메뉴 건너뛰기




Volumn 51, Issue 1, 2013, Pages 229-241

Preanalytical quality improvement: In quality we trust

(15)  Lippi, Giuseppe a,b   Becan McBride, Kathleen c   Behúlová, Darina d   Bowen, Raffick A e   Church, Stephen f   Delanghe, Joris g   Grankvist, Kjell h   Kitchen, Steve i   Nybo, Mads j   Nauck, Matthias k   Nikolac, Nora l   Palicka, Vladimir m   Plebani, Mario n   Sandberg, Sverre o   Simundic, Ana Maria l,p  


Author keywords

Errors; Laboratory medicine; Preanalytical phase; Quality; Standardization

Indexed keywords

ADENOSINE DIPHOSPHATE; ARACHIDONIC ACID; COLLAGEN; DNA; DYE; LIPOPROTEIN; MICRORNA; PARAPROTEIN; PLASTIC; POVIDONE; RISTOCETIN; RNA; SILICON DIOXIDE; TRIACYLGLYCEROL;

EID: 84873856212     PISSN: 14346621     EISSN: 14374331     Source Type: Journal    
DOI: 10.1515/cclm-2012-0597     Document Type: Review
Times cited : (172)

References (67)
  • 1
    • 84875414116 scopus 로고    scopus 로고
    • Shop for quality or quantity? Volumes and costs in clinical laboratories
    • [Epub ahead of print]. DOI: 10.1515/cclm-2012-0415
    • Barletta G, Zaninotto M, Faggian D, Plebani M. Shop for quality or quantity? Volumes and costs in clinical laboratories. Clin Chem Lab Med. [Epub ahead of print]. DOI: 10.1515/cclm-2012-0415.
    • Clin Chem Lab Med.
    • Barletta, G.1    Zaninotto, M.2    Faggian, D.3    Plebani, M.4
  • 2
    • 84875441330 scopus 로고    scopus 로고
    • Testing volume is not synonymous of cost, value and efficacy in laboratory diagnostics
    • [Epub ahead of print]. doi:10.1515/cclm-2012-0502
    • Lippi G, Mattiuzzi C. Testing volume is not synonymous of cost, value and efficacy in laboratory diagnostics. Clin Chem Lab Med [Epub ahead of print]. doi:10.1515/cclm-2012-0502.
    • Clin Chem Lab Med
    • Lippi, G.1    Mattiuzzi, C.2
  • 3
    • 77953821720 scopus 로고    scopus 로고
    • Overview on patient safety in healthcare and laboratory diagnostics
    • Lippi G, Simundic AM, Mattiuzzi C. Overview on patient safety in healthcare and laboratory diagnostics. Biochem Med (Zagreb) 2010;20:131 - 43.
    • (2010) Biochem Med (Zagreb) , vol.20 , pp. 131-143
    • Lippi, G.1    Simundic, A.M.2    Mattiuzzi, C.3
  • 5
    • 77953818955 scopus 로고    scopus 로고
    • Quality in laboratory diagnostics: From theory to practice
    • Lippi G, Plebani M, Simundic AM. Quality in laboratory diagnostics: from theory to practice. Biochem Med (Zagreb) 2010;20:126 - 30.
    • (2010) Biochem Med (Zagreb) , vol.20 , pp. 126-130
    • Lippi, G.1    Plebani, M.2    Simundic, A.M.3
  • 6
    • 79960254195 scopus 로고    scopus 로고
    • Closing the brain-to-brain loop in laboratory testing
    • Plebani M, Lippi G. Closing the brain-to-brain loop in laboratory testing. Clin Chem Lab Med 2011;49:1131 - 3.
    • (2011) Clin Chem Lab Med , vol.49 , pp. 1131-1133
    • Plebani, M.1    Lippi, G.2
  • 7
    • 77749240357 scopus 로고    scopus 로고
    • The detection and prevention of errors in laboratory medicine
    • Plebani M. The detection and prevention of errors in laboratory medicine. Ann Clin Biochem 2010;47:101 - 10.
