Volumn 57, Issue 9, 2002, Pages 1361-1452

Reaction cells and collision cells for ICP-MS: A tutorial review

Author keywords

Collision cell; Collision induced fragmentation; ICP MS; Ion molecule chemistry; Reaction cell

Indexed keywords

BIOLOGICAL MATERIALS; DATABASE SYSTEMS; ENERGY TRANSFER; INDUCTIVELY COUPLED PLASMA; KINETIC ENERGY; MASS SPECTROMETRY; REACTION KINETICS; THERMODYNAMICS;

EID: 0037072472     PISSN: 05848547     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0584-8547(02)00069-1     Document Type: Review
Times cited : (632)

References (161)
  • 1
    • 0001086737 scopus 로고
    • An ion-molecule scheme for the synthesis of hydrocarbon-chain and organonitrogen molecules in dense interstellar clouds
    • Schiff H.I., Bohme D.K. An ion-molecule scheme for the synthesis of hydrocarbon-chain and organonitrogen molecules in dense interstellar clouds. Astrophysical J. 232:1979;740-746.
    • (1979) Astrophysical J. , vol.232 , pp. 740-746
    • Schiff, H.I.1    Bohme, D.K.2
  • 2
    • 0142051728 scopus 로고
    • The ion chemistry of interstellar clouds
    • Smith D. The ion chemistry of interstellar clouds. Chem. Rev. 92:1992;1473-1485.
    • (1992) Chem. Rev. , vol.92 , pp. 1473-1485
    • Smith, D.1
  • 4
    • 30844453751 scopus 로고
    • Reactions of gaseous molecule ions with gaseous molecules V. theory
    • Gioumousis G., Stevenson D.P. Reactions of gaseous molecule ions with gaseous molecules V. theory. J. Chem. Phys. 29:1958;294-299.
    • (1958) J. Chem. Phys. , vol.29 , pp. 294-299
    • Gioumousis, G.1    Stevenson, D.P.2
  • 5
    • 0000889128 scopus 로고
    • Ion-polar neutral momentum transfer collision frequencies: A theoretical approach
    • Barker R.A., Ridge D.P. Ion-polar neutral momentum transfer collision frequencies: a theoretical approach. J. Chem. Phys. 64:1976;4411-4416.
    • (1976) J. Chem. Phys. , vol.64 , pp. 4411-4416
    • Barker, R.A.1    Ridge, D.P.2
  • 6
    • 0000058209 scopus 로고
    • Ion-polar molecule collisions. A modification of the average dipole orientation theory: The cos model
    • Bass L., Su T., Chesnavich W.J., Bowers M.T. Ion-polar molecule collisions. A modification of the average dipole orientation theory: the cos model. Chem. Phys. Lett. 34:1975;119-122.
    • (1975) Chem. Phys. Lett. , vol.34 , pp. 119-122
    • Bass, L.1    Su, T.2    Chesnavich, W.J.3    Bowers, M.T.4
  • 7
    • 36749115629 scopus 로고
    • Parameterization of the ion-polar molecule collision rate constant by trajectory calculations
    • Su T., Chesnavich W.J. Parameterization of the ion-polar molecule collision rate constant by trajectory calculations. J. Chem. Phys. 76:1982;5183-5185.
    • (1982) J. Chem. Phys. , vol.76 , pp. 5183-5185
    • Su, T.1    Chesnavich, W.J.2
  • 8
    • 0001158064 scopus 로고
    • Ion-polar molecule collisions. Conservation of angular momentum in the average dipole orientation theory. The AADO theory
    • Su T., Su E.C.F., Bowers M.T. Ion-polar molecule collisions. Conservation of angular momentum in the average dipole orientation theory. The AADO theory. J. Chem. Phys. 69:1978;2243-2250.
    • (1978) J. Chem. Phys. , vol.69 , pp. 2243-2250
    • Su, T.1    Su, E.C.F.2    Bowers, M.T.3
  • 10
    • 0344408615 scopus 로고
    • A survey of bimolecular ion-molecule reactions for use in modeling the chemistry of planetary atmospheres, cometary comae and interstellar clouds
    • Anicich V.G. A survey of bimolecular ion-molecule reactions for use in modeling the chemistry of planetary atmospheres, cometary comae and interstellar clouds. Astrophysical J. Suppl. Series. 84:1993;215. Available from http://astrochem.jpl.nasa.gov/asch/.
    • (1993) Astrophysical J. Suppl. Series , vol.84 , pp. 215
    • Anicich, V.G.1
  • 11
    • 0034716182 scopus 로고    scopus 로고
    • Experimental studies of positive ion chemistry with flow-tube mass spectrometry: Birth, evolution, and achievements in the 20th century
    • Bohme D.K. Experimental studies of positive ion chemistry with flow-tube mass spectrometry: birth, evolution, and achievements in the 20th century. Int. J. Mass Spectrom. 200:2000;97-136.
    • (2000) Int. J. Mass Spectrom. , vol.200 , pp. 97-136
    • Bohme, D.K.1
  • 14
    • 0034716215 scopus 로고    scopus 로고
    • Kinetic energy dependence of ion-molecule reactions: Guided ion beams and threshold measurement
    • Armentrout P.B. Kinetic energy dependence of ion-molecule reactions: guided ion beams and threshold measurement. Int. J. Mass Spectrom. 200:2000;219-241.
    • (2000) Int. J. Mass Spectrom. , vol.200 , pp. 219-241
    • Armentrout, P.B.1
  • 15
    • 33947093279 scopus 로고
    • Selected ion fragmentation with a tandem quadrupole mass spectrometer
    • Yost R.A., Enke C.G. Selected ion fragmentation with a tandem quadrupole mass spectrometer. J. Amer. Chem. Soc. 100:1978;2274-2275.
    • (1978) J. Amer. Chem. Soc. , vol.100 , pp. 2274-2275
    • Yost, R.A.1    Enke, C.G.2
  • 16
    • 0001366599 scopus 로고
    • Triple quadrupole mass spectrometry for direct mixture analysis and structure elucidation
    • Yost R.A., Enke C.G. Triple quadrupole mass spectrometry for direct mixture analysis and structure elucidation. Anal. Chem. 51:1979;1251A-1264A.
    • (1979) Anal. Chem. , vol.51
    • Yost, R.A.1    Enke, C.G.2
  • 18
    • 84989051357 scopus 로고
    • The use of triple quadrupoles for sequential mass spectrometry: 1 the instrument parameters
    • Dawson P.H., French J.B., Buckley J.A., Douglas D.J., Simmons D. The use of triple quadrupoles for sequential mass spectrometry: 1 the instrument parameters. Org. Mass Spectrom. 17:1982;205-211.
    • (1982) Org. Mass Spectrom. , vol.17 , pp. 205-211
    • Dawson, P.H.1    French, J.B.2    Buckley, J.A.3    Douglas, D.J.4    Simmons, D.5
  • 20
    • 0002273560 scopus 로고
    • Some current perspectives on ICP-MS
    • Douglas D.J. Some current perspectives on ICP-MS. Can. J. Spectroscopy. 34:1989;38-49.
    • (1989) Can. J. Spectroscopy , vol.34 , pp. 38-49
    • Douglas, D.J.1
  • 21
    • 0024715013 scopus 로고
    • Attenuation of polyatomic ion interferences in inductively coupled plasma mass spectrometry by gas-phase collisions
    • Rowan J.T., Houk R.S. Attenuation of polyatomic ion interferences in inductively coupled plasma mass spectrometry by gas-phase collisions. Appl. Spectroscopy. 43:1989;976-980.
