메뉴 건너뛰기




Volumn 405, Issue 9, 2013, Pages 2785-2797

Isotopic analyses by ICP-MS in clinical samples

Author keywords

Body fluids; Clinical samples; Inductively coupled plasma mass spectrometry; Isotope ratios; Tissues

Indexed keywords

CLINICAL SAMPLES; ENVIRONMENTAL EXPOSURE; INDUCTIVELY COUPLED PLASMA MASS SPECTROMETRIES (ICPMS); ISOTOPE ABUNDANCE RATIOS; ISOTOPE DILUTIONS; ISOTOPE RATIO; ISOTOPIC ANALYSIS; MIGRATION PATHWAY;

EID: 84876903934     PISSN: 16182642     EISSN: 16182650     Source Type: Journal    
DOI: 10.1007/s00216-012-6457-x     Document Type: Review
Times cited : (33)

References (168)
  • 1
    • 0032692841 scopus 로고    scopus 로고
    • The potential of ICP-MS for the simultaneous determination of trace elements in whole blood, plasma and serum
    • 1:CAS:528:DyaK1MXnvFCltbs%3D 10.1016/S0946-672X(99)80006-6
    • Krachler M, Irgolic KJ (1999) The potential of ICP-MS for the simultaneous determination of trace elements in whole blood, plasma and serum. J Trace Elements Med Biol 13:157-169
    • (1999) J Trace Elements Med Biol , vol.13 , pp. 157-169
    • Krachler, M.1    Irgolic, K.J.2
  • 2
    • 33845183396 scopus 로고
    • Isotope dilution mass spectrometry for accurate elemental analysis
    • 1:CAS:528:DyaL1MXisVWltrg%3D
    • Fassett JD, Paulsen PJ (1989) Isotope dilution mass spectrometry for accurate elemental analysis. Anal Chem 61:643A-649A
    • (1989) Anal Chem , vol.61
    • Fassett, J.D.1    Paulsen, P.J.2
  • 3
    • 0019765222 scopus 로고
    • Determination of selenium in biological materials by stable isotope dilution gas chromatography-mass spectrometry
    • 1:CAS:528:DyaL3MXlvVehsL4%3D 10.1021/ac00237a004
    • Reamer DC, Veillon C (1981) Determination of selenium in biological materials by stable isotope dilution gas chromatography-mass spectrometry. Anal Chem 53:2166-2169
    • (1981) Anal Chem , vol.53 , pp. 2166-2169
    • Reamer, D.C.1    Veillon, C.2
  • 5
    • 0030191015 scopus 로고    scopus 로고
    • Fundamental aspects of ion extraction in inductively coupled plasma mass spectrometry
    • DOI 10.1016/0584-8547(96)01506-6, PII S0584854796015066
    • Niu H, Houk RS (1996) Fundamental aspects of ion extraction in inductively coupled plasma mass spectrometry. Spectrochim Acta Part B 51:779-815 (Pubitemid 126355385)
    • (1996) Spectrochimica Acta - Part B Atomic Spectroscopy , vol.51 , Issue.8 PART B , pp. 779-815
    • Niu, H.1    Houk, R.S.2
  • 6
    • 37049084331 scopus 로고
    • Evaluation of ICP argon MS for simultaneous multi-element trace analysis in clinical chemistry
    • 1:CAS:528:DyaL1cXhtV2jur4%3D 10.1039/ja9880300265
    • Lyon TDB, Fell GS, Hutton RC, Eaton AN (1988) Evaluation of ICP argon MS for simultaneous multi-element trace analysis in clinical chemistry. J Anal At Spectrom 3:265-271
    • (1988) J Anal at Spectrom , vol.3 , pp. 265-271
    • Lyon, T.D.B.1    Fell, G.S.2    Hutton, R.C.3    Eaton, A.N.4
  • 7
    • 0000269934 scopus 로고
    • Biomedical applications of ICP-MS
    • Delves HT (1988) Biomedical applications of ICP-MS. Chem Br 9:1009-1012
    • (1988) Chem Br , vol.9 , pp. 1009-1012
    • Delves, H.T.1
  • 8
    • 0027521654 scopus 로고
    • Advances in inductively coupled plasma mass spectrometry: Human nutrition and toxicology
    • DOI 10.1016/0003-2670(93)85214-5
    • Barnes RM (1993) Advances in ICP-MS: human nutrition and toxicology. Anal Chim Acta 283:115-130 (Pubitemid 23340724)
    • (1993) Analytica Chimica Acta , vol.283 , Issue.1 , pp. 115-130
    • Barnes, R.M.1
  • 9
    • 0028383713 scopus 로고
    • Spectral interferences encountered in the analysis of biological materials by ICP-MS
    • 1:CAS:528:DyaK2cXktVCgsbo%3D 10.1039/ja9940900177
    • Vanhoe H, Goossens J, Moens L, Dams R (1994) Spectral interferences encountered in the analysis of biological materials by ICP-MS. J Anal At Spectrom 9:177-185
    • (1994) J Anal at Spectrom , vol.9 , pp. 177-185
    • Vanhoe, H.1    Goossens, J.2    Moens, L.3    Dams, R.4
  • 10
    • 0002859457 scopus 로고
    • Interference effects and their control in ICP-MS analysis of serum and saline solutions
    • 1:CAS:528:DyaK2MXkt1yns7Y%3D 10.1006/mchj.1995.1011
    • Gerotto M, Dell'Andrea E, Bortoli A, Marchiori M, Palonta M, Troncon A (1995) Interference effects and their control in ICP-MS analysis of serum and saline solutions. Microchim J 51:73-87
    • (1995) Microchim J , vol.51 , pp. 73-87
    • Gerotto, M.1    Dell'Andrea, E.2    Bortoli, A.3    Marchiori, M.4    Palonta, M.5    Troncon, A.6
  • 11
    • 0031452075 scopus 로고    scopus 로고
    • Minimizing interferences in the quantitative multielement analysis of trace elements in biological fluids by inductively coupled plasma mass spectrometry
    • Hsiung CS, Andrade JD, Costa R, Ash KO (1997) Minimizing interferences in the quantitative multielement analysis of trace elements in biological fluids by ICP-MS. Clin Chem 43:2303-2311 (Pubitemid 28022965)
    • (1997) Clinical Chemistry , vol.43 , Issue.12 , pp. 2303-2311
    • Hsiung, C.-S.1    Andrade, J.D.2    Costa, R.3    Ash, K.O.4
  • 12
    • 3242669585 scopus 로고    scopus 로고
    • Overcoming spectral overlap in isotopic analysis via single- and multi-collector ICP-mass spectrometry
    • DOI 10.1007/s00216-003-2175-8
    • Vanhaecke F, Moens L (2004) Overcoming spectral overlap in isotopic analysis via single- and multi-collector ICP-mass spectrometry. Anal Bioanal Chem 378:232-240 (Pubitemid 40890230)
    • (2004) Analytical and Bioanalytical Chemistry , vol.378 , Issue.2 , pp. 232-240
    • Vanhaecke, F.1    Moens, L.2
  • 13
    • 84876933912 scopus 로고    scopus 로고
    • The accurate analysis of trace metals in clinical samples using ICP-MS
    • Turner J, Fairman B, Harrington C (1998) The accurate analysis of trace metals in clinical samples using ICP-MS. VAM Bull Spring, pp 12-16
    • (1998) VAM Bull Spring , pp. 12-16
    • Turner, J.1    Fairman, B.2    Harrington, C.3
  • 15
    • 0034250699 scopus 로고    scopus 로고
    • Effect of collisional damping and reactions in a dynamic reaction cell on the precision of isotope ratio measurements
    • 1:CAS:528:DC%2BD3cXltF2ntb0%3D 10.1039/b000285m
    • Bandura DR, Baranov VI, Tanner SD (2000) Effect of collisional damping and reactions in a dynamic reaction cell on the precision of isotope ratio measurements. J Anal At Spectrom 15:921-928
    • (2000) J Anal at Spectrom , vol.15 , pp. 921-928
    • Bandura, D.R.1    Baranov, V.I.2    Tanner, S.D.3
  • 18
    • 0033879459 scopus 로고    scopus 로고
    • Use of Pt guard electrode in inductively coupled plasma sector field mass spectrometry: Advantages and limitations
    • DOI 10.1039/a906531h
    • Appelblad P, Rodushkin I, Baxter D (2000) The use of Pt guard electrode in inductively coupled plasma sector field mass spectrometry: advantages and limitations. J Anal At Spectrom 15:359-364 (Pubitemid 30596863)
    • (2000) Journal of analytical atomic spectrometry , vol.15 , Issue.4 , pp. 359-364
    • Appelblad, P.K.1    Rodushkin, I.2    Baxter, D.C.3
  • 20
    • 0000553488 scopus 로고
    • Definitive measurement methods
    • 10.1016/0584-8547(91)80160-5
    • Moody JR, Epstein MS (1991) Definitive measurement methods. Spectrochim Acta 46:1571-1575
    • (1991) Spectrochim Acta , vol.46 , pp. 1571-1575
    • Moody, J.R.1    Epstein, M.S.2
  • 21
    • 2942535804 scopus 로고    scopus 로고
    • Isotope-dilution ICP-MS for trace element determination and speciation: From a reference method to a routine method?
