메뉴 건너뛰기




Volumn 49, Issue 4, 2012, Pages 383-406

Optical biosensors for food quality and safety assurance-A review

Author keywords

Fiber optic biosensors; Heavy metalions; Pathogen detection; Pesticide and drug residues; SPR

Indexed keywords

ANALYTES; CONVENTIONAL METHODS; DRUG RESIDUE; FIBER OPTIC BIOSENSOR; FOOD CONTAMINATION; FOOD QUALITY AND SAFETIES; FOOD SAMPLES; FOOD SPOILAGE; FOOD-BORNE ILLNESS; GROWTH MEDIUM; HIGH SPECIFICITY; OPTICAL BIO-SENSORS; PATHOGEN DETECTION; QUICK RESPONSE; SCIENTIFIC DISCIPLINE; SPR; TOXIC SUBSTANCES;

EID: 84863988765     PISSN: 00221155     EISSN: 09758402     Source Type: Journal    
DOI: 10.1007/s13197-011-0437-6     Document Type: Review
Times cited : (231)

References (131)
  • 1
    • 36049010928 scopus 로고    scopus 로고
    • An optical biosensor based on immobilization of laccase and MBTH in stacked films for the detection of catechol
    • Abdullah AJ, Heng MLY, Karuppiah N, Sidek H (2007) An optical biosensor based on immobilization of laccase and MBTH in stacked films for the detection of catechol. Sensors 7:2238-2250
    • (2007) Sensors , vol.7 , pp. 2238-2250
    • Abdullah, A.J.1    Heng, M.L.Y.2    Karuppiah, N.3    Sidek, H.4
  • 2
    • 84863986108 scopus 로고    scopus 로고
    • Basic principles of optical biosensors in food engineering
    • Mutlu M (ed) Biosensors in food processing, safety and quality control
    • Akdǒan E, Mutlu M (2011) Basic principles of optical biosensors in food engineering. In: Mutlu M (ed) Biosensors in food processing, safety and quality control. CRC, Boca Raton, pp 53-70
    • (2011) CRC, Boca Raton , pp. 53-70
    • Akdoǧan, E.1    Mutlu, M.2
  • 3
    • 0037403839 scopus 로고    scopus 로고
    • Market analysis of biosensors for food safety
    • Alocilja EC, Radke SM (2003) Market analysis of biosensors for food safety. Biosens Bioelectron 18:841-84
    • (2003) Biosens Bioelectron , vol.18 , pp. 841-84
    • Alocilja, E.C.1    Radke, S.M.2
  • 4
    • 49549090664 scopus 로고    scopus 로고
    • A novel microbial biosensor based on Circinella sp. modified carbon paste electrode and its voltammetric application
    • Alpat S, Alpat KS, çadirci BH, Yaşa I, Telefoncu A (2008) A novel microbial biosensor based on Circinella sp. modified carbon paste electrode and its voltammetric application. Sens Actuators B: Chem 134:175-181
    • (2008) Sens Actuators B: Chem , vol.134 , pp. 175-181
    • Alpat, S.1    Alpat, K.S.2    Çadirci, B.H.3    Yaşa, I.4    Telefoncu, A.5
  • 5
    • 36049047301 scopus 로고    scopus 로고
    • A urea biosensor from stacked sol-gel films with immobilized nile blue chromoionophore and urease enzyme
    • Alquasaimeh MS, Heng LY, Ahmad M (2007) A urea biosensor from stacked sol-gel films with immobilized nile blue chromoionophore and urease enzyme. Sensors 7(10):2251-2262
    • (2007) Sensors , vol.7 , Issue.10 , pp. 2251-2262
    • Alquasaimeh, M.S.1    Heng, L.Y.2    Ahmad, M.3
  • 6
    • 0037146794 scopus 로고    scopus 로고
    • Improved fluoroimmunoassays using the dye Alexa Fluor 647 with the RAPTOR, a fiber optic biosensor
    • DOI 10.1016/S0022-1759(02)00327-7, PII S0022175902003277
    • Anderson GP, Nerurkar NL (2002) Improved fluoroimmunoassays using the dye Alexa flour 647 with the RAPTOR, a fiber optic biosensor. J Immun Mthds 271:17-24 (Pubitemid 35346363)
    • (2002) Journal of Immunological Methods , vol.271 , Issue.1-2 , pp. 17-24
    • Anderson, G.P.1    Nerurkar, N.L.2
  • 7
    • 0036134827 scopus 로고    scopus 로고
    • A portable fiber-optic pesticide biosensor based on immobilized cholinesterase and sol-gel entrapped bromcresol purple for in-field use
    • DOI 10.1016/S0956-5663(01)00261-5, PII S0956566301002615
    • Andreou VG, Clonis YD (2002) A portable fiber-optic pesticide biosensor based on immobilized cholinesterase and sol-gel entrapped bromcresol purple for in-field use. Biosens Bioelectron 17(1-2):61-69 (Pubitemid 34003611)
    • (2002) Biosensors and Bioelectronics , vol.17 , Issue.1-2 , pp. 61-69
    • Andreou, V.G.1    Clonis, Y.D.2
  • 9
    • 33646540694 scopus 로고    scopus 로고
    • Recent developments in bio-molecular electronics techniques for food pathogens
    • DOI 10.1016/j.aca.2006.03.078, PII S0003267006006568, Molecular Electronics and Analytical Chemistry
    • Arora K, Chand S, Malhotra BD (2006) Recent developments in biomolecular electronics techniques for food pathogens. Anal Chim Acta 568:259-274 (Pubitemid 43729731)
    • (2006) Analytica Chimica Acta , vol.568 , Issue.1-2 , pp. 259-274
    • Arora, K.1    Chand, S.2    Malhotra, B.D.3
  • 10
    • 84986806151 scopus 로고
    • The application of ATP bioluminescence for the assessment of milk quality and factory hygiene
    • Bautista DA, Mcintire L, Laeye L, Griffiths MW (1992) The application of ATP bioluminescence for the assessment of milk quality and factory hygiene. J Rapid Meth Automat Microbiol 1(3):179-193
    • (1992) J Rapid Meth Automat Microbiol , vol.1 , Issue.3 , pp. 179-193
    • Bautista, D.A.1    Mcintire, L.2    Laeye, L.3    Griffiths, M.W.4
  • 11
    • 0028887357 scopus 로고
    • Rapid assessment of the microbiological quality of poultry carcasses using ATP bioluminescence
    • Bautista DA, Vaillancourt JP, Clarke RA, Renwick S, Griffiths MW (1995) Rapid assessment of the microbiological quality of poultry carcasses using ATP bioluminescence. J Food Protect 58(5):551-554
    • (1995) J Food Protect , vol.58 , Issue.5 , pp. 551-554
    • Bautista, D.A.1    Vaillancourt, J.P.2    Clarke, R.A.3    Renwick, S.4    Griffiths, M.W.5
  • 12
    • 0038604176 scopus 로고    scopus 로고
    • Microbial whole-cell sensing systems of environmental pollutants
    • DOI 10.1016/S1369-5274(03)00059-6
    • Belkin S (2003) Microbial whole-cell sensing systems of environmental pollutants. Curr Opin Microbiol 6(3):206-212 (Pubitemid 36841662)
    • (2003) Current Opinion in Microbiology , vol.6 , Issue.3 , pp. 206-212
    • Belkin, S.1
  • 13
    • 33646171528 scopus 로고    scopus 로고
    • Towards a disposable in vivo miniature implantable fluorescence detector
    • 60830N (2006); doi:10.1117/12.646268
    • Bellis S, Jackson JC, Mathewson A (2006) Towards a disposable in vivo miniature implantable fluorescence detector, Proc. SPIE 6083, 60830N (2006); doi:10.1117/12.646268.