    • (1989) Appl. Spectroscopy , vol.43 , pp. 976-980
    • Rowan, J.T.1    Houk, R.S.2
  • 22
    • 84990709626 scopus 로고
    • Ion-trap mass spectrometry with an inductively coupled plasma source
    • Barinaga C.J., Koppenaal D.W. Ion-trap mass spectrometry with an inductively coupled plasma source. Rapid Commun. Mass Spectrom. 8:1994;71-76.
    • (1994) Rapid Commun. Mass Spectrom. , vol.8 , pp. 71-76
    • Barinaga, C.J.1    Koppenaal, D.W.2
  • 23
    • 0028496250 scopus 로고
    • Performance of an inductively coupled plasma source ion trap mass spectrometer
    • Koppenaal D.W., Barinaga C.J., Smith M.R. Performance of an inductively coupled plasma source ion trap mass spectrometer. J. Anal. At. Spectrom. 9:1994;1053-1058.
    • (1994) J. Anal. At. Spectrom. , vol.9 , pp. 1053-1058
    • Koppenaal, D.W.1    Barinaga, C.J.2    Smith, M.R.3
  • 24
    • 0030126629 scopus 로고    scopus 로고
    • Selective removal of plasma matrix ions in plasma source mass spectrometry
    • Eiden G.C., Barinaga C.J., Koppenaal D.W. Selective removal of plasma matrix ions in plasma source mass spectrometry. J. Anal. At. Spectrom. 11:1996;317-322.
    • (1996) J. Anal. At. Spectrom. , vol.11 , pp. 317-322
    • Eiden, G.C.1    Barinaga, C.J.2    Koppenaal, D.W.3
  • 26
    • 0032686598 scopus 로고    scopus 로고
    • Analytical performance of the plasma source RF quadrupole ion trap in elemental and isotopic MS
    • Eiden G.C., Barinaga C.J., Koppenaal D.W. Analytical performance of the plasma source RF quadrupole ion trap in elemental and isotopic MS. J. Anal. At. Spectrom. 14:1999;1129-1132.
    • (1999) J. Anal. At. Spectrom. , vol.14 , pp. 1129-1132
    • Eiden, G.C.1    Barinaga, C.J.2    Koppenaal, D.W.3
  • 28
    • 0032623980 scopus 로고    scopus 로고
    • A dynamic reaction cell for inductively coupled plasma mass spectrometry (ICP-DRC-MS). I. The RF-field energy contribution in thermodynamics of ion-molecule reactions
    • Baranov V.I., Tanner S.D. A dynamic reaction cell for inductively coupled plasma mass spectrometry (ICP-DRC-MS). I. The RF-field energy contribution in thermodynamics of ion-molecule reactions. J. Anal. At. Spectrom. 14:1999;1133-1142.
    • (1999) J. Anal. At. Spectrom. , vol.14 , pp. 1133-1142
    • Baranov, V.I.1    Tanner, S.D.2
  • 29
    • 0033472925 scopus 로고    scopus 로고
    • A dynamic reaction cell for inductively coupled plasma mass spectrometry (ICP-DRC-MS). II. Reduction of interferences produced within the cell
    • Tanner S.D., Baranov V.I. A dynamic reaction cell for inductively coupled plasma mass spectrometry (ICP-DRC-MS). II. Reduction of interferences produced within the cell. J. Am. Soc. Mass Spectrom. 10:1999;1083-1094.
    • (1999) J. Am. Soc. Mass Spectrom. , vol.10 , pp. 1083-1094
    • Tanner, S.D.1    Baranov, V.I.2
  • 30
    • 0034270998 scopus 로고    scopus 로고
    • A dynamic reaction cell for inductively coupled plasma mass spectrometry (ICP-DRC-MS). III. Analytical performance
    • Tanner S.D., Baranov V.I., Vollkopf U. A dynamic reaction cell for inductively coupled plasma mass spectrometry (ICP-DRC-MS). III. Analytical performance. J. Anal. At. Spectrom. 15:2000;1261-1269.
    • (2000) J. Anal. At. Spectrom. , vol.15 , pp. 1261-1269
    • Tanner, S.D.1    Baranov, V.I.2    Vollkopf, U.3
  • 32
    • 0002025988 scopus 로고
    • Characteristics of multipole collision cells
    • San Francisco, Book of abstracts
    • J.E.P. Syka, Characteristics of multipole collision cells, presented at the 36th ASMS Conference on Mass Spectrometry and Allied Topics, San Francisco, 1988, Book of abstracts, 1328-1329.
    • (1988) 36th ASMS Conference on Mass Spectrometry and Allied Topics , pp. 1328-1329
    • Syka, J.E.P.1
  • 33
    • 0001239551 scopus 로고
    • New ion-optical devices utilizing oscillatory electric fields. I. Principle of operation and analytical theory of multipole devices with two-dimensional electric fields
    • Szabo I. New ion-optical devices utilizing oscillatory electric fields. I. Principle of operation and analytical theory of multipole devices with two-dimensional electric fields. Int. J. Mass Spectrom. Ion Processes. 73:1986;197-235.
    • (1986) Int. J. Mass Spectrom. Ion Processes , vol.73 , pp. 197-235
    • Szabo, I.1
  • 34
    • 0000669347 scopus 로고
    • New ion-optical devices utilizing oscillatory electric fields. II. Stability of motion in a two-dimensional hexapole field
    • Hagg C., Szabo I. New ion-optical devices utilizing oscillatory electric fields. II. Stability of motion in a two-dimensional hexapole field. Int. J. Mass Spectrom. Ion Processes. 73:1986;237-275.
    • (1986) Int. J. Mass Spectrom. Ion Processes , vol.73 , pp. 237-275
    • Hagg, C.1    Szabo, I.2
  • 35
    • 0000669342 scopus 로고
    • New ion-optical devices utilizing oscillatory electric fields. IV. Computer simulations of transport of an ion beam through an ideal quadrupole, hexapole, and octapole operating in the rf-only mode
    • Hagg C., Szabo I. New ion-optical devices utilizing oscillatory electric fields. IV. Computer simulations of transport of an ion beam through an ideal quadrupole, hexapole, and octapole operating in the rf-only mode. Int. J. Mass Spectrom. Ion Processes. 73:1986;295-312.
    • (1986) Int. J. Mass Spectrom. Ion Processes , vol.73 , pp. 295-312
    • Hagg, C.1    Szabo, I.2
  • 36
    • 0000669346 scopus 로고
    • New ion-optical devices utilizing oscillatory electric fields. III. Stability of ion motion in a two-dimentional octapole field
    • Hagg C., Szabo I. New ion-optical devices utilizing oscillatory electric fields. III. Stability of ion motion in a two-dimentional octapole field. Int. J. Mass Spectrom. Ion Processes. 73:1986;277-294.
    • (1986) Int. J. Mass Spectrom. Ion Processes , vol.73 , pp. 277-294
    • Hagg, C.1    Szabo, I.2
  • 41
    • 67049108584 scopus 로고    scopus 로고
    • Tandem quadrupole mass spectrometer for selected ion fragmentation studies and low energy collision induced dissociator therefore, US patent 4,234,791 (1980)
    • C.G. Enke, R.A. Yost, J.D. Morrison, Tandem quadrupole mass spectrometer for selected ion fragmentation studies and low energy collision induced dissociator therefore, US patent 4,234,791 (1980).
    • Enke, C.G.1    Yost, R.A.2    Morrison, J.D.3
  • 42
    • 84990642062 scopus 로고
    • Low-energy ion/molecule products from collisions with ammonia
    • Morris M., Thibault P., Boyd R.K. Low-energy ion/molecule products from collisions with ammonia. Rapid Commun. Mass Spectrom. 7:1993;1136-1140.
