메뉴 건너뛰기




Volumn 38, Issue 10, 2012, Pages 1764-1770

Comparability and repeatability of corneal astigmatism measurements using different measurement technologies

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; AGED; ANALYSIS OF VARIANCE; ARTICLE; ASTIGMATISM; FEMALE; HUMAN; IMAGING SYSTEM; INTERMETHOD COMPARISON; KERATOMETER; KERATOMETRY; MALE; MEASUREMENT; NORMAL HUMAN; PRIORITY JOURNAL; REPEAT PROCEDURE; WAVEFRONT ANALYZER;

EID: 84866649001     PISSN: 08863350     EISSN: 18734502     Source Type: Journal    
DOI: 10.1016/j.jcrs.2012.05.036     Document Type: Article
Times cited : (100)

References (35)
  • 1
    • 34247464661 scopus 로고    scopus 로고
    • Rotational stability of a single-piece hydrophobic acrylic intraocular lens: New method for high-precision rotation control
    • DOI 10.1016/j.jcrs.2007.01.030, PII S0886335007002714
    • F. Weinand, A. Jung, A. Stein, A. Pfützner, R. Becker, and S. Pavlovic Rotational stability of a single-piece hydrophobic acrylic intraocular lens: new method for high-precision rotation control J Cataract Refract Surg 33 2007 800 803 (Pubitemid 46646979)
    • (2007) Journal of Cataract and Refractive Surgery , vol.33 , Issue.5 , pp. 800-803
    • Weinand, F.1    Jung, A.2    Stein, A.3    Pfutzner, A.4    Becker, R.5    Pavlovic, S.6
  • 3
    • 33845495864 scopus 로고    scopus 로고
    • Comparison of Different Techniques of Anterior Chamber Depth and Keratometric Measurements
    • DOI 10.1016/j.ajo.2006.08.031, PII S0002939406010154
    • U. Elbaz, Y. Barkana, Y. Gerber, I. Avni, and D. Zadok Comparison of different techniques of anterior chamber depth and keratometric measurements Am J Ophthalmol 143 2007 48 53 (Pubitemid 44917822)
    • (2007) American Journal of Ophthalmology , vol.143 , Issue.1 , pp. 48-53
    • Elbaz, U.1    Barkana, Y.2    Gerber, Y.3    Avni, I.4    Zadok, D.5
  • 5
    • 79952006708 scopus 로고    scopus 로고
    • Comparison of the ultrasonographic method with 2 partial coherence interferometry methods for intraocular lens power calculation
    • R. Salouti, M.H. Nowroozzadeh, M. Zamani, M. Ghoreyshi, and R. Salouti Comparison of the ultrasonographic method with 2 partial coherence interferometry methods for intraocular lens power calculation Optometry 82 2011 140 147
    • (2011) Optometry , vol.82 , pp. 140-147
    • Salouti, R.1    Nowroozzadeh, M.H.2    Zamani, M.3    Ghoreyshi, M.4    Salouti, R.5
  • 6
    • 67649803385 scopus 로고    scopus 로고
    • Accuracy of Scheimpflug corneal power measurements for intraocular lens power calculation
    • erratum, 1483
    • G. Savini, P. Barboni, M. Carbonelli, and K.J. Hoffer Accuracy of Scheimpflug corneal power measurements for intraocular lens power calculation J Cataract Refract Surg 35 2009 1193 1197 erratum, 1483
    • (2009) J Cataract Refract Surg , vol.35 , pp. 1193-1197
    • Savini, G.1    Barboni, P.2    Carbonelli, M.3    Hoffer, K.J.4
  • 7
    • 77958154061 scopus 로고    scopus 로고
    • Comparison of accuracy of intraocular lens calculations using automated keratometry, a Placido-based corneal topographer, and a combined Placido-based and dual Scheimpflug corneal topographer
    • M. Shirayama, L. Wang, D.D. Koch, and M.P. Weikert Comparison of accuracy of intraocular lens calculations using automated keratometry, a Placido-based corneal topographer, and a combined Placido-based and dual Scheimpflug corneal topographer Cornea 29 2010 1136 1138
    • (2010) Cornea , vol.29 , pp. 1136-1138
    • Shirayama, M.1    Wang, L.2    Koch, D.D.3    Weikert, M.P.4
  • 8
    • 84856469103 scopus 로고    scopus 로고
    • Keratometry evaluations with the Pentacam high resolution in comparison with the automated keratometry and conventional corneal topography
    • L. Módis Jr., E. Szalai, B. Kolozsvári, G. Németh, A. Vajas, and A. Berta Keratometry evaluations with the Pentacam high resolution in comparison with the automated keratometry and conventional corneal topography Cornea 31 2012 36 41
