메뉴 건너뛰기




Volumn 16, Issue 4, 2010, Pages 707-711

Is the test result correct? A questionnaire study of blood collection practices in primary health care

Author keywords

blood specimen collection; medical errors; phlebotomy; primary health care; questionnaires; specimen handling

Indexed keywords

ARTICLE; BLOOD SAMPLING; CLINICAL LABORATORY; CONTROLLED STUDY; INTERMETHOD COMPARISON; MEDICAL PRACTICE; PATIENT IDENTIFICATION; PRIMARY MEDICAL CARE; PRIORITY JOURNAL; QUESTIONNAIRE; VENOUS BLOOD; VENOUS STASIS;

EID: 77954629314     PISSN: 13561294     EISSN: 13652753     Source Type: Journal    
DOI: 10.1111/j.1365-2753.2009.01179.x     Document Type: Article
Times cited : (26)

References (24)
  • 1
    • 10044255447 scopus 로고    scopus 로고
    • Medical errors: Impact on clinical laboratories and other critical areas
    • Kalra, J. (2004) Medical errors: impact on clinical laboratories and other critical areas. Clinical Biochemistry, 37 (12 1052 1062.
    • (2004) Clinical Biochemistry , vol.37 , Issue.12 , pp. 1052-1062
    • Kalra, J.1
  • 2
    • 0030797124 scopus 로고    scopus 로고
    • Mistakes in a stat laboratory: Types and frequency
    • Plebani, M. Carraro, P. (1997) Mistakes in a stat laboratory: types and frequency. Clinical Chemistry, 43 (8 Pt 1 1348 1351.
    • (1997) Clinical Chemistry , vol.43 , Issue.8 PART 1 , pp. 1348-1351
    • Plebani, M.1    Carraro, P.2
  • 4
    • 0036840561 scopus 로고    scopus 로고
    • Wrong biochemistry results: Two case reports and observational study in 5310 patients on potentially misleading thyroid-stimulating hormone and gonadotropin immunoassay results
    • Ismail, A. A., Walker, P. L., Barth, J. H., Lewandowski, K. C., Jones, R. Burr, W. A. (2002) Wrong biochemistry results: two case reports and observational study in 5310 patients on potentially misleading thyroid-stimulating hormone and gonadotropin immunoassay results. Clinical Chemistry, 48 (11 2023 2029.
    • (2002) Clinical Chemistry , vol.48 , Issue.11 , pp. 2023-2029
    • Ismail, A.A.1    Walker, P.L.2    Barth, J.H.3    Lewandowski, K.C.4    Jones, R.5    Burr, W.A.6
  • 5
    • 3042740322 scopus 로고    scopus 로고
    • Types and frequency of preanalytical mistakes in the first Thai ISO 9002:1994 certified clinical laboratory, a 6-month monitoring
    • Wiwanitkit, V. (2001) Types and frequency of preanalytical mistakes in the first Thai ISO 9002:1994 certified clinical laboratory, a 6-month monitoring. BMC Clinical Pathology, 1 (1 5.
    • (2001) BMC Clinical Pathology , vol.1 , Issue.1 , pp. 5
    • Wiwanitkit, V.1
  • 6
    • 34347402441 scopus 로고    scopus 로고
    • Errors in a stat laboratory: Types and frequencies 10 years later
    • Carraro, P. Plebani, M. (2007) Errors in a stat laboratory: types and frequencies 10 years later. Clinical Chemistry, 53 (7 1338 1342.
    • (2007) Clinical Chemistry , vol.53 , Issue.7 , pp. 1338-1342
    • Carraro, P.1    Plebani, M.2
  • 7
    • 0036213297 scopus 로고    scopus 로고
    • Outpatient phlebotomy success and reasons for specimen rejection
    • Dale, J. C. Novis, D. A. (2002) Outpatient phlebotomy success and reasons for specimen rejection. Archives of Pathology and Laboratory Medicine, 126 (4 416 419.
    • (2002) Archives of Pathology and Laboratory Medicine , vol.126 , Issue.4 , pp. 416-419
    • Dale, J.C.1    Novis, D.A.2
  • 8
    • 0032833988 scopus 로고    scopus 로고
    • Within-person variation of plasma homocysteine and effects of posture and tourniquet application
    • Rasmussen, K., Moller, J. Lyngbak, M. (1999) Within-person variation of plasma homocysteine and effects of posture and tourniquet application. Clinical Chemistry, 45 (10 1850 1855.
    • (1999) Clinical Chemistry , vol.45 , Issue.10 , pp. 1850-1855
    • Rasmussen, K.1    Moller, J.2    Lyngbak, M.3
  • 12
    • 0029878630 scopus 로고    scopus 로고
    • Why is the laboratory an afterthought for managed care organizations?
