메뉴 건너뛰기




Volumn 17, Issue 6, 2013, Pages 1601-1609

Accuracy of peri-implant bone thickness and validity of assessing bone augmentation material using cone beam computed tomography

Author keywords

3D Imaging; CBCT; Histological study; In vivo experiment; Linear measurement; Radiological study

Indexed keywords


EID: 84879440816     PISSN: 14326981     EISSN: 14363771     Source Type: Journal    
DOI: 10.1007/s00784-012-0841-y     Document Type: Article
Times cited : (32)

References (27)
  • 1
    • 67649397320 scopus 로고    scopus 로고
    • Cone-beam computerized tomography (CBCT) imaging of the oral and maxillofacial region: a systematic review of the literature
    • doi:10.1016/j.ijom.2009.02.028
    • De Vos W, Casselman J, Swennen GR (2009) Cone-beam computerized tomography (CBCT) imaging of the oral and maxillofacial region: a systematic review of the literature. Int J Oral Maxillofac Surg 38(6): 609-625. doi: 10. 1016/j. ijom. 2009. 02. 028.
    • (2009) Int J Oral Maxillofac Surg , vol.38 , Issue.6 , pp. 609-625
    • De Vos, W.1    Casselman, J.2    Swennen, G.R.3
  • 2
    • 77954576900 scopus 로고    scopus 로고
    • Accuracy of measuring the cortical bone thickness adjacent to dental implants using cone beam computed tomography
    • doi:10.1111/j.1600-0501.2009.01905.x
    • Razavi T, Palmer RM, Davies J, Wilson R, Palmer PJ (2010) Accuracy of measuring the cortical bone thickness adjacent to dental implants using cone beam computed tomography. Clin Oral Implants Res 21(7): 718-725. doi: 10. 1111/j. 1600-0501. 2009. 01905. x.
    • (2010) Clin Oral Implants Res , vol.21 , Issue.7 , pp. 718-725
    • Razavi, T.1    Palmer, R.M.2    Davies, J.3    Wilson, R.4    Palmer, P.J.5
  • 3
    • 84862235768 scopus 로고    scopus 로고
    • Accuracy of cone beam computed tomography in assessing peri-implant bone defect regeneration: a histologically controlled study in dogs
    • doi: 10. 1111/j. 1600-0501. 2011. 02232. x
    • Fienitz T, Schwarz F, Ritter L, Dreiseidler T, Becker J, Rothamel D (2011) Accuracy of cone beam computed tomography in assessing peri-implant bone defect regeneration: a histologically controlled study in dogs. Clin Oral Implants Res. doi: 10. 1111/j. 1600-0501. 2011. 02232. x.
    • (2011) Clin Oral Implants Res
    • Fienitz, T.1    Schwarz, F.2    Ritter, L.3    Dreiseidler, T.4    Becker, J.5    Rothamel, D.6
  • 4
    • 79960947543 scopus 로고    scopus 로고
    • Dental cone beam computed tomography analyses of postoperative labial bone thickness in maxillary anterior implants: comparing immediate and delayed implant placement
    • Miyamoto Y, Obama T (2011) Dental cone beam computed tomography analyses of postoperative labial bone thickness in maxillary anterior implants: comparing immediate and delayed implant placement. Int J Periodontics Restorative Dent 31(3): 215-225.
    • (2011) Int J Periodontics Restorative Dent , vol.31 , Issue.3 , pp. 215-225
    • Miyamoto, Y.1    Obama, T.2
  • 5
    • 79953675058 scopus 로고    scopus 로고
    • Peri-implant bone tissue assessment by comparing the outcome of intra-oral radiograph and cone beam computed tomography analyses to the histological standard
    • doi:10.1111/j.1600-0501.2010.02029.x
    • Corpas Ldos S, Jacobs R, Quirynen M, Huang Y, Naert I, Duyck J (2011) Peri-implant bone tissue assessment by comparing the outcome of intra-oral radiograph and cone beam computed tomography analyses to the histological standard. Clin Oral Implants Res 22(5): 492-499. doi: 10. 1111/j. 1600-0501. 2010. 02029. x.
    • (2011) Clin Oral Implants Res , vol.22 , Issue.5 , pp. 492-499
    • Corpas Ldos, S.1    Jacobs, R.2    Quirynen, M.3    Huang, Y.4    Naert, I.5    Duyck, J.6
  • 6
    • 79959681674 scopus 로고    scopus 로고
    • Thickness of the anterior maxillary facial bone wall-a retrospective radiographic study using cone beam computed tomography
