메뉴 건너뛰기




Volumn 271, Issue 1-2, 2002, Pages 17-24

Improved fluoroimmunoassays using the dye Alexa Fluor 647 with the RAPTOR, a fiber optic biosensor

Author keywords

Alexa Fluor 647; Biosensor; Cy5; Fluorophore; Immunoassay

Indexed keywords

ALEXA FLUOR 647; FLUORESCENT DYE; IMMUNOGLOBULIN G ANTIBODY; POLYSTYRENE; RICIN; UNCLASSIFIED DRUG;

EID: 0037146794     PISSN: 00221759     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0022-1759(02)00327-7     Document Type: Article
Times cited : (88)

References (11)
  • 1
    • 0034945127 scopus 로고    scopus 로고
    • Water quality monitoring using an automated portable fiber optic biosensor: RAPTOR
    • Anderson G.P., Rowe-Taitt C.A. Water quality monitoring using an automated portable fiber optic biosensor: RAPTOR. Proc. SPIE. 4206:2001;58.
    • (2001) Proc. SPIE , vol.4206 , pp. 58
    • Anderson, G.P.1    Rowe-Taitt, C.A.2
  • 5
    • 0033166564 scopus 로고    scopus 로고
    • Rapid detection of Escherichia coli O157:H7 in ground beef using a fiber-optic biosensor
    • DeMarco D.R., Saaski E.W., McCrae D.A., Lim D.M. Rapid detection of Escherichia coli O157:H7 in ground beef using a fiber-optic biosensor. J. Food Prot. 62:1999;711.
    • (1999) J. Food Prot. , vol.62 , pp. 711
    • DeMarco, D.R.1    Saaski, E.W.2    McCrae, D.A.3    Lim, D.M.4
  • 6
    • 0033795017 scopus 로고    scopus 로고
    • Anomalous fluorescence enhancement of Cy3 and Cy3.5 versus anomalous fluorescence loss of Cy5 and Cy7 upon covalent linking to IgG and noncovalent binding to avidin
    • Gruber H.J., Hahn C.D., Kada G., Riener C.K., Harms G.S., Ahrer W., Dax T.G., Knaus H. Anomalous fluorescence enhancement of Cy3 and Cy3.5 versus anomalous fluorescence loss of Cy5 and Cy7 upon covalent linking to IgG and noncovalent binding to avidin. Bioconjug. Chem. 11:2000;696.
    • (2000) Bioconjug. Chem. , vol.11 , pp. 696
    • Gruber, H.J.1    Hahn, C.D.2    Kada, G.3    Riener, C.K.4    Harms, G.S.5    Ahrer, W.6    Dax, T.G.7    Knaus, H.8
  • 9
    • 0011442394 scopus 로고    scopus 로고
    • Assessment of the effects of increased fluorophore labeling on the binding ability of an antibody
    • McCormack T., O'Keeffe G., MacCraith B., O'Kennedy R. Assessment of the effects of increased fluorophore labeling on the binding ability of an antibody. Anal. Lett. 29:1996;953.
    • (1996) Anal. Lett. , vol.29 , pp. 953
    • McCormack, T.1    O'Keeffe, G.2    MacCraith, B.3    O'Kennedy, R.4
  • 11
    • 0030051517 scopus 로고    scopus 로고
    • Quantitating staphylococcal enterotoxin B in diverse media using a portable fiber optic biosensor
    • Tempelman L.A., King K.D., Anderson G.P., Ligler F.S. Quantitating staphylococcal enterotoxin B in diverse media using a portable fiber optic biosensor. Anal. Biochem. 223:1996;50.
    • (1996) Anal. Biochem. , vol.223 , pp. 50
    • Tempelman, L.A.1    King, K.D.2    Anderson, G.P.3    Ligler, F.S.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.