-
1
-
-
0038377458
-
GEANT4: A simulation toolkit
-
10.1016/S0168-9002(03)01368-8 0168-9002 A
-
Agostinelli S et al 2003 GEANT4: a simulation toolkit Nucl. Instrum. Methods Phys. Res. A 506 250-303
-
(2003)
Nucl. Instrum. Methods Phys. Res.
, vol.506
, Issue.3
, pp. 250-303
-
-
Agostinelli, S.1
-
2
-
-
84855615112
-
Real-time prompt gamma monitoring in spot-scanning proton therapy using imaging through a knife-edge shaped slit
-
10.1088/0031-9155/57/2/297 0031-9155
-
Bom V, Joulaeizadeh L and Beekman F 2012 Real-time prompt gamma monitoring in spot-scanning proton therapy using imaging through a knife-edge shaped slit Phys. Med. Biol. 57 297-308
-
(2012)
Phys. Med. Biol.
, vol.57
, Issue.2
, pp. 297-308
-
-
Bom, V.1
Joulaeizadeh, L.2
Beekman, F.3
-
3
-
-
33745488460
-
IMRT: A review and preview
-
0031-9155 R21
-
Bortfeld T 2006 IMRT: a review and preview Phys. Med. Biol. 51 R363-79
-
(2006)
Phys. Med. Biol.
, vol.51
, Issue.13
-
-
Bortfeld, T.1
-
4
-
-
0033095316
-
Cross-section evaluations to 150 MeV for accelerator-driven systems and implementation in MCNPX
-
Chadwick M B et al 1999 Cross-section evaluations to 150 MeV for accelerator-driven systems and implementation in MCNPX Nucl. Sci. Eng. 131 293-328 (Pubitemid 129309578)
-
(1999)
Nuclear Science and Engineering
, vol.131
, Issue.3
, pp. 293-328
-
-
Chadwick, M.B.1
Young, P.G.2
Chiba, S.3
Frankle, S.C.4
Hale, G.M.5
Hughes, H.G.6
Koning, A.J.7
Little, R.C.8
MacFarlane, R.E.9
Prael, R.E.10
Waters, L.S.11
-
5
-
-
57049129935
-
Intensity modulated radiotherapy: Advantages, limitations and future developments
-
10.2349/biij.2.1.e19 1823-5530
-
Cheung K Y 2006 Intensity modulated radiotherapy: advantages, limitations and future developments Biomed. Imaging Interv. J. 2 19
-
(2006)
Biomed. Imaging Interv. J.
, vol.2
, Issue.1
, pp. 19
-
-
Cheung, K.Y.1
-
6
-
-
77951148906
-
Hadrontherapy: An Open Source, Geant4-based application for proton-ion therapy studies
-
Cirrone G A P et al 2009 Hadrontherapy: an Open Source, Geant4-based application for proton-ion therapy studies IEEE Nucl. Sci. Symp. Conf. Record pp 4186-9
-
(2009)
IEEE Nucl. Sci. Symp. Conf. Record
, pp. 4186-4189
-
-
Cirrone, G.A.P.1
-
7
-
-
79960844502
-
Improving time resolution in time-of-flight PET
-
10.1016/j.nima.2010.11.171 0168-9002 A
-
Conti M 2011 Improving time resolution in time-of-flight PET Nucl. Instrum. Methods Phys. Res. A 648 S194-8
-
(2011)
Nucl. Instrum. Methods Phys. Res.
, vol.648
-
-
Conti, M.1
-
8
-
-
71849100672
-
3-based PET scanner
-
10.1088/0031-9155/55/1/004 0031-9155
-
3-based PET scanner Phys. Med. Biol. 55 45-64
-
(2010)
Phys. Med. Biol.