    • (2012) Cornea , vol.31 , pp. 36-41
    • Módis, Jr.L.1    Szalai, E.2    Kolozsvári, B.3    Németh, G.4    Vajas, A.5    Berta, A.6
  • 9
    • 78751555817 scopus 로고    scopus 로고
    • Automated keratometry in routine cataract surgery: Comparison of Scheimpflug and conventional values
    • R.J. Symes, and P.G. Ursell Automated keratometry in routine cataract surgery: comparison of Scheimpflug and conventional values J Cataract Refract Surg 37 2011 295 301
    • (2011) J Cataract Refract Surg , vol.37 , pp. 295-301
    • Symes, R.J.1    Ursell, P.G.2
  • 11
    • 0347357677 scopus 로고    scopus 로고
    • Practical astigmatism analysis for refractive outcomes in cataract and refractive surgery
    • DOI 10.1016/j.survophthal.2003.10.010
    • N.A. Alpins, and M. Goggin Practical astigmatism analysis for refractive outcomes in cataract and refractive surgery Surv Ophthalmol 49 2004 109 122 (Pubitemid 38056628)
    • (2004) Survey of Ophthalmology , vol.49 , Issue.1 , pp. 109-122
    • Alpins, N.A.1    Goggin, M.2
  • 12
    • 0030596840 scopus 로고    scopus 로고
    • Measurement error
    • [Statistic notes] Available at: Accessed June 18, 2012
    • J.M. Bland, and D.G. Altman Measurement error [Statistic notes] BMJ 313 1996 744 Available at: http://www.ncbi.nlm.nih.gov/pmc/articles/PMC2352111/pdf/ bmj00560-0056b.pdf Accessed June 18, 2012
    • (1996) BMJ , vol.313 , pp. 744
    • Bland, J.M.1    Altman, D.G.2
  • 13
    • 77950233865 scopus 로고    scopus 로고
    • Visual function and patient experience after bilateral implantation of toric intraocular lenses
    • for the Canadian Toric Study Group
    • I.I.K. Ahmed, G. Rocha, A.R. Slomovic, H. Climenhaga, J. Gohill, A. Grégoire, J. Ma for the Canadian Toric Study Group Visual function and patient experience after bilateral implantation of toric intraocular lenses J Cataract Refract Surg 36 2010 609 616
    • (2010) J Cataract Refract Surg , vol.36 , pp. 609-616
    • Ahmed, I.I.K.1    Rocha, G.2    Slomovic, A.R.3    Climenhaga, H.4    Gohill, J.5    Grégoire, A.6    Ma, J.7
  • 15
    • 78049314104 scopus 로고    scopus 로고
    • The AcrySof toric intraocular lens in subjects with cataracts and corneal astigmatism; A randomized, subject-masked, parallel-group, 1-year study
    • E. Holland, S. Lane, J.D. Horn, P. Ernest, R. Arleo, and K.M. Miller The AcrySof toric intraocular lens in subjects with cataracts and corneal astigmatism; a randomized, subject-masked, parallel-group, 1-year study Ophthalmology 117 2010 2104 2111
    • (2010) Ophthalmology , vol.117 , pp. 2104-2111
    • Holland, E.1    Lane, S.2    Horn, J.D.3    Ernest, P.4    Arleo, R.5    Miller, K.M.6
  • 16
    • 79955058545 scopus 로고    scopus 로고
    • Clinical results after spherotoric intraocular lens implantation using the Bag-In-The-Lens technique
    • M.-J. Tassignon, L. Gobin, D. Mathysen, and J. Van Looveren Clinical results after spherotoric intraocular lens implantation using the bag-in-the-lens technique J Cataract Refract Surg 37 2011 830 834
    • (2011) J Cataract Refract Surg , vol.37 , pp. 830-834
    • Tassignon, M.-J.1    Gobin, L.2    Mathysen, D.3    Van Looveren, J.4
  • 17
    • 79957775901 scopus 로고    scopus 로고
    • Cataract surgery with toric intraocular lens implantation in keratoconus: A case report
    • N. Visser, S.T.J.M. Gast, N.J.C. Bauer, and R.M.M.A. Nuijts Cataract surgery with toric intraocular lens implantation in keratoconus: a case report Cornea 30 2011 720 723
    • (2011) Cornea , vol.30 , pp. 720-723
    • Visser, N.1    Gast, S.T.J.M.2    Bauer, N.J.C.3    Nuijts, R.M.M.A.4
  • 18
    • 80051883545 scopus 로고    scopus 로고
    • Surgical and refractive outcomes of cataract surgery with toric intraocular lens implantation at a resident-teaching institution
    • B. Pouyeh, A. Galor, A.K. Junk, J. Pelletier, S.R. Wellik, N.Z. Gregori, and J. Trentacoste Surgical and refractive outcomes of cataract surgery with toric intraocular lens implantation at a resident-teaching institution J Cataract Refract Surg 37 2011 1623 1628
