메뉴 건너뛰기




Volumn 47, Issue 8, 2009, Pages 934-939

Multicenter evaluation of the hemolysis index in automated clinical chemistry systems

Author keywords

Errors; Hemolysis; Hemolysis index (HI); Patient safety; Preanalytical variability

Indexed keywords

HEMOGLOBIN;

EID: 70349484951     PISSN: 14346621     EISSN: 14374331     Source Type: Journal    
DOI: 10.1515/CCLM.2009.218     Document Type: Article
Times cited : (118)

References (18)
  • 1
    • 84941841395 scopus 로고
    • Haemolysis as an interference factor in clinical chemistry
    • Sonntag O. Haemolysis as an interference factor in clinical chemistry. J Clin Chem Clin Biochem 1986;24;127-139
    • (1986) J Clin Chem Clin Biochem , vol.24 , pp. 127-139
    • Sonntag, O.1
  • 2
    • 84941843918 scopus 로고
    • Haemolysis as an influence and interference factor in clinical chemistry
    • Guder W. Haemolysis as an influence and interference factor in clinical chemistry. J Clin Chem Clin Biochem 1986;24:125-126
    • (1986) J Clin Chem Clin Biochem , vol.24 , pp. 125-126
    • Guder, W.1
  • 3
    • 0030893027 scopus 로고    scopus 로고
    • Chemistry specimen acceptability. A College of American pathologists QProbes study of 453 laboratories
    • Jones BA, Calam RR, Howanitz PJ. Chemistry specimen acceptability. A College of American Pathologists QProbes study of 453 laboratories. Arch Pathol Lab Med 1997;121:19-26.
    • (1997) Arch Pathol Lab Med , vol.121 , pp. 19-26
    • Jones, B.A.1    Calam, R.R.2    Howanitz, P.J.3
  • 4
    • 0033972513 scopus 로고    scopus 로고
    • Haemolyzed specimens: A reason for rejection or clinical challenge?
    • Carraro P. Servidio P, Plebani M. Haemolyzed specimens: a reason for rejection or clinical challenge? Clin Chem 2000;46:306-307
    • (2000) Clin Chem , vol.46 , pp. 306-307
    • Carraro, P.1    Servidio, P.2    Plebani, M.3
  • 6
    • 34250741964 scopus 로고    scopus 로고
    • Risk management in the preanalytical phase of laboratory testing
    • Lippi G, Guidi GC. Risk management in the preanalytical phase of laboratory testing. Clin Chem Lab Med 2007
    • (2007) Clin Chem Lab Med
    • Lippi, G.1    Guidi, G.C.2
  • 7
    • 44949158707 scopus 로고    scopus 로고
    • Haemolysis: An overview of the leading cause of unsuitable specimens in clinical laboratories
    • Lippi G, Blanckaert N, Bonini P, Green S, Kitchen S, Palicka V, et al. Haemolysis: an overview of the leading cause of unsuitable specimens in clinical laboratories. Clin Chem Lab Med 2008;46:764-772
    • (2008) Clin Chem Lab Med , vol.46 , pp. 764-772
    • Lippi, G.1    Blanckaert, N.2    Bonini, P.3    Green, S.4    Kitchen, S.5    Palicka, V.6
  • 11
    • 49449109301 scopus 로고    scopus 로고
    • Near-patient testing of potassium levels using arterial blood gas analysers: Can we trust these results?
    • José RJ, Preller J. Near-patient testing of potassium levels using arterial blood gas analysers: can we trust these results? Emerg Med J 2008;25:510-513
    • (2008) Emerg Med J , vol.25 , pp. 510-513
    • José, R.J.1    Preller, J.2
  • 12
    • 84942402086 scopus 로고
    • Immunonephelometric quantification of free haemoglobin
    • Lammers M. Gressner AM. Immunonephelometric quantification of free haemoglobin. J Clin Chem Clin Biochem 1987;25:363-367
    • (1987) J Clin Chem Clin Biochem , vol.25 , pp. 363-367
    • Lammers, M.1    Gressner, A.M.2
  • 13
    • 27644507273 scopus 로고
    • Practical uses of serum indexes to reduce errors from lipemia, icterus, and hemolysis
    • Glick MR, Ryder KW, Vroon DH, Masters BE, Sonntag O. Practical uses of serum indexes to reduce errors from lipemia, icterus, and hemolysis. Clin Chem 1990;36:1008.
    • (1990) Clin Chem , vol.36 , pp. 1008
    • Glick, M.R.1    Ryder, K.W.2    Vroon, D.H.3    Masters, B.E.4    Sonntag, O.5
  • 15
    • 33846528579 scopus 로고    scopus 로고
    • Correction of patient results for beckman coulter LX-20 assays affected by interference due to hemoglobin, bilirubin or lipids: A practical approach
    • Vermeer HJ, Steen G, Naus AJ, Goevaerts B, Agricola PT, Schoenmakers CH. Correction of patient results for Beckman Coulter LX-20 assays affected by interference due to hemoglobin, bilirubin or lipids: a practical approach. Clin Chem Lab Med 2007;45:114-119
    • (2007) Clin Chem Lab Med , vol.45 , pp. 114-119
    • Vermeer, H.J.1    Steen, G.2    Naus, A.J.3    Goevaerts, B.4    Agricola, P.T.5    Schoenmakers, C.H.6
  • 18
    • 0032739052 scopus 로고    scopus 로고
    • Quality specifications and allowable standards for validation of methods used in clinical biochemistry
    • Vassault A, Grafmeyer D, de Graeve J, Cohen R, Beaudonnet A, Bienvenu J. Quality specifications and allowable standards for validation of methods used in clinical biochemistry. Ann Biol Clin 1999;57:685-695
    • (1999) Ann Biol Clin , vol.57 , pp. 685-695
    • Vassault, A.1    Grafmeyer, D.2    De Graeve, J.3    Cohen, R.4    Beaudonnet, A.5    Bienvenu, J.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.