, vol.55
, Issue.1
, pp. 45-64
-
-
Daube-Witherspoon, M.E.1
Surti, S.2
Perkins, A.3
Kyba, C.C.M.4
Wiener, R.5
Werner, M.E.6
Kulp, R.7
Karp, J.S.8
-
9
-
-
79960310626
-
Arrays of digital silicon photomultipliers - Intrinsic performance and application to scintillator readout
-
Degenhardt C, Zwaans B, Frach T and De Gruyter R 2010 Arrays of digital silicon photomultipliers - intrinsic performance and application to scintillator readout IEEE Nucl. Sci. Symp. Conf. Record pp 1954-6
-
(2010)
IEEE Nucl. Sci. Symp. Conf. Record
, pp. 1954-1956
-
-
Degenhardt, C.1
Zwaans, B.2
Frach, T.3
De Gruyter, R.4
-
10
-
-
79960837393
-
Silicon Photomultipliers (SiPM) as novel photodetectors for PET
-
10.1016/j.nima.2010.11.128 0168-9002 A
-
Del Guerra A, Belcari N, Bisogni M G, Corsi F, Foresta M, Guerra P, Marcatili S, Santos A and Sportelli G 2011 Silicon Photomultipliers (SiPM) as novel photodetectors for PET Nucl. Instrum. Methods Phys. Res. A 648 S232-5
-
(2011)
Nucl. Instrum. Methods Phys. Res.
, vol.648
-
-
Del Guerra, A.1
Belcari, N.2
Bisogni, M.G.3
Corsi, F.4
Foresta, M.5
Guerra, P.6
Marcatili, S.7
Santos, A.8
Sportelli, G.9
-
11
-
-
0032666628
-
Broad-beam three-dimensional irradiation system for heavy-ion radiotherapy at HIMAC
-
10.1016/S0168-9002(99)00194-1 0168-9002 A
-
Futami Y, Kanai T, Fujita M, Tomura H, Higashi A, Matsufuji N, Miyahara N, Endo M and Kawachi K 1999 Broad-beam three-dimensional irradiation system for heavy-ion radiotherapy at HIMAC Nucl. Instrum. Methods Phys. Res. A 430 143-53
-
(1999)
Nucl. Instrum. Methods Phys. Res.
, vol.430
, Issue.1
, pp. 143-153
-
-
Futami, Y.1
Kanai, T.2
Fujita, M.3
Tomura, H.4
Higashi, A.5
Matsufuji, N.6
Miyahara, N.7
Endo, M.8
Kawachi, K.9
-
12
-
-
84859908339
-
The DLED algorithm for timing measurements on large area SiPMs coupled to scintillators
-
10.1109/TNS.2012.2187927 0018-9499
-
Gola A, Piemonte C and Tarolli A 2012 The DLED algorithm for timing measurements on large area SiPMs coupled to scintillators IEEE Trans. Nucl. Sci. 59 358-65
-
(2012)
IEEE Trans. Nucl. Sci.
, vol.59
, Issue.2
, pp. 358-365
-
-
Gola, A.1
Piemonte, C.2
Tarolli, A.3
-
13
-
-
77956393759
-
Optimization of GEANT4 settings for proton pencil beam scanning simulations using GATE
-
10.1016/j.nimb.2010.07.011 0168-583X B
-
Grevillot L, Frisson T, Zahra N, Bertrand D, Stichelbaut F, Freud N and Sarrut D 2010 Optimization of GEANT4 settings for proton pencil beam scanning simulations using GATE Nucl. Instrum. Methods Phys. Res. B 268 3295-305
-
(2010)
Nucl. Instrum. Methods Phys. Res.
, vol.268
, Issue.20
, pp. 3295-3305
-
-
Grevillot, L.1
Frisson, T.2
Zahra, N.3
Bertrand, D.4
Stichelbaut, F.5
Freud, N.6
Sarrut, D.7
-
15
-
-
21444434583
-
The Heidelberg ion therapy center
-
10.1016/S0167-8140(04)80046-X 0167-8140
-
Haberer T, Debus J, Eickhoff H, Jäkel O, Schultz-Ertner D and Weber U 2004 The Heidelberg ion therapy center Radiother. Oncol. 73 S186-90
-
(2004)
Radiother. Oncol.
