메뉴 건너뛰기




Volumn 6363 LNCS, Issue PART 3, 2010, Pages 303-310

Micro-force sensing in robot assisted membrane peeling for vitreoretinal surgery

Author keywords

Auditory Sensory Substitution; Cooperative Robot Control; Force Scaling; Force Sensing; Robotic Microsurgery; Vitreoretinal Surgery

Indexed keywords

COOPERATIVE ROBOT CONTROL; FORCE SCALING; FORCE SENSING; SENSORY SUBSTITUTION; VITREORETINAL SURGERY;

EID: 84863894953     PISSN: 03029743     EISSN: 16113349     Source Type: Book Series    
DOI: 10.1007/978-3-642-15711-0_38     Document Type: Conference Paper
Times cited : (86)

References (14)
  • 1
    • 84957065500 scopus 로고    scopus 로고
    • Surgical forces and tactile perception during retinal microsurgery
    • Taylor, C., Colchester, A. (eds.) MICCAI 1999. Springer, Heidelberg
    • Gupta, P.K., Jensen, P.S., de Juan, E.: Surgical forces and tactile perception during retinal microsurgery. In: Taylor, C., Colchester, A. (eds.) MICCAI 1999. LNCS, vol. 1679, pp. 1218-1225. Springer, Heidelberg (1999)
    • (1999) LNCS , vol.1679 , pp. 1218-1225
    • Gupta, P.K.1    Jensen, P.S.2    De Juan, E.3
  • 2
    • 0142258223 scopus 로고    scopus 로고
    • Toward active tremor canceling in handheld microsurgical instruments
    • Riviere, C., Ang, W.T., Khosla, P.: Toward active tremor canceling in handheld microsurgical instruments. IEEE Tr. Rob. & Aut. 19(5), 793-800 (2003)
    • (2003) IEEE Tr. Rob. & Aut. , vol.19 , Issue.5 , pp. 793-800
    • Riviere, C.1    Ang, W.T.2    Khosla, P.3
  • 5
    • 0142196055 scopus 로고    scopus 로고
    • A miniature microsurgical instrument tip force sensor for enhanced force feedback during robot-assisted manipulation
    • Berkelman, P., Whitcomb, L., Taylor, R., Jensen, P.: A miniature microsurgical instrument tip force sensor for enhanced force feedback during robot-assisted manipulation. IEEE TRA 19(5), 917-921 (2003)
    • (2003) IEEE TRA , vol.19 , Issue.5 , pp. 917-921
    • Berkelman, P.1    Whitcomb, L.2    Taylor, R.3    Jensen, P.4
  • 6
    • 67749130638 scopus 로고    scopus 로고
    • A sub-millimetric, 0.25 mN resolution fully integrated fiber-optic force-sensing tool for retinal microsurgery
    • Iordachita, I., Sun, Z., Balicki, M., Kang, J., Phee, S., Handa, J., Gehlbach, P., Taylor, R.: A sub-millimetric, 0.25 mN resolution fully integrated fiber-optic force-sensing tool for retinal microsurgery. JCARS 4(4), 383-390 (2009)
    • (2009) JCARS , vol.4 , Issue.4 , pp. 383-390
    • Iordachita, I.1    Sun, Z.2    Balicki, M.3    Kang, J.4    Phee, S.5    Handa, J.6    Gehlbach, P.7    Taylor, R.8
  • 7
    • 0033702453 scopus 로고    scopus 로고
    • Preliminary Experiments in Cooperative Human/Robert Force Control for Robot Assisted Microsurgical Manipulation
    • Kumar, R., Berkelman, P., Gupta, P., Barnes, A., Jensen, P.S., Whitcomb, L.L., Taylor, R.H.: Preliminary Experiments in Cooperative Human/Robert Force Control for Robot Assisted Microsurgical Manipulation. IEEE ICRA 1, 610-617 (2000)
    • (2000) IEEE ICRA , vol.1 , pp. 610-617
    • Kumar, R.1    Berkelman, P.2    Gupta, P.3    Barnes, A.4    Jensen, P.S.5    Whitcomb, L.L.6    Taylor, R.H.7
  • 8
    • 84958184069 scopus 로고    scopus 로고
    • Performance "Evaluation of a Cooperative Manipulation Microsurgical Assistant Robot Applied to Stapedotomy
    • Niessen, W.J., Viergever, M.A. (eds.) MICCAI 2001. Springer, Heidelberg
    • Berkelman, P., Rothbaum, D., Roy, J., Lang, S., Whitcomb, L., Hager, G., Jensen, P., de Juan, E., Taylor, R., Niparko, J.: Performance "Evaluation of a Cooperative Manipulation Microsurgical Assistant Robot Applied to Stapedotomy. In: Niessen, W.J., Viergever, M.A. (eds.) MICCAI 2001. LNCS, vol. 2208, pp. 1426-1429. Springer, Heidelberg (2001)
    • (2001) LNCS , vol.2208 , pp. 1426-1429
    • Berkelman, P.1    Rothbaum, D.2    Roy, J.3    Lang, S.4    Whitcomb, L.5    Hager, G.6    Jensen, P.7    De Juan, E.8    Taylor, R.9    Niparko, J.10
  • 9
    • 0031294799 scopus 로고    scopus 로고
    • Characteristics of hand motion of eye surgeons
    • Riviere, C., Rader, R., Khosla, P.: Characteristics of hand motion of eye surgeons. IEEE EMBS 4, 1690-1693 (1997)
    • (1997) IEEE EMBS , vol.4 , pp. 1690-1693
    • Riviere, C.1    Rader, R.2    Khosla, P.3
  • 12
    • 11144322925 scopus 로고    scopus 로고
    • Applied force during vitreoretinal microsurgery with handheld instruments
    • Jagtap, A.S., Riviere, C.N.: Applied force during vitreoretinal microsurgery with handheld instruments. In: Proc. IEEE Conf. on Eng. Med. Biol. Soc., vol. 4, pp. 2771-2773 (2004)
    • (2004) Proc. IEEE Conf. on Eng. Med. Biol. Soc. , vol.4 , pp. 2771-2773
    • Jagtap, A.S.1    Riviere, C.N.2
  • 13
    • 11144282530 scopus 로고    scopus 로고
    • Effect of sensory substitution on suture-manipulation forces for robotic surgical systems
    • DOI 10.1016/j.jtcvs.2004.05.029, PII S0022522304008876
    • Kitagawa, M., Dokko, D., Okamura, A., Yuh, D.: Effect of sensory substitution on suture manipulation forces for robotic surgical systems. JTCS 129(1), 151-158 (2005) (Pubitemid 40038108)
    • (2005) Journal of Thoracic and Cardiovascular Surgery , vol.129 , Issue.1 , pp. 151-158
    • Kitagawa, M.1    Dokko, D.2    Okamura, A.M.3    Yuh, D.D.4
  • 14
    • 0347510296 scopus 로고
    • The biomechanics of the normal and of the amputated upper extremities
    • Klopsteg, P.E., Wilson, P.D. (eds.) ch. 7, Hafner Pub. Co., New York
    • Taylor, C.L.: The biomechanics of the normal and of the amputated upper extremities. In: Klopsteg, P.E., Wilson, P.D. (eds.) Human limbs and their substitutes, ch. 7, pp. 169-221. Hafner Pub. Co., New York (1968)
    • (1968) Human Limbs and Their Substitutes , pp. 169-221
    • Taylor, C.L.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.