메뉴 건너뛰기




Volumn , Issue , 2011, Pages 2285-2289

Application of the HICAM camera for imaging of prompt gamma rays in measurements of proton beam range

Author keywords

[No Author keywords available]

Indexed keywords

CAMERAS; CLINICAL RESEARCH; MEDICAL IMAGING; NUCLEAR MEDICINE; PROTON BEAMS; SILICON DETECTORS;

EID: 84858667537     PISSN: 10957863     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/NSSMIC.2011.6153863     Document Type: Conference Paper
Times cited : (7)

References (11)
  • 1
    • 70350562115 scopus 로고    scopus 로고
    • Derivation of system matrix from simulation data for an animal SPECT with slit-slat collimator
    • October
    • R. Yao, T. Ma, and Y. Shao, "Derivation of system matrix from simulation data for an animal SPECT with slit-slat collimator", IEEE Trans. Nucl. Sci., vol. 56, pp. 2651-2658, October 2009.
    • (2009) IEEE Trans. Nucl. Sci. , vol.56 , pp. 2651-2658
    • Yao, R.1    Ma, T.2    Shao, Y.3
  • 4
    • 70350553232 scopus 로고    scopus 로고
    • A SVD-based method to assess the uniqueness and accuracy of SPECT geometrical calibration
    • T. Ma, R. Yao, Y. Shao, and R. Zhou, "A SVD-based method to assess the uniqueness and accuracy of SPECT geometrical calibration", IEEE Trans. Med. Imag., vol. 28, pp. 1929-1939, 2009.
    • (2009) IEEE Trans. Med. Imag. , vol.28 , pp. 1929-1939
    • Ma, T.1    Yao, R.2    Shao, Y.3    Zhou, R.4
  • 7
    • 39049163745 scopus 로고    scopus 로고
    • Verification of the sensitivity and resolution dependence on the incidence angle for slit-slat collimation
    • Feb.
    • J. R. Novak, A. S. Ayan, R. Accorsi, and S. D. Metzler, "Verification of the sensitivity and resolution dependence on the incidence angle for slit-slat collimation", Phys. Med. Biol., vol. 53, pp. 953-966, Feb. 2008.
    • (2008) Phys. Med. Biol. , vol.53 , pp. 953-966
    • Novak, J.R.1    Ayan, A.S.2    Accorsi, R.3    Metzler, S.D.4
  • 8
    • 84858677821 scopus 로고    scopus 로고
    • Slit-aperture collimator calibration for SPECT imaging on microPET
    • T. Ma, R. Yao, and Y. Shao, "Slit-aperture collimator calibration for SPECT imaging on microPET", J. Nucl. Med., vol. 48, p. 442P, 2007.
    • (2007) J. Nucl. Med. , vol.48
    • Ma, T.1    Yao, R.2    Shao, Y.3
  • 9
    • 51849109066 scopus 로고    scopus 로고
    • Lutetium oxyorthosilicate (LSO) intrinsic activity correction and minimal detectable target activity study for SPECT imaging with a LSO-based animal PET scanner
    • R. Yao, T. Ma, and Y. Shao, "Lutetium oxyorthosilicate (LSO) intrinsic activity correction and minimal detectable target activity study for SPECT imaging with a LSO-based animal PET scanner", Phys. Med. Biol., vol. 53, pp. 4399-4415, 2008.
    • (2008) Phys. Med. Biol. , vol.53 , pp. 4399-4415
    • Yao, R.1    Ma, T.2    Shao, Y.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.