메뉴 건너뛰기




Volumn 21, Issue 7, 2010, Pages 718-725

Accuracy of measuring the cortical bone thickness adjacent to dental implants using cone beam computed tomography

Author keywords

Accuitomo 3D ; CBCT; Cortical bone; Dental implant; I CAT

Indexed keywords

ANIMAL; ARTICLE; BONE DENSITY; CATTLE; CONE BEAM COMPUTED TOMOGRAPHY; INSTRUMENTATION; JAW; PHYSIOLOGY; RADIOGRAPHY; REFERENCE VALUE; RIB; TOOTH IMPLANTATION; BOVINAE; DEVICES; SURGERY; TOOTH IMPLANT;

EID: 77954576900     PISSN: 09057161     EISSN: 16000501     Source Type: Journal    
DOI: 10.1111/j.1600-0501.2009.01905.x     Document Type: Article
Times cited : (150)

References (24)
  • 3
    • 34347238633 scopus 로고    scopus 로고
    • Beam hardening artefacts occur in dental implant scans with the NewTom cone beam CT but not with the dental 4-row multidetector CT
    • Draenert FG, Coppenrath E, Herzog P, Muller S, Mueller-Lisse UG. Beam hardening artefacts occur in dental implant scans with the NewTom cone beam CT but not with the dental 4-row multidetector CT. Dentomaxillofacial Radiology 2007, 36:198-203.
    • (2007) Dentomaxillofacial Radiology , vol.36 , pp. 198-203
    • Draenert, F.G.1    Coppenrath, E.2    Herzog, P.3    Muller, S.4    Mueller-Lisse, U.G.5
  • 6
    • 48649089199 scopus 로고    scopus 로고
    • Dosimetry of the cone beam computed tomography Veraviewepocs 3D compared with the 3D Accuitomo in different fields of view
    • Hirsch E, Wolf U, Heinicke F, Silva MA. Dosimetry of the cone beam computed tomography Veraviewepocs 3D compared with the 3D Accuitomo in different fields of view. Dentomaxillofacial Radiology 2008, 37:268-273.
    • (2008) Dentomaxillofacial Radiology , vol.37 , pp. 268-273
    • Hirsch, E.1    Wolf, U.2    Heinicke, F.3    Silva, M.A.4
  • 8
    • 14244264415 scopus 로고    scopus 로고
    • Analysis of the accuracy of linear measurements obtained by cone beam computed tomography (CBCT-NewTom)
    • Lascala CA, Panella J, Marques MM. Analysis of the accuracy of linear measurements obtained by cone beam computed tomography (CBCT-NewTom). Dentomaxillofacial Radiology 2004, 33:291-294.
    • (2004) Dentomaxillofacial Radiology , vol.33 , pp. 291-294
    • Lascala, C.A.1    Panella, J.2    Marques, M.M.3
  • 13
    • 0032240404 scopus 로고    scopus 로고
    • A new volumetric CT machine for dental imaging based on the cone-beam technique: preliminary results
    • Mozzo P, Procacci C, Tacconi A, Martini PT, Andreis IA. A new volumetric CT machine for dental imaging based on the cone-beam technique: preliminary results. European Journal of Radiology 1998, 8:1558-1564.
    • (1998) European Journal of Radiology , vol.8 , pp. 1558-1564
    • Mozzo, P.1    Procacci, C.2    Tacconi, A.3    Martini, P.T.4    Andreis, I.A.5
  • 16
    • 34547744324 scopus 로고    scopus 로고
    • Design, construction and evaluation of an anthropomorphic head phantom with realistic susceptibility artefacts
    • Shmueli K, Thomas DL, Ordidge RJ. Design, construction and evaluation of an anthropomorphic head phantom with realistic susceptibility artefacts. Journal of Magnetic Resonance Imaging 2007, 26:202-207.
    • (2007) Journal of Magnetic Resonance Imaging , vol.26 , pp. 202-207
    • Shmueli, K.1    Thomas, D.L.2    Ordidge, R.J.3
  • 17
    • 34249656423 scopus 로고    scopus 로고
    • Accuracy of cone beam dental CT, intraoral digital and conventional film radiography for the detection of periapical lesions. An ex vivo study in pig jaws
    • Stavropoulos A, Wenzel A. Accuracy of cone beam dental CT, intraoral digital and conventional film radiography for the detection of periapical lesions. An ex vivo study in pig jaws. Clinical Oral Investigation 2007, 11:101-106.
    • (2007) Clinical Oral Investigation , vol.11 , pp. 101-106
    • Stavropoulos, A.1    Wenzel, A.2
  • 19
    • 0642365211 scopus 로고    scopus 로고
    • Cone beam computed tomography in craniofacial imaging
    • Sukovic P. Cone beam computed tomography in craniofacial imaging. Orthodontics and Craniofacial Research 2003, 6((Suppl. 1)):31-36.
    • (2003) Orthodontics and Craniofacial Research , vol.6 , Issue.SUPPL. 1 , pp. 31-36
    • Sukovic, P.1
  • 20
    • 77954595166 scopus 로고    scopus 로고
    • Practice guideline for digital radiography
    • The American College of Radiology, (Res. 42), 18
    • Practice guideline for digital radiography. The American College of Radiology 2007, The American College of Radiology, (Res. 42), 18
    • (2007) The American College of Radiology
  • 21
    • 52049112120 scopus 로고    scopus 로고
    • Cone-beam CT diagnostic applications: caries, periodontal bone assessment, and endodontic applications
    • Tyndall DA, Rathore S. Cone-beam CT diagnostic applications: caries, periodontal bone assessment, and endodontic applications. Dental Clinics of North America 2008, 52:825-841, vii.
    • (2008) Dental Clinics of North America , vol.52 , pp. 825-841
    • Tyndall, D.A.1    Rathore, S.2
  • 22
    • 71849103328 scopus 로고    scopus 로고
    • Variable-resolution cone-beam computerized tomography with enhancement filtration compared with intraoral photostimulable phosphor radiography in detection of transverse root fractures in an in vitro model
    • Wenzel A, Haiter-Neto F, Frydenberg M, Kirkevang LL. Variable-resolution cone-beam computerized tomography with enhancement filtration compared with intraoral photostimulable phosphor radiography in detection of transverse root fractures in an in vitro model. Oral Surgery, Oral Medicine, Oral Pathology, Oral Radiology and Endodonology 2009, 108:939-945.
    • (2009) Oral Surgery, Oral Medicine, Oral Pathology, Oral Radiology and Endodonology , vol.108 , pp. 939-945
    • Wenzel, A.1    Haiter-Neto, F.2    Frydenberg, M.3    Kirkevang, L.L.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.