메뉴 건너뛰기




Volumn 29, Issue 7, 2013, Pages

Influence of substructure design, veneer application technique, and firing regime on the in vitro performance of molar zirconia crowns

Author keywords

Ceramics; Chipping; Fracture resistance; Substructure design; Veneering; Zirconia

Indexed keywords

ADHESIVELY BONDED; CERAMICS; CHIPPING; FAILURE FREQUENCY; LAYERING TECHNIQUES; MECHANICAL LOADING; SUBSTRUCTURE DESIGNS; VENEERING;

EID: 84878869633     PISSN: 01095641     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.dental.2013.04.011     Document Type: Article
Times cited : (49)

References (43)
  • 2
    • 77449113504 scopus 로고    scopus 로고
    • Randomized controlled clinical trial of zirconia-ceramic and metal-ceramic posterior fixed dental prostheses: A 3-year follow-up
    • I. Sailer, J. Gottnerb, S. Kanelb, and C.H.F. Hammerle Randomized controlled clinical trial of zirconia-ceramic and metal-ceramic posterior fixed dental prostheses: a 3-year follow-up International Journal of Prosthodontics 22 2009 553 560
    • (2009) International Journal of Prosthodontics , vol.22 , pp. 553-560
    • Sailer, I.1    Gottnerb, J.2    Kanelb, S.3    Hammerle, C.H.F.4
  • 3
    • 71049124440 scopus 로고    scopus 로고
    • Three-year clinical prospective evaluation of zirconia-based posterior fixed dental prostheses (FDPs)
    • F. Beuer, D. Edelhoff, W. Gernet, and J.A. Sorensen Three-year clinical prospective evaluation of zirconia-based posterior fixed dental prostheses (FDPs) Clinical Oral Investigations 13 2009 445 451
    • (2009) Clinical Oral Investigations , vol.13 , pp. 445-451
    • Beuer, F.1    Edelhoff, D.2    Gernet, W.3    Sorensen, J.A.4
  • 5
    • 84866734793 scopus 로고    scopus 로고
    • In vitro failure and fracture resistance of veneered and full-contour zirconia restorations
    • V. Preis, M. Behr, S. Hahnel, G. Handel, and M. Rosentritt In vitro failure and fracture resistance of veneered and full-contour zirconia restorations Journal of Dentistry 40 2012 921 928
    • (2012) Journal of Dentistry , vol.40 , pp. 921-928
    • Preis, V.1    Behr, M.2    Hahnel, S.3    Handel, G.4    Rosentritt, M.5
  • 6
    • 1842783267 scopus 로고    scopus 로고
    • Strength, fracture toughness and microstructure of a selection of all-ceramic materials. Part II. Zirconia-based dental ceramics
    • M. Guazzato, M. Albakry, S.P. Ringer, and M.V. Swain Strength, fracture toughness and microstructure of a selection of all-ceramic materials. Part II. Zirconia-based dental ceramics Dental Materials 20 2004 449 456
    • (2004) Dental Materials , vol.20 , pp. 449-456
    • Guazzato, M.1    Albakry, M.2    Ringer, S.P.3    Swain, M.V.4
  • 13
    • 70350059154 scopus 로고    scopus 로고
    • Influence of substructure design and spacer settings on the in vitro performance of molar zirconia crowns
    • M. Rosentritt, D. Steiger, M. Behr, G. Handel, and C. Kolbeck Influence of substructure design and spacer settings on the in vitro performance of molar zirconia crowns Journal of Dentistry 37 2009 978 983
    • (2009) Journal of Dentistry , vol.37 , pp. 978-983
    • Rosentritt, M.1    Steiger, D.2    Behr, M.3    Handel, G.4    Kolbeck, C.5
  • 14
    • 13444311681 scopus 로고    scopus 로고
    • The influence of design parameters on the FEA-determined stress distribution in CAD-CAM produced all-ceramic dental crowns
    • N. De Jager, P. Pallav, and A.J. Feilzer The influence of design parameters on the FEA-determined stress distribution in CAD-CAM produced all-ceramic dental crowns Dental Materials 21 2005 242 251
    • (2005) Dental Materials , vol.21 , pp. 242-251
    • De Jager, N.1    Pallav, P.2    Feilzer, A.J.3
  • 15
    • 33746623731 scopus 로고    scopus 로고
    • Microtensile bond strength of different components of core veneered all-ceramic restorations. Part II. Zirconia veneering ceramics
    • M.N. Aboushelib, C.J. Kleverlaan, and A.J. Feilzer Microtensile bond strength of different components of core veneered all-ceramic restorations. Part II. Zirconia veneering ceramics Dental Materials 22 2006 857 863
