메뉴 건너뛰기




Volumn 56, Issue 10, 2011, Pages 3047-3059

Material efficiency studies for a Compton camera designed to measure characteristic prompt gamma rays emitted during proton beam radiotherapy

Author keywords

[No Author keywords available]

Indexed keywords

BIOLOGICAL RESPONSE; BIOLOGICAL TISSUES; BISMUTH GERMANATE; CAMERA DESIGN; COMPTON CAMERA; DETECTION EFFICIENCY; DETECTOR MATERIALS; GAMMA ENERGY; INITIAL STAGES; IRRADIATED TISSUE; LANTHANUM BROMIDE; MATERIAL EFFICIENCY; PROMPT GAMMA-RAYS; PROTON BEAM RADIOTHERAPY; PROTON THERAPY; SPECTROSCOPIC INFORMATION; TREATMENT VERIFICATION; TWO STAGE;

EID: 79955453982     PISSN: 00319155     EISSN: 13616560     Source Type: Journal    
DOI: 10.1088/0031-9155/56/10/010     Document Type: Article
Times cited : (42)

References (21)
  • 2
    • 0018224762 scopus 로고
    • Visualization and transport of positron emission from proton activation in vivo
    • Bennett G W, Archambeau J O, Archambeau B E, Meltzer J I and Wingate C L 1978 Visualization and transport of positron emission from proton activation in vivo Science 200 1151-3 (Pubitemid 9087499)
    • (1978) Science , vol.200 , Issue.4346 , pp. 1151-1153
    • Bennett, G.W.1    Archambeau, J.O.2    Archambeau, B.E.3
  • 5
    • 77950644889 scopus 로고    scopus 로고
    • A tracking Compton-scattering imaging system for hadron therapy monitoring
    • Frandes M, Zoglauer A, Maxim V and Prost R 2010 A tracking Compton-scattering imaging system for hadron therapy monitoring IEEE Trans. Nucl. Sci. 57 144-50
    • (2010) IEEE Trans. Nucl. Sci. , vol.57 , Issue.1 , pp. 144-150
    • Frandes, M.1    Zoglauer, A.2    Maxim, V.3    Prost, R.4
  • 6
    • 79955365792 scopus 로고    scopus 로고
    • International Commission on Radiation Units and Measurements (ICRU)
    • International Commission on Radiation Units and Measurements (ICRU) 2007 Tissue substitutes in radiation dosimetry and measurement ICRU Report No. 44 (Bethesda, MD: ICRU)
    • (2007) Tissue Substitutes in Radiation Dosimetry and Measurement
  • 7
    • 70350326258 scopus 로고    scopus 로고
    • Preliminary study for determination of distal dose edge by measuring 90 deg prompt gammas with an array-type prompt gamma detection system
    • Min C H, Park J G and Kim C H 2009 Preliminary study for determination of distal dose edge by measuring 90 deg prompt gammas with an array-type prompt gamma detection system Nucl. Technol. 168 89-92
    • (2009) Nucl. Technol. , vol.168 , pp. 89-92
    • Min, C.H.1    Park, J.G.2    Kim, C.H.3
  • 8
    • 0003625463 scopus 로고
    • National Council on Radiation Protection and Measurements (NCRP)
    • National Council on Radiation Protection and Measurements (NCRP) 1971 Protection against neutron radiation NCRP Report No. 38 (Bethesda, MD: NCRP)
    • (1971) Protection Against Neutron Radiation
  • 9
    • 79955422995 scopus 로고    scopus 로고
    • Characterizing secondary gamma fluence from a scanned beam proton therapy nozzle
    • Peterson S and Polf J 2009 Characterizing secondary gamma fluence from a scanned beam proton therapy nozzle Med. Phys. 36 2613
    • (2009) Med. Phys. , vol.36 , Issue.6 , pp. 2613
    • Peterson, S.1    Polf, J.2
  • 10
    • 68149166775 scopus 로고    scopus 로고
    • Variations in proton scanned beam dose delivery due to uncertainties in magnetic beam steering
    • Peterson S, Polf J, Ciangaru G, Frank S J, Bues M and Smith A 2009 Variations in proton scanned beam dose delivery due to uncertainties in magnetic beam steering Med. Phys. 36 3693-702