    • (1993) Rapid Commun. Mass Spectrom. , vol.7 , pp. 1136-1140
    • Morris, M.1    Thibault, P.2    Boyd, R.K.3
  • 44
    • 0003801639 scopus 로고
    • The application of rapid gas chromatography-tandem mass spectrometry in the analysis of complex samples for chlorinated dioxins and furans
    • L.H. Keith, C. Rappe, & G. Choudhary. Boston: Butterworth Publishers
    • Sakuma T., Gurprasad N., Tanner S.D., Ngo A., Davidson W.R., McLeod H.A., Lau B.P.-Y., Ryan J.J. The application of rapid gas chromatography-tandem mass spectrometry in the analysis of complex samples for chlorinated dioxins and furans. Keith L.H., Rappe C., Choudhary G., Chlorinated Dioxins and Dibenzofurans in the Total Environment II. 1985;139-152 Butterworth Publishers, Boston.
    • (1985) Chlorinated Dioxins and Dibenzofurans in the Total Environment II , pp. 139-152
    • Sakuma, T.1    Gurprasad, N.2    Tanner, S.D.3    Ngo, A.4    Davidson, W.R.5    McLeod, H.A.6    Lau, B.P.-Y.7    Ryan, J.J.8
  • 45
    • 0033339001 scopus 로고    scopus 로고
    • Electrospray mass spectrometry: A tool for elemental speciation
    • Stewart I.I. Electrospray mass spectrometry: a tool for elemental speciation. Spectrochim. Acta Part B. 54:1999;1649-1695.
    • (1999) Spectrochim. Acta Part B , vol.54 , pp. 1649-1695
    • Stewart, I.I.1
  • 46
    • 0033128171 scopus 로고    scopus 로고
    • LC/MS applications in drug development
    • Lee M.S., Kerns E.H. LC/MS applications in drug development. Mass Spectrom. Rev. 18:1999;187-279.
    • (1999) Mass Spectrom. Rev. , vol.18 , pp. 187-279
    • Lee, M.S.1    Kerns, E.H.2
  • 47
    • 0035241690 scopus 로고    scopus 로고
    • Mass spectrometry in proteomics
    • Aebersold R., Goodlett D.R. Mass spectrometry in proteomics. Chem. Rev. 101:2001;269-295.
    • (2001) Chem. Rev. , vol.101 , pp. 269-295
    • Aebersold, R.1    Goodlett, D.R.2
  • 48
    • 0035221502 scopus 로고    scopus 로고
    • Perspectives for mass spectrometry and functional proteomics
    • Godovac-Zimmerman J., Brown L.R. Perspectives for mass spectrometry and functional proteomics. Mass Spectrom. Rev. 20:2001;1-57.
    • (2001) Mass Spectrom. Rev. , vol.20 , pp. 1-57
    • Godovac-Zimmerman, J.1    Brown, L.R.2
  • 50
    • 44049116161 scopus 로고
    • Collisional focusing effects in radio frequency quadrupoles
    • Douglas D.J., French J.B. Collisional focusing effects in radio frequency quadrupoles. J. Am. Soc. Mass Spectrom. 3:1992;398-408.
    • (1992) J. Am. Soc. Mass Spectrom. , vol.3 , pp. 398-408
    • Douglas, D.J.1    French, J.B.2
  • 51
    • 0032231989 scopus 로고    scopus 로고
    • Applications of collision dynamics in quadrupole mass spectrometry
    • Douglas D.J. Applications of collision dynamics in quadrupole mass spectrometry. J. Am. Soc. Mass Spectrom. 9:1998;101-113.
    • (1998) J. Am. Soc. Mass Spectrom. , vol.9 , pp. 101-113
    • Douglas, D.J.1
  • 53
    • 0000065106 scopus 로고
    • Improved collisionally activated dissociation efficiency and mass resolution on a triple quadrupole mass spectrometer system
    • Thomson B.A., Douglas D.J., Corr J.J., Hager J.W., Jolliffe C.L. Improved collisionally activated dissociation efficiency and mass resolution on a triple quadrupole mass spectrometer system. Anal. Chem. 67:1995;1696-1704.
    • (1995) Anal. Chem. , vol.67 , pp. 1696-1704
    • Thomson, B.A.1    Douglas, D.J.2    Corr, J.J.3    Hager, J.W.4    Jolliffe, C.L.5
  • 54
    • 0002939021 scopus 로고    scopus 로고
    • High precision isotope ratio measurement by multicollector ICP-MS
    • Scottsdale, Arizona, Book of abstracts
    • M. Nicholls, Z. Palacz, P. Turner, High precision isotope ratio measurement by multicollector ICP-MS, presented at Winter Conference on Plasma Spectrochemistry, Scottsdale, Arizona, 1998, Book of abstracts, 413.
    • (1998) Winter Conference on Plasma Spectrochemistry , pp. 413
    • Nicholls, M.1    Palacz, Z.2    Turner, P.3
  • 57
    • 0002434888 scopus 로고    scopus 로고
    • Gas-phase metal ion chemistry investigations using quadrupole ion traps: Unimolecular dissociation, ion/molecule and ion/ion reactions
    • Book of abstracts, paper number 57
    • D. Duckworth, D.E. Goering, G.V. Van Berkel, S.A. McLuckey, Gas-phase metal ion chemistry investigations using quadrupole ion traps: Unimolecular dissociation, ion/molecule and ion/ion reactions, presented at Federation of Analytical Chemistry and Spectroscopy Societies (FACSS), 1999, Book of abstracts, paper number 57.
    • (1999) Federation of Analytical Chemistry and Spectroscopy Societies (FACSS)
    • Duckworth, D.1    Goering, D.E.2    Van Berkel, G.V.3    McLuckey, S.A.4
  • 59
    • 0003105474 scopus 로고    scopus 로고
    • Evaluation of inductively coupled plasma-ion trap mass spectrometry
    • G. Holland, & S.D. Tanner. Cambridge: The Royal Society of Chemistry
    • Furuta N., Takeda A., Zheng J. Evaluation of inductively coupled plasma-ion trap mass spectrometry. Holland G., Tanner S.D., Plasma Source Mass Spectrometry: The New Millennium. 2001;90-96 The Royal Society of Chemistry, Cambridge.
    • (2001) Plasma Source Mass Spectrometry: The New Millennium , pp. 90-96
    • Furuta, N.1    Takeda, A.2    Zheng, J.3
  • 61
    • 13944267995 scopus 로고    scopus 로고
    • A new dynamic reaction cell for reducing ICP-MS interferences using chemical resolution
    • Denoyer E.R., Tanner S.D., Vollkopf U. A new dynamic reaction cell for reducing ICP-MS interferences using chemical resolution. Spectroscopy. 14:1999;43-54.
    • (1999) Spectroscopy , vol.14 , pp. 43-54
    • Denoyer, E.R.1    Tanner, S.D.2    Vollkopf, U.3
  • 62
    • 0000814061 scopus 로고    scopus 로고
    • Application of a hexapole collision and reaction cell in ICP-MS part I: Instrumental aspects and operational optimization
    • Feldmann I., Jakubowski N., Steuwer D. Application of a hexapole collision and reaction cell in ICP-MS part I: instrumental aspects and operational optimization. Fresenius' J. Anal. Chem. 365:1999;415-421.
    • (1999) Fresenius' J. Anal. Chem. , vol.365 , pp. 415-421
    • Feldmann, I.1    Jakubowski, N.2    Steuwer, D.3
  • 63
    • 0000621636 scopus 로고    scopus 로고
    • Application of a hexapole collision and reaction cell in ICP-MS part II: Analytical figures of merit and first applications
    • Feldmann I., Jakubowski N., Thomas C., Steuwer D. Application of a hexapole collision and reaction cell in ICP-MS part II: analytical figures of merit and first applications. Fresenius' J. Anal. Chem. 365:1999;422-428.