    • (2010) Ann Clin Biochem , vol.47 , pp. 101-110
    • Plebani, M.1
  • 9
    • 72649086829 scopus 로고    scopus 로고
    • To err is human. to misdiagnose might be deadly
    • Plebani M, Lippi G. To err is human. To misdiagnose might be deadly. Clin Biochem 2010;43:1 - 3.
    • (2010) Clin Biochem , vol.43 , pp. 1-3
    • Plebani, M.1    Lippi, G.2
  • 10
    • 33645757592 scopus 로고    scopus 로고
    • Preanalytical variability: The dark side of the moon in laboratory testing
    • Lippi G, Guidi GC, Mattiuzzi C, Plebani M. Preanalytical variability: the dark side of the moon in laboratory testing. Clin Chem Lab Med 2006;44:358 - 65.
    • (2006) Clin Chem Lab Med , vol.44 , pp. 358-365
    • Lippi, G.1    Guidi, G.C.2    Mattiuzzi, C.3    Plebani, M.4
  • 12
    • 84865372924 scopus 로고    scopus 로고
    • Preanalytical phase - A continuous challenge for laboratory professionals
    • Simundic AM, Lippi G. Preanalytical phase - a continuous challenge for laboratory professionals. Biochem Med (Zagreb) 2012;22:145 - 9.
    • (2012) Biochem Med (Zagreb) , vol.22 , pp. 145-149
    • Simundic, A.M.1    Lippi, G.2
  • 13
    • 77949797532 scopus 로고    scopus 로고
    • Improving the post-analytical phase
    • Plebani M, Lippi G. Improving the post-analytical phase. Clin Chem Lab Med 2010;48:435 - 6.
    • (2010) Clin Chem Lab Med , vol.48 , pp. 435-436
    • Plebani, M.1    Lippi, G.2
  • 14
    • 84855183441 scopus 로고    scopus 로고
    • Quality indicators for laboratory diagnostics: Consensus is needed
    • Plebani M, Sciacovelli L, Lippi G. Quality indicators for laboratory diagnostics: consensus is needed. Ann Clin Biochem 2011;48:479.
    • (2011) Ann Clin Biochem , vol.48 , pp. 479
    • Plebani, M.1    Sciacovelli, L.2    Lippi, G.3
  • 15
    • 79954567311 scopus 로고    scopus 로고
    • Quality indicators in laboratory medicine: From theory to practice. Preliminary data from the IFCC working group project " laboratory errors and patient safety "
    • Sciacovelli L, O 'Kane M, Skaik YA, Caciagli P, Pellegrini C, Da Rin G, et al. Quality indicators in laboratory medicine: from theory to practice. Preliminary data from the IFCC Working Group Project " Laboratory errors and patient safety ". Clin Chem Lab Med 2011;49:835 - 44.
    • (2011) Clin Chem Lab Med , vol.49 , pp. 835-844
    • Sciacovelli, L.1    'Kane M, O.2    Skaik, Y.A.3    Caciagli, P.4    Pellegrini, C.5    Da Rin, G.6
  • 16
    • 84872405460 scopus 로고    scopus 로고
    • Quality indicators to detect pre-analytical errors in laboratory testing
    • Plebani M. Quality indicators to detect pre-analytical errors in laboratory testing. Clin Biochem Rev 2012;33:85 - 8.
    • (2012) Clin Biochem Rev , vol.33 , pp. 85-88
    • Plebani, M.1
  • 19
    • 33744786784 scopus 로고    scopus 로고
    • Errors in clinical laboratories or errors in laboratory medicine ?
    • Plebani M. Errors in clinical laboratories or errors in laboratory medicine ? Clin Chem Lab Med 2006;44:750 - 9.