    • DOI 10.1007/s00216-003-2325-z
    • Heumann KG (2004) Isotope-dilution ICP-MS for trace element determination and speciation: from a reference method to a routine method? Anal Bioanal Chem 378:318-329 (Pubitemid 40890239)
    • (2004) Analytical and Bioanalytical Chemistry , vol.378 , Issue.2 , pp. 318-329
    • Heumann, K.G.1
  • 22
    • 0022309826 scopus 로고
    • Isotope-dilution mass spectrometry in clinical chemistry
    • 1:CAS:528:DyaL28Xht1Grs7g%3D 10.1016/S0065-2423(08)60272-3
    • DeLeenheer AP, Lefevere MF, Lambert WE, Colinet ES (1985) Isotope-dilution mass spectrometry in clinical chemistry. Adv Clin Chem 24:111-161
    • (1985) Adv Clin Chem , vol.24 , pp. 111-161
    • Deleenheer, A.P.1    Lefevere, M.F.2    Lambert, W.E.3    Colinet, E.S.4
  • 23
    • 0007617846 scopus 로고
    • Isotopic and nuclear analytical techniques in biological systems: A critical study. Part X. Elemental isotope dilution analysis with radioactive and stable isotopes
    • 1:CAS:528:DyaK2MXpvFShsr8%3D 10.1351/pac199567111943
    • Fassett JD (1995) Isotopic and nuclear analytical techniques in biological systems: a critical study. Part X. Elemental isotope dilution analysis with radioactive and stable isotopes. Pure Appl Chem 67:1943-1949
    • (1995) Pure Appl Chem , vol.67 , pp. 1943-1949
    • Fassett, J.D.1
  • 25
    • 84876891773 scopus 로고    scopus 로고
    • Isotope-dilution mass spectrometry for quantification of urinary active androgens separated by gas chromatography
    • 1:CAS:528:DC%2BC3MXjtlSntL4%3D 10.5478/MSL.2010.1.1.029
    • Lee SH, Choi MH, Lee WY, Chung BC (2010) Isotope-dilution mass spectrometry for quantification of urinary active androgens separated by gas chromatography. Mass Spectrom Lett 1:29-32
    • (2010) Mass Spectrom Lett , vol.1 , pp. 29-32
    • Lee, S.H.1    Choi, M.H.2    Lee, W.Y.3    Chung, B.C.4
  • 26
    • 0035311780 scopus 로고    scopus 로고
    • A comparison between quadrupole, double focusing and multicollector ICP-MS instruments: Part I. Evaluation of total combined uncertainty for lead isotope ratio measurements
    • DOI 10.1039/b006145j
    • Encinar JR, Alonso JIG, Sanz-Medel A, Main S, Turner PJ (2001) A comparison between quadrupole, double focusing and multicollector ICP-MS instruments. Part I. Evaluation of total combined uncertainty for lead isotope ratio measurement. J Anal At Spectrom 16:315-321 (Pubitemid 32366318)
    • (2001) Journal of Analytical Atomic Spectrometry , vol.16 , Issue.4 , pp. 315-321
    • Encinar, J.R.1    Alonso, J.I.G.2    Sanz-Medel, A.3    Main, S.4    Turner, P.J.5
  • 27
    • 0001331297 scopus 로고
    • The determination of lead in blood using isotope dilution inductively coupled plasma mass spectrometry
    • 1:CAS:528:DyaK2MXmtFemtbY%3D 10.1007/BF00322327
    • Murphy KE, Paulsen PJ (1995) The determination of lead in blood using isotope dilution inductively coupled plasma mass spectrometry. Fresenius J Anal Chem 352:203-208
    • (1995) Fresenius J Anal Chem , vol.352 , pp. 203-208
    • Murphy, K.E.1    Paulsen, P.J.2
  • 28
    • 0032682867 scopus 로고    scopus 로고
    • Determination of cadmium in environmental and biological reference materials using isotope dilution analysis with a double focusing ICP-MS: A comparison with quadrupole ICP-MS
    • 10.1039/a901753d
    • Mota JPV, Encinar JR, De La Campa MRF, Alonso JIG, Sanz-Medel A (1999) Determination of cadmium in environmental and biological reference materials using isotope dilution analysis with a double focusing ICP-MS: a comparison with quadrupole ICP-MS. J Anal At Spectrom 14:1467-1474
    • (1999) J. Anal at Spectrom , vol.14 , pp. 1467-1474
    • Mota, J.P.V.1    Encinar, J.R.2    De La Campa, M.R.F.3    Alonso, J.I.G.4    Sanz-Medel, A.5
  • 30
    • 0035872366 scopus 로고    scopus 로고
    • Development of isotope dilution cold vapor inductively coupled plasma mass spectrometry and its application to the certification of mercury in NIST standard reference materials
    • DOI 10.1021/ac0013002
    • Christopher SJ, Long SE, Rearick MS, Fassett JD (2001) Development of isotope dilution cold vapor inductively coupled plasma mass spectrometry and its application to the certification of mercury in NIST standard reference materials. Anal Chem 73:2190-2199 (Pubitemid 32880682)
    • (2001) Analytical Chemistry , vol.73 , Issue.10 , pp. 2190-2199
    • Christopher, S.J.1    Long, S.E.2    Rearick, M.S.3    Fassett, J.D.4
  • 31
    • 0242366712 scopus 로고    scopus 로고
    • Quantitative speciation of selenium in human serum by affinity chromatography coupled to post-column isotope dilution analysis ICP-MS
    • 10.1039/b305455a 1:CAS:528:DC%2BD3sXns1Cmsbo%3D
    • Reyes LH, Marchante-Gayon JM, Alonso JIG, Sanz-Medel A (2003) Quantitative speciation of selenium in human serum by affinity chromatography coupled to post-column isotope dilution analysis ICP-MS. J Anal At Spectrom 18:1210-1216
    • (2003) J Anal at Spectrom , vol.18 , pp. 1210-1216
    • Reyes, L.H.1    Marchante-Gayon, J.M.2    Alonso, J.I.G.3    Sanz-Medel, A.4
  • 32
    • 33847756340 scopus 로고    scopus 로고
    • On the certification of cadmium at trace and ultratrace levels in standard reference materials using ID ICP-MS
    • DOI 10.1007/s00216-006-0880-9, Biological and Environmental Reference Materials (BERM 10)
    • Murphy KE, Long SE, Vocke RD (2007) On the certification of cadmium at trace and ultratrace levels in standard reference materials using ID ICP-MS. Anal Bioanal Chem 387:2453-2461 (Pubitemid 46384962)
    • (2007) Analytical and Bioanalytical Chemistry , vol.387 , Issue.7 , pp. 2453-2461
    • Murphy, K.E.1    Long, S.E.2    Vocke, R.D.3
  • 34
    • 84876917423 scopus 로고    scopus 로고
    • The use of collision/reaction cell ICP-MS with isotope dilution to provide assigned values for Zn, Cu and Se in serum samples for a proficiency testing scheme
    • Turner J, Evans L, Hearn R, Taylor A (2007) The use of collision/reaction cell ICP-MS with isotope dilution to provide assigned values for Zn, Cu and Se in serum samples for a proficiency testing scheme. Agilent application note 5989-7429EN
    • (2007) Agilent Application Note 5989-7429EN
    • Turner, J.1    Evans, L.2    Hearn, R.3    Taylor, A.4
  • 35
    • 0032419920 scopus 로고    scopus 로고
    • Isotope ratio determination in Boron analysis
    • Sah R, Brown PH (1998) Isotope ratio determination in boron analysis. Biol Trace Elem Res 66:39-53 (Pubitemid 29093969)
    • (1998) Biological Trace Element Research , vol.66 , Issue.1-3 , pp. 39-53
    • Sah, R.N.1    Brown, P.H.2
  • 36
    • 0035543713 scopus 로고    scopus 로고
    • Determining picogram quantities of uranium in urine by isotope dilution inductively coupled plasma mass spectrometry. Comparison with α-spectrometry
    • DOI 10.1039/b107455e
    • Haldimann M, Baduraux M, Eastgate A, Froidevaux P, O'Donovan S, von Gunten D, Zoller O (2001) Determining picogram quantities of uranium in urine by isotope dilution inductively coupled plasma mass spectrometry. Comparison with α-spectrometry. J Anal At Spectrom 16:1364-1369 (Pubitemid 34026204)
    • (2001) Journal of Analytical Atomic Spectrometry , vol.16 , Issue.12 , pp. 1364-1369
    • Haldimann, M.1    Baduraux, M.2    Eastgate, A.3    Froidevaux, P.4    O'Donovan, S.5    Von Gunten, D.6    Zoller, O.7
  • 37
    • 39649121727 scopus 로고    scopus 로고
    • Comparing the precision of selenium isotope ratio measurements using collision cell and sector field inductively coupled plasma mass spectrometry
    • DOI 10.1016/j.talanta.2007.10.046, PII S0039914007007436
    • Elwaer N, Hintelmann H (2008) Comparing the precision of selenium isotope ratio measurements using collision cell and sector field inductively coupled plasma mass spectrometry. Talanta 75:205-214 (Pubitemid 351288758)
    • (2008) Talanta , vol.75 , Issue.1 , pp. 205-214
    • Elwaer, N.1    Hintelmann, H.2
  • 38
    • 69149093102 scopus 로고    scopus 로고
    • Comparison of clinical methods with isotope dilution inductively coupled plasma mass spectrometry for the new standard reference material 955c lead in caprine blood
    • 1:CAS:528:DC%2BD1MXhtVSlsrfE 10.1039/b903060c
    • Murphy KE, Guthrie WF, Vetter TW, Turk GC, Palmer CD, Lewis ME, Geraghty CM, Parsons PJ (2009) Comparison of clinical methods with isotope dilution inductively coupled plasma mass spectrometry for the new standard reference material 955c lead in caprine blood. J Anal At Spectrom 24:1170-1178
    • (2009) J Anal at Spectrom , vol.24 , pp. 1170-1178
    • Murphy, K.E.1    Guthrie, W.F.2    Vetter, T.W.3    Turk, G.C.4    Palmer, C.D.5    Lewis, M.E.6    Geraghty, C.M.7    Parsons, P.J.8
  • 39