    • (2006) Proc. SPIE 6083
    • Bellis, S.1    Jackson, J.C.2    Mathewson, A.3
  • 14
    • 39049099901 scopus 로고    scopus 로고
    • Biosensors and bio-based methods for the separation and detection of foodborne pathogens
    • Bhunia AK (2008) Biosensors and bio-based methods for the separation and detection of foodborne pathogens. Adv Food Nutr Res 54:1-44
    • (2008) Adv Food Nutr Res , vol.54 , pp. 1-44
    • Bhunia, A.K.1
  • 15
    • 80051997587 scopus 로고    scopus 로고
    • (sighted on 27 February 2011)
    • Bhunia AK (2011) Rapid Pathogen Screening Tools For Food Safety. Food Tech 65(2) URL: http://www.ift.org/food-technology/pastissues/2011/february/ features/rapid-pathogen-screening-tools-forfood-safety.aspx (sighted on 27 February 2011)
    • (2011) Rapid Pathogen Screening Tools for Food Safety. Food Tech , vol.65 , Issue.2
    • Bhunia, A.K.1
  • 17
    • 0006070426 scopus 로고
    • Fibre optic biosensors with immobilized bioluminescence enzymes
    • Blum LJ, Gautier SM, Coulet PR (1991) Fibre optic biosensors with immobilized bioluminescence enzymes. J Mater Sci Mater Med 2 (4):202-204
    • (1991) J Mater Sci Mater Med , vol.2 , Issue.4 , pp. 202-204
    • Blum, L.J.1    Gautier, S.M.2    Coulet, P.R.3
  • 21
    • 84863985022 scopus 로고    scopus 로고
    • Centre for Bioelctronics and Biosensors, (Sighted on 6 June 2011)
    • Centre for Bioelctronics and Biosensors (2011) Home page of laboratory. URL:http://www.biodesign.asu.edu/research/researchcenters/bioelectronics-and- biosensors (Sighted on 6 June 2011)
    • (2011) Home page of laboratory
  • 22
    • 0000172172 scopus 로고    scopus 로고
    • Molecular assembly of multilayer enzyme: Toward the development of a chemiluminescence-based fiber optic biosensor
    • DOI 10.1016/S0928-4931(96)00154-3, PII S0928493196001543
    • Chen Z, Kaplan DL, Gao H, Kumar J, Marx KA, Tripathy SK (1996) Molecular assembly of multilayer enzyme: toward the development of chemiluminescence- based fiber optic biosensor. Mater Sci Eng 4:155-159 (Pubitemid 126384046)
    • (1996) Materials Science and Engineering C , vol.4 , Issue.3 , pp. 155-159
    • Chen, Z.1    Kaplan, D.L.2    Gao, H.3    Kumar, J.4    Marx, K.A.5    Tripathy, S.K.6
  • 23
    • 0036633640 scopus 로고    scopus 로고
    • Optical biosensors in drug discovery
    • Cooper MA (2002) Optical biosensors in drug discovery. Nat Rev Drug Discov 1:515-528 (Pubitemid 37368826)
    • (2002) Nature Reviews Drug Discovery , vol.1 , Issue.7 , pp. 515-528
    • Cooper, M.A.1
  • 24
    • 56049098133 scopus 로고    scopus 로고
    • Tapered optical fibers biosensor for the detection of anti-gliadin antibodies
    • Corres JM, Matias IR, Bravo J, Arregui FJ (2008) Tapered optical fibers biosensor for the detection of anti-gliadin antibodies. Sens Actuators B: Chem 135(1):166-171
    • (2008) Sens Actuators B: Chem , vol.135 , Issue.1 , pp. 166-171
    • Corres, J.M.1    Matias, I.R.2    Bravo, J.3    Arregui, F.J.4
  • 25
    • 60449093642 scopus 로고    scopus 로고
    • Modeling and measurement of a whole-cell bioluminescent biosensor based on a single photon avalanche diode
    • Daniela R, Almoga R, Rona A, Belkinb S, Diamand YS (2008)Modeling and measurement of a whole-cell bioluminescent biosensor based on a single photon avalanche diode. Biosens Bioelectron 24:888-893
    • (2008) Biosens Bioelectron , vol.24 , pp. 888-893
    • Daniela, R.1    Almoga, R.2    Rona, A.3    Belkinb, S.4    Diamand, Y.S.5
  • 27
    • 0036010263 scopus 로고    scopus 로고
    • Detection of Escherichia coli O157:h7 in 10- and 25-gram ground beef samples with an evanescent-wave biosensor with silica and polystyrene waveguides
    • Demarco DR, Lim DV (2002) Detection of escherichia coli O157:H7 in 10 and 25-gram ground beef samples with an evanescent-wave biosensor with silica and polystyrene waveguides. J Food Protect 65:596-602 (Pubitemid 34294203)
    • (2002) Journal of Food Protection , vol.65 , Issue.4 , pp. 596-602
    • DeMarco, D.R.1    Lim, D.V.2
  • 28
    • 0033166564 scopus 로고    scopus 로고
    • Rapid detection of Escherichia coli O157:H7 in ground beef using a fiber-optic biosensor
    • Demarco DR, Saaski W, Mccrae DA, Lim D (1999) Rapid detection of Escherichia coli O157:H7 in ground beef using a fiber-optic biosensor. J Food Protect 62(7):711-716 (Pubitemid 29324215)
    • (1999) Journal of Food Protection , vol.62 , Issue.7 , pp. 711-716
    • DeMarco, D.R.1    Saaski, E.W.2    McCrae, D.A.3    Lim, D.V.4
  • 29
    • 17744375618 scopus 로고    scopus 로고
    • Subpicomolar sensing of delta-opioid receptor ligands by molecular-imprinted polymers using plasmon-waveguide resonance spectroscopy
    • DOI 10.1021/ac048476e
    • Devanathan S, Salamon Z, Nagar A, Narang S, Schleich D, Darman P, Hruby V, Tollin G (2005) Subpicomolar sensing of delta-opioid receptor ligands by molecular-imprinted polymers using plasmon-waveguide resonance spectroscopy. Anal Chem 77 (8):2569-2574 (Pubitemid 40575715)
    • (2005) Analytical Chemistry , vol.77 , Issue.8 , pp. 2569-2574
    • Devanathan, S.1    Salamon, Z.2    Nagar, A.3    Narang, S.4    Schleich, D.5    Darman, P.6    Hruby, V.7    Tollin, G.8
  • 30
    • 0034910570 scopus 로고    scopus 로고
    • Microbial biosensors
    • DOI 10.1016/S0956-5663(01)00125-7, PII S0956566301001257
    • D'Souza SF (2001) Microbial biosensors. Biosens Bioelectron 16 (6):337-353 (Pubitemid 32728156)
    • (2001) Biosensors and Bioelectronics , vol.16 , Issue.6 , pp. 337-353
    • D'Souza, S.F.1
  • 31
    • 34250886536 scopus 로고    scopus 로고
    • Development of an immunosensor based on surface plasmon resonance for enumeration of Escherichia coli in water samples
    • DOI 10.1016/j.foodres.2007.01.011, PII S0963996907000257