    • Braut V, Bornstein MM, Belser U, Buser D (2011) Thickness of the anterior maxillary facial bone wall-a retrospective radiographic study using cone beam computed tomography. Int J Periodontics Restorative Dent 31(2): 125-131.
    • (2011) Int J Periodontics Restorative Dent , vol.31 , Issue.2 , pp. 125-131
    • Braut, V.1    Bornstein, M.M.2    Belser, U.3    Buser, D.4
  • 7
    • 14544272069 scopus 로고    scopus 로고
    • Load transfer of miniscrews for orthodontic anchorage
    • Dalstra M, Cattaneo PM, Melsen B (2004) Load transfer of miniscrews for orthodontic anchorage. J Orthod 1: 53-62.
    • (2004) J Orthod , vol.1 , pp. 53-62
    • Dalstra, M.1    Cattaneo, P.M.2    Melsen, B.3
  • 8
    • 84857064711 scopus 로고    scopus 로고
    • Influence of two barrier membranes on staged guided bone regeneration and osseointegration of titanium implants in dogs. Part 2: augmentation using bone graft substitutes
    • Mihatovic I, Golubovic V, Hegewald A, Becker J, Schwarz F (2012) Influence of two barrier membranes on staged guided bone regeneration and osseointegration of titanium implants in dogs. Part 2: augmentation using bone graft substitutes. Clin Oral Implants Res 23: 308-315.
    • (2012) Clin Oral Implants Res , vol.23 , pp. 308-315
    • Mihatovic, I.1    Golubovic, V.2    Hegewald, A.3    Becker, J.4    Schwarz, F.5
  • 9
    • 84155164439 scopus 로고    scopus 로고
    • Influence of two barrier membranes on staged guided bone regeneration and osseointegration of titanium implants in dogs: part 1. Augmentation using bone graft substitutes and autogenous bone
    • doi: 10. 1111/j. 1600-0501. 2011. 02187. x
    • Schwarz F, Mihatovic I, Golubovic V, Hegewald A, Becker J (2011) Influence of two barrier membranes on staged guided bone regeneration and osseointegration of titanium implants in dogs: part 1. Augmentation using bone graft substitutes and autogenous bone. Clin Oral Implants Res. doi: 10. 1111/j. 1600-0501. 2011. 02187. x.
    • (2011) Clin Oral Implants Res
    • Schwarz, F.1    Mihatovic, I.2    Golubovic, V.3    Hegewald, A.4    Becker, J.5
  • 10
    • 0021845767 scopus 로고
    • The diagnostic value of the new method for the study of undecalcified bones and teeth with attached soft tissue (Sage-Schliff (sawing and grinding) technique)
    • Donath K (1985) The diagnostic value of the new method for the study of undecalcified bones and teeth with attached soft tissue (Sage-Schliff (sawing and grinding) technique). Pathol Res Pract 179(6): 631-633.
    • (1985) Pathol Res Pract , vol.179 , Issue.6 , pp. 631-633
    • Donath, K.1
  • 11
    • 67649408818 scopus 로고    scopus 로고
    • Accuracy and reliability of linear cephalometric measurements from cone-beam computed tomography scans of a dry human skull
    • discussion 17-18. doi: 10. 1016/j. ajodo. 2008. 08. 021
    • Berco M, Rigali PH, Jr., Miner RM, DeLuca S, Anderson NK, Will LA (2009) Accuracy and reliability of linear cephalometric measurements from cone-beam computed tomography scans of a dry human skull. Am J Orthod Dentofacial Orthop 136(1): 17 e11-19; discussion 17-18. doi: 10. 1016/j. ajodo. 2008. 08. 021.
    • (2009) Am J Orthod Dentofacial Orthop , vol.136 , Issue.1
    • Berco, M.1    Rigali Jr., P.H.2    Miner, R.M.3    DeLuca, S.4    Anderson, N.K.5    Will, L.A.6
  • 12
    • 72649103006 scopus 로고    scopus 로고
    • Accuracy of linear measurements from cone-beam computed tomography-derived surface models of different voxel sizes
    • discussion 16-17. doi: 10. 1016/j. ajodo. 2009. 06. 016
    • Damstra J, Fourie Z, Huddleston Slater JJ, Ren Y (2010) Accuracy of linear measurements from cone-beam computed tomography-derived surface models of different voxel sizes. Am J Orthod Dentofacial Orthop 137 (1): 16 e11-16; discussion 16-17. doi: 10. 1016/j. ajodo. 2009. 06. 016.