    • (2011) J Cataract Refract Surg , vol.37 , pp. 1623-1628
    • Pouyeh, B.1    Galor, A.2    Junk, A.K.3    Pelletier, J.4    Wellik, S.R.5    Gregori, N.Z.6    Trentacoste, J.7
  • 19
    • 0036218404 scopus 로고    scopus 로고
    • A new non-contact optical device for ocular biometry
    • DOI 10.1136/bjo.86.4.458
    • J. Santodomingo-Rubido, E.A.H. Mallen, B. Gilmartin, and J.S. Wolffsohn A new non-contact optical device for ocular biometry Br J Ophthalmol 86 2002 458 462 Available at: http://www.ncbi.nlm.nih.gov/pmc/articles/PMC1771084/pdf/ bjo08600458.pdf Accessed June 18, 2012 (Pubitemid 34293298)
    • (2002) British Journal of Ophthalmology , vol.86 , Issue.4 , pp. 458-462
    • Santodomingo-Rubido, J.1    Mallen, E.A.H.2    Gilmartin, B.3    Wolffsohn, J.S.4
  • 20
    • 0035140259 scopus 로고    scopus 로고
    • Power vector analysis of the optical outcome of refractive surgery
    • DOI 10.1016/S0886-3350(00)00797-5, PII S0886335000007975
    • L.N. Thibos, and D. Horner Power vector analysis of the optical outcome of refractive surgery J Cataract Refract Surg 27 2001 80 85 (Pubitemid 32116314)
    • (2001) Journal of Cataract and Refractive Surgery , vol.27 , Issue.1 , pp. 80-85
    • Thibos, L.N.1    Horner, D.2
  • 21
    • 67049116006 scopus 로고    scopus 로고
    • Corneal topography with Scheimpflug imaging and videokeratography: Comparative study of normal eyes
    • S.A. Read, M.J. Collins, D.R. Iskander, and B.A. Davis Corneal topography with Scheimpflug imaging and videokeratography: comparative study of normal eyes J Cataract Refract Surg 35 2009 1072 1081
    • (2009) J Cataract Refract Surg , vol.35 , pp. 1072-1081
    • Read, S.A.1    Collins, M.J.2    Iskander, D.R.3    Davis, B.A.4
  • 22
    • 84862823081 scopus 로고    scopus 로고
    • Comparison of corneal power, corneal astigmatism, and axis location in normal eyes obtained from an autokeratometer and a corneal topographer
    • H. Kobashi, K. Kamiya, A. Igarashi, R. Ishii, N. Sato, G. Wang, and K. Shimizu Comparison of corneal power, corneal astigmatism, and axis location in normal eyes obtained from an autokeratometer and a corneal topographer J Cataract Refract Surg 38 2012 648 654
    • (2012) J Cataract Refract Surg , vol.38 , pp. 648-654
    • Kobashi, H.1    Kamiya, K.2    Igarashi, A.3    Ishii, R.4    Sato, N.5    Wang, G.6    Shimizu, K.7
  • 23
    • 70349265986 scopus 로고    scopus 로고
    • Comparison of corneal powers obtained from 4 different devices
    • M. Shirayama, L. Wang, M.P. Weikert, and D.D. Koch Comparison of corneal powers obtained from 4 different devices Am J Ophthalmol 148 2009 528 535
    • (2009) Am J Ophthalmol , vol.148 , pp. 528-535
    • Shirayama, M.1    Wang, L.2    Weikert, M.P.3    Koch, D.D.4
  • 25
    • 70350567196 scopus 로고    scopus 로고
    • Comparison and evaluation of ocular biometry using a new noncontact optical low-coherence reflectometer
    • K. Rohrer, B.E. Frueh, R. Wälti, I.A. Clemetson, C. Tappeiner, and D. Goldblum Comparison and evaluation of ocular biometry using a new noncontact optical low-coherence reflectometer Ophthalmology 116 2009 2087 2092
    • (2009) Ophthalmology , vol.116 , pp. 2087-2092
    • Rohrer, K.1    Frueh, B.E.2    Wälti, R.3    Clemetson, I.A.4    Tappeiner, C.5    Goldblum, D.6
  • 26
    • 77950235684 scopus 로고    scopus 로고
    • Comparison of 2 laser instruments for measuring axial length
    • K.J. Hoffer, H.J. Shammas, and G. Savini Comparison of 2 laser instruments for measuring axial length J Cataract Refract Surg 36 2010 644 648
    • (2010) J Cataract Refract Surg , vol.36 , pp. 644-648
    • Hoffer, K.J.1    Shammas, H.J.2    Savini, G.3
  • 27
    • 78751541997 scopus 로고    scopus 로고
    • Comparison of anterior segment measurements with rotating Scheimpflug photography and partial coherence reflectometry