    • (2006) Clin Chem Lab Med , vol.44 , pp. 750-759
    • Plebani, M.1
  • 22
    • 79954563620 scopus 로고    scopus 로고
    • Prevalence of hemolytic specimens referred for arterial blood gas analysis
    • Lippi G, Ippolito L, Fontana R. Prevalence of hemolytic specimens referred for arterial blood gas analysis. Clin Chem Lab Med 2011;49:931 - 2.
    • (2011) Clin Chem Lab Med , vol.49 , pp. 931-932
    • Lippi, G.1    Ippolito, L.2    Fontana, R.3
  • 23
    • 84857654702 scopus 로고    scopus 로고
    • Hemolysis, lipaemia and icterus in specimens for arterial blood gas analysis
    • Salvagno GL, Lippi G, Gelati M, Guidi GC. Hemolysis, lipaemia and icterus in specimens for arterial blood gas analysis. Clin Biochem 2012;45:372 - 3.
    • (2012) Clin Biochem , vol.45 , pp. 372-373
    • Salvagno, G.L.1    Lippi, G.2    Gelati, M.3    Guidi, G.C.4
  • 25
    • 78651101172 scopus 로고    scopus 로고
    • Blood sample volumes in child health research: Review of safe limits
    • Howie SR. Blood sample volumes in child health research: review of safe limits. Bull World Health Organ 2011;89:46 - 53.
    • (2011) Bull World Health Organ , vol.89 , pp. 46-53
    • Howie, S.R.1
  • 26
    • 84873825514 scopus 로고    scopus 로고
    • MAP Microtube for Automated Process may be beneficial even in a laboratory setting with low frequency of microcollection specimens
    • BD Diagnostics Preanalytical Systems. Accessed 1 September, 2012
    • Conversion to BD Microtainer® ?MAP Microtube for Automated Process may be beneficial even in a laboratory setting with low frequency of microcollection specimens. BD Diagnostics Preanalytical Systems, 2010. Available from: www.bd.com/vacutainer.Accessed 1 September, 2012.
    • (2010) Conversion to BD Microtainer?
  • 27
    • 0028859116 scopus 로고
    • A new plastic evacuated tube with plasma separator
    • Landt M, Wilhite TR, Smith CC. A new plastic evacuated tube with plasma separator. J Clin Lab Anal 1995;9:101 - 6.
    • (1995) J Clin Lab Anal , vol.9 , pp. 101-106
    • Landt, M.1    Wilhite, T.R.2    Smith, C.C.3
  • 29
    • 0028205320 scopus 로고
    • Absorption of therapeutical drugs by barrier gels in serum separator blood collection tubes. Volume- and time-dependent reduction in total and free drug concentrations
    • Dasgupta A, Dean R, Saldana S, Kinnaman G, McLawhon RW. Absorption of therapeutical drugs by barrier gels in serum separator blood collection tubes. Volume- and time-dependent reduction in total and free drug concentrations, Am J Clin Pathol 1994;101:456 - 61.
    • (1994) Am J Clin Pathol , vol.101 , pp. 456-461
    • Dasgupta, A.1    Dean, R.2    Saldana, S.3    Kinnaman, G.4    McLawhon, R.W.5
  • 30
    • 12944293053 scopus 로고    scopus 로고
    • Effect of blood collection tubes on total triiodothyronine and other laboratory assays
    • Bowen RA, Chan YC, Cohen J, Rehak NN, Hortin GL, Csako G, et al. Effect of blood collection tubes on total triiodothyronine and other laboratory assays. Clin Chem 2005;2:424 - 33.