    • Dudak FC, Boyac IH (2007) Development of an immunosensor based on surface plasmon resonance for enumeration of Escherichia coli in water samples. Food Res Int 40(7):803-807 (Pubitemid 46990895)
    • (2007) Food Research International , vol.40 , Issue.7 , pp. 803-807
    • Dudak, F.C.1    Boyaci, I.H.2
  • 34
    • 36048969417 scopus 로고    scopus 로고
    • Non-invasive optical biosensor for probing cell signaling
    • Fang Y (2007) Non-invasive optical biosensor for probing cell signaling. Sensors 7:2316-2329
    • (2007) Sensors , vol.7 , pp. 2316-2329
    • Fang, Y.1
  • 36
    • 19944432788 scopus 로고    scopus 로고
    • Detection of chloramphenicol and chloramphenicol glucuronide residues in poultry muscle, honey, prawn and milk using a surface plasmon resonance biosensor and Qflex® kit chloramphenicol
    • DOI 10.1016/j.aca.2004.11.042, PII S0003267004015703
    • Ferguson J, Baxter A, Young P, Kennedy G, Elliott C, Weigel S, Gatermann R, Ashwin H, Stead S, Sharman M (2005) Detection of chloramphenicol and chloramphenicol glucuronide residues in poultry muscle, honey, prawn and milk using a surface plasmon resonance biosensor and Qflex® kit chloramphenicol. Anal Chim Act 529(1-2):109-113 (Pubitemid 40164301)
    • (2005) Analytica Chimica Acta , vol.529 , Issue.1-2 SPEC. ISS. , pp. 109-113
    • Ferguson, J.1    Baxter, A.2    Young, P.3    Kennedy, G.4    Elliott, C.5    Weigel, S.6    Gatermann, R.7    Ashwin, H.8    Stead, S.9    Sharman, M.10
  • 37
    • 33750519668 scopus 로고    scopus 로고
    • Comparison of a rapid ATP bioluminescence assay and standard plate count methods for assessing microbial contamination of consumers' refrigerators
    • Fur-Chi C, Sandria GL (2006) Comparison of a rapid ATP bioluminescence assay and standard plate count methods for assessing microbial contamination of consumers' refrigerators. J Food Prot 69(10):2534-2538
    • (2006) J Food Prot , vol.69 , Issue.10 , pp. 2534-2538
    • Fur-Chi, C.1    Sandria, G.L.2
  • 38
    • 33750743766 scopus 로고    scopus 로고
    • Surface plasmon resonance for detection of genetically modified organisms in the food supply
    • Gambari R, Feriotto G (2006) Surface plasmon resonance for detection of genetically modified organisms in the food supply.J AOAC Intl 89(3):893-897 (Pubitemid 44933423)
    • (2006) Journal of AOAC International , vol.89 , Issue.3 , pp. 893-897
    • Gambari, R.1    Feriotto, G.2
  • 39
    • 33846195585 scopus 로고    scopus 로고
    • Fiber optic biosensor employing Alexa- Fluor conjugated antibody for detection of Escheria coli O157:H7 from ground beef in four hours
    • Geng T, Uknalis J, Tu SI, Bhunia AK (2006) Fiber optic biosensor employing Alexa- Fluor conjugated antibody for detection of Escheria coli O157:H7 from ground beef in four hours. Sensors 6:796-807
    • (2006) Sensors , vol.6 , pp. 796-807
    • Geng, T.1    Uknalis, J.2    Tu, S.I.3    Bhunia, A.K.4
  • 41
    • 0036716875 scopus 로고    scopus 로고
    • A comparison of imaging methods for use in an array biosensor
    • DOI 10.1016/S0956-5663(02)00060-X, PII S095656630200060X
    • Golden JP, Ligler FS (2002) A comparison of imaging methods for use in an array biosensor. Biosen Bioel 17:719-725 (Pubitemid 35015109)
    • (2002) Biosensors and Bioelectronics , vol.17 , Issue.9 , pp. 719-725
    • Golden, J.P.1    Ligler, F.S.2
  • 42
    • 0942299019 scopus 로고    scopus 로고
    • Novel type of avalanche photodetector with Geiger mode operation
    • Golovin V, Saveliev V (2004) Novel type of avalanche photodetector with Geiger mode operation. Nucl Inst Meth Phys Res Sect 518:560-564
    • (2004) Nucl Inst Meth Phys Res Sect , vol.518 , pp. 560-564
    • Golovin, V.1    Saveliev, V.2
  • 43
    • 41149112868 scopus 로고    scopus 로고
    • Dual-mode surface-plasmon-resonance sensors using angular interrogation
    • DOI 10.1364/OL.33.000512
    • Guo J, Keathley P, Hastings J (2008) Dual-mode surface-plasmonresonance sensors using angular interrogation. Opt Lett 33:512-514 (Pubitemid 351431557)
    • (2008) Optics Letters , vol.33 , Issue.5 , pp. 512-514
    • Guo, J.1    Keathley, P.D.2    Hastings, J.T.3
  • 44
    • 6944235710 scopus 로고    scopus 로고
    • Detection of bioavailable heavy metals in EILATox-Oregon samples using whole-cell luminescent bacterial sensors in suspension or immobilized onto fibre-optic tips
    • DOI 10.1002/jat.1020
    • Hakkila K, Green T, Leskinen P, Ivask A, Marks R, Virta M (2004)Detection of bioavailable heavy metals in EILATox-oregon samples using whole-cell luminescent bacterial sensors in suspension or immobilized onto fibre-optic tips. J Appl Toxicol 24(5):333-342 (Pubitemid 39409914)
    • (2004) Journal of Applied Toxicology , vol.24 , Issue.5 , pp. 333-342
    • Hakkila, K.1    Green, T.2    Leskinen, P.3    Ivask, A.4    Marks, R.5    Virta, M.6
  • 45
    • 33750701170 scopus 로고    scopus 로고
    • Biosensor screening for veterinary drug residues in foodstuffs
    • Haughey SA, Baxter GA (2006) Biosensor screening for veterinary drug residues in foodstuffs. J AOAC Int 89(3):862-867 (Pubitemid 44933419)
    • (2006) Journal of AOAC International , vol.89 , Issue.3 , pp. 862-867
    • Haughey, S.A.1    Baxter, G.A.2
  • 46
    • 85099487680 scopus 로고    scopus 로고
    • Optical sensors: Basics and applications
    • Wenheim
    • Haus J (2009) Optical sensors: basics and applications. Wiley-VCH, Wenheim
    • (2009) Wiley-VCH
    • Haus, J.1
  • 47
    • 85005658286 scopus 로고
    • Rapid detection of antibiotics in raw milk by ATP bioluminescence
    • Hawronskyj J-M, Adams MR, Kyriakides AL (1993) Rapid detection of antibiotics in raw milk by ATP bioluminescence. Intl J Dairy Technol 46(1):31-33
    • (1993) Intl J Dairy Technol , vol.46 , Issue.1 , pp. 31-33
    • Hawronskyj, J.-M.1    Adams, M.R.2    Kyriakides, A.L.3
  • 48
    • 33244456359 scopus 로고    scopus 로고