    • (1999) Fresenius' J. Anal. Chem. , vol.365 , pp. 422-428
    • Feldmann, I.1    Jakubowski, N.2    Thomas, C.3    Steuwer, D.4
  • 64
    • 0034270804 scopus 로고    scopus 로고
    • Comparison of different nebulisers and chromatographic techniques for the speciation of selenium in nutritional commercial supplements by hexapole collision and reaction cell ICP-MS
    • Marchante-Gayon J.M., Thomas C., Feldmann I., Jakubowski N. Comparison of different nebulisers and chromatographic techniques for the speciation of selenium in nutritional commercial supplements by hexapole collision and reaction cell ICP-MS. J. Anal. At. Spectrom. 15:2000;1093-1102.
    • (2000) J. Anal. At. Spectrom. , vol.15 , pp. 1093-1102
    • Marchante-Gayon, J.M.1    Thomas, C.2    Feldmann, I.3    Jakubowski, N.4
  • 65
    • 0034923832 scopus 로고    scopus 로고
    • Reaction chemistry and collisional processes in multipole devices for resolving isobaric interferences in ICP-MS
    • Bandura D.R., Baranov V.I., Tanner S.D. Reaction chemistry and collisional processes in multipole devices for resolving isobaric interferences in ICP-MS. Fresenius' J. Anal. Chem. 370:2001;454-470.
    • (2001) Fresenius' J. Anal. Chem. , vol.370 , pp. 454-470
    • Bandura, D.R.1    Baranov, V.I.2    Tanner, S.D.3
  • 66
    • 49549128933 scopus 로고
    • The selected ion flow tube (SIFT); A technique for studying ion-neutral reactions
    • Adams N.G., Smith D. The selected ion flow tube (SIFT); a technique for studying ion-neutral reactions. Int. J. Mass Spectrom. Ion Phys. 21:1976;349-359.
    • (1976) Int. J. Mass Spectrom. Ion Phys. , vol.21 , pp. 349-359
    • Adams, N.G.1    Smith, D.2
  • 67
    • 0032649974 scopus 로고    scopus 로고
    • Determination of sulfur isotope ratios and concentrations in water samples using ICP-MS incorporating hexapole ion optics
    • Mason P.R.D., Kaspers K., vanBergen M.J. Determination of sulfur isotope ratios and concentrations in water samples using ICP-MS incorporating hexapole ion optics. J. Anal. At. Spectrom. 14:1999;1067-1074.
    • (1999) J. Anal. At. Spectrom. , vol.14 , pp. 1067-1074
    • Mason, P.R.D.1    Kaspers, K.2    VanBergen, M.J.3
  • 68
    • 0030191015 scopus 로고    scopus 로고
    • Fundamental aspects of ion extraction in inductively coupled plasma mass spectrometry
    • Niu H., Houk R.S. Fundamental aspects of ion extraction in inductively coupled plasma mass spectrometry. Spectrochim. Acta Part B. 51:1996;779-815.
    • (1996) Spectrochim. Acta Part B , vol.51 , pp. 779-815
    • Niu, H.1    Houk, R.S.2
  • 69
    • 0035979152 scopus 로고    scopus 로고
    • Dissociation of polyatomic ions in the inductively coupled plasma
    • Houk R.S., Praphairaksit N. Dissociation of polyatomic ions in the inductively coupled plasma. Spectrochim. Acta Part B. 56:2001;1069-1096.
    • (2001) Spectrochim. Acta Part B , vol.56 , pp. 1069-1096
    • Houk, R.S.1    Praphairaksit, N.2
  • 70
    • 67049119106 scopus 로고    scopus 로고
    • Personal communication
    • V.V. Lavrov, D.K. Bohme, Personal communication, 2000.
    • (2000)
    • Lavrov, V.V.1    Bohme, D.K.2
  • 72
    • 0034716188 scopus 로고    scopus 로고
    • Gas phase ion thermochemistry based on ion-equilibria: From the ionosphere to the reactive centers of enzymes
    • Kebarle P. Gas phase ion thermochemistry based on ion-equilibria: from the ionosphere to the reactive centers of enzymes. Int. J. Mass Spectrom. 200:2000;313-330.
    • (2000) Int. J. Mass Spectrom. , vol.200 , pp. 313-330
    • Kebarle, P.1
  • 73
    • 0000407032 scopus 로고
    • Ion-molecule reactions of tert-butyl alcohol by ion cyclotron resonance spectroscopy
    • Beauchamp J.L., Caserio M.C., McMahon T.B. Ion-molecule reactions of tert-butyl alcohol by ion cyclotron resonance spectroscopy. J. Amer. Chem. Soc. 96:1974;6243-6251.
    • (1974) J. Amer. Chem. Soc. , vol.96 , pp. 6243-6251
    • Beauchamp, J.L.1    Caserio, M.C.2    McMahon, T.B.3
  • 76
    • 0034271550 scopus 로고    scopus 로고
    • An inductively coupled plasma/selected-ion flow tube mass spectrometric study of the chemical resolution of isobaric interferences
    • Koyanagi G.K., Baranov V.I., Tanner S.D., Bohme D.K. An inductively coupled plasma/selected-ion flow tube mass spectrometric study of the chemical resolution of isobaric interferences. J. Anal. At. Spectrom. 15:2000;1207-1210.
    • (2000) J. Anal. At. Spectrom. , vol.15 , pp. 1207-1210
    • Koyanagi, G.K.1    Baranov, V.I.2    Tanner, S.D.3    Bohme, D.K.4
  • 79
    • 0343889803 scopus 로고    scopus 로고
    • Characteristics and capabilities of an ICP-MS with a dynamic reaction cell for dry aerosols and laser ablation
    • Hattendorf B., Günther D. Characteristics and capabilities of an ICP-MS with a dynamic reaction cell for dry aerosols and laser ablation. J. Anal. At. Spectrom. 15:2000;1125-1131.
    • (2000) J. Anal. At. Spectrom. , vol.15 , pp. 1125-1131
    • Hattendorf, B.1    Günther, D.2
  • 81
    • 0034782798 scopus 로고    scopus 로고
    • Numerical investigation of the effect of electrode size on the behaviour of quadrupole mass filters
    • Gibson J.R., Taylor S. Numerical investigation of the effect of electrode size on the behaviour of quadrupole mass filters. Rapid Commun. Mass Spectrom. 15:2001;1960-1964.
    • (2001) Rapid Commun. Mass Spectrom. , vol.15 , pp. 1960-1964
    • Gibson, J.R.1    Taylor, S.2
  • 82
    • 34250928748 scopus 로고
    • Das elektrische massenfilter als massenspektrometer und isotopentrenner
    • Paul W., Reinhard H.P., von Zahn U. Das elektrische massenfilter als massenspektrometer und isotopentrenner. Z. Physik. 152:1958;143-182.
    • (1958) Z. Physik. , vol.152 , pp. 143-182
    • Paul, W.1    Reinhard, H.P.2    Von Zahn, U.3
  • 83
    • 0001317310 scopus 로고
    • The measurement of two-dimensional fields. Part II. Study of a quadrupole magnet
    • Dayton I.E., Shoemaker F.C., Mozley R.F. The measurement of two-dimensional fields. Part II. Study of a quadrupole magnet. Rev. Sci. Instru. 25:1954;485-489.
    • (1954) Rev. Sci. Instru. , vol.25 , pp. 485-489
    • Dayton, I.E.1    Shoemaker, F.C.2    Mozley, R.F.3
  • 84
    • 0036311439 scopus 로고    scopus 로고
    • Influence of the sixth and tenth spatial harmonics on the peak shape of quadrupole mass filter with round rods'
    • Douglas D.J., Konenkov N.V. Influence of the sixth and tenth spatial harmonics on the peak shape of quadrupole mass filter with round rods'. Rapid Commun. Mass Spectrom. 16:2002;1425-1431.