    • (2006) Dental Materials , vol.22 , pp. 857-863
    • Aboushelib, M.N.1    Kleverlaan, C.J.2    Feilzer, A.J.3
  • 16
    • 60449083274 scopus 로고    scopus 로고
    • Impact of thermal misfit on shear strength of veneering ceramic/zirconia composites
    • J. Fischer, B. Stawarzcyk, A. Trottmann, and C.H.F. Hämmerle Impact of thermal misfit on shear strength of veneering ceramic/zirconia composites Dental Materials 25 2009 419 423
    • (2009) Dental Materials , vol.25 , pp. 419-423
    • Fischer, J.1    Stawarzcyk, B.2    Trottmann, A.3    Hämmerle, C.H.F.4
  • 17
    • 78049302564 scopus 로고    scopus 로고
    • Effect of firing protocols on cohesive failure of all-ceramic crowns
    • S. Rues, E. Kröger, D. Müller, and M. Schmitter Effect of firing protocols on cohesive failure of all-ceramic crowns Journal of Dentistry 38 2010 987 994
    • (2010) Journal of Dentistry , vol.38 , pp. 987-994
    • Rues, S.1    Kröger, E.2    Müller, D.3    Schmitter, M.4
  • 22
    • 30344459124 scopus 로고    scopus 로고
    • Influence of stress simulation parameters on the fracture strength of all-ceramic fixed-partial dentures
    • M. Rosentritt, M. Behr, R. Gebhard, and G. Handel Influence of stress simulation parameters on the fracture strength of all-ceramic fixed-partial dentures Dental Materials 22 2006 176 182
    • (2006) Dental Materials , vol.22 , pp. 176-182
    • Rosentritt, M.1    Behr, M.2    Gebhard, R.3    Handel, G.4
  • 23
    • 59149092803 scopus 로고    scopus 로고
    • Bridging the gap between clinical failure and laboratory fracture strength tests using a fractographic approach
    • M.N. Aboushelib, A.J. Feilzer, and C.J. Kleverlaan Bridging the gap between clinical failure and laboratory fracture strength tests using a fractographic approach Dental Materials 25 2009 383 391
    • (2009) Dental Materials , vol.25 , pp. 383-391
    • Aboushelib, M.N.1    Feilzer, A.J.2    Kleverlaan, C.J.3
  • 24
    • 25144475575 scopus 로고    scopus 로고
    • Fractographic analyses of three ceramic whole crown restoration failures
    • J.B. Quinn, G.D. Quinn, J.R. Kelly, and S.S. Scherrer Fractographic analyses of three ceramic whole crown restoration failures Dental Materials 21 2005 920 929
    • (2005) Dental Materials , vol.21 , pp. 920-929
    • Quinn, J.B.1    Quinn, G.D.2    Kelly, J.R.3    Scherrer, S.S.4
  • 26
    • 82255196468 scopus 로고    scopus 로고
    • Influence of resilient support of abutment teeth on fracture resistance of all-ceramic fixed partial dentures: An in vitro study
    • M. Rosentritt, M. Behr, P. Scharnagl, G. Handel, and C. Kolbeck Influence of resilient support of abutment teeth on fracture resistance of all-ceramic fixed partial dentures: an in vitro study International Journal of Prosthodontics 24 2011 465 468
    • (2011) International Journal of Prosthodontics , vol.24 , pp. 465-468
    • Rosentritt, M.1    Behr, M.2    Scharnagl, P.3    Handel, G.4    Kolbeck, C.5
  • 28
    • 80955143717 scopus 로고    scopus 로고
    • Influence of the fabrication process on the in vitro performance of fixed dental prostheses with zirconia substructures
    • M. Rosentritt, C. Kolbeck, G. Handel, S. Schneider-Feyrer, and M. Behr Influence of the fabrication process on the in vitro performance of fixed dental prostheses with zirconia substructures Clinical Oral Investigations 15 2011 1007 1012
    • (2011) Clinical Oral Investigations , vol.15 , pp. 1007-1012
    • Rosentritt, M.1    Kolbeck, C.2    Handel, G.3    Schneider-Feyrer, S.4    Behr, M.5
  • 29
    • 0034280714 scopus 로고    scopus 로고
    • In vitro fracture force and marginal adaptation of ceramic crowns fixed on natural and artificial teeth
    • M. Rosentritt, T. Plein, C. Kolbeck, M. Behr, and G. Handel In vitro fracture force and marginal adaptation of ceramic crowns fixed on natural and artificial teeth International Journal of Prosthodontics 13 2000 387 391
    • (2000) International Journal of Prosthodontics , vol.13 , pp. 387-391