, vol.73
-
-
Haberer, T.1
Debus, J.2
Eickhoff, H.3
Jäkel, O.4
Schultz-Ertner, D.5
Weber, U.6
-
16
-
-
17844399274
-
Monte Carlo simulation of a protontherapy platform devoted to ocular melanoma
-
DOI 10.1118/1.1871392
-
Herault J, Iborra N, Serrano B and Chauvel P 2005 Monte Carlo simulation of a protontherapy platform devoted to ocular melanoma Med. Phys. 32 910-9 (Pubitemid 40586775)
-
(2005)
Medical Physics
, vol.32
, Issue.4
, pp. 910-919
-
-
Herault, J.1
Iborra, N.2
Serrano, B.3
Chauvel, P.4
-
17
-
-
33748798224
-
Heavy ion synchrotron for medical use-HIMAC project at NIRS-Japan
-
10.1016/0375-9474(92)90803-R 0375-9474 A
-
Hiraoa Y et al 1992 Heavy ion synchrotron for medical use-HIMAC project at NIRS-Japan Nucl. Phys. A 538 541-50
-
(1992)
Nucl. Phys.
, vol.538
, pp. 541-550
-
-
Hiraoa, Y.1
-
18
-
-
0004179507
-
-
Stopping Powers for Electrons and Positrons ICRU Report 37 International Commission On Radiation Units and Measurements (ICRU), Bethesda, MD, USA)
-
ICRU 1984 Stopping Powers for Electrons and Positrons ICRU Report 37 International Commission On Radiation Units and Measurements (ICRU), Bethesda, MD, USA)
-
(1984)
ICRU Report
-
-
-
19
-
-
70350176156
-
Multi-pixel photon counters for TOF PET detector and its challenges
-
10.1109/TNS.2009.2028075 0018-9499
-
Kim C L, Wang G-C and Dolinsky S 2009 Multi-pixel photon counters for TOF PET detector and its challenges IEEE Trans. Nucl. Sci. 56 2580-5
-
(2009)
IEEE Trans. Nucl. Sci.
, vol.56
, Issue.5
, pp. 2580-2585
-
-
Kim, C.L.1
Wang, G.-C.2
Dolinsky, S.3
-
20
-
-
79251601055
-
A Compton imager for in vivo dosimetry of proton beams: A design study
-
10.1016/j.nima.2010.10.031 0168-9002 A
-
Kormoll T, Fiedler F, Schöne S, Wüstemann J, Zuber K and Enghardt W 2011 A Compton imager for in vivo dosimetry of proton beams: a design study Nucl. Instrum. Methods Phys. Res. A 626-627 114-9
-
(2011)
Nucl. Instrum. Methods Phys. Res.
, vol.626-627
, pp. 114-119
-
-
Kormoll, T.1
Fiedler, F.2
Schöne, S.3
Wüstemann, J.4
Zuber, K.5
Enghardt, W.6
-
21
-
-
84867271563
-
Progress in using prompt gammas for ion range monitoring during hardron-therapy
-
10.1016/S0167-8140(12)70127-5 0167-8140
-
Krimmer J et al 2012 Progress in using prompt gammas for ion range monitoring during hardron-therapy Radiother. Oncol. 102 S71-2
-
(2012)
Radiother. Oncol.
, vol.102
-
-
Krimmer, J.1
-
23
-
-
79960842475
-
First tests in the application of silicon photomultiplier arrays to dose monitoring in hadron therapy
-
10.1016/j.nima.2010.12.092 0168-9002 A
-
Llosá G, Barrio J, Lacasta C, Callier S, Raux L and Taille C L 2010 First tests in the application of silicon photomultiplier arrays to dose monitoring in hadron therapy Nucl. Instrum. Methods Phys. Res. A 648 S96-9
-
(2010)
Nucl. Instrum. Methods Phys. Res.