    • Phase-sensitive surface plasmon resonance biosensor using the photoelastic modulation technique
    • DOI 10.1016/j.snb.2005.04.007, PII S0925400505004284
    • Ho HP, Law WC, Wu SY, Liu XH, Wong SP, Lin C, Kong SK (2006)Phase-sensitive surface plasmon resonance biosensor using the photoelastic modulation technique. Sens Actuators B: Chem 114 (1):80-84 (Pubitemid 43276166)
    • (2006) Sensors and Actuators, B: Chemical , vol.114 , Issue.1 , pp. 80-84
    • Ho, H.P.1    Law, W.C.2    Wu, S.Y.3    Liu, X.H.4    Wong, S.P.5    Lin, C.6    Kong, S.K.7
  • 50
    • 63849184210 scopus 로고    scopus 로고
    • Toxin detection by surface plasmon resonance
    • Hodnik V, Anderluh G (2009) Toxin detection by surface plasmon resonance. Sensors 9:1339-1354
    • (2009) Sensors , vol.9 , pp. 1339-1354
    • Hodnik, V.1    Anderluh, G.2
  • 51
    • 0344177897 scopus 로고    scopus 로고
    • Present and future of surface plasmon resonance biosensors
    • DOI 10.1007/s00216-003-2101-0
    • Homola J (2003) Present and future of surface plasmon resonance biosensors. Anal Bioanal Chem 377:528-539 (Pubitemid 40882962)
    • (2003) Analytical and Bioanalytical Chemistry , vol.377 , Issue.3 , pp. 528-539
    • Homola, J.1
  • 53
    • 0034730909 scopus 로고    scopus 로고
    • Novel bioluminescent assay of pyruvate phosphate dikinase using firefly luciferase-luciferin reaction and its application to bioluminescent enzyme immunoassay
    • DOI 10.1016/S0003-2670(00)01054-0, PII S0003267000010540
    • Ito K, Nishimura K, Murakamib S, Arakawa H, Maedaa M (2000)Novel bioluminescent assay of pyruvate phosphate dikinase using firefly luciferase-luciferin reaction and its application to bioluminescent enzyme immunoassay. Anal Chim Act 421:113-120 (Pubitemid 30654919)
    • (2000) Analytica Chimica Acta , vol.421 , Issue.2 , pp. 113-120
    • Ito, K.1    Nishimura, K.2    Murakami, S.3    Arakawa, H.4    Maeda, M.5
  • 55
    • 4043166896 scopus 로고    scopus 로고
    • Atomic force spectroscopy-based study of antibody pesticide interactions for characterization of immunosensor surface
    • DOI 10.1016/j.bios.2004.01.012, PII S0956566304000302
    • Kaur J, Singh KV, Schmid AH, Varshney GC, Suri CR, Raje M (2004)Atomic force spectroscopy-based study of antibody pesticide interactions for characterization of immunosensor surface. Biosens Bioelectron 20(2):284-293 (Pubitemid 39077632)
    • (2004) Biosensors and Bioelectronics , vol.20 , Issue.2 , pp. 284-293
    • Kaur, J.1    Singh, K.V.2    Schmid, A.H.3    Varshney, G.C.4    Suri, C.R.5    Raje, M.6
  • 58
    • 33645848492 scopus 로고    scopus 로고
    • Optical microbial biosensor for detection of methyl parathion pesticide using Flavobacterium sp.whole cells adsorbed on glass fiber filters as disposable biocomponent
    • Kumar J, Jha SK, D'Souza SF (2006) Optical microbial biosensor for detection of methyl parathion pesticide using Flavobacterium sp.whole cells adsorbed on glass fiber filters as disposable biocomponent. Biosens Bioelectron 21:2100-2105
    • (2006) Biosens Bioelectron , vol.21 , pp. 2100-2105
    • Kumar, J.1    Jha, S.K.2    D'Souza, S.F.3
  • 59
    • 53049110634 scopus 로고    scopus 로고
    • Using a surface plasmon resonance biosensor for rapid detection of Salmonella Typhimurium in chicken carcass
    • Lan YB, Wang SZ, Yin YG, Hoffmann WC, Zheng XZ (2008) Using a surface plasmon resonance biosensor for rapid detection of Salmonella Typhimurium in chicken carcass. J Bionic Eng 5 (3):239.246
    • (2008) J Bionic Eng , vol.5 , Issue.3 , pp. 239-246
    • Lan, Y.B.1    Wang, S.Z.2    Yin, Y.G.3    Hoffmann, W.C.4    Zheng, X.Z.5
  • 60
    • 33846448162 scopus 로고    scopus 로고
    • Pathogen detection: A perspective of traditional methods and biosensors
    • DOI 10.1016/j.bios.2006.06.036, PII S0956566306003071
    • Lazcka O, Del Campo JF, Munoz FX (2007) Pathogen detection: a perspective of traditional methods and biosensors. Biosens Bioelectron 22:1205-1217 (Pubitemid 46138081)
    • (2007) Biosensors and Bioelectronics , vol.22 , Issue.7 , pp. 1205-1217
    • Lazcka, O.1    Campo, F.J.D.2    Munoz, F.X.3
  • 64
    • 78649731923 scopus 로고    scopus 로고
    • Direct detection of Salmonella typhimurium on fresh produce using phage-based magnetoelastic biosensors
    • Li S, Li Y, Chen H, Horikawa S, Shen W, Simonian A, Chin BA (2010) Direct detection of Salmonella typhimurium on fresh produce using phage-based magnetoelastic biosensors. Biosens Bioelectron 26:1313-1319
    • (2010) Biosens Bioelectron , vol.26 , pp. 1313-1319
    • Li, S.1    Li, Y.2    Chen, H.3    Horikawa, S.4    Shen, W.5    Simonian, A.6    Chin, B.A.7
  • 66
    • 34547762130 scopus 로고    scopus 로고
    • Development and application of side-polished fiber immunosensor based on surface plasmon resonance for the detection of Legionella pneumophila with halogens light and 850 nm-LED
    • Lin HY, Tsao YC, Tsai WH, Yang YW, Yan TR, Sheu BC (2007)Development and application of side-polished fiber immunosensor based on surface plasmon resonance for the detection of Legionella pneumophila with halogens light and 850 nm-LED. Sens Actuators B: Chem 138(2):299-305
    • (2007) Sens Actuators B: Chem , vol.138 , Issue.2 , pp. 299-305
    • Lin, H.Y.1    Tsao, Y.C.2    Tsai, W.H.3    Yang, Y.W.4    Yan, T.R.5    Sheu, B.C.6
  • 67
    • 58149374378 scopus 로고    scopus 로고
    • Quantitative measurement of binding kinetics in sandwich assay using a fluorescence detection fiber optic biosensor
    • Lin C, Chen H, Yu C, Lu P, Hsieh C, Hsieh B, Chang Y, Chou C (2009) Quantitative measurement of binding kinetics in sandwich assay using a fluorescence detection fiber optic biosensor. Anal Biochem 385:224-228
    • (2009) Anal Biochem , vol.385 , pp. 224-228
    • Lin, C.1    Chen, H.2    Yu, C.3    Lu, P.4    Hsieh, C.5    Hsieh, B.6    Chang, Y.7    Chou, C.8
  • 68
