메뉴 건너뛰기




Volumn 40, Issue 2, 2011, Pages 67-75

A comparative study of the accuracy and reliability of multidetector computed tomography and cone beam computed tomography in the assessment of dental implant site dimensions

Author keywords

Cone beam CT; Dental implants; Reproducibility of results; Spiral CT

Indexed keywords


EID: 78751532284     PISSN: 0250832X     EISSN: None     Source Type: Journal    
DOI: 10.1259/dmfr/27546065     Document Type: Article
Times cited : (93)

References (21)
  • 1
    • 0032240404 scopus 로고    scopus 로고
    • A new volumetric CT machine for dental imaging based on the cone-beam technique: Preliminary results
    • Mozzo P, Procacci C, Tacconi A, Martini PT, Andreis IA. A new volumetric CT machine for dental imaging based on the cone-beam technique: preliminary results. Eur Radiol 1998; 8: 1558-1564.
    • (1998) Eur Radiol , vol.8 , pp. 1558-1564
    • Mozzo, P.1    Procacci, C.2    Tacconi, A.3    Martini, P.T.4    Andreis, I.A.5
  • 3
    • 4143136222 scopus 로고    scopus 로고
    • Characteristics of a newly developed dentomaxillofacial X-ray cone beam CT scanner (CB MercuRay): System configuration and physical properties
    • Araki K, Maki K, Seki K, Sakamaki K, Harata Y, Sakaino R, et al. Characteristics of a newly developed dentomaxillofacial X-ray cone beam CT scanner (CB MercuRay): system configuration and physical properties. Dentomaxillofac Radiol 2004; 33: 51-59.
    • (2004) Dentomaxillofac Radiol , vol.33 , pp. 51-59
    • Araki, K.1    Maki, K.2    Seki, K.3    Sakamaki, K.4    Harata, Y.5    Sakaino, R.6
  • 4
    • 0043194212 scopus 로고    scopus 로고
    • On the correlation of pixel noise, spatial resolution and dose in computed tomography: Theoretical prediction and verification by simulation and measurement
    • Fuchs T, Kalender WA. On the correlation of pixel noise, spatial resolution and dose in computed tomography: theoretical prediction and verification by simulation and measurement. Physica Medica 2003; 19: 153-164.
    • (2003) Physica Medica , vol.19 , pp. 153-164
    • Fuchs, T.1    Kalender, W.A.2
  • 7
    • 0038457603 scopus 로고    scopus 로고
    • The use of flat-panel detectors for CT imaging
    • Kalender WA. The use of flat-panel detectors for CT imaging. Radiology 2003; 43: 379-387.
    • (2003) Radiology , vol.43 , pp. 379-387
    • Kalender, W.A.1
  • 10
    • 38949173479 scopus 로고    scopus 로고
    • Accuracy of linear measurements using dental cone beam and conventional multislice computed tomography
    • Suomalainen A, Vehmas T, Kortesniemi M, Robinson S, Peltola J. Accuracy of linear measurements using dental cone beam and conventional multislice computed tomography. Dentomaxillofac Radiol 2008; 37: 10-17.
    • (2008) Dentomaxillofac Radiol , vol.37 , pp. 10-17
    • Suomalainen, A.1    Vehmas, T.2    Kortesniemi, M.3    Robinson, S.4    Peltola, J.5
  • 11
    • 0033032027 scopus 로고    scopus 로고
    • Three-dimensional computed tomography landmark measurement in craniofacial surgical planning: Experimental validation in vitro
    • Cavalcanti MG, Haller JW, Vannier MW. Three-dimensional computed tomography landmark measurement in craniofacial surgical planning: experimental validation in vitro. J Oral Maxillofac Surg 1999; 57: 690-694.
    • (1999) J Oral Maxillofac Surg , vol.57 , pp. 690-694
    • Cavalcanti, M.G.1    Haller, J.W.2    Vannier, M.W.3
  • 12
    • 2342425943 scopus 로고    scopus 로고
    • Measurement of mandibles with microfocus X-ray computerized tomography and compact computerized tomography for dental use
    • Naitoh M, Katsumata A, Mitsuya S, Kamemoto H, Ariji E. Measurement of mandibles with microfocus X-ray computerized tomography and compact computerized tomography for dental use. Int J Oral Maxillofac Implants 2004; 19: 239-246.
    • (2004) Int J Oral Maxillofac Implants , vol.19 , pp. 239-246
    • Naitoh, M.1    Katsumata, A.2    Mitsuya, S.3    Kamemoto, H.4    Ariji, E.5
  • 15
    • 14844348735 scopus 로고    scopus 로고
    • Computed tomography for dental implants: The influence of the gantry angle and mandibular positioning on the bone height and width
    • Dantas JA, Montebello Filho A, Campos PSF. Computed tomography for dental implants: the influence of the gantry angle and mandibular positioning on the bone height and width. Dentomaxillofac Radiol 2005; 34: 9-15.
    • (2005) Dentomaxillofac Radiol , vol.34 , pp. 9-15
    • Dantas, J.A.1    Montebello Filho, A.2    Campos, P.S.F.3
  • 17
    • 85036711201 scopus 로고    scopus 로고
    • radiology post-grad student E-mail to Asma Al-Ekrish
    • Naitoh M. Re: Questions from OMF; radiology post-grad student. E-mail to Asma Al-Ekrish. 8 April 2009.
    • (2009) Re: Questions from OMF
    • Naitoh, M.1
  • 18
    • 0034086714 scopus 로고    scopus 로고
    • Cone-beam computed tomography with a flat-panel imager: Initial performance characterization
    • Jaffray DA, Siewerdsen JH. Cone-beam computed tomography with a flat-panel imager: initial performance characterization. Med Phys 2000; 27: 1311-1323.
    • (2000) Med Phys , vol.27 , pp. 1311-1323
    • Jaffray, D.A.1    Siewerdsen, J.H.2
  • 19
    • 12244262522 scopus 로고    scopus 로고
    • Physical principles, clinical applications, and quality control. Second edition. Philadelphia: W.B. Saunders
    • Seeram E. Computed tomography. Physical principles, clinical applications, and quality control. Second edition. Philadelphia: W.B. Saunders, 2001.
    • (2001) Computed Tomography
    • Seeram, E.1
  • 20
    • 0035110308 scopus 로고    scopus 로고
    • Cone-beam computed tomography with a flat-panel imager: Magnitude and effects of x-ray scatter
    • Siewerdsen JH, Jaffray DA. Cone-beam computed tomography with a flat-panel imager: magnitude and effects of x-ray scatter. Med Phys 2001; 28: 220-231.
    • (2001) Med Phys , vol.28 , pp. 220-231
    • Siewerdsen, J.H.1    Jaffray, D.A.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.