, vol.648
-
-
Llosá, G.1
Barrio, J.2
Lacasta, C.3
Callier, S.4
Raux, L.5
Taille, C.L.6
-
24
-
-
39049164210
-
Intensity modulated proton therapy and its sensitivity to treatment uncertainties 1: The potential effects of calculational uncertainties
-
DOI 10.1088/0031-9155/53/4/014, PII S0031915508549608
-
Lomax A J 2008a Intensity modulated proton therapy and its sensitivity to treatment uncertainties 1: the potential effects of calculational uncertainties Phys. Med. Biol. 53 1027-42 (Pubitemid 351238121)
-
(2008)
Physics in Medicine and Biology
, vol.53
, Issue.4
, pp. 1027-1042
-
-
Lomax, A.J.1
-
25
-
-
39049126842
-
Intensity modulated proton therapy and its sensitivity to treatment uncertainties 2: The potential effects of inter-fraction and inter-field motions
-
DOI 10.1088/0031-9155/53/4/015, PII S0031915508549589
-
Lomax A J 2008b Intensity modulated proton therapy and its sensitivity to treatment uncertainties 2: the potential effects of inter-fraction and inter-field motions Phys. Med. Biol. 53 1043-56 (Pubitemid 351238122)
-
(2008)
Physics in Medicine and Biology
, vol.53
, Issue.4
, pp. 1043-1056
-
-
Lomax, A.J.1
-
26
-
-
84867255876
-
-
Mashnik S G 2006 Implementation of CEM03.01 into MCNP6 and its Verification and Validation Running Through MCNP6 CEM03.02 Upgrade Research Note X-3-RN(U)-07-03 Los Alamos National Laboratory
-
(2006)
Research Note
-
-
Mashnik, S.G.1
-
27
-
-
84867248471
-
-
MCNPX 2.3.0 User's Guide Report LA-UR-02-2607 Los Alamos National Laboratory
-
MCNPX 2002 MCNPX 2.3.0 User's Guide Report LA-UR-02-2607 Los Alamos National Laboratory
-
(2002)
Report
-
-
-
28
-
-
84867278150
-
-
MCNPX MCNPX 2.6.0 Users's Guide Report LA-CP-07-1473 Los Alamos National Laboratory
-
MCNPX 2008 MCNPX 2.6.0 Users's Guide Report LA-CP-07-1473 Los Alamos National Laboratory
-
(2008)
Report
-
-
-
29
-
-
33750744100
-
Prompt gamma measurements for locating the dose falloff region in the proton therapy
-
DOI 10.1063/1.2378561
-
Min C-H, Kim C H, Youn M-Y and Kim J-W 2006 Prompt gamma measurements for locating the dose fall-off region in the proton therapy Appl. Phys. Lett. 89 183517 (Pubitemid 44705775)
-
(2006)
Applied Physics Letters
, vol.89
, Issue.18
, pp. 183517
-
-
Min, C.-H.1
Kim, C.H.2
Youn, M.-Y.3
Kim, J.-W.4
-
30
-
-
79551706093
-
Monte Carlo patient study on the comparison of prompt gamma and PET imaging for range verification in proton therapy
-
10.1088/0031-9155/56/4/012 0031-9155
-
Moteabbed M, Espana S and Paganetti H 2011 Monte Carlo patient study on the comparison of prompt gamma and PET imaging for range verification in proton therapy Phys. Med. Biol. 56 1063-82
-
(2011)
Phys. Med. Biol.
, vol.56
, Issue.4
, pp. 1063-1082
-
-
Moteabbed, M.1
Espana, S.2
Paganetti, H.3
-
31
-
-
84879910259
-
The Heidelberg Ion Therapy (HIT) acceleration coming into operation
-
Ondreka D and Weinrich U 2008 The Heidelberg Ion Therapy (HIT) acceleration coming into operation Proc. Eur. Phys. Soc. Accelerator Group (Genoa, Italy,) pp 979-81
-
(2008)
Proc. Eur. Phys. Soc. Accelerator Group
, pp. 979-981
-
-
Ondreka, D.1
Weinrich, U.2
-
32
-
-
12144289318
-
The PSI Gantry 2: A second generation proton scanning gantry
-
Pedroni E et al 2004 The PSI gantry 2: a second generation proton scanning gantry Z. Med. Phys. 14 25-34 (Pubitemid 38435678)
-
(2004)
Zeitschrift fur Medizinische Physik
, vol.14
, Issue.1
, pp. 25-34
-
-
Pedroni, E.1
Bearpark, R.2
Bohringer, T.3
Coray, A.4
Duppich, J.5
Forss, S.6
George, D.7
Grossmann, M.8
Goitein, G.9
Hilbes, C.10
Jermann, M.11
Lin, S.12
Lomax, A.13
Negrazus, M.14
Schippers, M.15
Kotrle, G.16
-
33
-
-
84858667537
-
Application of the HICAM camera for imaging of prompt gamma rays in measurements of proton beam range
-
Peloso R, Busca P, Fiorini C, Basilavecchia M, Frizzi T, Smeets J, Roellinghoff F, Prieels D, Stichelbaut F and Benilov A 2011 Application of the HICAM camera for imaging of prompt gamma rays in measurements of proton beam range IEEE Nucl. Sci. Symp. Conf. Record pp 2285-9
-
(2011)
IEEE Nucl. Sci. Symp. Conf. Record
, pp. 2285-2289
-
-
Peloso, R.1
Busca, P.2
Fiorini, C.3
Basilavecchia, M.4
Frizzi, T.5
Smeets, J.6
Roellinghoff, F.7
Prieels, D.8
Stichelbaut, F.9
Benilov, A.10
-
34
-
-
78649991101
-
Optimizing a three-stage Compton camera for measuring prompt gamma rays emitted during proton radiotherapy
-
10.1088/0031-9155/55/22/015 0031-9155
-
Peterson S W, Robertson D and Polf J 2010 Optimizing a three-stage Compton camera for measuring prompt gamma rays emitted during proton radiotherapy Phys. Med. Biol. 55 6841-56
-
(2010)
Phys. Med. Biol.