    • 79952488061 scopus 로고    scopus 로고
    • Collision/reaction cell ICP-MS with shielded torch and sector field ICP-MS for the simultaneous determination of selenium isotopes in biological matrices
    • 1:CAS:528:DC%2BC3MXisVWqtbY%3D 10.1007/s12011-010-8677-2
    • Al-Saad KA, Amr MA, Helal AI (2011) Collision/reaction cell ICP-MS with shielded torch and sector field ICP-MS for the simultaneous determination of selenium isotopes in biological matrices. Biol Trace Elem Res 140:103-113
    • (2011) Biol Trace Elem Res , vol.140 , pp. 103-113
    • Al-Saad, K.A.1    Amr, M.A.2    Helal, A.I.3
  • 40
    • 0000289325 scopus 로고    scopus 로고
    • Boron determination - A review of analytical methods
    • Sah RN, Brown PH (1997) Boron determination - a review of analytical methods. Microchem J 56:285-304 (Pubitemid 127401804)
    • (1997) Microchemical Journal , vol.56 , Issue.3 , pp. 285-304
    • Sah, R.N.1    Brown, P.H.2
  • 41
    • 0036025841 scopus 로고    scopus 로고
    • Determination of molybdenum and enriched Mo stable isotope concentrations in human blood plasma by isotope dilution ICP-MS
    • 1:CAS:528:DC%2BD38Xms1eqtr8%3D 10.1039/b202250h
    • Keyes WR, Turnlund JR (2002) Determination of molybdenum and enriched Mo stable isotope concentrations in human blood plasma by isotope dilution ICP-MS. J Anal At Spectrom 17:1153-1156
    • (2002) J Anal at Spectrom , vol.17 , pp. 1153-1156
    • Keyes, W.R.1    Turnlund, J.R.2
  • 42
    • 0030129299 scopus 로고    scopus 로고
    • Determination of selected nickel isotopes in biological samples by inductively coupled plasma mass spectrometry with isotope dilution
    • Patriarca M, Lyon TDB, McGaw B, Fell GS (1996) Determination of selected nickel isotopes in biological samples by inductively coupled plasma mass spectrometry with isotope dilution. J Anal At Spectrom 11:297-302 (Pubitemid 126564554)
    • (1996) Journal of Analytical Atomic Spectrometry , vol.11 , Issue.4 , pp. 297-302
    • Patriarca, M.1    Lyon, T.D.B.2    McGaw, B.3    Fell, G.S.4
  • 43
    • 0034246126 scopus 로고    scopus 로고
    • Determination of 60 elements in whole blood by sector field ICP-MS
    • 1:CAS:528:DC%2BD3cXltF2ntbs%3D 10.1039/b003561k
    • Rodushkin I, Ödman F, Olofsson R, Axelsson MD (2000) Determination of 60 elements in whole blood by sector field ICP-MS. J Anal At Spectrom 15:937-944
    • (2000) J Anal at Spectrom , vol.15 , pp. 937-944
    • Rodushkin, I.1    Ödman, F.2    Olofsson, R.3    Axelsson, M.D.4
  • 44
    • 0041474704 scopus 로고    scopus 로고
    • Determination of methylmercury, ethylmercury, and inorganic mercury in mouse tissues, following administration of thimerosal, by species-specific isotope dilution GC-inductively coupled plasma-MS
    • DOI 10.1021/ac0342370
    • Qvarnström J, Lambertsson L, Havarinasab S, Hultman P, Frech W (2003) Determination of methylmercury, ethylmercury, and inorganic mercury in mouse tissues, following administration of thimerosal, by species-specific isotope dilution GC-inductively coupled plasma-MS. Anal Chem 75:4120-4124 (Pubitemid 37012543)
    • (2003) Analytical Chemistry , vol.75 , Issue.16 , pp. 4120-4124
    • Qvarnstrom, J.1    Lambertsson, L.2    Havarinasab, S.3    Hultman, P.4    Frech, W.5
  • 45
    • 33846023734 scopus 로고    scopus 로고
    • Methylmercury measurement in whole blood by isotope-dilution GC-ICPMS with 2 sample preparation methods
    • DOI 10.1373/clinchem.2007.072520
    • Baxter DC, Rodushkin I, Engström E, Klockare D, Waara H (2007) Methylmercury measurement in whole-blood by isotope-dilution GC-ICPMS with 2 sample preparation methods. Clin Chem 53:111-116 (Pubitemid 46047770)
    • (2007) Clinical Chemistry , vol.53 , Issue.1 , pp. 111-116
    • Baxter, D.C.1    Rodushkin, I.2    Engstrom, E.3    Klockare, D.4    Waara, H.5
  • 46
    • 67650725369 scopus 로고    scopus 로고
    • Comparative determination of methyl mercury in whole blood samples using GC-ICP-MS and GC-MS techniques
    • 1:CAS:528:DC%2BD1MXptVCitr0%3D 10.1016/j.jchromb.2009.06.004
    • Hippler J, Hoppe HW, Mosel F, Rettenmeier AW, Hirner AV (2009) Comparative determination of methyl mercury in whole blood samples using GC-ICP-MS and GC-MS techniques. J Chromatogr 877:2465-2470
    • (2009) J Chromatogr , vol.877 , pp. 2465-2470
    • Hippler, J.1    Hoppe, H.W.2    Mosel, F.3    Rettenmeier, A.W.4    Hirner, A.V.5
  • 48
    • 79960742571 scopus 로고    scopus 로고
    • Serum/plasma methylmercury determination by isotope dilution gas chromatography-inductively coupled plasma mass spectrometry
    • 1:CAS:528:DC%2BC3MXps1emsLc%3D 10.1016/j.aca.2011.06.012
    • Baxter DC, Faarinen M, Österlund H, Rodushkin I, Christensen M (2011) Serum/plasma methylmercury determination by isotope dilution gas chromatography-inductively coupled plasma mass spectrometry. Anal Chim Acta 701:134-138
    • (2011) Anal Chim Acta , vol.701 , pp. 134-138
    • Baxter, D.C.1    Faarinen, M.2    Österlund, H.3    Rodushkin, I.4    Christensen, M.5
  • 50
    • 77649216075 scopus 로고    scopus 로고
    • Recent advances in isotope dilution analysis for elemental speciation
    • 10.1039/b924261a 1:CAS:528:DC%2BC3cXitl2hsLs%3D
    • Rodríguez-González P, Alonso JIG (2010) Recent advances in isotope dilution analysis for elemental speciation. J Anal At Spectrom 25:239-259
    • (2010) J Anal at Spectrom , vol.25 , pp. 239-259
    • Rodríguez-González, P.1    Alonso, J.I.G.2
  • 51
    • 37649024769 scopus 로고    scopus 로고
    • Paradigms in isotope dilution mass spectrometry for elemental speciation analysis
    • 1:CAS:528:DC%2BD1cXlt1aksA%3D%3D 10.1016/j.aca.2007.11.050
    • Meija J, Mester Z (2008) Paradigms in isotope dilution mass spectrometry for elemental speciation analysis. Anal Chim Acta 607:115-125
    • (2008) Anal Chim Acta , vol.607 , pp. 115-125
    • Meija, J.1    Mester, Z.2
  • 52
    • 0036739097 scopus 로고    scopus 로고
    • Using stable isotopes and isotope ratio mass spectrometry to study mineral metabolism in humans
    • 1:CAS:528:DC%2BD38Xms1eqtr4%3D 10.1039/b202249b
    • Griffin IJ (2002) Using stable isotopes and isotope ratio mass spectrometry to study mineral metabolism in humans. J Anal At Spectrom 17:1186-1193
    • (2002) J Anal at Spectrom , vol.17 , pp. 1186-1193
    • Griffin, I.J.1
  • 53
    • 0036434048 scopus 로고    scopus 로고
    • Development of a high-resolution ICP-MS method, suitable for the measurement of iron and iron isotope ratios in acid digests of faecal samples from a human nutrition study
    • DOI 10.1039/b206211a
    • Ingle C, Langford N, Harvey L, Dainty JR, Armah C, Fairweather-Tait S, Sharp B, Crews H, Rose M, Lewis J (2002) Development of a high-resolution ICP-MS method, suitable for the measurements of iron and iron isotope ratios in acid digests of faecal samples from a human nutritional study. J Anal At Spectrom 17:1498-1501 (Pubitemid 35459179)
    • (2002) Journal of Analytical Atomic Spectrometry , vol.17 , Issue.11 , pp. 1498-1501
    • Ingle, C.1    Langford, N.2    Harvey, L.3    Dainty, J.R.4    Armah, C.5    Fairweather-Tait, S.6    Sharp, B.7    Crews, H.8    Rose, M.9    Lewis, J.10
  • 54
    • 0036433942 scopus 로고    scopus 로고
    • An ICP-MS methodology using a combined high-resolution/multi-collector detector system for the measurement of total zinc and zinc isotope ratios in faecal samples from a human nutrition study
    • DOI 10.1039/b206213e
    • Ingle C, Langford N, Harvey L, Dainty JR, Armah C, Fairweather-Tait S, Sharp B, Crews H, Rose M, Lewis J (2002) An ICP-MS methodology using a combined high-resolution/multi-collector detector system for the measurement of total zinc and zinc isotope ratios in faecal samples from a human nutritional study. J Anal At Spectrom 17:1502-1505 (Pubitemid 35459180)
    • (2002) Journal of Analytical Atomic Spectrometry , vol.17 , Issue.11 , pp. 1502-1505
    • Ingle, C.1    Langford, N.2    Harvey, L.3    Dainty, J.R.4    Armah, C.5    Fairweather-Tait, S.6    Sharp, B.7    Rose, M.8    Crews, H.9    Lewis, J.10
  • 55
    • 84876888866 scopus 로고    scopus 로고
    • Stable isotope methods for studying nrtrient mineral metabolism in humans
    • Mellon FA, Fairweather-Tait SJ (1997) Stable isotope methods for studying nutrient mineral metabolism in humans. Endeavour 2:212-218
    • (1997) Endeavour , vol.2 , pp. 212-218
    • Mellon, F.A.1    Fairweather-Tait, S.J.2
  • 56
    • 0343060897 scopus 로고    scopus 로고
    • Application of HR-ICP-MS for the simultaneous measurement of zinc isotope ratios and total zinc content in human samples
    • DOI 10.1039/a906207f