    • (2005) Clin Chem , vol.2 , pp. 424-433
    • Bowen, R.A.1    Chan, Y.C.2    Cohen, J.3    Rehak, N.N.4    Hortin, G.L.5    Csako, G.6
  • 31
    • 25444478307 scopus 로고    scopus 로고
    • Immunoassay interference by a commonly used blood collection tube additive, the organosolicone surfactant silwet L-720
    • Bowen RA, Chan Y, Ruddel ME, Hortin GL, Csako G, Demosky SJ Jr, et al. Immunoassay interference by a commonly used blood collection tube additive, the organosolicone surfactant silwet L-720. Clin Chem 2005;51:1874 - 82.
    • (2005) Clin Chem , vol.51 , pp. 1874-1882
    • Bowen, R.A.1    Chan, Y.2    Ruddel, M.E.3    Hortin, G.L.4    Csako, G.5    Demosky Jr., S.J.6
  • 32
    • 79960137736 scopus 로고    scopus 로고
    • Lipemia interferences in routine clinical biochemical tests
    • Calmarza P, Cordero J. Lipemia interferences in routine clinical biochemical tests. Biochem Med (Zagreb) 2011;21:160 - 6.
    • (2011) Biochem Med (Zagreb) , vol.21 , pp. 160-166
    • Calmarza, P.1    Cordero, J.2
  • 33
    • 73349087188 scopus 로고    scopus 로고
    • Comparison of visual versus automated detection of lipemic, icteric and hemolyzed specimens: Can we rely on a human eye ?
    • Simundic AM, Nikolac N, Ivankovic V, Ferenec-Ruzic D, Magdic B, Kvaternik M, et al. Comparison of visual versus automated detection of lipemic, icteric and hemolyzed specimens: can we rely on a human eye ? Clin Chem Lab Med 2009;47:1361 - 5.
    • (2009) Clin Chem Lab Med , vol.47 , pp. 1361-1365
    • Simundic, A.M.1    Nikolac, N.2    Ivankovic, V.3    Ferenec-Ruzic, D.4    Magdic, B.5    Kvaternik, M.6
  • 34
    • 79951711347 scopus 로고    scopus 로고
    • Lipaemic samples: Effective process for lipid reduction using high speed centrifugation compared with ultracentrifugation
    • Dimeski G, Jones BW. Lipaemic samples: effective process for lipid reduction using high speed centrifugation compared with ultracentrifugation. Biochem Med (Zagreb) 2011;21:86 - 94.
    • (2011) Biochem Med (Zagreb) , vol.21 , pp. 86-94
    • Dimeski, G.1    Jones, B.W.2
  • 35
    • 7044260841 scopus 로고    scopus 로고
    • Assay-specific differences in lipemic interference in native and intralipid-supplemented samples
    • Bornhorst JA, Roberts RF, Roberts WL. Assay-specific differences in lipemic interference in native and intralipid-supplemented samples. Clin Chem 2004;50:2197 - 201.
    • (2004) Clin Chem , vol.50 , pp. 2197-2201
    • Bornhorst, J.A.1    Roberts, R.F.2    Roberts, W.L.3
  • 36
    • 59949099529 scopus 로고    scopus 로고
    • Preanalytical errors in primary healthcare: A questionnaire study of information search procedures, test request management and test tube labelling
    • Söderberg J, Brulin C, Grankvist K, Wallin O. Preanalytical errors in primary healthcare: a questionnaire study of information search procedures, test request management and test tube labelling. Clin Chem Lab Med 2009;47:195 - 201.
    • (2009) Clin Chem Lab Med , vol.47 , pp. 195-201
    • Söderberg, J.1    Brulin, C.2    Grankvist, K.3    Wallin, O.4
  • 37
    • 77954629314 scopus 로고    scopus 로고
    • Is the test result correct ? A questionnaire study of blood collection practices in primary health care
    • Söderberg J, Wallin O, Grankvist K, Brulin C. Is the test result correct ? A questionnaire study of blood collection practices in primary health care. J Eval Clin Pract 2010;16:707 - 11.
