. Biol.
, vol.332
, Issue.2
, pp. 489-503
-
-
Binz, H.K.1
Stumpp, M.T.2
Forrer, P.3
Amstutz, P.4
Plückthun, A.5
-
34
-
-
4644360596
-
Consensus design of repeat proteins
-
10.1002/cbic.200300762 1:CAS:528:DC%2BD2cXhsFKgsLc%3D
-
Forrer, P.; Binz, H.K.; Stumpp, M.T.; Plückthun, A.: Consensus design of repeat proteins. ChemBioChem 5(2), 183-189 (2004)
-
(2004)
ChemBioChem
, vol.5
, Issue.2
, pp. 183-189
-
-
Forrer, P.1
Binz, H.K.2
Stumpp, M.T.3
Plückthun, A.4
-
35
-
-
83655192884
-
Quantifying protein-protein interactions within noncovalent complexes using electrospray ionization mass spectrometry
-
10.1021/ac201576e 1:CAS:528:DC%2BC3MXhsVSqsbrL
-
Boeri Erba, E.; Barylyuk, K.; Yang, Y.; Zenobi, R.: Quantifying protein-protein interactions within noncovalent complexes using electrospray ionization mass spectrometry. Anal. Chem. 83(24), 9251-9259 (2011)
-
(2011)
Anal. Chem.
, vol.83
, Issue.24
, pp. 9251-9259
-
-
Boeri Erba, E.1
Barylyuk, K.2
Yang, Y.3
Zenobi, R.4
-
36
-
-
0037329399
-
The desorption process in MALDI
-
10.1021/cr010375i 1:CAS:528:DC%2BD3sXlsFaruw%3D%3D
-
Dreisewerd, K.: The desorption process in MALDI. Chem. Rev. 103(2), 395-425 (2003)
-
(2003)
Chem. Rev.
, vol.103
, Issue.2
, pp. 395-425
-
-
Dreisewerd, K.1
-
37
-
-
33748160055
-
Ion formation mechanisms in UV-MALDI
-
10.1039/b605646f 1:CAS:528:DC%2BD28XosFGmsrY%3D
-
Knochenmuss, R.: Ion formation mechanisms in UV-MALDI. Analyst 131(9), 966-986 (2006)
-
(2006)
Analyst
, vol.131
, Issue.9
, pp. 966-986
-
-
Knochenmuss, R.1
-
38
-
-
39149114435
-
The analysis of polystyrene and polystyrene aggregates into the mega dalton mass range by cryodetection MALDI TOF MS
-
10.1016/j.jasms.2007.10.019 1:CAS:528:DC%2BD1cXitlyktLk%3D
-
Aksenov, A.A.; Bier, M.E.: The analysis of polystyrene and polystyrene aggregates into the mega dalton mass range by cryodetection MALDI TOF MS. J. Am. Soc. Mass Spectrom. 19(2), 219-230 (2008)
-
(2008)
J. Am. Soc. Mass Spectrom.
, vol.19
, Issue.2
, pp. 219-230
-
-
Aksenov, A.A.1
Bier, M.E.2
-
39
-
-
84881567613
-
Ionization processes and detection in MALDI-MS of polymers
-
L. Li (eds) John Wiley and Sons, Inc Hoboken, NJ 10.1002/9780470567234. ch2
-
Zenobi, R.: Ionization processes and detection in MALDI-MS of polymers. In: Li, L. (ed.) MALDI Mass Spectrometry for Synthetic Polymer Analysis, pp. 9-26. John Wiley and Sons, Inc, Hoboken, NJ (2009)
-
(2009)
MALDI Mass Spectrometry for Synthetic Polymer Analysis
, pp. 9-26
-
-
Zenobi, R.1
-
40
-
-
0001475924
-
Factors affecting the resolution in matrix-assisted laser desorption-ionization mass spectrometry
-
10.1016/0168-1176(93)03873-K 1:CAS:528:DyaK2cXis1Gjtbk%3D
-
Ingendoh, A.; Karas, M.; Hillenkamp, F.; Giessmann, U.: Factors affecting the resolution in matrix-assisted laser desorption-ionization mass spectrometry. Int. J. Mass Spectrom. Ion Process. 131, 345-354 (1994)
-
(1994)
Int. J. Mass Spectrom. Ion Process.
, vol.131
, pp. 345-354
-
-
Ingendoh, A.1
Karas, M.2
Hillenkamp, F.3
Giessmann, U.4
-
41
-
-
0037329166
-
MALDI ionization: The role of in-plume processes
-
10.1021/cr0103773 1:CAS:528:DC%2BD38XpsFCnsrc%3D
-
Knochenmuss, R.; Zenobi, R.: MALDI ionization: The role of in-plume processes. Chem. Rev. 103(2), 441-452 (2003)
-
(2003)
Chem. Rev.