, vol.55
, Issue.22
, pp. 6841-6856
-
-
Peterson, S.W.1
Robertson, D.2
Polf, J.3
-
35
-
-
63649163681
-
Prompt gamma-ray emission from biological tissues during proton irradiation: A preliminary study
-
10.1088/0031-9155/54/3/017 0031-9155
-
Polf J C, Peterson S, Ciangaru G, Gillin M and Beddar S 2009a Prompt gamma-ray emission from biological tissues during proton irradiation: a preliminary study Phys. Med. Biol. 54 731-43
-
(2009)
Phys. Med. Biol.
, vol.54
, Issue.3
, pp. 731-743
-
-
Polf, J.C.1
Peterson, S.2
Ciangaru, G.3
Gillin, M.4
Beddar, S.5
-
36
-
-
72249111598
-
Measurement and calculation of characteristic prompt gamma ray spectra emitted during proton irradiation
-
0031-9155 N02
-
Polf J C, Peterson S, McCleskey M, Roeder B T, Spiridon A, Beddar S and Trache L 2009b Measurement and calculation of characteristic prompt gamma ray spectra emitted during proton irradiation Phys. Med. Biol. 54 N519-27
-
(2009)
Phys. Med. Biol.
, vol.54
, Issue.22
-
-
Polf, J.C.1
Peterson, S.2
McCleskey, M.3
Roeder, B.T.4
Spiridon, A.5
Beddar, S.6
Trache, L.7
-
37
-
-
79959375306
-
Time-based readout of a silicon photomultiplier (SiPM) for time of flight positron emission tomography (TOF-PET)
-
10.1109/TNS.2011.2119493 0018-9499
-
Powolny F et al 2011 Time-based readout of a silicon photomultiplier (SiPM) for time of flight positron emission tomography (TOF-PET) IEEE Trans. Nucl. Sci. 58 597-604
-
(2011)
IEEE Trans. Nucl. Sci.
, vol.58
, Issue.3
, pp. 597-604
-
-
Powolny, F.1
-
38
-
-
84907196679
-
Towards a practical solution for real-time measurement of the proton beam range in patients
-
Prieels D, Smeets J, Stichelbaut F, Benilov A, Dehaes J C, Dubus A and Roellinghoff F 2011 Towards a practical solution for real-time measurement of the proton beam range in patients 50th Particle Therapy Co-Operative Group (PTCOG) Meeting (Philadelphia, PA, 8-14 May 2011)
-
(2011)
50th Particle Therapy Co-Operative Group (PTCOG) Meeting (Philadelphia, PA, 8-14 May 2011)
-
-
Prieels, D.1
Smeets, J.2
Stichelbaut, F.3
Benilov, A.4
Dehaes, J.C.5
Dubus, A.6
Roellinghoff, F.7
-
39
-
-
79955453982
-
Material efficiency studies for a Compton camera designed to measure characteristic prompt gamma rays emitted during proton beam radiotherapy
-
10.1088/0031-9155/56/10/010 0031-9155
-
Robertson D, Polf J C, Peterson S W, Gillin M T and Beddar S 2011 Material efficiency studies for a Compton camera designed to measure characteristic prompt gamma rays emitted during proton beam radiotherapy Phys. Med. Biol. 56 3047-39
-
(2011)
Phys. Med. Biol.