    • (2010) J Eval Clin Pract , vol.16 , pp. 707-711
    • Söderberg, J.1    Wallin, O.2    Grankvist, K.3    Brulin, C.4
  • 38
    • 84860481145 scopus 로고    scopus 로고
    • A content validated questionnaire for assessment of self-reported venous blood sampling practices
    • Bölenius K, Brulin C, Grankvist K, Lindkvist M, Söderberg J. A content validated questionnaire for assessment of self-reported venous blood sampling practices. BMC Res Notes 2012;5:39.
    • (2012) BMC Res Notes , vol.5 , pp. 39
    • Bölenius, K.1    Brulin, C.2    Grankvist, K.3    Lindkvist, M.4    Söderberg, J.5
  • 40
    • 84875454707 scopus 로고    scopus 로고
    • Minor improvement of venous blood specimen collection practices in primary health care after a large-scale educational intervention
    • [Epub ahead of print]. DOI: 10.1515/cclm-2012-0159
    • Bölenius K, Soderberg J, Hultdin J, Lindkvist M, Brulin C, Grankvist K. Minor improvement of venous blood specimen collection practices in primary health care after a large-scale educational intervention. Clin Chem Lab Med [Epub ahead of print]. DOI: 10.1515/cclm-2012-0159.
    • Clin Chem Lab Med
    • Bölenius, K.1    Soderberg, J.2    Hultdin, J.3    Lindkvist, M.4    Brulin, C.5    Grankvist, K.6
  • 42
    • 0036275507 scopus 로고    scopus 로고
    • Preservation of urine for flow cytometric and visual microscopic testing
    • Kouri T, Vuotari L, Pohjavaara S, Laippala P. Preservation of urine for flow cytometric and visual microscopic testing. Clin Chem 2002;48:900 - 5.
    • (2002) Clin Chem , vol.48 , pp. 900-905
    • Kouri, T.1    Vuotari, L.2    Pohjavaara, S.3    Laippala, P.4
  • 43
    • 69549108768 scopus 로고    scopus 로고
    • RNA extraction from archival formalin-fixed paraffin-embedded tissue: A comparison of manual, semiautomated, and fully automated purification methods
    • Bohmann K, Hennig G, Rogel U, Poremba C, Mueller BM, Fritz P, et al. RNA extraction from archival formalin-fixed paraffin-embedded tissue: a comparison of manual, semiautomated, and fully automated purification methods. Clin Chem 2009;55:1719 - 27.
    • (2009) Clin Chem , vol.55 , pp. 1719-1727
    • Bohmann, K.1    Hennig, G.2    Rogel, U.3    Poremba, C.4    Mueller, B.M.5    Fritz, P.6
  • 44
    • 84860522345 scopus 로고    scopus 로고
    • Strategies of reducing input sample volume for extracting circulating cell-free nuclear DNA and mitochondrial DNA in plasma
    • Chen W, Cai F, Zhang B, Zhong XY. Strategies of reducing input sample volume for extracting circulating cell-free nuclear DNA and mitochondrial DNA in plasma. Clin Chem Lab Med 2011;50:261 - 5.
    • (2011) Clin Chem Lab Med , vol.50 , pp. 261-265
    • Chen, W.1    Cai, F.2    Zhang, B.3    Zhong, X.Y.4
  • 45
    • 34548176741 scopus 로고    scopus 로고
    • Testing for maternal cell contamination in prenatal samples: A comprehensive survey of current diagnostic practices in 35 molecular diagnostic laboratories
    • Schrijver I, Cherny SC, Zehnder JL. Testing for maternal cell contamination in prenatal samples: a comprehensive survey of current diagnostic practices in 35 molecular diagnostic laboratories. J Mol Diagn 2007;9:394 - 400.
    • (2007) J Mol Diagn , vol.9 , pp. 394-400
    • Schrijver, I.1    Cherny, S.C.2    Zehnder, J.L.3
  • 46
    • 84857011301 scopus 로고    scopus 로고
    • Free DNA - New potential analyte in clinical laboratory diagnostics?