    • (2009) Med. Phys. , vol.36 , Issue.8 , pp. 3693-3702
    • Peterson, S.1    Polf, J.2    Ciangaru, G.3    Frank, S.J.4    Bues, M.5    Smith, A.6
  • 11
    • 78649991101 scopus 로고    scopus 로고
    • Optimizing a three-stage Compton camera for measuring prompt gamma rays emitted during proton radiotherapy
    • Peterson S, Robertson D and Polf J 2010 Optimizing a three-stage Compton camera for measuring prompt gamma rays emitted during proton radiotherapy Phys. Med. Biol. 55 6841
    • (2010) Phys. Med. Biol. , vol.55 , Issue.22 , pp. 6841
    • Peterson, S.1    Robertson, D.2    Polf, J.3
  • 12
    • 0038203963 scopus 로고
    • Gamma-ray imaging with Compton cameras
    • Phillips G W 1995 Gamma-ray imaging with Compton cameras Nucl. Instrum. Methods Phys. Res. B 99 674-7
    • (1995) Nucl. Instrum. Methods Phys. Res. , vol.99 , Issue.1-4 , pp. 674-677
    • Phillips, G.W.1
  • 13
    • 63649163681 scopus 로고    scopus 로고
    • Prompt gamma-ray emission from biological tissues during proton irradiation: A preliminary study
    • Polf J C, Peterson S, Ciangaru G, Gillin M and Beddar S 2009a Prompt gamma-ray emission from biological tissues during proton irradiation: a preliminary study Phys. Med. Biol. 54 731-43
    • (2009) Phys. Med. Biol. , vol.54 , Issue.3 , pp. 731-743
    • Polf, J.C.1    Peterson, S.2    Ciangaru, G.3    Gillin, M.4    Beddar, S.5
  • 15
    • 77951162268 scopus 로고    scopus 로고
    • Design study of a Compton camera for prompt gamma imaging during ion beam therapy
    • Richard M H et al 2009 Design study of a Compton camera for prompt gamma imaging during ion beam therapy Nuclear Science Symp. Conf. Record (NSS/MIC), IEEE 2009 pp 4172-5
    • (2009) Nuclear Science Symp. Conf. Record (NSS/MIC), IEEE 2009 , pp. 4172-4175
    • Richard, M.H.1
  • 17
    • 69549138159 scopus 로고    scopus 로고
    • The M D Anderson proton therapy system
    • Smith A et al 2009 The M D Anderson proton therapy system Med. Phys. 36 4068-83
    • (2009) Med. Phys. , vol.36 , Issue.9 , pp. 4068-4083
    • Smith, A.1
  • 18
    • 0024123991 scopus 로고
    • Gamma-ray imaging with silicon detectors-a Compton camera for radionuclide imaging in medicine
    • Solomon C J and Ott R J 1988 Gamma-ray imaging with silicon detectors-a Compton camera for radionuclide imaging in medicine Nucl. Instrum. Methods Phys. Res. A 273 787-92
    • (1988) Nucl. Instrum. Methods Phys. Res. , vol.273 , Issue.2-3 , pp. 787-792
    • Solomon, C.J.1    Ott, R.J.2
  • 19
    • 0025961224 scopus 로고
    • A feasibility study for the simultaneous measurement of carbon, hydrogen and oxygen using pulsed 14.4 Mev neutrons
    • Sutcliffe J F, Waker A J, Smith A H, Barker M C J and Smith M A 1991 A feasibility study for the simultaneous measurement of carbon, hydrogen and oxygen using pulsed 14.4 Mev neutrons Phys. Med. Biol. 36 87-98
    • (1991) Phys. Med. Biol. , vol.36 , Issue.1 , pp. 87-98
    • Sutcliffe, J.F.1    Waker, A.J.2    Smith, A.H.3    Barker, M.C.J.4    Smith, M.A.5
  • 20
    • 69949089184 scopus 로고    scopus 로고
    • Dose profile monitoring with carbon ions by means of prompt-gamma measurements
    • Testa E et al 2009 Dose profile monitoring with carbon ions by means of prompt-gamma measurements Nucl. Instrum. Methods Phys. Res. B 267 993-6
    • (2009) Nucl. Instrum. Methods Phys. Res. , vol.267 , Issue.6 , pp. 993-996
    • Testa, E.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.