메뉴 건너뛰기




Volumn 49, Issue 3, 2010, Pages 337-343

Real-time monitoring of the Bragg-peak position in ion therapy by means of single photon detection

Author keywords

[No Author keywords available]

Indexed keywords

CLINICAL CONDITIONS; DETECTED PHOTONS; HIGH ENERGY; ION RANGES; ION THERAPY; NONINVASIVE TECHNIQUE; NUCLEAR FRAGMENTATION; PEAK POSITION; PROMPT NEUTRONS; REAL TIME MONITORING; SINGLE PHOTON DETECTION; SINGLE PHOTONS; TIME OF FLIGHT MEASUREMENTS; WATER PHANTOM;

EID: 77955467857     PISSN: 0301634X     EISSN: None     Source Type: Journal    
DOI: 10.1007/s00411-010-0276-2     Document Type: Article
Times cited : (88)

References (13)
  • 2
    • 21444447195 scopus 로고    scopus 로고
    • Dose quantification from in-beam positron emission tomography
    • 10.1016/S0167-8140(04)80024-0
    • W Enghardt K Parodi P Crespo F Fiedler J Pawelke F Pönisch 2004 Dose quantification from in-beam positron emission tomography Radioth Oncol 73 96 98 10.1016/S0167-8140(04)80024-0
    • (2004) Radioth Oncol , vol.73 , pp. 96-98
    • Enghardt, W.1    Parodi, K.2    Crespo, P.3    Fiedler, F.4    Pawelke, J.5    Pönisch, F.6
  • 3
    • 48249099278 scopus 로고    scopus 로고
    • Secondary beam fragments produced by 200 MeV/u 12C ions in water and their dose contributions in carbon ion radiotherapy
    • 10.1088/1367-2630/10/7/075003
    • K Gunzert-Marx H Iwase D Schardt RS Simon 2008 Secondary beam fragments produced by 200 MeV/u 12C ions in water and their dose contributions in carbon ion radiotherapy New J Phys 10 075003 10.1088/1367-2630/10/7/075003
    • (2008) New J Phys , vol.10 , pp. 075003
    • Gunzert-Marx, K.1    Iwase, H.2    Schardt, D.3    Simon, R.S.4
  • 4
    • 0033773556 scopus 로고    scopus 로고
    • Treatment planning for heavy-ion radiotherapy: Physical beam model and dose optimization
    • 10.1088/0031-9155/45/11/313
    • M Kraemer O Jakel T Haberer G Kraft D Schardt U Weber 2000 Treatment planning for heavy-ion radiotherapy: physical beam model and dose optimization Phys Med Biol 45 3299 3317 10.1088/0031-9155/45/11/313
    • (2000) Phys Med Biol , vol.45 , pp. 3299-3317
    • Kraemer, M.1    Jakel, O.2    Haberer, T.3    Kraft, G.4    Schardt, D.5    Weber, U.6
  • 5
    • 0034506342 scopus 로고    scopus 로고
    • Tumor therapy with heavy charged particles
    • DOI 10.1016/S0146-6410(00)00112-5
    • G Kraft 2000 Tumor therapy with heavy charged particles Prog Part Nucl Phys 45 S473 S544 10.1016/S0146-6410(00)00112-5 2000PrPNP..45..473K (Pubitemid 32076531)
    • (2000) Progress in Particle and Nuclear Physics , vol.45 , Issue.SUPPL. 2
    • Kraft, G.1
  • 6
    • 79953804939 scopus 로고    scopus 로고
    • Monte Carlo simulations of prompt-gamma emission during carbon ion irradiation
    • Accepted for
    • Le Foulher F, Bajard M, Chevallier M, Dauvergne D, Freud N, Henriquet P, Karkar S, Létang JM, Plescak R, Ray C, Schardt D, Testa E, Testa M (2010) Monte Carlo simulations of prompt-gamma emission during carbon ion irradiation. Accepted for publication in IEEE Transactions on Nuclear Science
    • (2010) Publication in IEEE Transactions on Nuclear Science
    • Le Foulher F, B.1
  • 7
    • 33750744100 scopus 로고    scopus 로고
    • Prompt gamma measurements for locating the dose falloff region in the proton therapy
    • DOI 10.1063/1.2378561
    • C-H Min CH Kim M-Y Youn J-W Kim 2006 Prompt gamma measurements for locating the dose falloff region in proton therapy Appl Phys Lett 89 183517 10.1063/1.2378561 2006ApPhL..89r3517M (Pubitemid 44705775)
    • (2006) Applied Physics Letters , vol.89 , Issue.18 , pp. 183517
    • Min, C.-H.1    Kim, C.H.2    Youn, M.-Y.3    Kim, J.-W.4
  • 9
    • 44649187801 scopus 로고    scopus 로고
    • PET imaging for treatment verification of ion therapy: Implementation and experience at GSI Darmstadt and MGH Boston
    • 10.1016/j.nima.2008.03.075 2008NIMPA.591.282P
    • K Parodi T Bortfeld W Enghardt F Fiedler A Knopf H Paganetti J Pawelke G Shakirin H Shih 2008 PET imaging for treatment verification of ion therapy: Implementation and experience at GSI Darmstadt and MGH Boston Nucl Instr Meth A 591 282 286 10.1016/j.nima.2008.03.075 2008NIMPA.591..282P
    • (2008) Nucl Instr Meth A , vol.591 , pp. 282-286
    • Parodi, K.1    Bortfeld, T.2    Enghardt, W.3    Fiedler, F.4    Knopf, A.5    Paganetti, H.6    Pawelke, J.7    Shakirin, G.8    Shih, H.9
  • 10
    • 45149145456 scopus 로고
    • 158Gd at 44 MeV/u
    • 1989NuPhA.495.49R
    • 158Gd at 44 MeV/u Nucl Phys A49 5 49c 56c 1989NuPhA.495...49R
    • (1989) Nucl Phys , vol.49 , Issue.5
    • Riess, S.1
  • 11
    • 33747627407 scopus 로고    scopus 로고
    • Investigating the accuracy of the FLUKA code for transport of therapeutic ion beams in matter
    • DOI 10.1088/0031-9155/51/17/017, PII S0031915506180471, 017
    • F Sommerer K Parodi A Ferrari K Poljanc W Enghardt H Aiginger 2006 Investigating the accuracy of the FLUKA code for transport of therapeutic ion beams in matter Phys Med Biol 51 4385 4398 10.1088/0031-9155/51/17/017 (Pubitemid 44261851)
    • (2006) Physics in Medicine and Biology , vol.51 , Issue.17 , pp. 4385-4398
    • Sommerer, F.1    Parodi, K.2    Ferrari, A.3    Poljanc, K.4    Enghardt, W.5    Aiginger, H.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.