    • Stürup S (2000) Application of HR-ICP-MS for the simultaneous measurements of zinc isotope ratios and total zinc content in human samples. J Anal At Spectrom 15:315-321 (Pubitemid 30596870)
    • (2000) Journal of analytical atomic spectrometry , vol.15 , Issue.4 , pp. 315-321
    • Stump, S.1
  • 60
    • 66849087720 scopus 로고    scopus 로고
    • Methods of assessment of copper status in humans: A systematic review
    • 1:CAS:528:DC%2BD1MXms1ejs70%3D 10.3945/ajcn.2009.27230E
    • Harvey LJ, Ashton K, Hooper L, Casgrain A, Fairweather-Tait SJ (2009) Methods of assessment of copper status in humans: a systematic review. Am J Clin Nutr 89:2009S-2024S
    • (2009) Am J Clin Nutr , vol.89
    • Harvey, L.J.1    Ashton, K.2    Hooper, L.3    Casgrain, A.4    Fairweather-Tait, S.J.5
  • 62
    • 0000613079 scopus 로고    scopus 로고
    • Stable lead isotope characteristics of lead ore deposits of environmental significance
    • 1:CAS:528:DC%2BD3cXnsFGjsLs%3D 10.1139/a00-008
    • Sangster DF, Outridge PM, Davis WJ (2000) Stable lead isotope characteristics of lead ore deposits of environmental significance. Environ Rev 8:115-147
    • (2000) Environ Rev , vol.8 , pp. 115-147
    • Sangster, D.F.1    Outridge, P.M.2    Davis, W.J.3
  • 67
    • 14644396122 scopus 로고    scopus 로고
    • The effect of exposure to employees from mining and milling operations in a uranium mine on lead isotopes - A pilot study
    • DOI 10.1016/j.scitotenv.2004.11.006, PII S0048969704007429
    • Gulson BL, Mizon KJ, Dickson BL, Korsch MJ (2005) The effect of exposure to employees from mining and milling operations in a uranium mine on lead isotopes - a pilot study. Sci Total Environ 339:267-272 (Pubitemid 40312253)
    • (2005) Science of the Total Environment , vol.339 , Issue.1-3 , pp. 267-272
    • Gulson, B.L.1    Mizon, K.J.2    Dickson, B.L.3    Korsch, M.J.4
  • 69
    • 34247226621 scopus 로고    scopus 로고
    • Origin assignment of unidentified corpses by use of stable isotope ratios of light (bio-) and heavy (geo-) elements-A case report
    • DOI 10.1016/j.forsciint.2006.02.011, PII S0379073806000661
    • Rauch E, Rummel S, Lehn C, Büttner A (2007) Origin assignment of unidentified corpses by use of stable isotope ratios of light (bio-) and heavy (geo-) elements - a case report. Forensic Sci Int 168:215-218 (Pubitemid 46617837)
    • (2007) Forensic Science International , vol.168 , Issue.2-3 , pp. 215-218
    • Rauch, E.1    Rummel, S.2    Lehn, C.3    Buttner, A.4
  • 70
    • 0001155265 scopus 로고
    • Measurements of total lead concentrations and of lead isotope ratios in whole blood by use of ICP-MS
    • 1:CAS:528:DyaL1cXhsVCrsLc%3D 10.1039/ja9880300343
    • Delves HT, Campbell MJ (1988) Measurements of total lead concentrations and of lead isotope ratios in whole blood by use of ICP-MS. J Anal At Spectrom 3:343-348
    • (1988) J Anal at Spectrom , vol.3 , pp. 343-348
    • Delves, H.T.1    Campbell, M.J.2
  • 71
    • 0000476266 scopus 로고
    • Accurate and precise determination of lead isotope ratios in clinical and environmental samples using ICP-MS
    • 1:CAS:528:DyaL1MXmsVOjsrk%3D 10.1039/ja9890400235
    • Campbell MJ, Delves HT (1989) Accurate and precise determination of lead isotope ratios in clinical and environmental samples using ICP-MS. J Anal At Spectrom 4:235-236
    • (1989) J Anal at Spectrom , vol.4 , pp. 235-236
    • Campbell, M.J.1    Delves, H.T.2
  • 72
    • 0001427376 scopus 로고
    • Identification of potential environmental sources of childhood lead poisoning by ICP-MS. Verification and case studies
    • 1:CAS:528:DyaK3cXktlGqurk%3D 10.1039/ja9900500293
    • Viczian M, Lasztity A, Barnes RM (1990) Identification of potential environmental sources of childhood lead poisoning by ICP-MS. Verification and case studies. J Anal At Spectrom 5:293-300
    • (1990) J Anal at Spectrom , vol.5 , pp. 293-300
    • Viczian, M.1    Lasztity, A.2    Barnes, R.M.3
  • 73
    • 0029690068 scopus 로고    scopus 로고
    • Isotope ratio analysis of lead in biological materials by inductively coupled plasma mass spectrometry
    • Yoshinaga J (1996) Isotope ratio analysis of lead in biological materials by inductively coupled plasma mass spectrometry. Tohoku J Exp Med 178:37-47 (Pubitemid 126542980)
    • (1996) Tohoku Journal of Experimental Medicine , vol.178 , Issue.1 , pp. 37-47
    • Yoshinaga, J.1
  • 74
    • 17144468984 scopus 로고
    • Childhood soil ingestion: How much dirt do kids eat?
    • 10.1021/ac00222a026
    • Barnes RR (1990) Childhood soil ingestion: How much dirt do kids eat? Anal Chem 62:A1023-A1026
    • (1990) Anal Chem , vol.62
    • Barnes, R.R.1
  • 76
    • 0028122822 scopus 로고
    • History of lead exposure in children revealed from isotopic analyses of teeth
    • Gulson B, Wilson D (1994) History of lead exposure in children revealed from isotopic analyses of teeth. Arch Environ Health 49:279-283 (Pubitemid 24235370)
    • (1994) Archives of Environmental Health , vol.49 , Issue.4 , pp. 279-283
    • Gulson, B.1    Wilson, D.2
  • 78
    • 0001283448 scopus 로고    scopus 로고
    • Precise measurement of isotope ratios with a double-focusing magnetic sector ICP mass spectrometer
    • Vanhaecke F, Moens L, Dams R, Taylor P (1996) Precise measurement of isotope ratios with a double-focusing magnetic sector ICP mass spectrometer. Anal Chem 76:567-569 (Pubitemid 126681734)
    • (1996) Analytical Chemistry , vol.68 , Issue.3 , pp. 567-569
    • Vanhaecke, F.1
  • 79
    • 0033665184 scopus 로고    scopus 로고
    • Lead isotopes as a supplementary tool in the routine evaluation of household hazards
    • 1:CAS:528:DC%2BD3cXos1yks7o%3D
    • Gwiazda RH, Smith DR (2000) Lead isotopes as a supplementary tool in the routine evaluation of household hazards. Environ Health Perspect 108:1091-1097
    • (2000) Environ Health Perspect , vol.108 , pp. 1091-1097
    • Gwiazda, R.H.1    Smith, D.R.2
  • 80
    • 39749148966 scopus 로고    scopus 로고
    • The identification of lead ammunition as a source of lead exposure in first nations: The use of lead isotope ratios
    • 1:CAS:528:DC%2BD1cXivVejtrY%3D 10.1016/j.scitotenv.2008.01.022
    • Tsuji LJS, Wainman BC, Martin ID, Sutherland C, Weber JP, Dumas P, Nieboer E (2008) The identification of lead ammunition as a source of lead exposure in First Nations: the use of lead isotope ratios. Sci Total Environ 393:291-298
    • (2008) Sci Total Environ , vol.393 , pp. 291-298
    • Tsuji, L.J.S.1    Wainman, B.C.2    Martin, I.D.3    Sutherland, C.4    Weber, J.P.5    Dumas, P.6    Nieboer, E.7
  • 82
    • 0032167075 scopus 로고    scopus 로고
    • Inductively coupled plasma magnetic sector mass spectrometry method for stable lead isotope tracer studies
    • Woolard D, Franks R, Smith DR (1998) Inductively coupled plasma magnetic sector mass spectrometry method for stable isotope tracer studies. J Anal At Spectrom 13:1015-1019 (Pubitemid 128593957)
    • (1998) Journal of Analytical Atomic Spectrometry , vol.13 , Issue.9 , pp. 1015-1019
    • Woolard, D.1    Franks, R.2    Smith, D.R.3
  • 83
    • 0032206414 scopus 로고    scopus 로고
    • Improved lead isotope ratio measurements in environmental and biological samples with a double focussing magnetic sector inductively coupled plasma mass spectrometer (ICP-MS)
    • Gwiazda R, Woolard D, Smith D (1998) Improved lead isotope ratio measurements in environmental and biological samples with a double focusing magnetic sector inductively coupled mass spectrometer (ICP-MS). J Anal At Spectrom 13:1233-1238 (Pubitemid 128600387)
    • (1998) Journal of Analytical Atomic Spectrometry , vol.13 , Issue.11 , pp. 1233-1238
    • Gwiazda, R.1    Woolard, D.2    Smith, D.3
  • 84
    • 12744279380 scopus 로고    scopus 로고
    • A noninvasive isotopic approach to estimate the bone lead contribution to blood in children: Implications for assessing the efficacy of lead abatement
    • 1:CAS:528:DC%2BD2MXhtFCqu7s%3D 10.1289/ehp.7241
    • Gwiazda RH, Campbell C, Smith D (2005) A noninvasive isotopic approach to estimate the bone lead contribution to blood in children: implications for assessing the efficacy of lead abatement. Environ Health Perspect 113:104-110
    • (2005) Environ Health Perspect , vol.113 , pp. 104-110
    • Gwiazda, R.H.1    Campbell, C.2    Smith, D.3
  • 85
    • 0034735713 scopus 로고    scopus 로고
    • Application of double focusing sector field ICP-MS for multielemental characterization of human hair and nails. Part II. A study of the inhabitants of northern Sweden
    • 1:CAS:528:DC%2BD3cXmslKktb4%3D 10.1016/S0048-9697(00)00531-3
    • Rodushkin I, Axelsson MD (2000) Application of double focusing sector field ICP-MS for multielemental characterization of human hair and nails. Part II. A study of the inhabitants of northern Sweden. Sci Total Environ 262:21-36
