메뉴 건너뛰기




Volumn 43, Issue 1-2, 2010, Pages 1-3

To err is human. To misdiagnose might be deadly

Author keywords

[No Author keywords available]

Indexed keywords

ANALYTICAL ERROR; AUTOMATION; CLINICAL DECISION MAKING; DIAGNOSTIC ACCURACY; DIAGNOSTIC ERROR; DIAGNOSTIC VALUE; EDITORIAL; EQUIPMENT; HARM REDUCTION; HEALTH CARE QUALITY; HEALTH CARE SYSTEM; INFORMATION TECHNOLOGY; LABORATORY DIAGNOSIS; MEDICAL ERROR; MORTALITY; PATIENT SAFETY; PRACTICE GUIDELINE; PRIORITY JOURNAL; QUALITY CONTROL; RISK REDUCTION; TOTAL QUALITY MANAGEMENT; UNITED STATES;

EID: 72649086829     PISSN: 00099120     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.clinbiochem.2009.07.002     Document Type: Editorial
Times cited : (39)

References (27)
  • 3
    • 72649104910 scopus 로고    scopus 로고
    • Consumers Union, is Deadly. Available at:, Last Accessed 22 June 2009
    • Consumers Union. To Err is Human - To Delay is Deadly. Available at: http://www.safepatientproject.org/2009/05/to_err_is_humanto_delay_is_dea.html. Last Accessed 22 June 2009.
    • To Err is Human - To Delay
  • 4
    • 62149142125 scopus 로고    scopus 로고
    • Diagnostic errors-the next frontier for patient safety
    • Newman-Toker D.E., and Pronovost P.J. Diagnostic errors-the next frontier for patient safety. JAMA 301 (2009) 1060-1062
    • (2009) JAMA , vol.301 , pp. 1060-1062
    • Newman-Toker, D.E.1    Pronovost, P.J.2
  • 5
    • 33645757592 scopus 로고    scopus 로고
    • Preanalytical variability: the dark side of the moon in laboratory testing
    • Lippi G., Guidi G.C., Mattiuzzi C., and Plebani M. Preanalytical variability: the dark side of the moon in laboratory testing. Clin Chem Lab Med 44 (2006) 358-365
    • (2006) Clin Chem Lab Med , vol.44 , pp. 358-365
    • Lippi, G.1    Guidi, G.C.2    Mattiuzzi, C.3    Plebani, M.4
  • 6
    • 20144381547 scopus 로고    scopus 로고
    • Diagnostic errors in medicine: a case of neglect
    • Graber M. Diagnostic errors in medicine: a case of neglect. Jt Comm J Qual Patient Saf 31 (2005) 106-113
    • (2005) Jt Comm J Qual Patient Saf , vol.31 , pp. 106-113
    • Graber, M.1
  • 7
    • 34250727503 scopus 로고    scopus 로고
    • Medical laboratories: Reducing error through risk management and continual improvement: complementary element
    • ISO/TS 22367
    • ISO/TS 22367: 2008. Medical laboratories: reducing error through risk management and continual improvement: complementary element.
    • (2008)
  • 8
    • 84928096034 scopus 로고    scopus 로고
    • RADPEER quality assurance program: a multifacility study of interpretive disagreement rates
    • Borgstede J.P., Lewis R.S., Bhargavan M., and Sunshine J.H. RADPEER quality assurance program: a multifacility study of interpretive disagreement rates. J Am Coll Radiol 1 (2004) 59-65
    • (2004) J Am Coll Radiol , vol.1 , pp. 59-65
    • Borgstede, J.P.1    Lewis, R.S.2    Bhargavan, M.3    Sunshine, J.H.4
  • 9
    • 34247590797 scopus 로고    scopus 로고
    • Accuracy of diagnostic procedures: has it improved over the past 5 decades?
    • Berlin L. Accuracy of diagnostic procedures: has it improved over the past 5 decades?. AJR 188 (2007) 1173-1178
    • (2007) AJR , vol.188 , pp. 1173-1178
    • Berlin, L.1
  • 10
    • 33744786784 scopus 로고    scopus 로고
    • Errors in clinical laboratories or errors in laboratory medicine?