, vol.103
, Issue.2
, pp. 441-452
-
-
Knochenmuss, R.1
Zenobi, R.2
-
42
-
-
23744516059
-
Estimates of protein surface areas in solution by electrospray ionization mass spectrometry
-
10.1021/ac050511+ 1:CAS:528:DC%2BD2MXls1WqsLo%3D
-
Kaltashov, I.A.; Mohimen, A.: Estimates of protein surface areas in solution by electrospray ionization mass spectrometry. Anal. Chem. 77(16), 5370-5379 (2005)
-
(2005)
Anal. Chem.
, vol.77
, Issue.16
, pp. 5370-5379
-
-
Kaltashov, I.A.1
Mohimen, A.2
-
43
-
-
0025754301
-
The 2.3-Å resolution structure of the maltose- or maltodextrin-binding protein, a primary receptor of bacterial active transport and chemotaxis
-
1:CAS:528:DyaK3MXhsF2gu7o%3D
-
Spurlino, J.C.; Lu, G.-Y.; Quiocho, F.A.: The 2.3-Å resolution structure of the maltose- or maltodextrin-binding protein, a primary receptor of bacterial active transport and chemotaxis. J. Biol. Chem. 266(8), 5202-5219 (1991)
-
(1991)
J. Biol. Chem.
, vol.266
, Issue.8
, pp. 5202-5219
-
-
Spurlino, J.C.1
Lu, G.-Y.2
Quiocho, F.A.3
-
44
-
-
2342624119
-
High-affinity binders selected from designed ankyrin repeat protein libraries
-
10.1038/nbt962 1:CAS:528:DC%2BD2cXjsF2jsLk%3D
-
Binz, H.K.; Amstutz, P.; Kohl, A.; Stumpp, M.T.; Briand, C.; Forrer, P.; Grütter, M.G.; Plückthun, A.: High-affinity binders selected from designed ankyrin repeat protein libraries. Nat. Biotechnol. 22(5), 575-582 (2004)
-
(2004)
Nat. Biotechnol.
, vol.22
, Issue.5
, pp. 575-582
-
-
Binz, H.K.1
Amstutz, P.2
Kohl, A.3
Stumpp, M.T.4
Briand, C.5
Forrer, P.6
Grütter, M.G.7
Plückthun, A.8
-
45
-
-
0037452697
-
Designed to be stable: Crystal structure of a consensus ankyrin repeat protein
-
Kohl, A.; Binz, H.K.; Forrer, P.; Stumpp, M.T.; Plückthun, A.; Grütter, M.G.: Designed to be stable: Crystal structure of a consensus ankyrin repeat protein. Proc. Natl. Acad. Sci. U.S.A. 100(4), 1700-1705 (2003)
-
(2003)
Proc. Natl. Acad. Sci. U.S.A.
, vol.100
, Issue.4
, pp. 1700-1705
-
-
Kohl, A.1
Binz, H.K.2
Forrer, P.3
Stumpp, M.T.4
Plückthun, A.5
Grütter, M.G.6
-
46
-
-
35148850244
-
Identification and thermodynamic characterization of molten globule states of periplasmic binding proteins
-
10.1021/bi700577m 1:CAS:528:DC%2BD2sXptVWks78%3D
-
Prajapati, R.S.; Indu, S.; Varadarajan, R.: Identification and thermodynamic characterization of molten globule states of periplasmic binding proteins. Biochemistry 46(36), 10339-10352 (2007)
-
(2007)
Biochemistry
, vol.46
, Issue.36
, pp. 10339-10352
-
-
Prajapati, R.S.1
Indu, S.2
Varadarajan, R.3
-
47
-
-
84856274818
-
Compelling advantages of negative ion mode detection in high-mass MALDI-MS for homomeric protein complexes
-
10.1007/s13361-011-0274-x
-
Mädler, S.; Barylyuk, K.; Boeri Erba, E.; Nieckarz, R.J.; Zenobi, R.: Compelling advantages of negative ion mode detection in high-mass MALDI-MS for homomeric protein complexes. J. Am. Soc. Mass Spectrom. 23(2), 213-224 (2012)
-
(2012)
J. Am. Soc. Mass Spectrom.
, vol.23
, Issue.2
, pp. 213-224
-
-
Mädler, S.1
Barylyuk, K.2
Boeri Erba, E.3
Nieckarz, R.J.4
Zenobi, R.5
|