    • Wagner J. Free DNA - new potential analyte in clinical laboratory diagnostics? Biochem Med (Zagreb) 2012;22:24- 38.
    • (2012) Biochem Med (Zagreb) , vol.22 , pp. 24-38
    • Wagner, J.1
  • 49
    • 84866085262 scopus 로고    scopus 로고
    • Quality standards for sample processing, transportation, and storage in hemostasis testing
    • Adcock Funk DM, Lippi G, Favaloro EJ. Quality standards for sample processing, transportation, and storage in hemostasis testing. Semin Thromb Hemost 2012;38:576 - 85.
    • (2012) Semin Thromb Hemost , vol.38 , pp. 576-585
    • Adcock Funk, D.M.1    Lippi, G.2    Favaloro, E.J.3
  • 53
    • 0031920554 scopus 로고    scopus 로고
    • Minimum specimen volume requirements for routine coagulation testing; Dependence on citrate concentration
    • Adcock DM, Kressin DC, Marlar RA. Minimum specimen volume requirements for routine coagulation testing; dependence on citrate concentration. Am J Clin Pathol 1998;109:595 - 9.
    • (1998) Am J Clin Pathol , vol.109 , pp. 595-599
    • Adcock, D.M.1    Kressin, D.C.2    Marlar, R.A.3
  • 54
    • 84897287128 scopus 로고    scopus 로고
    • The bias of routine hemostasis testing due to underfilling of primary blood tubes is not mathematically predictable. Annual Meeting of the American Association of Clinical Chemistry (AACC), Los Angeles (CA-USA), 15-19 July 2012
    • Lippi G, Salvagno G, Montagnana M, Guidi G, Favaloro EJ. The bias of routine hemostasis testing due to underfilling of primary blood tubes is not mathematically predictable. Annual Meeting of the American Association of Clinical Chemistry (AACC), Los Angeles (CA-USA), 15 - 19 July 2012. Clin Chem 2012;(Suppl):A17.
    • (2012) Clin Chem , Issue.SUPPL.
    • Lippi, G.1    Salvagno, G.2    Montagnana, M.3    Guidi, G.4    Favaloro, E.J.5
  • 55
    • 80052574167 scopus 로고    scopus 로고
    • Guidelines for the laboratory investigation of heritable disorders of platelet function
    • Harrison P, Mackie I, Mumford A, Briggs C, Liesner R, Winter M, et al. Guidelines for the laboratory investigation of heritable disorders of platelet function. Br J Haematol 2011:155;30 - 44.
    • (2011) Br J Haematol , vol.155 , pp. 30-44
    • Harrison, P.1    MacKie, I.2    Mumford, A.3    Briggs, C.4    Liesner, R.5    Winter, M.6
  • 56
    • 84867821406 scopus 로고    scopus 로고
    • European medical laboratory accreditation. Present situation and steps to harmonisation
    • Huisman W. European medical laboratory accreditation. Present situation and steps to harmonisation. Clin Chem Lab Med 2012;50:1147 - 52.
    • (2012) Clin Chem Lab Med , vol.50 , pp. 1147-1152
    • Huisman, W.1
  • 57
    • 77953868631 scopus 로고    scopus 로고
    • The prevalence of preanalytical errors in a Croatian ISO 15189 accredited laboratory
    • Simundic AM, Nikolac N, Vukasovic I, Vrkic N. The prevalence of preanalytical errors in a Croatian ISO 15189 accredited laboratory. Clin Chem Lab Med 2010;48:1009 - 14.
    • (2010) Clin Chem Lab Med , vol.48 , pp. 1009-1014
    • Simundic, A.M.1    Nikolac, N.2    Vukasovic, I.3    Vrkic, N.4
  • 58
    • 84865387523 scopus 로고    scopus 로고
    • The most common nonconformities encountered during the assessments of medical laboratories in Hong Kong using ISO 15189 as accreditation criteria
    • Ho B, Ho E. The most common nonconformities encountered during the assessments of medical laboratories in Hong Kong using ISO 15189 as accreditation criteria. Biochem Med (Zagreb) 2012;22:247 - 57.