    • (2000) Sci Total Environ , vol.262 , pp. 21-36
    • Rodushkin, I.1    Axelsson, M.D.2
  • 86
    • 78651244008 scopus 로고    scopus 로고
    • Isotope ratio analysis of lead in blood and environmental samples by multi-collector inductively coupled plasma mass spectrometry
    • 1:CAS:528:DC%2BC3MXhsFWmtbw%3D 10.2116/analsci.27.29
    • Takagi M, Yoshinaga J, Tanaka A, Seyama H (2011) Isotope ratio analysis of lead in blood and environmental samples by multi-collector inductively coupled plasma mass spectrometry. Anal Sci 27:29-35
    • (2011) Anal Sci , vol.27 , pp. 29-35
    • Takagi, M.1    Yoshinaga, J.2    Tanaka, A.3    Seyama, H.4
  • 87
    • 48249124665 scopus 로고    scopus 로고
    • High-precision Pb isotopic measurements of teeth and environmental samples from Sofia (Bulgaria): Insights for regional lead sources and possible pathways to the human body
    • 1:CAS:528:DC%2BD1cXosVGhur4%3D 10.1007/s00254-007-1017-y
    • Kamenov GD (2008) High-precision Pb isotopic measurements of teeth and environmental samples from Sofia (Bulgaria): insights for regional lead sources and possible pathways to the human body. Environ Geol 55:669-680
    • (2008) Environ Geol , vol.55 , pp. 669-680
    • Kamenov, G.D.1
  • 89
    • 28844432636 scopus 로고    scopus 로고
    • Changes in the lead isotopic composition of blood, diet and air in Australia over a decade: Globalization and implications for future isotopic studies
    • DOI 10.1016/j.envres.2005.03.006, PII S0013935105000332
    • Gulson B, Mizon K, Korsch M, Taylor A (2006) Changes in the lead isotopic composition of blood, diet and air in Australia over a decade: globalization and implications for future isotopic studies. Environ Res 100:130-138 (Pubitemid 41767731)
    • (2006) Environmental Research , vol.100 , Issue.1 , pp. 130-138
    • Gulson, B.1    Mizon, K.2    Korsch, M.3    Taylor, A.4
  • 91
    • 60749104149 scopus 로고    scopus 로고
    • Megaliths and mobility in south-western Sweden. Investigating relationships between a local society and its neighbors using strontium isotopes
    • 10.1016/j.jaa.2008.10.001
    • Sjögren KG, Price TD, Ahlström T (2009) Megaliths and mobility in south-western Sweden. Investigating relationships between a local society and its neighbors using strontium isotopes. J Anthropol Archaeol 28:85-101
    • (2009) J Anthropol Archaeol , vol.28 , pp. 85-101
    • Sjögren, K.G.1    Price, T.D.2    Ahlström, T.3
  • 92
    • 0032099117 scopus 로고    scopus 로고
    • Strontium isotope ratio measurements in prehistoric human bone samples by means of high-resolution inductively coupled plasma mass spectrometry (HR-ICP-MS)
    • Latkoczy C, Prohaska T, Stingeder G, Teschler-Nicola M (1998) Strontium isotope ratio measurements in prehistoric human bone samples by means of high-resolution inductively coupled plasma mass spectrometry (HR-ICP-MS). J Anal At Spectrom 13:561-566 (Pubitemid 128592423)
    • (1998) Journal of Analytical Atomic Spectrometry , vol.13 , Issue.6 , pp. 561-566
    • Latkoczy, C.1    Prohaska, T.2    Stingeder, G.3    Teschler-Nicola, M.4
  • 93
    • 0035982135 scopus 로고    scopus 로고
    • Investigation of Sr isotope ratios in prehistoric human bones and teeth using laser ablation ICP-MS and ICP-MS after Rb/Sr separation
    • DOI 10.1039/b203314c
    • Prohaska T, Latkoczy C, Schultheis G, Teschler-Nicola M, Stingeder G (2002) Investigation of Sr isotope ratios in prehistoric human bones and teeth using laser ablation ICP-MS and ICP-MS after Rb/Sr separation. J Anal At Spectrom 17:887-891 (Pubitemid 34993079)
    • (2002) Journal of Analytical Atomic Spectrometry , vol.17 , Issue.8 , pp. 887-891
    • Prohaska, T.1    Latkoczy, C.2    Schultheis, G.3    Teschler-Nicola, M.4    Stingeder, G.5
  • 94
    • 7044264837 scopus 로고    scopus 로고
    • Isotope and trace element analysis of human teeth and bones for forensic purposes
    • Pye K (2004) Isotope and trace element analysis of human teeth and bones for forensic purposes. In: Pye K, Croft DJ (eds) Forensic geoscience. Principles, techniques and applications. Geological Society of London special publication no 232. Geological Society Publishing House, Bath, pp 215-236 (Pubitemid 39428628)
    • (2004) Geological Society Special Publication , Issue.232 , pp. 215-236
    • Pye, K.1
  • 95
    • 21244434382 scopus 로고    scopus 로고
    • Isotope-abundance ratios of light (bio) and heavy (geo) elements in biogenic tissues: Methods and applications
    • DOI 10.1007/s00216-003-2203-8
    • Hölzl S, Horn P, Rossmann A, Rummel S (2004) Isotope-abundance ratios of light (bio) and heavy (geo) elements in biogenic tissues: methods and applications. Anal Bioanal Chem 378:270-272 (Pubitemid 40890234)
    • (2004) Analytical and Bioanalytical Chemistry , vol.378 , Issue.2 , pp. 270-272
    • Holzl, S.1    Horn, P.2    Rossmann, A.3    Rummel, S.4
  • 96
    • 77957166455 scopus 로고    scopus 로고
    • Determination of isotope ratios of metals (and metalloids) by means of inductively coupled plasma-mass spectrometry for provenancing purposes - A review
    • Balcaen L, Moens L, Vanhaecke F. Determination of isotope ratios of metals (and metalloids) by means of inductively coupled plasma-mass spectrometry for provenancing purposes - a review. Spectrochim Acta Part B 65:769-786
    • Spectrochim Acta Part B , vol.65 , pp. 769-786
    • Balcaen, L.1    Moens, L.2    Vanhaecke, F.3
  • 97
    • 0242443929 scopus 로고    scopus 로고
    • Undiagnosed illnesses and radioactive warfare
    • Durakovic A (2003) Undiagnosed illnesses and radioactive warfare. Croatian Med J 44:520-532 (Pubitemid 37392132)
    • (2003) Croatian Medical Journal , vol.44 , Issue.5 , pp. 520-532
    • Durakovic, A.1
  • 98
    • 84876932601 scopus 로고    scopus 로고
    • Analysis of uranium in urine using ICP-MS
    • Bakowska E, Gluodenis TJ (1999) Analysis of uranium in urine using ICP-MS. Am Clin Lab 10:14-15
    • (1999) Am Clin Lab , vol.10 , pp. 14-15
    • Bakowska, E.1    Gluodenis, T.J.2
  • 99
    • 77949721020 scopus 로고    scopus 로고
    • Method development for ultra-trace quantification and isotope ratio measurement of uranium in urine
    • 1:CAS:528:DC%2BD2cXmtVSitbc%3D
    • Morton J, Nelms M (2004) Method development for ultra-trace quantification and isotope ratio measurement of uranium in urine. Spectrosc Eur 16:20-22
    • (2004) Spectrosc Eur , vol.16 , pp. 20-22
    • Morton, J.1    Nelms, M.2
  • 100
    • 65549124663 scopus 로고    scopus 로고
    • Uranium isotope ratio determination in urine using flow-injection ICP-MS: A tool for emergency monitoring
    • 1:CAS:528:DC%2BD1MXlt1CksLs%3D 10.1093/rpd/ncp027
    • Godoy MLDP, Juliao LMQC, Godoy JM (2009) Uranium isotope ratio determination in urine using flow-injection ICP-MS: a tool for emergency monitoring. Radiat Prot Dosim 133:234-239
    • (2009) Radiat Prot Dosim , vol.133 , pp. 234-239
    • Godoy, M.1    Juliao, L.2    Godoy, J.M.3
  • 101
    • 0037026860 scopus 로고    scopus 로고
    • Determination of 235U and 238U in urine samples using sector field ICP-MS
    • 1:CAS:528:DC%2BD38XovF2nt70%3D 10.1016/S0378-4347(01)00462-5
    • 238U in urine samples using sector field ICP-MS. J Chromatogr B 778:275-278
    • (2002) J Chromatogr , vol.778 , pp. 275-228
    • Schramel, P.1
  • 102
    • 84876921539 scopus 로고    scopus 로고
    • Detection of ultra-trace levels of uranium in urine with sector-field ICPMS: Quantification and isotope ratio determination
    • Hinrich J, Hamester M, Lindermann T, Wills JD (2003) Detection of ultra-trace levels of uranium in urine with sector-field ICPMS: quantification and isotope ratio determination. Int Labmate 28:98-99
    • (2003) Int Labmate , vol.28 , pp. 98-99
    • Hinrich, J.1    Hamester, M.2    Lindermann, T.3    Wills, J.D.4
  • 104
    • 0036392251 scopus 로고    scopus 로고
    • Determination of uranium in urine - Measurement of isotope ratios and quantification by use of ICP-MS
    • 1:CAS:528:DC%2BD38XntlGhsL0%3D 10.1007/s00216-002-1424-6
    • Krystek P, Ritsema R (2002) Determination of uranium in urine - measurement of isotope ratios and quantification by use of ICP-MS. Anal Bioanal Chem 374:226-229
    • (2002) Anal Bioanal Chem , vol.374 , pp. 226-229
    • Krystek, P.1    Ritsema, R.2
  • 106
    • 33646366406 scopus 로고    scopus 로고
    • Determination of natural and depleted uranium in urine at the PPT level: An interlaboratory analytical exercise
    • DOI 10.1097/01.HP.0000183140.38040.8a, PII 0000403220060500000008