    • Forsman, R. W. (1996) Why is the laboratory an afterthought for managed care organizations? Clinical Chemistry, 42 (5 813 816.
    • (1996) Clinical Chemistry , vol.42 , Issue.5 , pp. 813-816
    • Forsman, R.W.1
  • 16
    • 33744786784 scopus 로고    scopus 로고
    • Errors in clinical laboratories or errors in laboratory medicine?
    • Plebani, M. (2006) Errors in clinical laboratories or errors in laboratory medicine? Clinical Chemistry and Laboratory Medicine, 44 (6 750 759.
    • (2006) Clinical Chemistry and Laboratory Medicine , vol.44 , Issue.6 , pp. 750-759
    • Plebani, M.1
  • 17
    • 0041973611 scopus 로고    scopus 로고
    • Conveying the importance of the preanalytical phase
    • Young, D. S. (2003) Conveying the importance of the preanalytical phase. Clinical Chemistry and Laboratory Medicine, 41 (7 884 887.
    • (2003) Clinical Chemistry and Laboratory Medicine , vol.41 , Issue.7 , pp. 884-887
    • Young, D.S.1
  • 18
    • 33746764438 scopus 로고    scopus 로고
    • Identification errors involving clinical laboratories: A College of American Pathologists Q-Probes study of patient and specimen identification errors at 120 institutions
    • Valenstein, P. N., Raab, S. S. Walsh, M. K. (2006) Identification errors involving clinical laboratories: a College of American Pathologists Q-Probes study of patient and specimen identification errors at 120 institutions. Archives of Pathology and Laboratory Medicine, 130 (8 1106 1113.
    • (2006) Archives of Pathology and Laboratory Medicine , vol.130 , Issue.8 , pp. 1106-1113
    • Valenstein, P.N.1    Raab, S.S.2    Walsh, M.K.3
  • 19
    • 4344648887 scopus 로고    scopus 로고
    • Clinical interpretation of reference intervals and reference limits. A plea for assay harmonization
    • Klee, G. G. (2004) Clinical interpretation of reference intervals and reference limits. A plea for assay harmonization. Clinical Chemistry and Laboratory Medicine, 42 (7 752 757.
    • (2004) Clinical Chemistry and Laboratory Medicine , vol.42 , Issue.7 , pp. 752-757
    • Klee, G.G.1
  • 20
    • 21344450532 scopus 로고    scopus 로고
    • Standardization of total cholesterol measurement in population surveys - Pre-analytic sources of variation and their effect on the prevalence of hypercholesterolaemia
    • Tolonen, H., Ferrario, M. Kuulasmaa, K. (2005) Standardization of total cholesterol measurement in population surveys - pre-analytic sources of variation and their effect on the prevalence of hypercholesterolaemia. European Journal of Cardiovascular Prevention and Rehabilitation, 12 (3 257 267.
    • (2005) European Journal of Cardiovascular Prevention and Rehabilitation , vol.12 , Issue.3 , pp. 257-267
    • Tolonen, H.1    Ferrario, M.2    Kuulasmaa, K.3
  • 21
    • 0034938879 scopus 로고    scopus 로고
    • Preanalytical recommendations of the 'Groupe d'Etude sur l'Hemostase et la Thrombose' (GEHT) for venous blood testing in hemostasis laboratories
    • Polack, B., Schved, J. F. Boneu, B. (2001) Preanalytical recommendations of the 'Groupe d'Etude sur l'Hemostase et la Thrombose' (GEHT) for venous blood testing in hemostasis laboratories. Haemostasis, 31 (1 61 68.
    • (2001) Haemostasis , vol.31 , Issue.1 , pp. 61-68
    • Polack, B.1    Schved, J.F.2    Boneu, B.3
  • 23
    • 40449118414 scopus 로고    scopus 로고
    • Prevalence and type of pre-analytical problems for inpatients samples in coagulation laboratory
    • Salvagno, G. L., Lippi, G., Bassi, A., Poli, G. Guidi, G. C. (2008) Prevalence and type of pre-analytical problems for inpatients samples in coagulation laboratory. Journal of Evaluation in Clinical Practice, 14 (2 351 353.
    • (2008) Journal of Evaluation in Clinical Practice , vol.14 , Issue.2 , pp. 351-353
    • Salvagno, G.L.1    Lippi, G.2    Bassi, A.3    Poli, G.4    Guidi, G.C.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.