    • Plebani M. Errors in clinical laboratories or errors in laboratory medicine?. Clin Chem Lab Med 44 (2006) 750-759
    • (2006) Clin Chem Lab Med , vol.44 , pp. 750-759
    • Plebani, M.1
  • 11
    • 43249110698 scopus 로고    scopus 로고
    • Quality improvement in laboratory medicine: extra-analytical issues
    • Lippi G., Fostini R., and Guidi G.C. Quality improvement in laboratory medicine: extra-analytical issues. Clin Lab Med 28 (2008) 285-294
    • (2008) Clin Lab Med , vol.28 , pp. 285-294
    • Lippi, G.1    Fostini, R.2    Guidi, G.C.3
  • 12
    • 67349237752 scopus 로고    scopus 로고
    • Exploring the iceberg of errors in laboratory medicine
    • Plebani M. Exploring the iceberg of errors in laboratory medicine. Clin Chim Acta 404 (2009) 16-23
    • (2009) Clin Chim Acta , vol.404 , pp. 16-23
    • Plebani, M.1
  • 13
    • 0030797124 scopus 로고    scopus 로고
    • Mistakes in a stat laboratory: types and frequency
    • Plebani M., and Carraro P. Mistakes in a stat laboratory: types and frequency. Clin Chem 43 (1997) 1348-1351
    • (1997) Clin Chem , vol.43 , pp. 1348-1351
    • Plebani, M.1    Carraro, P.2
  • 14
    • 34347402441 scopus 로고    scopus 로고
    • Errors in a stat laboratory: types and frequencies 10 years later
    • Carraro P., and Plebani M. Errors in a stat laboratory: types and frequencies 10 years later. Clin Chem 53 (2007) 1338-1342
    • (2007) Clin Chem , vol.53 , pp. 1338-1342
    • Carraro, P.1    Plebani, M.2
  • 15
    • 0001191221 scopus 로고
    • On the scientific evaluation of diagnostic procedures
    • Garland L.H. On the scientific evaluation of diagnostic procedures. Radiology 52 (1949) 309-328
    • (1949) Radiology , vol.52 , pp. 309-328
    • Garland, L.H.1
  • 16
    • 34447534324 scopus 로고    scopus 로고
    • Excusable neglect in malpractice suits against radiologists: a proposed jury instruction to recognize the human condition
    • Caldwell C., and Seamone E.R. Excusable neglect in malpractice suits against radiologists: a proposed jury instruction to recognize the human condition. Ann Health Law 16 (2007) 43-77
    • (2007) Ann Health Law , vol.16 , pp. 43-77
    • Caldwell, C.1    Seamone, E.R.2
  • 17
    • 67349217809 scopus 로고    scopus 로고
    • The beginning of the second decade of the era of patient safety: implications and roles for the clinical laboratory and laboratory professionals
    • Hilborne L.H., Lubin I.M., and Scheuner M.T. The beginning of the second decade of the era of patient safety: implications and roles for the clinical laboratory and laboratory professionals. Clin Chim Acta 404 (2009) 24-27
    • (2009) Clin Chim Acta , vol.404 , pp. 24-27
    • Hilborne, L.H.1    Lubin, I.M.2    Scheuner, M.T.3
  • 18
    • 26044440188 scopus 로고    scopus 로고
    • Errors in laboratory medicine: practical lessons to improve patient safety
    • Howanitz P.J. Errors in laboratory medicine: practical lessons to improve patient safety. Arch Pathol Lab Med 129 (2005) 1252-1261
    • (2005) Arch Pathol Lab Med , vol.129 , pp. 1252-1261
    • Howanitz, P.J.1
  • 19
    • 33646694120 scopus 로고    scopus 로고
    • Improving patient safety through quality assurance
    • Raab S.S. Improving patient safety through quality assurance. Arch Pathol Lab Med 130 (2006) 633-637