    • Ough EA, Lewis BJ, Andrews WS, Bennett LGI, Hancock RGV, D'Agastino PA (2006) Determination of natural and depleted uranium in urine at the ppt level: an interlaboratory analytical exercise. Health Phys 90:494-499 (Pubitemid 43832693)
    • (2006) Health Physics , vol.90 , Issue.5 , pp. 494-499
    • Ough, E.A.1    Lewis, B.J.2    Andrews, W.S.3    Bennett, L.G.I.4    Hancock, R.G.V.5    D'Agastino, P.A.6
  • 108
    • 0345743464 scopus 로고    scopus 로고
    • Validated Measurements of the Uranium Isotopic Signature in Human Urine Samples Using Magnetic Sector-Field Inductively Coupled Plasma Mass Spectrometry
    • DOI 10.1021/es0346025
    • Trešl I, De Wannemacker G, Quetel CR, Petrov I, Vanhaecke F, Moens L, Taylor PDP (2004) Validated measurements of the uranium isotopic signature in human urine samples using magnetic sector-field ICP-MS. Environ Sci Technol 38:581-586 (Pubitemid 38095489)
    • (2004) Environmental Science and Technology , vol.38 , Issue.2 , pp. 581-586
    • Tresl, I.1    De Wannemacker, G.2    Quetel, C.R.3    Petrov, I.4    Vanhaecke, F.5    Moens, L.6    Taylor, P.D.P.7
  • 110
    • 36549065963 scopus 로고    scopus 로고
    • Urinary isotopic analysis in the UK Armed Forces: No evidence of depleted uranium absorption in combat and other personnel in Iraq
    • DOI 10.1136/oem.2007.032599
    • Bland D, Rona R, Coggon D, Anderson J, Greenberg N, Hull L, Wessely S (2007) Urinary isotopic analysis in the UK armed forces: no evidence of depleted uranium absorption in combat and other personnel in Iraq. Occup Environ Med 64:834-838 (Pubitemid 350207493)
    • (2007) Occupational and Environmental Medicine , vol.64 , Issue.12 , pp. 834-838
    • Bland, D.1    Rona, R.J.2    Coggon, D.3    Anderson, J.4    Greenberg, N.5    Hull, L.6    Wessely, S.7
  • 111
    • 17444417445 scopus 로고    scopus 로고
    • The quantitative analysis of uranium isotopes in the urine of the civilian population of Eastern Afghanistan after operation enduring freedom
    • Durakovic A (2005) The quantitative analysis of uranium isotopes in the urine of the civilian population of eastern Afghanistan after Operation Enduring Freedom. Mil Med 170:277-284 (Pubitemid 40547596)
    • (2005) Military Medicine , vol.170 , Issue.4 , pp. 277-284
    • Durakovic, A.1
  • 112
    • 36549082925 scopus 로고    scopus 로고
    • Depleted uranium contamination by inhalation exposure and its detection after ∼ 20 years: Implications for human health assessment
    • DOI 10.1016/j.scitotenv.2007.09.044, PII S004896970701011X
    • Parrish RR, Horstwood M, Arnason JG, Chenery S, Brewer T, Lloyd NS, Carpenter DO (2008) Depleted uranium contamination by inhalation exposure and its detection after 20 years: Implications for human health assessment. Sci Total Environ 390:58-68 (Pubitemid 350191939)
    • (2008) Science of the Total Environment , vol.390 , Issue.1 , pp. 58-68
    • Parrish, R.R.1    Horstwood, M.2    Arnason, J.G.3    Chenery, S.4    Brewer, T.5    Lloyd, N.S.6    Carpenter, D.O.7
  • 113
    • 3042587539 scopus 로고    scopus 로고
    • Rapid analysis for plutonium-239 in 1 ml of urine by magnetic sector inductively coupled plasma mass spectrometry with a desolvating introduction system
    • 1:CAS:528:DC%2BD2cXksF2ltLw%3D 10.1039/b316851d
    • Pappas RS, Ting BG, Paschal DC (2004) Rapid analysis for plutonium-239 in 1 ml of urine by magnetic sector inductively coupled plasma mass spectrometry with a desolvating introduction system. J Anal At Spectrom 19:762-766
    • (2004) J Anal at Spectrom , vol.19 , pp. 762-766
    • Pappas, R.S.1    Ting, B.G.2    Paschal, D.C.3
  • 114
    • 39749131785 scopus 로고    scopus 로고
    • Automated flow injection system using extraction chromatography for the determination of plutonium in urine by inductively coupled plasma mass spectrometry
    • DOI 10.1039/b714135a
    • Lariviere D, Cumming TA, Kiser S, Li S, Cornet RJ (2008) Automated flow injection system using extraction chromatography for the determination of plutonium in urine by inductively coupled plasma mass spectrometry. J Anal At Spectrom 23:352-360 (Pubitemid 351312180)
    • (2008) Journal of Analytical Atomic Spectrometry , vol.23 , Issue.3 , pp. 352-360
    • Lariviere, D.1    Cumming, T.A.2    Kiser, S.3    Li, C.4    Cornett, R.J.5
  • 118
    • 0041848204 scopus 로고    scopus 로고
    • Rapid analysis for plutonium-239 in urine by magnetic sector ICP-MS using Aridus desolvation introduction system
    • 1:CAS:528:DC%2BD3sXltVWnur4%3D 10.1039/b301474f
    • Ting BG, Pappas RS, Paschal DC (2003) Rapid analysis for plutonium-239 in urine by magnetic sector ICP-MS using Aridus desolvation introduction system. J Anal At Spectrom 18:795-797
    • (2003) J Anal at Spectrom , vol.18 , pp. 795-797
    • Ting, B.G.1    Pappas, R.S.2    Paschal, D.C.3
  • 119
    • 0031719166 scopus 로고    scopus 로고
    • The use of secondary ion mass spectrometry in radiotoxicology
    • Amaral A, Cossonnet C, Gale P (1998) The use of secondary ion mass spectrometry in radiotoxicology. Radiat Prot Dosim 79:137-140 (Pubitemid 28466917)
    • (1998) Radiation Protection Dosimetry , vol.79 , Issue.1-4 , pp. 137-140
    • Amaral, A.1    Cossonnett, C.2    Galle, P.3
  • 120
    • 17144366167 scopus 로고    scopus 로고
    • Evaluation of chelation concentration and cation separation of actinides at ultra-trace levels in urine matrix
    • DOI 10.1007/s10967-005-0077-2
    • Hang W, Mahan C, Zhu LW, Gonzales E (2005) Evaluation of chelation concentration and cation separation of actinides at ultra-trace levels in urine matrix. J Radioanal Nucl Chem 263:467-475 (Pubitemid 40521447)
    • (2005) Journal of Radioanalytical and Nuclear Chemistry , vol.263 , Issue.2 , pp. 467-475
    • Hang, W.1    Mahan, C.2    Zhu, L.3    Gonzales, E.4
  • 121
    • 1942485905 scopus 로고    scopus 로고
    • Determination of Pu in urine at ultratrace level by sector field inductively coupled plasma mass spectrometry
    • 1:CAS:528:DC%2BD2cXjsVCru7k%3D 10.1016/j.ijms.2004.01.006
    • Zoriy MV, Pickhardt C, Ostapczuk P, Hille R, Becker JS (2004) Determination of Pu in urine at ultratrace level by sector field inductively coupled plasma mass spectrometry. Int J Mass Spectrom 232:217-224
    • (2004) Int J Mass Spectrom , vol.232 , pp. 217-224
    • Zoriy, M.V.1    Pickhardt, C.2    Ostapczuk, P.3    Hille, R.4    Becker, J.S.5
  • 122
    • 18844423573 scopus 로고    scopus 로고
    • Rapid determination of plutonium in urine using flow injection on-line preconcentration and inductively coupled plasma mass spectrometry
    • DOI 10.1039/b501218j
    • Epov VN, Benkhedda K, Cornett RJ, Evans RD (2005) Rapid determination of plutonium in urine using flow injection on-line preconcentration and inductively coupled plasma mass spectrometry. J Anal At Spectrom 20:424-430 (Pubitemid 40683114)
    • (2005) Journal of Analytical Atomic Spectrometry , vol.20 , Issue.5 , pp. 424-430
    • Epov, V.N.1    Benkhedda, K.2    Cornett, R.J.3    Evans, R.D.4
  • 123
    • 34548222643 scopus 로고    scopus 로고
    • Determination of Pu isotope concentrations and isotope ratio by inductively coupled plasma mass spectrometry: A review of analytical methodology
    • DOI 10.1039/b617568f
    • Kim CS, Kim CK, Martin P, Sansone U (2007) Determination of Pu isotope concentrations and isotope ratio by inductively coupled plasma mass spectrometry: a review of analytical methodology. J Anal At Spectrom 22:827-841 (Pubitemid 47324832)
    • (2007) Journal of Analytical Atomic Spectrometry , vol.22 , Issue.7 , pp. 827-841
    • Kim, C.-S.1    Kim, C.-K.2    Martin, P.3    Sansone, U.4
  • 126
    • 0035979708 scopus 로고    scopus 로고
    • Determination of actinides in environmental and biological samples using high-performance chelation ion chromatography coupled to sector-field inductively coupled plasma mass spectrometry
    • DOI 10.1016/S0021-9673(01)01120-7, PII S0021967301011207
    • Truscott JB, Jones P, Fairman BE, Evans EH (2001) Determination of actinides in environmental and biological samples using high-performance chelation ion chromatography coupled to sector-field ICP-MS. J Chromatogr 928:91-98 (Pubitemid 32786876)
    • (2001) Journal of Chromatography A , vol.928 , Issue.1 , pp. 91-98
    • Truscott, J.B.1    Jones, P.2    Fairman, B.E.3    Hywel Evans, E.4
  • 127
    • 0035843608 scopus 로고    scopus 로고
    • Determination of actinide elements at femtogram per gram levels in environmental samples by on-line solid phase extraction and sector-field- inductively coupled plasma-mass spectrometry
    • DOI 10.1016/S0003-2670(01)00784-X, PII S000326700100784X