, vol.56
, Issue.10
, pp. 3047-3039
-
-
Robertson, D.1
Polf, J.C.2
Peterson, S.W.3
Gillin, M.T.4
Beddar, S.5
-
40
-
-
79960847098
-
Design of Compton camera for 3D prompt-γ imaging during ion beam therapy
-
10.1016/j.nima.2011.01.069 0168-9002 A
-
Roellinghoff F et al 2011 Design of Compton camera for 3D prompt-γ imaging during ion beam therapy Nucl. Instrum. Methods Phys. Res. A 648 S20-3
-
(2011)
Nucl. Instrum. Methods Phys. Res.
, vol.648
-
-
Roellinghoff, F.1
-
41
-
-
84867281895
-
Real-time proton beam range monitoring by means of prompt-gamma detection with a collimated camera
-
10.1016/S0167-8140(12)70203-7 0167-8140
-
Roellinghoff F et al 2012 Real-time proton beam range monitoring by means of prompt-gamma detection with a collimated camera Radiother. Oncol. 102 S120
-
(2012)
Radiother. Oncol.
, vol.102
, pp. 120
-
-
Roellinghoff, F.1
-
42
-
-
77956336204
-
An MCNPX Monte Carlo model of a discrete spot scanning proton beam therapy nozzle
-
10.1118/1.3476458 0094-2405
-
Sawakuchi G O, Mirkovic D, Perles L A, Sahoo N, Zhu X R, Ciangaru G, Suzuki K, Gillin M T, Mohan R and Titt U 2010 An MCNPX Monte Carlo model of a discrete spot scanning proton beam therapy nozzle Med. Phys. 37 4960-70
-
(2010)
Med. Phys.
, vol.37
, Issue.9
, pp. 4960-4970
-
-
Sawakuchi, G.O.1
Mirkovic, D.2
Perles, L.A.3
Sahoo, N.4
Zhu, X.R.5
Ciangaru, G.6
Suzuki, K.7
Gillin, M.T.8
Mohan, R.9
Titt, U.10
-
43
-
-
84858032555
-
Monte Carlo calculations of positron emitter yields in proton radiotherapy
-
10.1088/0031-9155/57/6/1659 0031-9155
-
Seravalli E et al 2012 Monte Carlo calculations of positron emitter yields in proton radiotherapy Phys. Med. Biol. 57 1659-73
-
(2012)
Phys. Med. Biol.
, vol.57
, Issue.6
, pp. 1659-1673
-
-
Seravalli, E.1
-
44
-
-
84973120236
-
Beam delivery systems for particle radiation therapy: Current status and recent developments
-
10.1142/S1793626809000211 1793-6268
-
Schippers J M 2009 Beam delivery systems for particle radiation therapy: current status and recent developments Rev. Accel. Sci. Technol. 2 179-200
-
(2009)
Rev. Accel. Sci. Technol.
, vol.2
, Issue.1
, pp. 179-200
-
-
Schippers, J.M.1
-
45
-
-
34247860977
-
Effectiveness of carbon ion radiotherapy in the treatment of skull-base chordomas
-
DOI 10.1016/j.ijrobp.2006.12.059, PII S0360301606036698
-
Schulz-Ertner D, Karger C, Feurhake H, Nikoghosyan A, Combs S E, Jäkel O, Edler L, Scholz M and Debus J 2007 Effectiveness of carbon ion radiotherapy in the treatment of skull-base chordomas Int. J. Radiat. Oncol. Biol. Phys. 68 449-57 (Pubitemid 46694169)
-
(2007)
International Journal of Radiation Oncology Biology Physics
, vol.68
, Issue.2
, pp. 449-457
-
-
Schulz-Ertner, D.1
Karger, C.P.2
Feuerhake, A.3
Nikoghosyan, A.4
Combs, S.E.5
Jakel, O.6
Edler, L.7
Scholz, M.8
Debus, J.9
-
46
-
-
84867270946
-
Optimized therapy strategies for locally advanced adenoid cystic carcinomas using modern radiation therapy techniques
-
10.1016/j.ijrobp.2004.07.443 0360-3016
-
Schulz-Ertner D, Nikoghosyan A, Muenter M, Jäkel O, Karger C and Debus J 2004 Optimized therapy strategies for locally advanced adenoid cystic carcinomas using modern radiation therapy techniques Int. J. Radiat. Oncol. Biol. Phys. 60 S504
-
(2004)
Int. J. Radiat. Oncol. Biol. Phys.