    • (2010) Am J Orthod Dentofacial Orthop , vol.137 , Issue.1
    • Damstra, J.1    Fourie, Z.2    Huddleston Slater, J.J.3    Ren, Y.4
  • 13
    • 77955884679 scopus 로고    scopus 로고
    • Multichannel computed tomography versus cone-beam computed tomography: linear accuracy of in vitro measurements of the maxilla for implant placement
    • Fatemitabar SA, Nikgoo A (2010) Multichannel computed tomography versus cone-beam computed tomography: linear accuracy of in vitro measurements of the maxilla for implant placement. Int J Oral Maxillofac Implants 25(3): 499-505.
    • (2010) Int J Oral Maxillofac Implants , vol.25 , Issue.3 , pp. 499-505
    • Fatemitabar, S.A.1    Nikgoo, A.2
  • 14
    • 2342419992 scopus 로고    scopus 로고
    • Accuracy in measurement of distance using limited cone-beam computerized tomography
    • Kobayashi K, Shimoda S, Nakagawa Y, Yamamoto A (2004) Accuracy in measurement of distance using limited cone-beam computerized tomography. Int J Oral Maxillofac Implants 19(2): 228-231.
    • (2004) Int J Oral Maxillofac Implants , vol.19 , Issue.2 , pp. 228-231
    • Kobayashi, K.1    Shimoda, S.2    Nakagawa, Y.3    Yamamoto, A.4
  • 15
    • 14244264415 scopus 로고    scopus 로고
    • Analysis of the accuracy of linear measurements obtained by cone beam computed tomography (CBCT-NewTom)
    • doi:10.1259/dmfr/25500850
    • Lascala CA, Panella J, Marques MM (2004) Analysis of the accuracy of linear measurements obtained by cone beam computed tomography (CBCT-NewTom). Dentomaxillofac Radiol 33(5): 291-294. doi: 10. 1259/dmfr/25500850.
    • (2004) Dentomaxillofac Radiol , vol.33 , Issue.5 , pp. 291-294
    • Lascala, C.A.1    Panella, J.2    Marques, M.M.3
  • 16
    • 33947515726 scopus 로고    scopus 로고
    • Accuracy of measurements of mandibular anatomy in cone beam computed tomography images
    • doi:10.1016/j.tripleo.2006.04.008
    • Ludlow JB, Laster WS, See M, Bailey LJ, Hershey HG (2007) Accuracy of measurements of mandibular anatomy in cone beam computed tomography images. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 103(4): 534-542. doi: 10. 1016/j. tripleo. 2006. 04. 008.
    • (2007) Oral Surg Oral Med Oral Pathol Oral Radiol Endod , vol.103 , Issue.4 , pp. 534-542
    • Ludlow, J.B.1    Laster, W.S.2    See, M.3    Bailey, L.J.4    Hershey, H.G.5
  • 17
    • 69249141096 scopus 로고    scopus 로고
    • Accuracy and precision of linear measurements in cone beam computed tomography Accuitomo tomograms obtained with different reconstruction techniques
    • doi:10.1259/dmfr/15022357
    • Lund H, Grondahl K, Grondahl HG (2009) Accuracy and precision of linear measurements in cone beam computed tomography Accuitomo tomograms obtained with different reconstruction techniques. Dentomaxillofac Radiol 38(6): 379-386. doi: 10. 1259/dmfr/15022357.
    • (2009) Dentomaxillofac Radiol , vol.38 , Issue.6 , pp. 379-386
    • Lund, H.1    Grondahl, K.2    Grondahl, H.G.3
  • 18
    • 33748518930 scopus 로고    scopus 로고
    • Accuracy of cone beam computed tomography for periodontal defect measurements
    • doi:10.1902/jop.2006.050367
    • Misch KA, Yi ES, Sarment DP (2006) Accuracy of cone beam computed tomography for periodontal defect measurements. J Periodontol 77(7): 1261-1266. doi: 10. 1902/jop. 2006. 050367.
    • (2006) J Periodontol , vol.77 , Issue.7 , pp. 1261-1266
    • Misch, K.A.1    Yi, E.S.2    Sarment, D.P.3
  • 20
    • 38949173479 scopus 로고    scopus 로고
    • Accuracy of linear measurements using dental cone beam and conventional multislice computed tomography
    • doi:10.1259/dmfr/14140281
    • Suomalainen A, Vehmas T, Kortesniemi M, Robinson S, Peltola J (2008) Accuracy of linear measurements using dental cone beam and conventional multislice computed tomography. Dentomaxillofac Radiol 37(1): 10-17. doi: 10. 1259/dmfr/14140281.
