메뉴 건너뛰기




Volumn 56, Issue 5, 2009, Pages 2580-2585

Multi-pixel photon counters for TOF PET detector and its challenges

Author keywords

Avalanche photodiode; Coincidence timing resolution; Geiger mode; Solid state photomultiplier

Indexed keywords

BLOCK DETECTORS; COINCIDENCE TIMING RESOLUTION; DARK COUNTS; DETECTOR SYSTEMS; ELECTRONIC NOISE; EXPECTED IMPROVEMENTS; GEIGER MODE; GEIGER MODE AVALANCHE PHOTO DIODES; GENERATION TIME; LYSO CRYSTALS; MULTI-PIXEL PHOTON COUNTERS; MULTIPLE DEVICES; OVER-VOLTAGES; PET DETECTORS; PHOTON DETECTION EFFICIENCY; PULSE SHAPES; SUB-PIXELS; TIME-OF-FLIGHT PET; TIMING PERFORMANCE; TIMING RESOLUTIONS; TRANSIT TIME SPREAD; TRIGGER THRESHOLD;

EID: 70350176156     PISSN: 00189499     EISSN: None     Source Type: Journal    
DOI: 10.1109/TNS.2009.2028075     Document Type: Article
Times cited : (78)

References (16)
  • 3
    • 33750392737 scopus 로고    scopus 로고
    • New prospects for time of flight PET with LSO scintillators
    • Oct.
    • M. Moszynski et al., "New prospects for time of flight PET with LSO scintillators," IEEE Trans. Nucl. Sci., vol.53, no.5, pp. 2484-2488, Oct. 2006.
    • (2006) IEEE Trans. Nucl. Sci. , vol.53 , Issue.5 , pp. 2484-2488
    • Moszynski, M.1
  • 4
    • 34250733371 scopus 로고    scopus 로고
    • Performance study of the new Hamamatsu R9779 & Photonis XP20D0 fast 2 Photomultipliers
    • Jun.
    • F. Bauer, M. Aykac, M. Loope, C. W. Williams, L. Eriksson, and M. Schmand, "Performance study of the new Hamamatsu R9779 & Photonis XP20D0 fast 2 Photomultipliers," IEEE Trans. Nucl. Sci., vol.54, no.3, pp. 422-426, Jun. 2007.
    • (2007) IEEE Trans. Nucl. Sci. , vol.54 , Issue.3 , pp. 422-426
    • Bauer, F.1    Aykac, M.2    Loope, M.3    Williams, C.W.4    Eriksson, L.5    Schmand, M.6
  • 5
    • 0033885849 scopus 로고    scopus 로고
    • Limited Geiger-mode microcell silicon photodiode: New results
    • G. Bondarenko et al., "Limited Geiger-mode microcell silicon photodiode: New results," Nucl. Instrum. Meth. Phys. Res. A, vol.442, pp. 187-192, 2000.
    • (2000) Nucl. Instrum. Meth. Phys. Res. A , vol.442 , pp. 187-192
    • Bondarenko, G.1
  • 6
    • 35348867409 scopus 로고    scopus 로고
    • Development of multi-pixel photon counter
    • S. Gomi et al., "Development of multi-pixel photon counter," Nucl. Instrum. Meth. Phys. Res. A, vol.581, pp. 427-432, 2007.
    • (2007) Nucl. Instrum. Meth. Phys. Res. A , vol.581 , pp. 427-432
    • Gomi, S.1
  • 7
    • 0142126690 scopus 로고    scopus 로고
    • Time-of-flight in PET revisited
    • Oct.
    • W. W. Moses, "Time-of-flight in PET revisited," IEEE Trans. Nucl. Sci., vol.50, no.5, pp. 1325-1330, Oct. 2003.
    • (2003) IEEE Trans. Nucl. Sci. , vol.50 , Issue.5 , pp. 1325-1330
    • Moses, W.W.1
  • 8
    • 40449116151 scopus 로고    scopus 로고
    • Benefits of time-of-flight in PET: Experimental and clinical results
    • Mar.
    • J. Karp, S. Surti, M. E. Daube-Witherspoon, and G. Muehllehner, "Benefits of time-of-flight in PET: Experimental and clinical results," J. Nucl. Med., vol.49, no.3, pp. 462-470, Mar. 2008.
    • (2008) J. Nucl. Med. , vol.49 , Issue.3 , pp. 462-470
    • Karp, J.1    Surti, S.2    Daube-Witherspoon, M.E.3    Muehllehner, G.4
  • 9
    • 33749362905 scopus 로고    scopus 로고
    • A measurement of the photon detection efficiency of silicon photomultipliers
    • A. N. Otte et al., "A measurement of the photon detection efficiency of silicon photomultipliers," Nucl. Instrum. Meth. Phys. Res. A, vol.567, pp. 360-363, 2006.
    • (2006) Nucl. Instrum. Meth. Phys. Res. A , vol.567 , pp. 360-363
    • Otte, A.N.1
  • 11
    • 0005213030 scopus 로고
    • Temperature dependence of breakdown voltage in silicon abrupt P-N junctions
    • Jun.
    • C. Y. Chang et al., "Temperature dependence of breakdown voltage in silicon abrupt P-N junctions," IEEE Trans. Electron. Dev., vol.18, no.6, pp. 391-393, Jun. 1971.
    • (1971) IEEE Trans. Electron. Dev. , vol.18 , Issue.6 , pp. 391-393
    • Chang, C.Y.1
  • 12
    • 0029358636 scopus 로고
    • Performance of a large scale scintillating fiber tracker using VLPC readout
    • D. Adams et al., "Performance of a large scale scintillating fiber tracker using VLPC readout," IEEE Trans. Nucl. Sci., vol.42, pp. 332-339, 1995.
    • (1995) IEEE Trans. Nucl. Sci. , vol.42 , pp. 332-339
    • Adams, D.1
  • 13
    • 33846895427 scopus 로고    scopus 로고
    • Modeling a silicon photomultiplier (SiPM) as a signal source for optimum front-end design
    • F. Corsi et al., "Modeling a silicon photomultiplier (SiPM) as a signal source for optimum front-end design," Nucl. Instrum. Meth. Phys. Res. A, vol.572, pp. 416-418, 2007.
    • (2007) Nucl. Instrum. Meth. Phys. Res. A , vol.572 , pp. 416-418
    • Corsi, F.1
  • 14
    • 33846612676 scopus 로고    scopus 로고
    • Gamma spectroscopy using a silicon photomultiplier and a scintillator
    • N. Pavlov, G. Mæhlum, and D. Meier, "Gamma spectroscopy using a silicon photomultiplier and a scintillator," in Proc. IEEE NSS-MIC Symp. Conf. Rec., 2005, pp. 173-180.
    • (2005) Proc. IEEE NSS-MIC Symp. Conf. Rec. , pp. 173-180
    • Pavlov, N.1    Mæhlum, G.2    Meier, D.3
  • 15
    • 0030121167 scopus 로고    scopus 로고
    • Avalanche photodiodes and quenching circuits for single-photon detection
    • S. Cova et al., "Avalanche photodiodes and quenching circuits for single-photon detection," Appl. Opt., vol.35, no.12, pp. 1956-1976, 1996.
    • (1996) Appl. Opt. , vol.35 , Issue.12 , pp. 1956-1976
    • Cova, S.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.