    • J. Huang, K. Pesudovs, D. Wen, S. Chen, T. Wright, X. Wang, Y. Li, and Q. Wang Comparison of anterior segment measurements with rotating Scheimpflug photography and partial coherence reflectometry J Cataract Refract Surg 37 2011 341 348
    • (2011) J Cataract Refract Surg , vol.37 , pp. 341-348
    • Huang, J.1    Pesudovs, K.2    Wen, D.3    Chen, S.4    Wright, T.5    Wang, X.6    Li, Y.7    Wang, Q.8
  • 28
    • 64449088425 scopus 로고    scopus 로고
    • Accuracy of corneal astigmatism estimation by neglecting the posterior corneal surface measurement
    • J.-D. Ho, C.-Y. Tsai, and W. Liou S- Accuracy of corneal astigmatism estimation by neglecting the posterior corneal surface measurement Am J Ophthalmol 147 2009 788 795
    • (2009) Am J Ophthalmol , vol.147 , pp. 788-795
    • Ho, J.-D.1    Tsai, C.-Y.2    Liou - S, W.3
  • 29
    • 67649360554 scopus 로고    scopus 로고
    • Agreement between Pentacam and videokeratography in corneal power assessment
    • G. Savini, P. Barboni, M. Carbonelli, and K.J. Hoffer Agreement between Pentacam and videokeratography in corneal power assessment J Refract Surg 25 2009 534 538
    • (2009) J Refract Surg , vol.25 , pp. 534-538
    • Savini, G.1    Barboni, P.2    Carbonelli, M.3    Hoffer, K.J.4
  • 30
    • 58949101631 scopus 로고    scopus 로고
    • Scheimpflug photography keratometry readings for routine intraocular lens power calculation
    • H.J. Shammas, K.J. Hoffer, and M.C. Shammas Scheimpflug photography keratometry readings for routine intraocular lens power calculation J Cataract Refract Surg 35 2009 330 334
    • (2009) J Cataract Refract Surg , vol.35 , pp. 330-334
    • Shammas, H.J.1    Hoffer, K.J.2    Shammas, M.C.3
  • 31
    • 77953660052 scopus 로고    scopus 로고
    • Scheimpflug keratometry versus conventional automated keratometry in routine cataract surgery
    • erratum 2011; 37:980
    • R.J. Symes, M.J. Say, and P.G. Ursell Scheimpflug keratometry versus conventional automated keratometry in routine cataract surgery J Cataract Refract Surg 36 2010 1107 1114 erratum 2011; 37:980
    • (2010) J Cataract Refract Surg , vol.36 , pp. 1107-1114
    • Symes, R.J.1    Say, M.J.2    Ursell, P.G.3
  • 32
    • 80051564231 scopus 로고    scopus 로고
    • Toric intraocular lens outcome using the manufacturer's prediction of corneal plane equivalent intraocular lens cylinder power
    • M. Goggin, S. Moore, and A. Esterman Toric intraocular lens outcome using the manufacturer's prediction of corneal plane equivalent intraocular lens cylinder power Arch Ophthalmol 129 2011 1004 1008
    • (2011) Arch Ophthalmol , vol.129 , pp. 1004-1008
    • Goggin, M.1    Moore, S.2    Esterman, A.3
  • 33
    • 0031680250 scopus 로고    scopus 로고
    • Comparison of three computerized videokeratoscopy systems with keratometry
    • R.C.M.R. Moura, B.L. Bowyer, S.X. Stevens, and J.J. Rowsey Comparison of three computerized videokeratoscopy systems with keratometry Cornea 17 1998 522 528 (Pubitemid 28420684)
    • (1998) Cornea , vol.17 , Issue.5 , pp. 522-528
    • Moura, R.C.M.R.1    Bowyer, B.L.2    Stevens, S.X.3    Rowsey, J.J.4
  • 34
    • 67650624137 scopus 로고    scopus 로고
    • Repeatability of Oculus pentacam metrics derived from corneal topography
    • M.A. Miranda, H. Radhakrishnan, and C. O'Donnell Repeatability of Oculus pentacam metrics derived from corneal topography Cornea 28 2009 657 666
    • (2009) Cornea , vol.28 , pp. 657-666
    • Miranda, M.A.1    Radhakrishnan, H.2    O'Donnell, C.3
  • 35
    • 0022655651 scopus 로고
    • On the calculation of power from curvature of the cornea
    • T. Olsen On the calculation of power from curvature of the cornea Br J Ophthalmol 70 1986 152 154 Available at: http://www.ncbi.nlm.nih.gov/pmc/ articles/PMC1040942/pdf/brjopthal00624-0073.pdf Accessed June 18, 2012 (Pubitemid 16128001)
    • (1986) British Journal of Ophthalmology , vol.70 , Issue.2 , pp. 152-154
    • Olsen, T.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.