    • 84755160636 scopus 로고    scopus 로고
    • Compact quantitative optic fiber-based immunoarray biosensor for rapid detection of small analytes
    • Long F, He M, Zhu A, Song B, Sheng J, Shi H (2010) Compact quantitative optic fiber-based immunoarray biosensor for rapid detection of small analytes. Biosens Bioelectron 26 (1):16-22
    • (2010) Biosens Bioelectron , vol.26 , Issue.1 , pp. 16-22
    • Long, F.1    He, M.2    Zhu, A.3    Song, B.4    Sheng, J.5    Shi, H.6
  • 71
    • 31944433134 scopus 로고    scopus 로고
    • Determination of environmental organic pollutants with a portable optical immunosensor
    • DOI 10.1016/j.talanta.2005.09.049, PII S0039914005006624
    • Mauriz E, Calle A, Montoya A, Lechuga LM (2006) Determination of environmental organic pollutants with a portable optical immunosensor. Talanta 69(2):359-364 (Pubitemid 43190183)
    • (2006) Talanta , vol.69 , Issue.2 SPEC. ISS. , pp. 359-364
    • Mauriz, E.1    Calle, A.2    Montoya, A.3    Lechuga, L.M.4
  • 72
    • 12844273861 scopus 로고    scopus 로고
    • Multisulfonamide screening in porcine muscle using a surface plasmon resonance biosensor
    • McGrath T, Baxter A, Ferguson J, Haughey S, Bjurling P (2005) Multisulfonamide screening in porcine muscle using a surface plasmon resonance biosensor. Anal Chim Act 529(1-2):12-127
    • (2005) Anal Chim Act , vol.529 , Issue.1-2 , pp. 12-127
    • McGrath, T.1    Baxter, A.2    Ferguson, J.3    Haughey, S.4    Bjurling, P.5
  • 73
    • 0009918374 scopus 로고    scopus 로고
    • Photocatalytic degradation of aqueous tetrahydrofuran, 1,4-dioxane and their mixture with TiO2
    • Mehrvar M, Anderson WA, Young MM (2000) Photocatalytic degradation of aqueous tetrahydrofuran, 1,4-dioxane and their mixture with TiO2. Intl J Photoenergy 2:67-80
    • (2000) Intl J Photoenergy , vol.2 , pp. 67-80
    • Mehrvar, M.1    Anderson, W.A.2    Young, M.M.3
  • 75
    • 34248157715 scopus 로고    scopus 로고
    • Antibody immobilization on waveguides using a flow.through system shows improved Listeria monocytogenes detection in an automated fiber optic biosensor: RAPTOR
    • Nanduri V, Kim G, Morgan MT, Ess D, Hahm B-K, Kothapalli A, Valdez A, Geng T, Bhunia AK (2006) Antibody immobilization on waveguides using a flow.through system shows improved Listeria monocytogenes detection in an automated fiber optic biosensor: RAPTOR. Sensors 6:808-822
    • (2006) Sensors , vol.6 , pp. 808-822
    • Nanduri, V.1    Kim, G.2    Morgan, M.T.3    Ess, D.4    Hahm, B.-K.5    Kothapalli, A.6    Valdez, A.7    Geng, T.8    Bhunia, A.K.9
  • 76
  • 77
    • 84863987318 scopus 로고    scopus 로고
    • Nondestructive methods for quality evaluation of livestock products
    • doi:10.1007/s13197-011-0286-3
    • Narsaiah K, Jha SN (2011) Nondestructive methods for quality evaluation of livestock products. J Food Sci Technol.doi:10.1007/s13197-011-0286-3
    • (2011) J Food Sci Technol.
    • Narsaiah, K.1    Jha, S.N.2
  • 78
    • 0019821711 scopus 로고
    • Choice of buffer anion for the assay of adenosine 5'-triphosphate using firefly luciferase
    • Nichols WW, Curtis GDW, Johnston HH (1981) Choice of buffer anion for the assay of adenosine 5-triphosphate using firefly luciferase. Anal Biochem 114(2):396-397 (Pubitemid 12240488)
    • (1981) Analytical Biochemistry , vol.114 , Issue.2 , pp. 396-397
    • Nichols, W.W.1    Curtis, G.D.W.2    Johnston, H.H.3
  • 79
    • 42449117989 scopus 로고    scopus 로고
    • Multiresidue analysis of beta-agonists in bovine and porcine urine, feed and hair using liquid chromatography electrospray ionisation tandem mass spectrometry
    • Nielen MWF, Lasaroms JJP, Essers ML, Oosterink JE, Meijer T, Sanders MB, Zuidema T, Stolker AAM (2008) Multiresidue analysis of beta-agonists in bovine and porcine urine, feed and hair using liquid chromatography electrospray ionisation tandem mass spectrometry. Anal Bioanal Chem 391(1):1618-2652
    • (2008) Anal Bioanal Chem , vol.391 , Issue.1 , pp. 1618-2652
    • Nielen, M.W.F.1    Lasaroms, J.J.P.2    Essers, M.L.3    Oosterink, J.E.4    Meijer, T.5    Sanders, M.B.6    Zuidema, T.7    Stolker, A.A.M.8
  • 80
    • 85193646407 scopus 로고    scopus 로고
    • Ocean Optics, (sighted on 6 June 2011)Orellana G, Haigh D (2008) New trends in fiber-optic chemical and biological sensors
    • Ocean Optics (2011) www.oceanoptics.com (sighted on 6 June 2011)Orellana G, Haigh D (2008) New trends in fiber-optic chemical and biological sensors. Curr Anal Chem 4:273-295
    • (2011) Curr Anal Chem , vol.4 , pp. 273-295
  • 81
    • 33748582306 scopus 로고    scopus 로고
    • Development of a chemiluminescent immunosensor for chloramphenicol
    • DOI 10.1016/j.aca.2006.07.015, PII S0003267006015029, Pacifichem SI Immobilization and Application of Functional Proteins, Nucleic Acids and Cell at Solid Interfaces
    • Park IS, Kim N (2006) Development of a chemiluminescent immunosensor for chloramphenicol. Anal Chim Act 578(1):19-24 (Pubitemid 44373827)
    • (2006) Analytica Chimica Acta , vol.578 , Issue.1 , pp. 19-24
    • Park, I.-S.1    Kim, N.2
  • 82
    • 79955647068 scopus 로고    scopus 로고
    • SPR biosensor by using E. coli outer membrane layer with autodisplayed Z-domains
    • Park M, Jose J, Pyun J (2011) SPR biosensor by using E. coli outer membrane layer with autodisplayed Z-domains. Sens Actuat B -Chem 154:82-88
    • (2011) Sens Actuat B -Chem , vol.154 , pp. 82-88
    • Park, M.1    Jose, J.2    Pyun, J.3
  • 84
    • 67650067361 scopus 로고    scopus 로고
    • Microalgae fiber optic biosensors for herbicide monitoring using sol.gel technolog
    • Pena-Vazquez E, Maneiro E, Perez-Conde C, Moreno-Bondi MC, Costas E (2009) Microalgae fiber optic biosensors for herbicide monitoring using sol.gel technolog. Biosen Bioel 24(12):3538-3543
    • (2009) Biosen Bioel , vol.24 , Issue.12 , pp. 3538-3543
