메뉴 건너뛰기




Volumn 94, Issue 1, 2010, Pages 106-110

Evaluation of the Lenstar LS 900 non-contact biometer

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; ANTERIOR EYE CHAMBER DEPTH; ANTERIOR EYE SEGMENT; ARTICLE; BIOMETER; BIOMETRY; CONTROLLED STUDY; CORNEA; CORNEA THICKNESS; EYE AXIS LENGTH; FEMALE; HUMAN; HUMAN EXPERIMENT; INTERMETHOD COMPARISON; KERATOMETRY; LENS; LENS IMPLANT; LENS POWER; MALE; MEASUREMENT; NORMAL HUMAN; OPTICAL COHERENCE TOMOGRAPHY; PRIORITY JOURNAL; REPRODUCIBILITY;

EID: 74549169139     PISSN: 00071161     EISSN: 14682079     Source Type: Journal    
DOI: 10.1136/bjo.2009.161729     Document Type: Article
Times cited : (162)

References (15)
  • 2
    • 0034899732 scopus 로고    scopus 로고
    • Real-time optical coherence tomography of the anterior segment at 1310 nm
    • Radhakrishnan S, Rollins AM, Roth JE, et al. Real-time optical coherence tomography of the anterior segment at 1310 nm. Arch Ophthalmol 2001;119:1179-85.
    • (2001) Arch Ophthalmol , vol.119 , pp. 1179-1185
    • Radhakrishnan, S.1    Rollins, A.M.2    Roth, J.E.3
  • 3
    • 4444312568 scopus 로고    scopus 로고
    • Static and dynamic analysis of the anterior segment with optical coherence tomography
    • Baikoff G, Lutun E, Ferraz C, et al. Static and dynamic analysis of the anterior segment with optical coherence tomography. J Cataract Refract Surg 2004;30:1843-50.
    • (2004) J Cataract Refract Surg , vol.30 , pp. 1843-1850
    • Baikoff, G.1    Lutun, E.2    Ferraz, C.3
  • 4
    • 34547226688 scopus 로고    scopus 로고
    • Comparison of anterior chamber depth measurements using the IOLMaster, scanning peripheral anterior chamber depth analyser, and anterior segment optical coherence tomography
    • Lavanya R, Teo L, Friedman DS, et al. Comparison of anterior chamber depth measurements using the IOLMaster, scanning peripheral anterior chamber depth analyser, and anterior segment optical coherence tomography. Br J Ophthalmol 2007;91:1023-6.
    • (2007) Br J Ophthalmol , vol.91 , pp. 1023-1026
    • Lavanya, R.1    Teo, L.2    Friedman, D.S.3
  • 5
    • 0032190258 scopus 로고    scopus 로고
    • Partial coherence interferometry: A novel approach to biometry in cataract surgery
    • Drexler W, Findl O, Menapace R, et al. Partial coherence interferometry: a novel approach to biometry in cataract surgery. Am J Ophthalmol 1998;126:524-34.
    • (1998) Am J Ophthalmol , vol.126 , pp. 524-534
    • Drexler, W.1    Findl, O.2    Menapace, R.3
  • 7
    • 0031928879 scopus 로고    scopus 로고
    • High precision biometry of pseudophakic eyes using partial coherence interferometry
    • Findl O, Drexler W, Menapace R, et al. High precision biometry of pseudophakic eyes using partial coherence interferometry. J Cataract Refract Surg 1998;24:1087-93.
    • (1998) J Cataract Refract Surg , vol.24 , pp. 1087-1093
    • Findl, O.1    Drexler, W.2    Menapace, R.3
  • 8
    • 0035205647 scopus 로고    scopus 로고
    • Reproducibility of optical biometry using partial coherence interferometry: Intraobserver and interobserver reliability
    • Vogel A, Dick HB, Krummenauer F. Reproducibility of optical biometry using partial coherence interferometry: intraobserver and interobserver reliability. J Cataract Refract Surg 2001;27:1961-8.
    • (2001) J Cataract Refract Surg , vol.27 , pp. 1961-1968
    • Vogel, A.1    Dick, H.B.2    Krummenauer, F.3
  • 9
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986;1:307-10.
    • (1986) Lancet , vol.1 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 10
    • 34250648821 scopus 로고    scopus 로고
    • Central corneal thickness measurements using Orbscan II, Visante, ultrasound, and Pentacam pachymetry after laser in situ keratomileusis for myopia
    • Ho T, Cheng AC, Rao SK, et al. Central corneal thickness measurements using Orbscan II, Visante, ultrasound, and Pentacam pachymetry after laser in situ keratomileusis for myopia. J Cataract Refract Surg 2007;33:1177-82.
    • (2007) J Cataract Refract Surg , vol.33 , pp. 1177-1182
    • Ho, T.1    Cheng, A.C.2    Rao, S.K.3
  • 11
    • 34748896756 scopus 로고    scopus 로고
    • Agreement among 3 methods to measure corneal thickness: Ultrasound pachymetry, Orbscan II, and Visante anterior segment optical coherence tomography
    • Li EY, Mohamed S, Leung CK, et al. Agreement among 3 methods to measure corneal thickness: ultrasound pachymetry, Orbscan II, and Visante anterior segment optical coherence tomography. Ophthalmology 2007;114:1842-7.
    • (2007) Ophthalmology , vol.114 , pp. 1842-1847
    • Li, E.Y.1    Mohamed, S.2    Leung, C.K.3
  • 12
    • 42649140555 scopus 로고    scopus 로고
    • Comparative study of central corneal thickness measurement with slit-lamp optical coherence tomography and visante optical coherence tomography
    • Li H, Leung CK, Wong L, et al. Comparative study of central corneal thickness measurement with slit-lamp optical coherence tomography and visante optical coherence tomography. Ophthalmology 2008;115:796-801.
    • (2008) Ophthalmology , vol.115 , pp. 796-801
    • Li, H.1    Leung, C.K.2    Wong, L.3
  • 13
    • 27144445263 scopus 로고    scopus 로고
    • Measurement of the internal diameter and depth of the anterior chamber: IOLMaster versus anterior chamber optical coherence tomographer
    • Baikoff G, Jitsuo Jodai H, Bourgeon G. Measurement of the internal diameter and depth of the anterior chamber: IOLMaster versus anterior chamber optical coherence tomographer. J Cataract Refract Surg 2005;31:1722-8.
    • (2005) J Cataract Refract Surg , vol.31 , pp. 1722-1728
    • Baikoff, G.1    Jitsuo Jodai, H.2    Bourgeon, G.3
  • 14
    • 0034747904 scopus 로고    scopus 로고
    • The repeatability and accuracy of axial length and anterior chamber depth measurements from the IOLMaster
    • Lam AK, Chan R, Pang PC. The repeatability and accuracy of axial length and anterior chamber depth measurements from the IOLMaster. Ophthalmic Physiol Opt 2001;21:477-83.
    • (2001) Ophthalmic Physiol Opt , vol.21 , pp. 477-483
    • Lam, A.K.1    Chan, R.2    Pang, P.C.3
  • 15
    • 34047238184 scopus 로고    scopus 로고
    • Axial length measurement using partial coherence interferometry in myopic children: Repeatability of the measurement and comparison with refractive components
    • Kimura S, Hasebe S, Miyata M, et al. Axial length measurement using partial coherence interferometry in myopic children: repeatability of the measurement and comparison with refractive components. Jpn J Ophthalmol 2007;51:105-10.
    • (2007) Jpn J Ophthalmol , vol.51 , pp. 105-110
    • Kimura, S.1    Hasebe, S.2    Miyata, M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.