    • Rosentritt, M.1    Plein, T.2    Kolbeck, C.3    Behr, M.4    Handel, G.5
  • 31
    • 0036580140 scopus 로고    scopus 로고
    • Potential countersample materials for in vitro simulation wear testing
    • A.C. Shortall, X.Q. Hu, and P.M. Marquis Potential countersample materials for in vitro simulation wear testing Dental Materials 18 2002 246 254
    • (2002) Dental Materials , vol.18 , pp. 246-254
    • Shortall, A.C.1    Hu, X.Q.2    Marquis, P.M.3
  • 33
    • 34250185998 scopus 로고    scopus 로고
    • Effect of loading method on the fracture mechanics of two layered all-ceramic restorative systems
    • M.N. Aboushelib, N. De Jager, C.J. Kleverlaan, and A.J. Feilzer Effect of loading method on the fracture mechanics of two layered all-ceramic restorative systems Dental Materials 23 2007 952 959
    • (2007) Dental Materials , vol.23 , pp. 952-959
    • Aboushelib, M.N.1    De Jager, N.2    Kleverlaan, C.J.3    Feilzer, A.J.4
  • 34
    • 34548590390 scopus 로고    scopus 로고
    • Fractographic ceramic failure analysis using the replica technique
    • S.S. Scherrer, J.B. Quinn, G.D. Quinn, and H.W.A. Wiskott Fractographic ceramic failure analysis using the replica technique Dental Materials 23 2007 1397 1404
    • (2007) Dental Materials , vol.23 , pp. 1397-1404
    • Scherrer, S.S.1    Quinn, J.B.2    Quinn, G.D.3    Wiskott, H.W.A.4
  • 35
    • 70349647002 scopus 로고    scopus 로고
    • Confocal examination of subsurface cracking in ceramic materials
    • M.K. Etman Confocal examination of subsurface cracking in ceramic materials Journal of Prosthodontics 18 2009 550 559
    • (2009) Journal of Prosthodontics , vol.18 , pp. 550-559
    • Etman, M.K.1
  • 37
    • 0036497563 scopus 로고    scopus 로고
    • Sintering of dental porcelain: Effect of time and temperature on appearance and porosity
    • K.C. Cheung, and B.W. Darvell Sintering of dental porcelain: effect of time and temperature on appearance and porosity Dental Materials 18 2002 163 173
    • (2002) Dental Materials , vol.18 , pp. 163-173
    • Cheung, K.C.1    Darvell, B.W.2
  • 38
    • 57449084616 scopus 로고    scopus 로고
    • High-strength CAD/CAM-fabricated veneering material sintered to zirconia copings - A new fabrication mode for all-ceramic restorations
    • F. Beuer, J. Schweiger, M. Eichberger, H.F. Kappert, W. Gernet, and D. Edelhoff High-strength CAD/CAM-fabricated veneering material sintered to zirconia copings - a new fabrication mode for all-ceramic restorations Dental Materials 25 2009 121 128
    • (2009) Dental Materials , vol.25 , pp. 121-128
    • Beuer, F.1    Schweiger, J.2    Eichberger, M.3    Kappert, H.F.4    Gernet, W.5    Edelhoff, D.6
  • 39
    • 84855886848 scopus 로고    scopus 로고
    • Chipping behaviour of all-ceramic crowns with zirconia framework and CAD/CAM manufactured veneer
    • M. Schmitter, D. Mueller, and S. Rues Chipping behaviour of all-ceramic crowns with zirconia framework and CAD/CAM manufactured veneer Journal of Dentistry 40 2012 154 162
    • (2012) Journal of Dentistry , vol.40 , pp. 154-162
    • Schmitter, M.1    Mueller, D.2    Rues, S.3
  • 40
    • 0347480519 scopus 로고    scopus 로고
    • Finite element analysis of stresses in molars during clenching and mastication
    • B. Dejak, A. Młotkowski, and M. Romanowicz Finite element analysis of stresses in molars during clenching and mastication Journal of Prosthetic Dentistry 90 2003 591 597
    • (2003) Journal of Prosthetic Dentistry , vol.90 , pp. 591-597
    • Dejak, B.1    Młotkowski, A.2    Romanowicz, M.3
  • 42
    • 84870904589 scopus 로고    scopus 로고
    • Effect of veneering technique on the fracture resistance of zirconia fixed dental prostheses
    • M.S. Chaar, S. Witkowski, J.R. Strub, and W. Att Effect of veneering technique on the fracture resistance of zirconia fixed dental prostheses Journal of Oral Rehabilitation 40 2013 51 59
    • (2013) Journal of Oral Rehabilitation , vol.40 , pp. 51-59
    • Chaar, M.S.1    Witkowski, S.2    Strub, J.R.3    Att, W.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.