    • (2002) Rapid Commun. Mass Spectrom. , vol.16 , pp. 1425-1431
    • Douglas, D.J.1    Konenkov, N.V.2
  • 85
    • 0014973284 scopus 로고
    • Operating parameters of a quadrupole in a grounded cylindrical housing
    • Denison D.R. Operating parameters of a quadrupole in a grounded cylindrical housing. J. Vac. Sci. Technol. 8:1971;266-269.
    • (1971) J. Vac. Sci. Technol. , vol.8 , pp. 266-269
    • Denison, D.R.1
  • 86
    • 0034676054 scopus 로고    scopus 로고
    • Electric hexapoles and octapoles with optimized circular section rods
    • Rao V.V.K.R., Bhutani A. Electric hexapoles and octapoles with optimized circular section rods. Int. J. Mass Spectrom. 202:2000;31-36.
    • (2000) Int. J. Mass Spectrom. , vol.202 , pp. 31-36
    • Rao, V.V.K.R.1    Bhutani, A.2
  • 87
    • 0001594639 scopus 로고
    • Comparison of quadrupole mass spectrometers with round and hyperbolic rods
    • abstract only
    • Brubaker W.M. Comparison of quadrupole mass spectrometers with round and hyperbolic rods. J. Vac. Sci. Technol. 4:1967;326. abstract only.
    • (1967) J. Vac. Sci. Technol. , vol.4 , pp. 326
    • Brubaker, W.M.1
  • 88
    • 0001855061 scopus 로고
    • Theoretical and experimental comparison of quadrupole mass analyzers with round and hyperbolic field-forming surfaces, presented at Recent Developments in Mass Spectrometry
    • Baltimore, MD: University Park Press
    • Brubaker W.M., Chamberlin W.S. Theoretical and experimental comparison of quadrupole mass analyzers with round and hyperbolic field-forming surfaces, presented at Recent Developments in Mass Spectrometry. Proceedings International Conference Mass Spectroscopy. 1970;98-103 University Park Press, Baltimore, MD.
    • (1970) Proceedings International Conference Mass Spectroscopy , pp. 98-103
    • Brubaker, W.M.1    Chamberlin, W.S.2
  • 89
    • 0001060654 scopus 로고
    • An improved quadrupole mass analyzer
    • Brubaker W.M. An improved quadrupole mass analyzer. Adv. Mass Spectrom. 4:1968;293-299.
    • (1968) Adv. Mass Spectrom. , vol.4 , pp. 293-299
    • Brubaker, W.M.1
  • 90
    • 0000498447 scopus 로고
    • Ion kinetic energies in inductively coupled plasma/mass spectrometry (ICP-MS)
    • Fulford J.E., Douglas D.J. Ion kinetic energies in inductively coupled plasma/mass spectrometry (ICP-MS). Appl. Spectroscopy. 40:1986;971-974.
    • (1986) Appl. Spectroscopy , vol.40 , pp. 971-974
    • Fulford, J.E.1    Douglas, D.J.2
  • 91
    • 0000933455 scopus 로고
    • Experimental studies of ion kinetic energies in ICP-MS
    • G. Holland, & A.N. Eaton. Cambridge: The Royal Society of Chemistry
    • Tanner S.D. Experimental studies of ion kinetic energies in ICP-MS. Holland G., Eaton A.N., Application of Plasma Source Mass Spectrometry II. 1993;222-234 The Royal Society of Chemistry, Cambridge.
    • (1993) Application of Plasma Source Mass Spectrometry II , pp. 222-234
    • Tanner, S.D.1
  • 93
    • 0001702206 scopus 로고
    • Transmission study for rf-only quadrupoles by computer simulation
    • Muntean F. Transmission study for rf-only quadrupoles by computer simulation. Int. J. Mass Spectrom. Ion Processes. 151:1995;197-206.
    • (1995) Int. J. Mass Spectrom. Ion Processes , vol.151 , pp. 197-206
    • Muntean, F.1
  • 95
    • 0000934418 scopus 로고
    • Characterization of a high-pressure quadrupole collision cell for low-energy collision-induced dissociation
    • Morris M., Thibault P., Boyd R.K. Characterization of a high-pressure quadrupole collision cell for low-energy collision-induced dissociation. J. Am. Soc. Mass Spectrom. 5:1994;1042-1063.
    • (1994) J. Am. Soc. Mass Spectrom. , vol.5 , pp. 1042-1063
    • Morris, M.1    Thibault, P.2    Boyd, R.K.3
  • 96
    • 0033059225 scopus 로고    scopus 로고
    • Characterisation of high pressure quadrupole collision cells possessing direct current axial fields
    • Lock C.M., Dyer E. Characterisation of high pressure quadrupole collision cells possessing direct current axial fields. Rapid Commun. Mass Spectrom. 13:1999;432-448.
    • (1999) Rapid Commun. Mass Spectrom. , vol.13 , pp. 432-448
    • Lock, C.M.1    Dyer, E.2
  • 97
    • 0031195139 scopus 로고    scopus 로고
    • A segmented radiofrequency - Only quadrupole collision cell for measurements of ion collision cross section on a triple quadrupole mass spectrometer
    • Javahery G., Thomson B. A segmented radiofrequency - only quadrupole collision cell for measurements of ion collision cross section on a triple quadrupole mass spectrometer. J. Am. Soc. Mass Spectrom. 8:1997;697-702.
    • (1997) J. Am. Soc. Mass Spectrom. , vol.8 , pp. 697-702
    • Javahery, G.1    Thomson, B.2
  • 98
    • 67049155436 scopus 로고    scopus 로고
    • Spectrometer with axial field, US patent 5,847,386 (1998)
    • B.A. Thomson, C.L. Jolliffe, Spectrometer with axial field, US patent 5,847,386 (1998).
    • Thomson, B.A.1    Jolliffe, C.L.2
  • 99
    • 67049132486 scopus 로고    scopus 로고
    • Novel LINAC II electrode geometry to create an axial field in a multipole ioon guide, Long Beach, California, 2000, Book of abstracts, poster number WPA016
    • A. Loboda, A. Krutchnisky, J. McNabb, V. Spicer, W. Ens, K. Standing, Novel LINAC II electrode geometry to create an axial field in a multipole ioon guide, presented at the 48th Am. Soc. Mass Spectrom. Meeting, Long Beach, California, 2000, Book of abstracts, poster number WPA016.
    • (2000) 48th Am. Soc. Mass Spectrom. Meeting
    • Loboda, A.1    Krutchnisky, A.2    McNabb, J.3    Spicer, V.4    Ens, W.5    Standing, K.6
  • 101
    • 0003263826 scopus 로고    scopus 로고
    • Inductively coupled plasma mass spectrometer with an axial field in a quadrupole reaction cell
    • in press
    • D.R. Bandura, V.I. Baranov, S.D. Tanner, Inductively coupled plasma mass spectrometer with an axial field in a quadrupole reaction cell, J. Am. Soc. Mass Spectrom. (2002), in press.
    • (2002) J. Am. Soc. Mass Spectrom.
    • Bandura, D.R.1    Baranov, V.I.2    Tanner, S.D.3
  • 103
    • 37049077622 scopus 로고
    • Gas dynamics of the inductively coupled plasma mass spectrometry interface
    • Douglas D.J., French J.B. Gas dynamics of the inductively coupled plasma mass spectrometry interface. J. Anal. At. Spectrom. 3:1988;743-747.
    • (1988) J. Anal. At. Spectrom. , vol.3 , pp. 743-747
    • Douglas, D.J.1    French, J.B.2
  • 104
    • 0028541311 scopus 로고
    • Reduction of space charge effects using a three-aperture gas dynamic vacuum interface for inductively coupled plasma-mass spectrometry
    • Tanner S.D., Cousins L.M., Douglas D.J. Reduction of space charge effects using a three-aperture gas dynamic vacuum interface for inductively coupled plasma-mass spectrometry. Appl. Spectroscopy. 48:1994;1367-1372.