    • Pena-Vazquez, E.1    Maneiro, E.2    Perez-Conde, C.3    Moreno-Bondi, M.C.4    Costas, E.5
  • 86
    • 0038683312 scopus 로고    scopus 로고
    • Whole cell immobilised biosensors for toxicity assessment of a wastewater treatment plant treating phenolics-containing waste
    • DOI 10.1016/S0003-2670(03)00358-1
    • Philp JC, Balmand S, Hajto E, Bailey MJ, Wiles S, Whiteley AS, Lilley AK, Hajto J, Dunbar SA (2003) Whole cell immobilised biosensors for toxicity assessment of a wastewater treatment plant treating phenolics-containing waste. Anal Chim Act 487 (1):61-74 (Pubitemid 36724849)
    • (2003) Analytica Chimica Acta , vol.487 , Issue.1 , pp. 61-74
    • Philp, J.C.1    Balmand, S.2    Hajto, E.3    Bailey, M.J.4    Wiles, S.5    Whiteley, A.S.6    Lilley, A.K.7    Hajto, J.8    Dunbar, S.A.9
  • 87
    • 0032696764 scopus 로고    scopus 로고
    • Considerations for the quantitative transduction of hybridization of immobilized DNA
    • DOI 10.1016/S0003-2670(99)00609-1, PII S0003267099006091
    • Piunno PAE, Watterson P, Wust CC, Krull UJ (1999) Considerations for the quantitative transduction of hybridization of immobilized DNA. Anal Chem Act 400(1-3):73-89 (Pubitemid 29535389)
    • (1999) Analytica Chimica Acta , vol.400 , Issue.1-3 , pp. 73-89
    • Piunno, P.A.E.1    Watterson, J.2    Wust, C.C.3    Krull, U.J.4
  • 89
  • 90
    • 40749149985 scopus 로고    scopus 로고
    • Enzymatic detection of mercuric ions in ground-water from vegetable wastes by immobilizing pumpkin (Cucumis melo) urease in calcium alginate beads
    • DOI 10.1016/j.biortech.2007.08.073, PII S0960852407006724
    • Prakash O, Talat M, Hasan SH, Pandey RK (2008) Enzymatic detection of mercuric ions in ground-water from vegetable wastes by immobilizing pumpkin (Cucumis melo) urease in calcium alginate beads. Biores Technol 99(10):4524-4528 (Pubitemid 351380797)
    • (2008) Bioresource Technology , vol.99 , Issue.10 , pp. 4524-4528
    • Prakash, O.1    Talat, M.2    Hasan, S.H.3    Pandey, R.K.4
  • 91
    • 84863984755 scopus 로고    scopus 로고
    • Introduction to biophotonics. Wiley, New Jersey Rajan, Rajan S, Gupta BD (2007) Surface plasmon resonance based fiber-optic sensor for the detection of pesticide
    • Prasad PN (2003) Introduction to biophotonics. Wiley, New Jersey Rajan, Rajan S, Gupta BD (2007) Surface plasmon resonance based fiber-optic sensor for the detection of pesticide. Sens Actuators B: Chem 123(2):661-666
    • (2003) Sens Actuators B: Chem , vol.123 , Issue.2 , pp. 661-666
    • Prasad, P.N.1
  • 92
    • 33750702552 scopus 로고    scopus 로고
    • Biosensors for the analysis of food- and waterborne pathogens and their toxins
    • Rasooly A, Herold KE (2006) Biosensors for the analysis of food and water borne pathogens and their toxins. J AOAC Int 89(3):873-883 (Pubitemid 44933421)
    • (2006) Journal of AOAC International , vol.89 , Issue.3 , pp. 873-883
    • Rasooly, A.1    Herold, K.E.2
  • 93
    • 53249154746 scopus 로고    scopus 로고
    • Development of a biosensor microarray towards food screening, using imaging surface plasmon resonance
    • Raz SR, Bremer MGEG, Giesbers M, Norde W (2008) Development of a biosensor microarray towards food screening, using imaging surface plasmon resonance. Biosens Bioelectron 24(4):552-557
    • (2008) Biosens Bioelectron , vol.24 , Issue.4 , pp. 552-557
    • Raz, S.R.1    Bremer, M.G.E.G.2    Giesbers, M.3    Norde, W.4
  • 94
    • 36249009842 scopus 로고    scopus 로고
    • Veterinary drug residues in meat: Concerns and rapid methods for detection
    • DOI 10.1016/j.meatsci.2007.07.029, PII S0309174007002719, Symposium on Meat Safety: From Abattoir to Consumer
    • Reig M, Toldra F (2008) Veterinary drug residues in meat: concerns and rapid methods for detection. Meat Sci 78:60-67 (Pubitemid 350138575)
    • (2008) Meat Science , vol.78 , Issue.1-2 , pp. 60-67
    • Reig, M.1    Toldra, F.2
  • 95
    • 0024825040 scopus 로고
    • Fiber-optic biosensor for urea based on sensing of ammonia gas
    • Rhines TD, Arnold MA (1989) Fiber-optic biosensor for urea based on sensing of ammonia gas. Anal Chim Act 227(22):387-396 (Pubitemid 20067000)
    • (1989) Analytica Chimica Acta , vol.227 , Issue.2 , pp. 387-396
    • Rhines, T.D.1    Arnold, M.A.2
  • 96
    • 36148968069 scopus 로고    scopus 로고
    • A review on novel developments and applications of immunosensors in food analysis
    • DOI 10.1016/j.aca.2007.10.046, PII S0003267007017886
    • Ricci F, Volpe G, Micheli L, Palleschi G (2007) A review on novel developments and applications of immunosensors in food analysis. Anal Chim Act 605(2):111-129 (Pubitemid 350116762)
    • (2007) Analytica Chimica Acta , vol.605 , Issue.2 , pp. 111-129
    • Ricci, F.1    Volpe, G.2    Micheli, L.3    Palleschi, G.4
  • 97
    • 73249137770 scopus 로고    scopus 로고
    • Grading the commercial optical biosensor literature. Class of 2008: 'The Mighty Binders'
    • Rich RL, Myszka DG (2010) Grading the commercial optical biosensor literature. Class of 2008: 'The Mighty Binders'. J Mol Recognit 23:1-64
    • (2010) J Mol Recognit , vol.23 , pp. 1-64
    • Rich, R.L.1    Myszka, D.G.2
  • 98
    • 2442437836 scopus 로고    scopus 로고
    • Biotechnological applications of bioluminescence and chemiluminescence
    • DOI 10.1016/j.tibtech.2004.03.011, PII S016777990400085X
    • Roda A, Pasini P, Mirasoli M, Michelini E, Guardigli M (2004)Biotechnological applications of bioluminescence and chemiluminescence. Trends Biotechnol 22:295-303 (Pubitemid 38639777)
    • (2004) Trends in Biotechnology , vol.22 , Issue.6 , pp. 295-303
    • Roda, A.1    Pasini, P.2    Mirasoli, M.3    Michelini, E.4    Guardigli, M.5
  • 100
    • 79952814587 scopus 로고    scopus 로고
    • A portable bioluminescence engineered cell-based biosensor for on-site applications