, vol.60
, Issue.1
, pp. 504
-
-
Schulz-Ertner, D.1
Nikoghosyan, A.2
Muenter, M.3
Jäkel, O.4
Karger, C.5
Debus, J.6
-
47
-
-
84859345932
-
3:Ce crystals on silicon photomultiplier arrays for time-of-flight positron emission tomography
-
10.1088/0031-9155/57/8/2219 0031-9155
-
3:Ce crystals on silicon photomultiplier arrays for time-of-flight positron emission tomography Phys. Med. Biol. 57 2219-33
-
(2012)
Phys. Med. Biol.
, vol.57
, Issue.8
, pp. 2219-2233
-
-
Seifert, S.1
Huizenga, J.2
Van Dam, H.T.3
Vinke, R.4
Dendooven, P.5
Löhner, H.6
Beekman, F.J.7
Schaart, D.R.8
-
48
-
-
84858787696
-
The lower bound on the timing resolution of photon counting scintillation detectors
-
10.1088/0031-9155/57/7/1797 0031-9155
-
Seifert S, van Dam H T and Schaart D R 2012b The lower bound on the timing resolution of photon counting scintillation detectors Phys. Med. Biol. 57 1797-814
-
(2012)
Phys. Med. Biol.
, vol.57
, Issue.7
, pp. 1797-1814
-
-
Seifert, S.1
Van Dam, H.T.2
Schaart, D.R.3
-
49
-
-
84867243676
-
Prompt gamma imaging with a slit camera for real time range control in proton therapy
-
10.1016/S0167-8140(12)70065-8 0167-8140
-
Smeets J et al 2012a Prompt gamma imaging with a slit camera for real time range control in proton therapy Radiother. Oncol. 102 S32-3
-
(2012)
Radiother. Oncol.
, vol.102
-
-
Smeets, J.1
-
50
-
-
84861115936
-
Prompt gamma imaging with a slit camera for real-time range control in proton therapy
-
10.1088/0031-9155/57/11/3371 0031-9155
-
Smeets J et al 2012b Prompt gamma imaging with a slit camera for real-time range control in proton therapy Phys. Med. Biol. 57 3371-405
-
(2012)
Phys. Med. Biol.
, vol.57
, Issue.11
, pp. 3371-3405
-
-
Smeets, J.1
-
51
-
-
51349141711
-
Monitoring the Bragg peak location of 73 MeV/u carbon ions by means of prompt gamma-ray measurement
-
10.1063/1.2975841 0003-6951 093506
-
Testa E, Bajard M, Chevallier M, Dauvergne D, Le Foulher F, Freud N, Létang J-M, Poizat J-C, Ray C and Testa M 2008 Monitoring the Bragg peak location of 73 MeV/u carbon ions by means of prompt gamma-ray measurement Appl. Phys. Lett. 93 093506
-
(2008)
Appl. Phys. Lett.
, vol.93
, Issue.9
-
-
Testa, E.1
Bajard, M.2
Chevallier, M.3
Dauvergne, D.4
Le Foulher, F.5
Freud, N.6
Létang, J.-M.7
Poizat, J.-C.8
Ray, C.9
Testa, M.10
-
52
-
-
77955467857
-
Real-time monitoring of the Bragg-peak position in ion therapy by means of single photon detection
-
10.1007/s00411-010-0276-2 0301-634X
-
Testa M et al 2010 Real-time monitoring of the Bragg-peak position in ion therapy by means of single photon detection Radiat. Environ. Biophys. 49 337-43
-
(2010)
Radiat. Environ. Biophys.
, vol.49
, Issue.3
, pp. 337-343
-
-
Testa, M.1
-
54
-
-
84867271565
-
-
private communicatio, Los Alamos National Laboratory
-
Waters L S 2010 private communication, Los Alamos National Laboratory
-
(2010)
-
-
Waters, L.S.1
|