    • (1994) Appl. Spectroscopy , vol.48 , pp. 1367-1372
    • Tanner, S.D.1    Cousins, L.M.2    Douglas, D.J.3
  • 105
    • 0028543065 scopus 로고
    • Gas and ion dynamics of a three-aperture vacuum interface for inductively coupled plasma-mass spectrometry
    • Tanner S.D., Douglas D.J., French J.B. Gas and ion dynamics of a three-aperture vacuum interface for inductively coupled plasma-mass spectrometry. Appl. Spectroscopy. 48:1994;1373-1378.
    • (1994) Appl. Spectroscopy , vol.48 , pp. 1373-1378
    • Tanner, S.D.1    Douglas, D.J.2    French, J.B.3
  • 106
    • 18944383811 scopus 로고    scopus 로고
    • Gas dynamics of the ICP-MS interface: Impact pressure probe measurements of gas flow profiles
    • Olney T.N., Chen W., Douglas D.J. Gas dynamics of the ICP-MS interface: impact pressure probe measurements of gas flow profiles. J. Anal. At. Spectrom. 14:1999;9-17.
    • (1999) J. Anal. At. Spectrom. , vol.14 , pp. 9-17
    • Olney, T.N.1    Chen, W.2    Douglas, D.J.3
  • 107
    • 0001196468 scopus 로고    scopus 로고
    • Multi-thermal plasma distributions from ion kinetic energy measurements
    • Providence, Rhode Island, Book of abstracts
    • V.I. Baranov, S.D. Tanner, Multi-thermal plasma distributions from ion kinetic energy measurements, presented at the 24th Federation of Analytical Chemistry and Spectroscopy Societies, Providence, Rhode Island, 1997, Book of abstracts, 133.
    • (1997) 24th Federation of Analytical Chemistry and Spectroscopy Societies , pp. 133
    • Baranov, V.I.1    Tanner, S.D.2
  • 108
    • 0031923654 scopus 로고    scopus 로고
    • Orthogonal injection of matrix-assisted laser desorption/ionization ions into a time-of-flight spectrometer through a collisional damping interface
    • Krutchinsky A.N., Loboda A.V., Spicer V.L., Dworschak R., Ens W., Standing K.G. Orthogonal injection of matrix-assisted laser desorption/ionization ions into a time-of-flight spectrometer through a collisional damping interface. Rapid Commun. Mass Spectrom. 12:1998;508-518.
    • (1998) Rapid Commun. Mass Spectrom. , vol.12 , pp. 508-518
    • Krutchinsky, A.N.1    Loboda, A.V.2    Spicer, V.L.3    Dworschak, R.4    Ens, W.5    Standing, K.G.6
  • 109
    • 0034250699 scopus 로고    scopus 로고
    • Effect of collisional damping and reactions in a dynamic reaction cell on the precision of isotope ratio measurements
    • Bandura D.R., Baranov V.I., Tanner S.D. Effect of collisional damping and reactions in a dynamic reaction cell on the precision of isotope ratio measurements. J. Anal. At. Spectrom. 15:2000;921-928.
    • (2000) J. Anal. At. Spectrom. , vol.15 , pp. 921-928
    • Bandura, D.R.1    Baranov, V.I.2    Tanner, S.D.3
  • 110
    • 0002322487 scopus 로고    scopus 로고
    • Effect of collisional damping in the dynamic reaction cell on the precision of isotope ratio measurements
    • Bandura D.R., Tanner S.D. Effect of collisional damping in the dynamic reaction cell on the precision of isotope ratio measurements. At. Spectroscopy. 20:1999;69-72.
    • (1999) At. Spectroscopy , vol.20 , pp. 69-72
    • Bandura, D.R.1    Tanner, S.D.2
  • 111
    • 0034914663 scopus 로고    scopus 로고
    • ICP-MS with hexapole collision cell for isotope ratio measurements of Ca, Fe and Se
    • Boulyga S.F., Becker J.S. ICP-MS with hexapole collision cell for isotope ratio measurements of Ca, Fe and Se. Fresenius' J. Anal. Chem. 370:2001;618-623.
    • (2001) Fresenius' J. Anal. Chem. , vol.370 , pp. 618-623
    • Boulyga, S.F.1    Becker, J.S.2
  • 112
    • 0005326553 scopus 로고    scopus 로고
    • Inductively coupled plasma mass spectrometry with hexapole collision cell: Figures of merit and applications, Entwicklung und Adwendung massenspektrometrischer Methoden zur Spuren-, Ultraspuren,-Isotopen- und Oberflachenanalytik fur Forchungsaufgaben des Forschungszentrums Julich
    • Boulyga S.F., Becker J.S. Inductively coupled plasma mass spectrometry with hexapole collision cell: figures of merit and applications, Entwicklung und Adwendung massenspektrometrischer Methoden zur Spuren-, Ultraspuren,-Isotopen- und Oberflachenanalytik fur Forchungsaufgaben des Forschungszentrums Julich. Tei. 12:2000;13-44.
    • (2000) Tei , vol.12 , pp. 13-44
    • Boulyga, S.F.1    Becker, J.S.2
  • 116
    • 67049119108 scopus 로고    scopus 로고
    • Personal communication
    • J.W. Olesik, Personal communication, 2001.
    • (2001)
    • Olesik, J.W.1
  • 117
    • 67049108580 scopus 로고    scopus 로고
    • Personal communication
    • K. Neubauer, Personal communication, 2001.
    • (2001)
    • Neubauer, K.1
  • 118
    • 0035526831 scopus 로고    scopus 로고
    • Elimination of isobaric interferences in ICP-MS, using ion-molecule reaction chemistry: Rb/Sr age determination of magmatic rocks, a case study
    • Moens L.J., Vanhaecke F.F., Bandura D.R., Baranov V.I., Tanner S.D. Elimination of isobaric interferences in ICP-MS, using ion-molecule reaction chemistry: Rb/Sr age determination of magmatic rocks, a case study. J. Anal. At. Spectrom. 16:2001;991-994.
    • (2001) J. Anal. At. Spectrom. , vol.16 , pp. 991-994
    • Moens, L.J.1    Vanhaecke, F.F.2    Bandura, D.R.3    Baranov, V.I.4    Tanner, S.D.5
  • 119
    • 0002435017 scopus 로고    scopus 로고
    • ICP-MS multielement analysis at sub-ppt levels applying new instrumental design concepts
    • G. Holland, & S.D. Tanner. Cambridge: The Royal Society of Chemistry
    • Vollkopf U., Baranov V.I., Tanner S.D. ICP-MS multielement analysis at sub-ppt levels applying new instrumental design concepts. Holland G., Tanner S.D., Plasma Source Mass Spectrometry: New Developments and Applications. 1999;63-79 The Royal Society of Chemistry, Cambridge.
    • (1999) Plasma Source Mass Spectrometry: New Developments and Applications , pp. 63-79
    • Vollkopf, U.1    Baranov, V.I.2    Tanner, S.D.3
  • 120
    • 0002045667 scopus 로고    scopus 로고
    • The determination of arsenic in seawater by platform ICP-HEX-MS
    • G. Holland, & S.D. Tanner. Cambridge: The Royal Society of Chemistry
    • Abou-Shakra F. The determination of arsenic in seawater by platform ICP-HEX-MS. Holland G., Tanner S.D., Plasma Source Mass Spectrometry: New Developments and Applications. 1999;120-131 The Royal Society of Chemistry, Cambridge.
    • (1999) Plasma Source Mass Spectrometry: New Developments and Applications , pp. 120-131
    • Abou-Shakra, F.1
  • 122
    • 0033689849 scopus 로고    scopus 로고
    • The application of inductively coupled plasma dynamic reaction cell mass spectrometry for measurement of selenium isotopes, isotope ratios and chromatographic detection of selenoamino acids
    • Sloth J.J., Larsen E.H. The application of inductively coupled plasma dynamic reaction cell mass spectrometry for measurement of selenium isotopes, isotope ratios and chromatographic detection of selenoamino acids. J. Anal. At. Spectrom. 15:2000;669-672.