    • Roda A, Cevenini L, Michelini E, Branchini BR (2011) A portable bioluminescence engineered cell-based biosensor for on-site applications. Biosens Bioelectron 26:3647-3653
    • (2011) Biosens Bioelectron , vol.26 , pp. 3647-3653
    • Roda, A.1    Cevenini, L.2    Michelini, E.3    Branchini, B.R.4
  • 103
    • 78049528432 scopus 로고    scopus 로고
    • Rapid and highly sensitive detection of Flavobacterium psychrophilum using high gradient immunomagnetic separation with flow cytometry
    • Ryumae U, Hibi K, Yoshiura Y, Ren H, Endo H (2010) Rapid and highly sensitive detection of Flavobacterium psychrophilum using high gradient immunomagnetic separation with flow cytometry. Aquaculture 309:125-130
    • (2010) Aquaculture , vol.309 , pp. 125-130
    • Ryumae, U.1    Hibi, K.2    Yoshiura, Y.3    Ren, H.4    Endo, H.5
  • 104
    • 84863985024 scopus 로고    scopus 로고
    • Handbook of biosensors and biosensor kinetics. Elsevier B.V, Amsterdam Sapsford KE, Taitt CR, Loo N, Ligler FS (2005) Biosensor detection of botulinum toxoid A and Staphylococcal enterotoxin B in food
    • Sadana A, Sadana N (2011) Handbook of biosensors and biosensor kinetics. Elsevier B.V, Amsterdam Sapsford KE, Taitt CR, Loo N, Ligler FS (2005) Biosensor detection of botulinum toxoid A and Staphylococcal enterotoxin B in food. Appl Environ Microbial 71:5590-5592
    • (2011) Appl Environ Microbial , vol.71 , pp. 5590-5592
    • Sadana, A.1    Sadana, N.2
  • 105
    • 0942299019 scopus 로고    scopus 로고
    • The recent development and study of silicon photomultiplier
    • Saveliev V (2004) The recent development and study of silicon photomultiplier. Nucl Inst Meth Phys Res Sect A 518:560-564
    • (2004) Nucl Inst Meth Phys Res Sect A , vol.518 , pp. 560-564
    • Saveliev, V.1
  • 108
    • 0028890129 scopus 로고
    • Microbial ATP bioluminescence as a means to detect contamination on artificially contaminated beef carcass tissue
    • Siragusa GR, Cutter CN (1995) Microbial ATP bioluminescence as a means to detect contamination on artificially contaminated beef carcass tissue. J Food Protect 58(7):764-769
    • (1995) J Food Protect , vol.58 , Issue.7 , pp. 764-769
    • Siragusa, G.R.1    Cutter, C.N.2
  • 109
    • 78349312063 scopus 로고    scopus 로고
    • Advances in surface plasmon resonance biosensor technology towards highthroughput, food-safety analysis
    • Situ C, Mooney MH, Elliott CT, Buijs J (2010) Advances in surface plasmon resonance biosensor technology towards highthroughput, food-safety analysis. TrAC Trends Anal Chem 29:1305-1315
    • (2010) TrAC Trends Anal Chem , vol.29 , pp. 1305-1315
    • Situ, C.1    Mooney, M.H.2    Elliott, C.T.3    Buijs, J.4
  • 110
    • 27444431903 scopus 로고    scopus 로고
    • Surface plamon resonance imaging of DNA based biosensors for potential applications in food analysis
    • DOI 10.1016/j.bios.2005.02.016, PII S095656630500059X
    • Spadavecchia J, Manera MG, Quaranta F, Siciliano P, Rella R (2005)Surface plamon resonance imaging of DNA based biosensors for potential applications in food analysis. Biosens Bioelectron 21 (6):894-900 (Pubitemid 41532273)
    • (2005) Biosensors and Bioelectronics , vol.21 , Issue.6 , pp. 894-900
    • Spadavecchia, J.1    Manera, M.G.2    Quaranta, F.3    Siciliano, P.4    Rella, R.5
  • 111
    • 0037089715 scopus 로고    scopus 로고
    • Rapid and specific detection of bacteria using bioluminescence
    • DOI 10.1016/S0003-2670(01)01495-7, PII S0003267001014957
    • Squirrel DJ, Price RL, Murphy MJ (2002) Rapid and specific detection of bacteria using bioluminescence. Anal Chim Act 457:109-114 (Pubitemid 34246415)
    • (2002) Analytica Chimica Acta , vol.457 , Issue.1 , pp. 109-114
    • Squirrell, D.J.1    Price, R.L.2    Murphy, M.J.3
  • 112
    • 0034975894 scopus 로고    scopus 로고
    • Combination of ATP-bioluminescence and PNA probes allows rapid total counts and identification of specific microorganisms in mixed populations
    • DOI 10.1016/S0167-7012(01)00256-1, PII S0167701201002561
    • Stender H, Sage A, Oliveira K, Broomer AJ, Young B, Coull J (2001)Combination of ATP-bioluminescence and PNA probes allows rapid total counts and identification of specific microorganisms in mixed populations. J Microbio Methods 46:69-75 (Pubitemid 32537785)
    • (2001) Journal of Microbiological Methods , vol.46 , Issue.1 , pp. 69-75
    • Stender, H.1    Sage, A.2    Oliveira, K.3    Broomer, A.J.4    Young, B.5    Coull, J.6
  • 113
    • 33244495054 scopus 로고    scopus 로고
    • Mono and dithiol surfaces on surface plasmon resonance biosensors for detection of Staphylococcus aureus
    • DOI 10.1016/j.snb.2005.04.030, PII S0925400505004545
    • Subramanian A, Irudayaraj J, Ryan T (2006) Mono and dithiol surfaces on surface plasmon resonance biosensors for detection of Staphylococcus aureus. Sens Actuators B: Chem 114(1):192-198 (Pubitemid 43276180)
    • (2006) Sensors and Actuators, B: Chemical , vol.114 , Issue.1 , pp. 192-198
    • Subramanian, A.1    Irudayaraj, J.2    Ryan, T.3
  • 114
    • 79958780638 scopus 로고    scopus 로고
    • Comparative assessment of tea quality by various analytical and sensory methods with emphasis on tea polyphenols
    • Sujith Kumar PV, Basheer S, Ravi R, Thakur MS (2011) Comparative assessment of tea quality by various analytical and sensory methods with emphasis on tea polyphenols. J Food Sci Technol 48:440-446
    • (2011) J Food Sci Technol , vol.48 , pp. 440-446
    • Sujith Kumar, P.V.1    Basheer, S.2    Ravi, R.3    Thakur, M.S.4
  • 115
    • 77956176992 scopus 로고    scopus 로고
    • Nanoengineered optical urea biosensor for estimating hemodialysis parameters in spent dialysate
    • Swati M, Hase NK, Srivastava R (2010) Nanoengineered optical urea biosensor for estimating hemodialysis parameters in spent dialysate. Anal Chim Acta 676:68-74