    • (2006) Arch Pathol Lab Med , vol.130 , pp. 633-637
    • Raab, S.S.1
  • 20
    • 0036770449 scopus 로고    scopus 로고
    • Q-tracks: a College of American Pathologists program of continuous laboratory monitoring and longitudinal tracking
    • Zarbo R.J., Jones B.A., Friedberg R.C., et al. Q-tracks: a College of American Pathologists program of continuous laboratory monitoring and longitudinal tracking. Arch Pathol Lab Med 126 (2002) 1036-1044
    • (2002) Arch Pathol Lab Med , vol.126 , pp. 1036-1044
    • Zarbo, R.J.1    Jones, B.A.2    Friedberg, R.C.3
  • 21
    • 0036311365 scopus 로고    scopus 로고
    • Continuous wristband monitoring over 2 years decreases identification errors: a College of American Pathologists Q-Tracks Study
    • Howanitz P.J., Renner S.W., and Walsh M.K. Continuous wristband monitoring over 2 years decreases identification errors: a College of American Pathologists Q-Tracks Study. Arch Pathol Lab Med 126 (2002) 809-815
    • (2002) Arch Pathol Lab Med , vol.126 , pp. 809-815
    • Howanitz, P.J.1    Renner, S.W.2    Walsh, M.K.3
  • 22
    • 33744822185 scopus 로고    scopus 로고
    • ISO 15189:2003-quality management, evaluation and continual improvement
    • Burnett D. ISO 15189:2003-quality management, evaluation and continual improvement. Clin Chem Lab Med 44 (2006) 733-739
    • (2006) Clin Chem Lab Med , vol.44 , pp. 733-739
    • Burnett, D.1
  • 23
    • 67349257919 scopus 로고    scopus 로고
    • The IFCC Working Group on laboratory errors and patient safety
    • Sciacovelli L., and Plebani M. The IFCC Working Group on laboratory errors and patient safety. Clin Chim Acta 404 (2009) 79-85
    • (2009) Clin Chim Acta , vol.404 , pp. 79-85
    • Sciacovelli, L.1    Plebani, M.2
  • 24
    • 72649102023 scopus 로고    scopus 로고
    • National Quality Forum. Preferred Practices for Measuring and Reporting Patient Safety and Communication in Laboratory Medicine: A Consensus Report. Available at: www.qualityforum.org/publications/reports/lab.asp. Last Access: 22 June 2009.
    • National Quality Forum. Preferred Practices for Measuring and Reporting Patient Safety and Communication in Laboratory Medicine: A Consensus Report. Available at: www.qualityforum.org/publications/reports/lab.asp. Last Access: 22 June 2009.
  • 25
    • 70349505403 scopus 로고    scopus 로고
    • Event reporting in laboratory medicine. Is there something we are missing
    • Lippi G., Mattiuzzi C., and Plebani M. Event reporting in laboratory medicine. Is there something we are missing. MLO Med Lab Obs 41 (2009) 23
    • (2009) MLO Med Lab Obs , vol.41 , pp. 23
    • Lippi, G.1    Mattiuzzi, C.2    Plebani, M.3
  • 26
    • 67049158825 scopus 로고    scopus 로고
    • Disclosing errors that affect multiple patients
    • Chafe R., Levinson W., and Sullivan T. Disclosing errors that affect multiple patients. CMAJ 26 (2009) 1125-1127
    • (2009) CMAJ , vol.26 , pp. 1125-1127
    • Chafe, R.1    Levinson, W.2    Sullivan, T.3
  • 27
    • 18644383685 scopus 로고    scopus 로고
    • Five years after To Err Is Human: what have we learned?
    • Leape L.L., and Berwick D.M. Five years after To Err Is Human: what have we learned?. JAMA 293 (2005) 2384-2390
    • (2005) JAMA , vol.293 , pp. 2384-2390
    • Leape, L.L.1    Berwick, D.M.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.