    • (2000) J. Anal. At. Spectrom. , vol.15 , pp. 669-672
    • Sloth, J.J.1    Larsen, E.H.2
  • 123
    • 0001788336 scopus 로고    scopus 로고
    • Mass spectrometry and geochronology
    • deLaeter J.R. Mass spectrometry and geochronology. Mass Spectrom. Rev. 17:1998;97-125.
    • (1998) Mass Spectrom. Rev. , vol.17 , pp. 97-125
    • DeLaeter, J.R.1
  • 124
    • 0033334508 scopus 로고    scopus 로고
    • The determination of strontium isotope ratios by means of quadrupole-based ICP mass spectrometry: A geochronological case study
    • Vanhaecke F., De Wannemacker G., Moens L., Hertogen J. The determination of strontium isotope ratios by means of quadrupole-based ICP mass spectrometry: a geochronological case study. J. Anal. At. Spectrom. 14:1999;1691-1696.
    • (1999) J. Anal. At. Spectrom. , vol.14 , pp. 1691-1696
    • Vanhaecke, F.1    De Wannemacker, G.2    Moens, L.3    Hertogen, J.4
  • 125
    • 0001582738 scopus 로고    scopus 로고
    • Ion optics of multi-collector ICP-MS systems for precise and accurate isotope ratio measurement
    • Ft. Lauderdale, Book of abstracts
    • P.J. Turner, T.O. Merren, J. Speakman, R.C. Haines, Z. Palacz, Ion optics of multi-collector ICP-MS systems for precise and accurate isotope ratio measurement, presented at Winter Conference on Plasma Spectrochemistry, Ft. Lauderdale, 2000, Book of abstracts, 330-331.
    • (2000) Winter Conference on Plasma Spectrochemistry , pp. 330-331
    • Turner, P.J.1    Merren, T.O.2    Speakman, J.3    Haines, R.C.4    Palacz, Z.5
  • 126
    • 0034741477 scopus 로고    scopus 로고
    • Characteristics of a hexapole ion-guide interface for plasma-source time-of-flight mass spectrometry
    • Guzowski J.P., Hieftje G.M. Characteristics of a hexapole ion-guide interface for plasma-source time-of-flight mass spectrometry. J. Anal. At. Spectrom. 16:2001;781-792.
    • (2001) J. Anal. At. Spectrom. , vol.16 , pp. 781-792
    • Guzowski, J.P.1    Hieftje, G.M.2
  • 127
    • 0035891916 scopus 로고    scopus 로고
    • Use of an ion guide collision cell to improve the analytical performance of an inductively coupled plasma time-of-flight mass spectrometer'
    • Leach A.M., Hieftje G.M. Use of an ion guide collision cell to improve the analytical performance of an inductively coupled plasma time-of-flight mass spectrometer'. Int. J. Mass Spectrom. 212:2001;49-63.
    • (2001) Int. J. Mass Spectrom. , vol.212 , pp. 49-63
    • Leach, A.M.1    Hieftje, G.M.2
  • 128
    • 0034731456 scopus 로고    scopus 로고
    • Isotope ratio measurements of spent reactor uranium in environmental samples by using inductively coupled plasma mass spectrometry
    • Boulyga S.F., Becker J.S., Matusevitch J.L., Dietze H.-J. Isotope ratio measurements of spent reactor uranium in environmental samples by using inductively coupled plasma mass spectrometry. Int. J. Mass Spectrom. 203:2000;143-154.
    • (2000) Int. J. Mass Spectrom. , vol.203 , pp. 143-154
    • Boulyga, S.F.1    Becker, J.S.2    Matusevitch, J.L.3    Dietze, H.-J.4
  • 129
    • 25144475087 scopus 로고    scopus 로고
    • Precise and accurate isotope ratio measurements by ICP-MS
    • Becker J.S., Dietze H.-J. Precise and accurate isotope ratio measurements by ICP-MS. Fresenius' J. Anal. Chem. 368:2000;23-30.
    • (2000) Fresenius' J. Anal. Chem. , vol.368 , pp. 23-30
    • Becker, J.S.1    Dietze, H.-J.2
  • 130
    • 0028514552 scopus 로고
    • Reduction of fundamental polyatomic ions in inductively coupled plasma mass spectrometry
    • Sakata K., Kawabata K. Reduction of fundamental polyatomic ions in inductively coupled plasma mass spectrometry. Spectrochim. Acta Part B. 49:1994;1027-1038.
    • (1994) Spectrochim. Acta Part B , vol.49 , pp. 1027-1038
    • Sakata, K.1    Kawabata, K.2
  • 131
    • 3242778130 scopus 로고
    • Characterization of ionization and matrix suppression in inductively coupled 'cold' plasma mass spectrometry
    • Tanner S.D. Characterization of ionization and matrix suppression in inductively coupled 'cold' plasma mass spectrometry. J. Anal. At. Spectrom. 10:1995;905-921.
    • (1995) J. Anal. At. Spectrom. , vol.10 , pp. 905-921
    • Tanner, S.D.1
  • 132
    • 0002672239 scopus 로고    scopus 로고
    • Fundamental processes impacting performance of an ICP-MS dynamic reaction cell
    • G. Holland, & S.D. Tanner. Cambridge: The Royal Society of Chemistry
    • Tanner S.D., Baranov V.I. Fundamental processes impacting performance of an ICP-MS dynamic reaction cell. Holland G., Tanner S.D., Plasma Source Mass Spectrometry: New Development and Applications. 1999;46-62 The Royal Society of Chemistry, Cambridge.
    • (1999) Plasma Source Mass Spectrometry: New Development and Applications , pp. 46-62
    • Tanner, S.D.1    Baranov, V.I.2
  • 133
    • 0002429319 scopus 로고    scopus 로고
    • Analysis of high purity acids using a dynamic reaction cell ICP-MS
    • Bollinger D.S., Schleisman A.J. Analysis of high purity acids using a dynamic reaction cell ICP-MS. At. Spectroscopy. 20:1999;60-63.
    • (1999) At. Spectroscopy , vol.20 , pp. 60-63
    • Bollinger, D.S.1    Schleisman, A.J.2
  • 134
    • 0002934133 scopus 로고    scopus 로고
    • Initial experiences with the dynamic reaction cell ICP-MS
    • G. Holland, & S.D. Tanner. Cambridge: The Royal Society of Chemistry
    • Bollinger D.S., Schleisman A.J. Initial experiences with the dynamic reaction cell ICP-MS. Holland G., Tanner S.D., Plasma Source Mass Spectrometry: New Developments and Applications. 1999;80-92 The Royal Society of Chemistry, Cambridge.
    • (1999) Plasma Source Mass Spectrometry: New Developments and Applications , pp. 80-92
    • Bollinger, D.S.1    Schleisman, A.J.2
  • 135
    • 0002777337 scopus 로고    scopus 로고
    • Sample introduction, plasma-sample interactions, ion transport and ion-molecule reactions: Fundamental understanding and practical improvements in ICP-MS
    • G. Holland, & S.D. Tanner. Cambridge: The Royal Society of Chemistry
    • Olesik J.W., Hensman C., Rabb S., Rago D. Sample introduction, plasma-sample interactions, ion transport and ion-molecule reactions: fundamental understanding and practical improvements in ICP-MS. Holland G., Tanner S.D., Plasma Source Mass Spectrometry: The New Millennium. 2001;3-16 The Royal Society of Chemistry, Cambridge.