    • (2010) Anal Chim Acta , vol.676 , pp. 68-74
    • Swati, M.1    Hase, N.K.2    Srivastava, R.3
  • 117
    • 0035665974 scopus 로고    scopus 로고
    • A sensitive method for detecting AMP by utilizing polyphosphate-dependent ATP regeneration and bioluminescence reactions
    • DOI 10.1016/S1369-703X(01)00144-9, PII S1369703X01001449
    • Tanaka S, Kuroda A, Kato J, Ikeda T, Takiguchi N, Ohtake H (2001) A sensitive method for detecting AMP by utilizing polyphosphatedependent ATP regeneration and bioluminescence reactions. Biochem Eng J 19:193-197 (Pubitemid 34027317)
    • (2001) Biochemical Engineering Journal , vol.9 , Issue.3 , pp. 193-197
    • Tanaka, S.1    Kuroda, A.2    Kato, J.3    Ikeda, T.4    Takiguchi, N.5    Ohtake, H.6
  • 119
    • 27744599632 scopus 로고    scopus 로고
    • ATP bioluminescence assay for estimation of microbial populations of fresh-cut melon
    • Ukuku DO, Gerald GM, William FF (2005) ATP bioluminescence assay for estimation of microbial populations of fresh-cut melon.J Food Prot 68(11):2427-2432 (Pubitemid 41628420)
    • (2005) Journal of Food Protection , vol.68 , Issue.11 , pp. 2427-2432
    • Ukuku, D.O.1    Sapers, G.M.2    Fett, W.F.3
  • 120
    • 3042794760 scopus 로고    scopus 로고
    • Use of ATP bioluminescence to determine the bacterial sensitivity threshold to a bacteriocin
    • DOI 10.1002/bio.735
    • Valat C, Champiat D, N'Guyen TTT, Loiseau G, Raimbault M, Montet D (2003) Use of ATP bioluminescence to determine the bacterial sensitivity threshold to a bacteriocin. Luminescence 18:254-258 (Pubitemid 40326810)
    • (2003) Luminescence , vol.18 , Issue.5 , pp. 254-258
    • Valat, C.1    Champiat, D.2    N'Guyen, T.T.T.3    Loiseau, G.4    Raimbault, M.5    Montet, D.6
  • 122
    • 74449087608 scopus 로고    scopus 로고
    • An overview of foodborne pathogen detection: In the perspective of biosensors
    • Velusamy V, Arshak K, Korostynska O, Oliwa K, Adley C (2010) An overview of foodborne pathogen detection: in the perspective of biosensors. Biotechnol Adv 28:232-254
    • (2010) Biotechnol Adv , vol.28 , pp. 232-254
    • Velusamy, V.1    Arshak, K.2    Korostynska, O.3    Oliwa, K.4    Adley, C.5
  • 123
    • 82855160634 scopus 로고    scopus 로고
    • Fiber optic biosensor for the detection of Cd in milk
    • doi:10.4172/2155-6210.1000102
    • Verma N, Kumar S, Kaur H (2010) Fiber optic biosensor for the detection of Cd in milk. J Biosens Bioelectron 1:102.doi:10.4172/2155-6210.1000102
    • (2010) J Biosens Bioelectron , vol.1 , pp. 102
    • Verma, N.1    Kumar, S.2    Kaur, H.3
  • 124
    • 77957136014 scopus 로고    scopus 로고
    • Fabrication of localized surface plasmon resonance fiber probes using ionic selfassembled gold nanoparticles
    • Wan M, Luo P, Jin J, Xing J, Wang Z, Wong STC (2010) Fabrication of localized surface plasmon resonance fiber probes using ionic selfassembled gold nanoparticles. Sensors 10:6477-6487
    • (2010) Sensors , vol.10 , pp. 6477-6487
    • Wan, M.1    Luo, P.2    Jin, J.3    Xing, J.4    Wang, Z.5    Wong, S.T.C.6
  • 125
    • 0037064332 scopus 로고    scopus 로고
    • Tethered thiazole orange intercalating dye for development of fibre-optic nucleic acid biosensors
    • DOI 10.1016/S0003-2670(02)00671-2, PII S0003267002006712
    • Wang X, Krull UJ (2002) Tethered thiazole orange intercalating dye for development of fibre-optic nucleic acid biosensors. Anal Chim Acta 470(11):57-70 (Pubitemid 35304590)
    • (2002) Analytica Chimica Acta , vol.470 , Issue.1 , pp. 57-70
    • Wang, X.1    Krull, U.J.2
  • 126
    • 0019130787 scopus 로고
    • Buffer effects on ATP analysis by firefly luciferase
    • Webster JJ, Chang JC, Manley ER, Spivey HO, Franklin RL (1980)Buffer effects on ATP analysis by firefly luciferase. Anal Biochem 106(1):7-11 (Pubitemid 11246557)
    • (1980) Analytical Biochemistry , vol.106 , Issue.1 , pp. 7-11
    • Webster, J.J.1    Chang, J.C.2    Manley, E.R.3
  • 127
    • 7444238111 scopus 로고    scopus 로고
    • Immobilization of metallothionein as a sensitive biosensor chip for the detection of metal ions by surface plasmon resonance
    • Wu CM, Lin LY (2004) Immobilization of metallothionein as a sensitive biosensor chip for the detection of metal ions by surface plasmon resonance. Biosens Bioelectron 20(4):864-871
    • (2004) Biosens Bioelectron , vol.20 , Issue.4 , pp. 864-871
    • Wu, C.M.1    Lin, L.Y.2
  • 128
    • 55549138378 scopus 로고    scopus 로고
    • Surface plasmon resonance assay for chloramphenicol
    • Yuan J, Oliver R, Aguilar MI, Wu Y (2008) Surface plasmon resonance assay for chloramphenicol. Anal Chem 80(21):8329-8333
    • (2008) Anal Chem , vol.80 , Issue.21 , pp. 8329-8333
    • Yuan, J.1    Oliver, R.2    Aguilar, M.I.3    Wu, Y.4
  • 129
    • 67349152078 scopus 로고    scopus 로고
    • Surface plasmon resonance assay for chloramphenicol without surface regeneration
    • Yuan J, Addo J, Aguilar MI, Wu Y (2009) Surface plasmon resonance assay for chloramphenicol without surface regeneration. Anal Chim Act 390(1):97-99
    • (2009) Anal Chim Act , vol.390 , Issue.1 , pp. 97-99
    • Yuan, J.1    Addo, J.2    Aguilar, M.I.3    Wu, Y.4
  • 130
    • 34447340656 scopus 로고    scopus 로고
    • 5--luminol chemiluminescence detection
    • DOI 10.1021/jf070144y
    • Zhang Y, Zhang Z, Sun Y, Wei Y (2007) Development of an analytical method for the determination of â2-agonist residues in animal tissues by high-performance liquid chromatography with on-line electrogenerated [Cu(HIO6)2]5-luminol chemiluminescence detection.J Agric Food Chem 55(13):4949-4956 (Pubitemid 47056041)
    • (2007) Journal of Agricultural and Food Chemistry , vol.55 , Issue.13 , pp. 4949-4956
    • Zhang, Y.1    Zhang, Z.2    Sun, Y.3    Wei, Y.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.