    • (2012) Biochem Med (Zagreb) , vol.22 , pp. 247-257
    • Ho, B.1    Ho, E.2
  • 60
    • 44949158707 scopus 로고    scopus 로고
    • Haemolysis: An overview of the leading cause of unsuitable specimens in clinical laboratories
    • Lippi G, Blanckaert N, Bonini P, Green S, Kitchen S, Palicka V, et al. Haemolysis: an overview of the leading cause of unsuitable specimens in clinical laboratories. Clin Chem Lab Med 2008;46:764 - 72.
    • (2008) Clin Chem Lab Med , vol.46 , pp. 764-772
    • Lippi, G.1    Blanckaert, N.2    Bonini, P.3    Green, S.4    Kitchen, S.5    Palicka, V.6
  • 61
    • 50249142508 scopus 로고    scopus 로고
    • Quality indicators and specifications for strategic and support processes in laboratory medicine
    • Ricós C, Biosca C, Ibarz M, Minchinela J, Llopis M, Perich C, et al. Quality indicators and specifications for strategic and support processes in laboratory medicine. Clin Chem Lab Med 2008;46:1189 - 94.
    • (2008) Clin Chem Lab Med , vol.46 , pp. 1189-1194
    • Ricós, C.1    Biosca, C.2    Ibarz, M.3    Minchinela, J.4    Llopis, M.5    Perich, C.6
  • 62
    • 84857817756 scopus 로고    scopus 로고
    • Exploring the initial steps of the testing process: Frequency and nature of pre-preanalytic errors
    • Carraro P, Zago T, Plebani M. Exploring the initial steps of the testing process: frequency and nature of pre-preanalytic errors. Clin Chem 2012;58:638 - 42.
    • (2012) Clin Chem , vol.58 , pp. 638-642
    • Carraro, P.1    Zago, T.2    Plebani, M.3
  • 64
    • 70349492209 scopus 로고    scopus 로고
    • Hemolysis index: Quality indicator or criterion for sample rejection ?
    • Plebani M, Lippi G. Hemolysis index: quality indicator or criterion for sample rejection ? Clin Chem Lab Med 2009;47:899 - 902.
    • (2009) Clin Chem Lab Med , vol.47 , pp. 899-902
    • Plebani, M.1    Lippi, G.2
  • 65
    • 0026067038 scopus 로고    scopus 로고
    • Erroneous laboratory values obtained from central catheters
    • Johnston JB, Messina M. Erroneous laboratory values obtained from central catheters. J Intraven Nurs 19991;14:13 - 5.
    • (1999) J Intraven Nurs , vol.14 , pp. 13-15
    • Johnston, J.B.1    Messina, M.2
  • 66
    • 33847411472 scopus 로고    scopus 로고
    • High total protein impairs appropriate gel barrier formation in BD Vacutainer blood collection tubes
    • Van den Ouweland, Church S. High total protein impairs appropriate gel barrier formation in BD Vacutainer blood collection tubes. Clin Chem 2007;53:364 - 5.
    • (2007) Clin Chem , vol.53 , pp. 364-365
    • Van Den Ouweland, C.S.1
  • 67
    • 70349505403 scopus 로고    scopus 로고
    • Event reporting in laboratory medicine. Is there something we are missing ?
    • Lippi G, Mattiuzzi C, Plebani M. Event reporting in laboratory medicine. Is there something we are missing ? MLO Med Lab Obs 2009;41:23.
    • (2009) MLO Med Lab Obs , vol.41 , pp. 23
    • Lippi, G.1    Mattiuzzi, C.2    Plebani, M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.