    • (2001) Plasma Source Mass Spectrometry: The New Millennium , pp. 3-16
    • Olesik, J.W.1    Hensman, C.2    Rabb, S.3    Rago, D.4
  • 136
    • 0002701456 scopus 로고    scopus 로고
    • The analysis of high purity hydrogen peroxide by dynamic reaction cell ICP-MS
    • Vollkopf U., Klemm K., Pfluger M. The analysis of high purity hydrogen peroxide by dynamic reaction cell ICP-MS. At. Spectroscopy. 20:1999;53-59.
    • (1999) At. Spectroscopy , vol.20 , pp. 53-59
    • Vollkopf, U.1    Klemm, K.2    Pfluger, M.3
  • 139
    • 0002117792 scopus 로고    scopus 로고
    • Multi-element analysis of potable water using the VG PQ ExCell ICP-MS incorporating Collision Cell Technology (CCT)
    • J. Godfrey, J. Cantle, P. Sigsworth, Multi-element analysis of potable water using the VG PQ ExCell ICP-MS incorporating Collision Cell Technology (CCT), presented at ninth ISMAS-WS, 2000, 114-123.
    • (2000) Ninth ISMAS-WS , pp. 114-123
    • Godfrey, J.1    Cantle, J.2    Sigsworth, P.3
  • 140
    • 67049100193 scopus 로고    scopus 로고
    • Available from http://www.chem.yorku.ca/profs/bohme/research/research.html (last accessed June 4, 2002).
  • 141
    • 0033880597 scopus 로고    scopus 로고
    • Attenuation of metal oxide ions in inductively coupled plasma mass spectrometry with hydrogen in a hexapole collision cell
    • Du Z., Houk R.S. Attenuation of metal oxide ions in inductively coupled plasma mass spectrometry with hydrogen in a hexapole collision cell. J. Anal. At. Spectrom. 15:2000;383-388.
    • (2000) J. Anal. At. Spectrom. , vol.15 , pp. 383-388
    • Du, Z.1    Houk, R.S.2
  • 142
    • 0002781936 scopus 로고    scopus 로고
    • A reaction mechanism for solving the oxide problem in ICP-MS analysis of the noble metals
    • G. Holland, & S.D. Tanner. Cambridge: The Royal Society of Chemistry
    • Simpson L.A., Thomsen M., Alloway B.J. A reaction mechanism for solving the oxide problem in ICP-MS analysis of the noble metals. Holland G., Tanner S.D., Plasma Source Mass Spectrometry: The New Millennium. 2001;148-161 The Royal Society of Chemistry, Cambridge.
    • (2001) Plasma Source Mass Spectrometry: The New Millennium , pp. 148-161
    • Simpson, L.A.1    Thomsen, M.2    Alloway, B.J.3
  • 143
    • 0016819521 scopus 로고
    • Evolution times of tropospheric positive ions
    • Huertas M.L., Fontan J. Evolution times of tropospheric positive ions. Atmos. Environ. 9:1975;1018-1026.
    • (1975) Atmos. Environ. , vol.9 , pp. 1018-1026
    • Huertas, M.L.1    Fontan, J.2
  • 145
    • 0034928275 scopus 로고    scopus 로고
    • Experimental evidence for the formation of doubly charged oxide and hydroxide ions in inductively coupled plasma mass spectrometry
    • Hattendorf B., Günther D. Experimental evidence for the formation of doubly charged oxide and hydroxide ions in inductively coupled plasma mass spectrometry. Fresenius' J. Anal. Chem. 370:2001;483-487.
    • (2001) Fresenius' J. Anal. Chem. , vol.370 , pp. 483-487
    • Hattendorf, B.1    Günther, D.2
  • 146
    • 84956224590 scopus 로고
    • Reactions of doubly charged ions at near thermal energies
    • Lindinger W. Reactions of doubly charged ions at near thermal energies. Physica Scripta. T3:1983;115-119.
    • (1983) Physica Scripta , vol.T3 , pp. 115-119
    • Lindinger, W.1
  • 147
    • 0000902950 scopus 로고    scopus 로고
    • Dynamics of charge transfer and chemical reactions of doubly-charged ions at low collision energies
    • Herman Z. Dynamics of charge transfer and chemical reactions of doubly-charged ions at low collision energies. Int. Rev. Phys. Chem. 15:1996;299-324.
    • (1996) Int. Rev. Phys. Chem. , vol.15 , pp. 299-324
    • Herman, Z.1
  • 149
    • 0001902858 scopus 로고    scopus 로고
    • Expanding the capabilities of laser ablation ICP-MS with collision and reaction cells
    • P. Sylvester. Ottawa, Canada: The Mineralogical Association of Canada
    • Mason P.R.D. Expanding the capabilities of laser ablation ICP-MS with collision and reaction cells. Sylvester P., Laser-Ablation-ICPMS in the Earth Sciences - Principles and Applications. 2001;63-81 The Mineralogical Association of Canada, Ottawa, Canada.
    • (2001) Laser-Ablation-ICPMS in the Earth Sciences - Principles and Applications , pp. 63-81
    • Mason, P.R.D.1
  • 150
    • 0035891206 scopus 로고    scopus 로고
    • Simultaneous ultra trace determination of Zr and Nb in chromium matrices with ICP Dynamic Reaction Cell MS
    • Hattendorf B., Gunter D., Schonbachler M., Halliday A. Simultaneous ultra trace determination of Zr and Nb in chromium matrices with ICP Dynamic Reaction Cell MS. Anal. Chem. 73:2001;5494-5498.
    • (2001) Anal. Chem. , vol.73 , pp. 5494-5498
    • Hattendorf, B.1    Gunter, D.2    Schonbachler, M.3    Halliday, A.4
  • 151
    • 0035526844 scopus 로고    scopus 로고
    • Multi-element analysis of melt and fluid inclusions with improved detection capabilities for Ca and Fe using laser ablation with a dynamic reaction cell ICP-MS
    • Günther D., Hattendorf B., Audetat A. Multi-element analysis of melt and fluid inclusions with improved detection capabilities for Ca and Fe using laser ablation with a dynamic reaction cell ICP-MS. J. Anal. At. Spectrom. 16:2001;1085-1090.
    • (2001) J. Anal. At. Spectrom. , vol.16 , pp. 1085-1090
    • Günther, D.1    Hattendorf, B.2    Audetat, A.3
  • 152
    • 0003326669 scopus 로고    scopus 로고
    • Instrumental concepts in ICP-MS to cope with spectral interferences
    • paper number ANAL 0384
    • N. Jakubowski, Instrumental concepts in ICP-MS to cope with spectral interferences, presented at International Congress of Pacific Basic Societies, 2000, paper number ANAL 0384.
    • (2000) International Congress of Pacific Basic Societies
    • Jakubowski, N.1
  • 159
    • 0035387929 scopus 로고    scopus 로고
    • Protein phosphorylation degree: Determination by capillary liquid chromatography and inductively coupled plasma mass spectrometry
    • Wind M., Wesch H., Lehmann W.D. Protein phosphorylation degree: determination by capillary liquid chromatography and inductively coupled plasma mass spectrometry. Anal. Chem. 73:2001;3006-3010.
    • (2001) Anal. Chem. , vol.73 , pp. 3006-3010
    • Wind, M.1    Wesch, H.2    Lehmann, W.D.3
  • 160
    • 0036534687 scopus 로고    scopus 로고
    • Detection of ultra-trace phosphorous and sulfur by quadrupole ICP-MS with Dynamic Reaction Cell'
    • Bandura D.R., Baranov V.I., Tanner S.D. Detection of ultra-trace phosphorous and sulfur by quadrupole ICP-MS with Dynamic Reaction Cell'. Anal. Chem. 74:2002;1497-1502.
    • (2002) Anal. Chem. , vol.74 , pp. 1497-1502
    • Bandura, D.R.1    Baranov, V.I.2    Tanner, S.D.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.