    • (2008) Dentomaxillofac Radiol , vol.37 , Issue.1 , pp. 10-17
    • Suomalainen, A.1    Vehmas, T.2    Kortesniemi, M.3    Robinson, S.4    Peltola, J.5
  • 21
    • 79955001088 scopus 로고    scopus 로고
    • Accuracy of linear measurement and the measurement limits of thin objects with cone beam computed tomography: effects of measurement directions and of phantom locations in the fields of view
    • Tsutsumi K, Chikui T, Okamura K, Yoshiura K (2011) Accuracy of linear measurement and the measurement limits of thin objects with cone beam computed tomography: effects of measurement directions and of phantom locations in the fields of view. Int J Oral Maxillofac Implants 26(1): 91-100.
    • (2011) Int J Oral Maxillofac Implants , vol.26 , Issue.1 , pp. 91-100
    • Tsutsumi, K.1    Chikui, T.2    Okamura, K.3    Yoshiura, K.4
  • 22
    • 55149112829 scopus 로고    scopus 로고
    • Accuracy of linear measurement provided by cone beam computed tomography to assess bone quantity in the posterior maxilla: a human cadaver study
    • doi:10.1111/j.1708-8208.2008.00083.x
    • Veyre-Goulet S, Fortin T, Thierry A (2008) Accuracy of linear measurement provided by cone beam computed tomography to assess bone quantity in the posterior maxilla: a human cadaver study. Clin Implant Dent Relat Res 10(4): 226-230. doi: 10. 1111/j. 1708-8208. 2008. 00083. x.
    • (2008) Clin Implant Dent Relat Res , vol.10 , Issue.4 , pp. 226-230
    • Veyre-Goulet, S.1    Fortin, T.2    Thierry, A.3
  • 23
    • 78751532284 scopus 로고    scopus 로고
    • A comparative study of the accuracy and reliability of multidetector computed tomography and cone beam computed tomography in the assessment of dental implant site dimensions
    • doi:10.1259/dmfr/27546065
    • Al-Ekrish AA, Ekram M (2011) A comparative study of the accuracy and reliability of multidetector computed tomography and cone beam computed tomography in the assessment of dental implant site dimensions. Dentomaxillofac Radiol 40(2): 67-75. doi: 10. 1259/dmfr/27546065.
    • (2011) Dentomaxillofac Radiol , vol.40 , Issue.2 , pp. 67-75
    • Al-Ekrish, A.A.1    Ekram, M.2
  • 25
    • 79955040862 scopus 로고    scopus 로고
    • Reliability and reproducibility of linear mandible measurements with the use of a cone-beam computed tomography and two object inclinations
    • doi:10.1259/dmfr/1742330
    • Tomasi C, Bressan E, Corazza B, Mazzoleni S, Stellini E, Lith A (2011) Reliability and reproducibility of linear mandible measurements with the use of a cone-beam computed tomography and two object inclinations. Dentomaxillofac Radiol 40(4): 244-250. doi: 10. 1259/dmfr/1742330.
    • (2011) Dentomaxillofac Radiol , vol.40 , Issue.4 , pp. 244-250
    • Tomasi, C.1    Bressan, E.2    Corazza, B.3    Mazzoleni, S.4    Stellini, E.5    Lith, A.6
  • 26
    • 68249095891 scopus 로고    scopus 로고
    • Enhancement of image quality with a fast iterative scatter and beam hardening correction method for kV CBCT
    • Reitz I, Hesse BM, Nill S, Tucking T, Oelfke U (2009) Enhancement of image quality with a fast iterative scatter and beam hardening correction method for kV CBCT. Z Med Phys 19(3): 158-172.
    • (2009) Z Med Phys , vol.19 , Issue.3 , pp. 158-172
    • Reitz, I.1    Hesse, B.M.2    Nill, S.3    Tucking, T.4    Oelfke, U.5
  • 27
    • 52049117425 scopus 로고    scopus 로고
    • What is cone-beam CT and how does it work?
    • doi:10.1016/j.cden.2008.05.005
    • Scarfe WC, Farman AG (2008) What is cone-beam CT and how does it work? Dent Clin North Am 52(4): 707-730. doi: 10. 1016/j. cden. 2008. 05. 005.
    • (2008) Dent Clin North Am , vol.52 , Issue.4 , pp. 707-730
    • Scarfe, W.C.1    Farman, A.G.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.