    • Truscott JB, Jones P, Fairman BE, Evans EH (2001) Determination of actinide elements at femtogram per gram levels in environmental samples by on-line solid phase extraction and sector-field ICP-MS. Anal Chim Acta 433:245-253 (Pubitemid 32434338)
    • (2001) Analytica Chimica Acta , vol.433 , Issue.2 , pp. 245-253
    • Truscott, J.B.1    Jones, P.2    Fairman, B.E.3    Evans, E.H.4
  • 128
    • 70349235360 scopus 로고    scopus 로고
    • Rapid determination of actinides in urine by ICP-MS and alpha-spectrometry: A hybrid approach
    • 1:CAS:528:DC%2BD1MXhtF2hsbzN 10.1016/j.talanta.2009.06.041
    • Maxwell SL, Vernon JD (2009) Rapid determination of actinides in urine by ICP-MS and alpha-spectrometry: a hybrid approach. Talanta 80:143-150
    • (2009) Talanta , vol.80 , pp. 143-150
    • Maxwell, S.L.1    Vernon, J.D.2
  • 129
    • 1842738378 scopus 로고    scopus 로고
    • Potentialities of mass spectrometry (ICP-MS) for actinides determination in urine
    • DOI 10.1016/j.apradiso.2004.01.007, PII S0969804304000132
    • Bouvier-Capely C, Ritt J, Baglan N, Cossonnet C (2004) Potentialities of mass spectrometry (ICP-MS) for actinides determination in urine. Appl Radiat Isot 60:629-633 (Pubitemid 38479499)
    • (2004) Applied Radiation and Isotopes , vol.60 , Issue.5 , pp. 629-633
    • Bouvier-Capely, C.1    Ritt, J.2    Baglan, N.3    Cossonnet, C.4
  • 130
    • 80052968621 scopus 로고    scopus 로고
    • Mass spectrometric analysis of long-lived radionuclides in bio-assays
    • 1:CAS:528:DC%2BC3MXht1WktLjM 10.1016/j.ijms.2011.02.012
    • Boulyga SF (2011) Mass spectrometric analysis of long-lived radionuclides in bio-assays. Int J Mass Spectrom 307:200-210
    • (2011) Int J Mass Spectr , vol.307 , pp. 200-210
    • Boulyga, S.F.1
  • 131
    • 0020070671 scopus 로고
    • Stable isotopes of lithium: In vivo differential distribution between plasma and cerebrospinal fluid
    • Stokes PE, Okamoto M, Lieberman KW, Alexander G, Triana E (1982) Stable isotopes of lithium: in vivo differential distribution between plasma and cerebrospinal fluid. Biol Psychiatry 17:413-421 (Pubitemid 12102514)
    • (1982) Biological Psychiatry , vol.17 , Issue.4 , pp. 413-421
    • Stokes, P.E.1    Okamoto, M.2    Lieberman, K.W.3
  • 132
    • 0034846258 scopus 로고    scopus 로고
    • Lithium isotopes: Differential effects on renal function and histology
    • DOI 10.1034/j.1399-5618.2001.030402.x
    • Stoll PM, Stokes PE, Okamoto M (2001) Lithium isotopes: differential effects on renal function and histology. Bipolar Disord 3:174-180 (Pubitemid 32842742)
    • (2001) Bipolar Disorders , vol.3 , Issue.4 , pp. 174-180
    • Stoll, P.M.1    Stokes, P.E.2    Okamoto, M.3
  • 133
    • 0000131407 scopus 로고
    • Thermodynamic properties and geochemistry of isotopic compounds of selenium
    • 10.1139/v62-055
    • Krouse HR, Thode HG (1962) Thermodynamic properties and geochemistry of isotopic compounds of selenium. Can J Chem 40:365-375
    • (1962) Can J Chem , vol.40 , pp. 365-375
    • Krouse, H.R.1    Thode, H.G.2
  • 134
    • 0037207821 scopus 로고    scopus 로고
    • Separation of Fe from whole blood matrix for precise isotopic ratio measurements by MC-ICP-MS: A comparison of different approaches
    • 1:CAS:528:DC%2BD38Xps1elsbo%3D 10.1039/b210482b
    • Stenberg A, Malinovsky D, Rodushkin I, Andre H, Ponter C, Öhlander B, Baxter DC (2003) Separation of Fe from whole blood matrix for precise isotopic ratio measurements by MC-ICP-MS: a comparison of different approaches. J Anal At Spectrom 18:23-28
    • (2003) J Anal at Spectrom , vol.18 , pp. 23-28
    • Stenberg, A.1    Malinovsky, D.2    Rodushkin, I.3    Andre, H.4    Ponter, C.5    Öhlander, B.6    Baxter, D.C.7
  • 135
    • 0037086010 scopus 로고    scopus 로고
    • Natural iron isotope variations in human blood
    • DOI 10.1126/science.1069389
    • Walczyk T, von Blanckenburg F (2002) Natural iron isotope variations in human blood. Science 295:2065-2066 (Pubitemid 34229466)
    • (2002) Science , vol.295 , Issue.5562 , pp. 2065-2066
    • Walczyk, T.1    Von Blanckenburg, F.2
  • 136
    • 2342557318 scopus 로고    scopus 로고
    • Isotopic analysis of Fe in human red blood cells by multiple collector-ICP-mass spectrometry
    • 1:CAS:528:DC%2BD2cXjsVGltLg%3D 10.2116/analsci.20.617
    • Ohno T, Shinohara A, Kohge I, Chiba M, Hirata T (2004) Isotopic analysis of Fe in human red blood cells by multiple collector-ICP-mass spectrometry. Anal Sci 20:617-621
    • (2004) Anal Sci , vol.20 , pp. 617-621
    • Ohno, T.1    Shinohara, A.2    Kohge, I.3    Chiba, M.4    Hirata, T.5
  • 137
    • 47049118660 scopus 로고    scopus 로고
    • Isotope ratio measurements of iron in blood samples by multi-collector ICP-MS to support nutritional investigations in humans
    • 10.1007/s12011-007-8070-y 1:CAS:528:DC%2BD1cXltleqs7k%3D
    • Benkkedda K, Chen H, Dabeka R, Cockell K (2008) Isotope ratio measurements of iron in blood samples by multi-collector ICP-MS to support nutritional investigations in humans. Biol Trace Elem Res 122:179-192
    • (2008) Biol Trace Elem Res , vol.122 , pp. 179-192
    • Benkkedda, K.1    Chen, H.2    Dabeka, R.3    Cockell, K.4
  • 138
    • 18544374590 scopus 로고    scopus 로고
    • Hereditary hemochromatosis is reflected in the iron isotope composition of blood
    • DOI 10.1182/blood-2004-07-2807
    • Krayenbühl P, Walczyk T, Schönberg R, von Blanckenburg F, Schulthess G (2005) Hereditary hemochromatosis is reflected in the iron isotope composition of blood. Blood 105:3812-3816 (Pubitemid 40656122)
    • (2005) Blood , vol.105 , Issue.10 , pp. 3812-3816
    • Krayenbuehl, P.-A.1    Walczyk, T.2    Schoenberg, R.3    Von Blanckenburg, F.4    Schulthess, G.5
  • 142
    • 17744386757 scopus 로고    scopus 로고
    • Precise zn isotopic ratio measurements of human red blood cell and hair samples by multiple collector-ICP-mass spectrometry
    • DOI 10.2116/analsci.21.425
    • Ohno T, Shinohara A, Chiba M, Hirata T (2005) Precise Zn isotope ratio measurements of human red blood cell and hair samples by multiple collector-ICP-mass spectrometry. Anal Sci 21:425-428 (Pubitemid 40579843)
    • (2005) Analytical Sciences , vol.21 , Issue.4 , pp. 425-428
    • Ohno, T.1    Shinohara, A.2    Chiba, M.3    Hirata, T.4
  • 143
    • 84863885288 scopus 로고    scopus 로고
    • Isotopic analysis of the metabolically relevant transition metals Cu, Fe and Zn in human blood from vegetarians and omnivores using multi-collector ICP-mass spectrometry
    • 10.1039/c2ja30070b 1:CAS:528:DC%2BC38XhtVSqtb3E
    • Van Heghe L, Engström E, Rodushkin I, Cloquer C, Vanhaecke F (2012) Isotopic analysis of the metabolically relevant transition metals Cu, Fe and Zn in human blood from vegetarians and omnivores using multi-collector ICP-mass spectrometry. J Anal At Spectrom 27:1327-1334
    • (2012) J Anal at Spectrom , vol.27 , pp. 1327-1334
    • Van Heghe, L.1    Engström, E.2    Rodushkin, I.3    Cloquer, C.4    Vanhaecke, F.5
  • 145
    • 77950628296 scopus 로고    scopus 로고
    • A pilot study on the use of natural calcium isotope (44Ca/40Ca) fractionation in urine as a proxy for the human body calcium balance
    • 10.1016/j.bone.2009.11.037 1:CAS:528:DC%2BC3cXjs1aktro%3D
    • 40Ca) fractionation in urine as a proxy for the human body calcium balance. Bone 46:889-896
    • (2010) Bone , vol.46 , pp. 889-896
    • Hauser, A.1    Eisenhauer, A.2
  • 146
    • 14844361461 scopus 로고    scopus 로고
    • Deciphering the iron isotope message of the human body
    • DOI 10.1016/j.ijms.2004.12.028, Isotope Ratio Measurements SI
    • Walczyk T, von Blanckenburg F (2005) Deciphering the iron isotope message of the human body. Int J Mass Spectrom 242:117-134 (Pubitemid 40353737)
    • (2005) International Journal of Mass Spectrometry , vol.242 , Issue.2-3 , pp. 117-134
    • Walczyk, T.1    Von Blanckenburg, F.2
  • 147
    • 80052386003 scopus 로고    scopus 로고
    • Isotope evidence of unaccounted for Fe and Cu erythropoietic pathways
    • 1:CAS:528:DC%2BC3MXht1CjsrrJ 10.1039/c1mt00025j
    • Albarede F, Telouk P, Lamboux A, Jaouen K, Balter V (2011) Isotope evidence of unaccounted for Fe and Cu erythropoietic pathways. Metallomic 3:926-933
    • (2011) Metallomic , vol.3 , pp. 926-933
    • Albarede, F.1    Telouk, P.2    Lamboux, A.3    Jaouen, K.4    Balter, V.5
  • 148
    • 82355165178 scopus 로고    scopus 로고
    • Hg speciation and stable isotope signatures in human hair as a tracer for dietary and occupational exposure to mercury
    • 1:CAS:528:DC%2BC3MXhtlags7fJ 10.1021/es202353m
    • Laffont L, Sonke JE, Maurice L, Monrroy SL, Chincheros J, Amouroux D, Behra P (2011) Hg speciation and stable isotope signatures in human hair as a tracer for dietary and occupational exposure to mercury. Environ Sci Technol 45:9910-9916
    • (2011) Eniron Sci Technol , vol.45 , pp. 9910-9916
    • Laffont, L.1    Sonke, J.E.2    Maurice, L.3    Monrroy, S.L.4    Chincheros, J.5    Amouroux, D.6    Behra, P.7
  • 149
    • 65049087462 scopus 로고    scopus 로고
    • Measurement of longitudinal sulphur isotopic variations by laser ablation MC-ICP-MS in single human hair strands
    • 1:CAS:528:DC%2BD1MXhs1Cktrw%3D 10.1007/s00216-009-2615-1
    • Santamaria-Fernandez R, Martinez-Sierra JG, Marchante-Gayon JM, Garcia-Alonso JI, Hearn R (2009) Measurement of longitudinal sulphur isotopic variations by laser ablation MC-ICP-MS in single human hair strands. Anal Bioanal Chem 394:225-233
    • (2009) Anal Bioanal Chem , vol.394 , pp. 225-233
    • Santamaria-Fernandez, R.1    Martinez-Sierra, J.G.2    Marchante-Gayon, J.M.3    Garcia-Alonso, J.I.4    Hearn, R.5
  • 150
    • 49449114907 scopus 로고    scopus 로고
    • Precise and traceable (13)C/(12)C isotope amount ratios by multicollector ICPMS
    • 1:CAS:528:DC%2BD1cXnsVehtro%3D 10.1021/ac800621u
    • Santamaria-Fernandez R, Carter D, Hearn R (2008) Precise and traceable (13)C/(12)C isotope amount ratios by multicollector ICPMS. Anal Chem 80:5963-5969
    • (2008) Anal Chem , vol.80 , pp. 5963-5969
    • Santamaria-Fernandez, R.1    Carter, D.2    Hearn, R.3
  • 151
    • 67349196041 scopus 로고    scopus 로고
    • Detection of counterfeit antiviral drug Heptodin and classification of counterfeits using isotope amount ratio measurements by multicollector inductively coupled plasma mass spectrometry (MC-ICPMS) and isotope ratio mass spectrometry (IRMS)
    • 1:CAS:528:DC%2BD1MXhsVertbnL 10.1016/j.scijus.2008.12.003
    • Santamaria-Fernandez R, Hearn R, Wolff JC (2009) Detection of counterfeit antiviral drug Heptodin and classification of counterfeits using isotope amount ratio measurements by multicollector inductively coupled plasma mass spectrometry (MC-ICPMS) and isotope ratio mass spectrometry (IRMS). Sci Justice 49:102-106
    • (2009) Sci Justice , vol.49 , pp. 102-106
    • Santamaria-Fernandez, R.1    Hearn, R.2    Wolff, J.C.3
  • 152
    • 0036012889 scopus 로고    scopus 로고
    • Determination of drug binding sites to proteins by electrospray ionisation mass spectrometry: The interaction of cisplatin with transferrin
    • DOI 10.1002/rcm.662
    • Allardice CS, Dyson PJ, Coffey J, Johnson N (2002) Determination of drug binding sites to proteins by electrospray ionization mass spectrometry: the interaction of cisplatin with transferrin. Rapid Comm Mass Spectrom 16:933-935 (Pubitemid 34506897)
    • (2002) Rapid Communications in Mass Spectrometry , vol.16 , Issue.10 , pp. 933-935
    • Allardyce, C.S.1    Dyson, P.J.2    Coffey, J.3    Johnson, N.4
  • 156
    • 33749432313 scopus 로고    scopus 로고
    • Stable isotopic tracing - A way forward for nanotechnology
    • DOI 10.1289/ehp.9277
    • Gulson B, Wong H (2006) Stable isotope tracing - a way forward for nanotechnology. Environ Health Perspect 114:1486-1488 (Pubitemid 44509643)
    • (2006) Environmental Health Perspectives , vol.114 , Issue.10 , pp. 1486-1488
    • Gulson, B.1    Wong, H.2
  • 157
    • 80052022643 scopus 로고    scopus 로고
    • Identification of sources of lead exposure in French children by lead isotope analysis: A cross-sectional study
    • 10.1186/1476-069X-10-1 1:CAS:528:DC%2BC3MXht1Klurg%3D
    • Oulhore Y, Le Bot B, Poupon J, Lucas JP, Mandin C, Etchevers A, Zmirou-Navier D, Glorennec P (2011) Identification of sources of lead exposure in French children by lead isotope analysis: a cross-sectional study. Environ Health 10:1-11
    • (2011) Environ Health , vol.10 , pp. 1-11
    • Oulhore, Y.1    Le Bot, B.2    Poupon, J.3    Lucas, J.P.4    Mandin, C.5    Etchevers, A.6    Zmirou-Navier, D.7    Glorennec, P.8
  • 158
    • 84859828760 scopus 로고    scopus 로고
    • A summary of strontium and oxygen isotope variations in archaeological human tooth enamel excavated from Britain
    • 1:CAS:528:DC%2BC38Xltl2msb0%3D 10.1039/c2ja10362a
    • Evans JA, Chenery CA, Montgomery J (2012) A summary of strontium and oxygen isotope variations in archaeological human tooth enamel excavated from Britain. J Anal At Spectrom 27:754-764
    • (2012) J Anal at Spectrom , vol.27 , pp. 754-764
    • Evans, J.A.1    Chenery, C.A.2    Montgomery, J.3
  • 159
    • 84859875434 scopus 로고    scopus 로고
    • Strontium and lead isotope ratios in human hair: Investigating a potential tool for determining recent human geographic movements
    • 1:CAS:528:DC%2BC38Xltl2msbw%3D 10.1039/c2ja10361c
    • Font L, van der Peijl G, van Wetten I, Vroon P, van der Wagt B, Davies G (2012) Strontium and lead isotope ratios in human hair: investigating a potential tool for determining recent human geographic movements. J Anal At Spectrom 27:719-732
    • (2012) J Anal at Spectrom , vol.27 , pp. 719-732
    • Font, L.1    Van Der Peijl, G.2    Van Wetten, I.3    Vroon, P.4    Van Der Wagt, B.5    Davies, G.6
  • 161
    • 45949124429 scopus 로고
    • Isotope ratio measurements with ICP-MS
    • 10.1016/0584-8547(87)80049-6
    • Russ P, Bazan JM (1987) Isotope ratio measurements with ICP-MS. Spectrochim Acta Part B 42:21-27
    • (1987) Spectrochim Acta Part B , vol.42 , pp. 21-27
    • Russ, P.1    Bazan, J.M.2
  • 162
    • 63049122448 scopus 로고    scopus 로고
    • Measuring 0.01 ‰ to 0.1 ‰ isotopic variations by MC-ICPMS - Testing limits for the first time with δ -iCRMs
    • 1:CAS:528:DC%2BD1MXjs1Kgsr0%3D 10.1039/b821403b
    • Quetel CR, Ponzevera E, Rodushkin I, Gerdes A, Williams R, Woodhead J (2009) Measuring 0.01 ‰ to 0.1 ‰ isotopic variations by MC-ICPMS - testing limits for the first time with δ -iCRMs. J Anal At Spectrom 24:407-412
    • (2009) J Anal at Spectrom , vol.24 , pp. 407-412
    • Quetel, C.R.1    Ponzevera, E.2    Rodushkin, I.3    Gerdes, A.4    Williams, R.5    Woodhead, J.6
  • 164
    • 80053272382 scopus 로고    scopus 로고
    • Comments on Applications of laser ablation multicollector inductively coupled plasma mass spectrometry for the measurement of calcium and lead isotope ratios in packaging for discriminatory purposes
    • 1:CAS:528:DC%2BC3MXht1Wkt7zK 10.1002/rcm.5195
    • Gordon GW (2011) Comments on Applications of laser ablation multicollector inductively coupled plasma mass spectrometry for the measurement of calcium and lead isotope ratios in packaging for discriminatory purposes. Rapid Commun Mass Spectrom 25:3196-3198
    • (2011) Rapid Commun Mass Spectrom , vol.25 , pp. 3196-3198
    • Gordon, G.W.1
  • 165
    • 6344293854 scopus 로고    scopus 로고
    • Sources of mass bias and isotope ratio variation in multi-collector ICP-MS: Optimization of instrumental parameters based on experimental observations
    • 10.1039/b403938f 1:CAS:528:DC%2BD2cXnt12isb4%3D
    • Andrén H, Rodushkin I, Stenberg A, Malinovsky D, Baxter DC (2004) Sources of mass bias and isotope ratio variation in multi-collector ICP-MS: optimization of instrumental parameters based on experimental observations. J Anal At Spectrom 19:1217-1224
    • (2004) J Anal at Spectrom , vol.19 , pp. 1217-1224
    • Andrén, H.1    Rodushkin, I.2    Stenberg, A.3    Malinovsky, D.4    Baxter, D.C.5
  • 166
    • 37749034393 scopus 로고    scopus 로고
    • The evolution and applications of multicollector ICPMS (MC-ICPMS)
    • 1:CAS:528:DC%2BD1cXis1Sntw%3D%3D 10.1007/s00216-007-1660-x
    • Douthitt CB (2008) The evolution and applications of multicollector ICPMS (MC-ICPMS). Anal Bioanal Chem 390:437-440
    • (2008) Anal Bioanal Chem , vol.390 , pp. 437-440
    • Douthitt, C.B.1
  • 167
    • 77950037968 scopus 로고    scopus 로고
    • Evaluation of zinc, cadmium and lead isotope fractionation during smelting and refining
    • 1:CAS:528:DC%2BC3cXjvFCitLg%3D 10.1016/j.scitotenv.2010.02.016
    • Shiel AE, Weis D, Orians KJ (2010) Evaluation of zinc, cadmium and lead isotope fractionation during smelting and refining. Sci Total Environ 408:2357-2368
    • (2010) Sci Total Environ , vol.408 , pp. 2357-2368
    • Shiel, A.E.1    Weis, D.2    Orians, K.J.3
  • 168
    • 77749271069 scopus 로고    scopus 로고
    • Zn and Cu isotopes as traces of anthropogenic contamination in a sediment core from an urban lake
    • 1:CAS:528:DC%2BC3cXhslShtrs%3D 10.1021/es902933y
    • Thapalia A, Borrok DM, Van Metre PC, Musgrove M, Landa ER (2010) Zn and Cu isotopes as traces of anthropogenic contamination in a sediment core from an urban lake. Environ Sci Technol 44:1544-1550
    • (2010) Environ Sci Technol , vol.44 , pp. 1544-1550
    • Thapalia, A.1    Borrok, D.M.2    Van Metre, P.C.3    Musgrove, M.4    Landa, E.R.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.