메뉴 건너뛰기




Volumn 4, Issue 6, 2009, Pages 517-526

A parallel robot to assist vitreoretinal surgery

Author keywords

Parallel mechanism; Surgical robot; Vitreoretinal surgery

Indexed keywords

ACCURACY; ARTICLE; COMPUTER ASSISTED SURGERY; COMPUTER PROGRAM; EYE SURGERY; HAND TREMOR; HUMAN; IN VITRO STUDY; INSTRUMENT STERILIZATION; MICROSURGERY; PRIORITY JOURNAL; ROBOTICS; SURGICAL TECHNIQUE; VITREORETINA SURGERY;

EID: 70350702547     PISSN: 18616410     EISSN: 18616429     Source Type: Journal    
DOI: 10.1007/s11548-009-0374-2     Document Type: Article
Times cited : (86)

References (21)
  • 1
    • 0142258223 scopus 로고    scopus 로고
    • Toward active tremor canceling in handheld microsurgical instruments
    • Riviere CN, Ang WT, Khosla PK (2003) Toward active tremor canceling in handheld microsurgical instruments. IEEE Trans Robot Autom 19(5):793-800
    • (2003) IEEE Trans Robot Autom , vol.19 , Issue.5 , pp. 793-800
    • Riviere, C.N.1    Ang, W.T.2    Khosla, P.K.3
  • 3
    • 0003688254 scopus 로고
    • Engineering data compendium: Human perception and performance
    • H.G. Anderson Aerospace Medical Research Laboratory
    • Boff KR, Lincoln JE (1988) Engineering data compendium: Human perception and performance. H.G. Anderson Aerospace Medical Research Laboratory
    • (1988)
    • Boff, K.R.1    Lincoln, J.E.2
  • 4
    • 2942687590 scopus 로고    scopus 로고
    • The chick chorioallantoic membrane as a model tissue for surgical retinal research and simulation
    • Leng T, Miller JM, Bilbao KV, Palanker DV, Huie P, Blumenkranz MS (2004) The chick chorioallantoic membrane as a model tissue for surgical retinal research and simulation. Retina 24(3):427-434
    • (2004) Retina , vol.24 , Issue.3 , pp. 427-434
    • Leng, T.1    Miller, J.M.2    Bilbao, K.V.3    Palanker, D.V.4    Huie, P.5    Blumenkranz, M.S.6
  • 5
    • 0027170688 scopus 로고
    • In vivo micropuncture of retinal vessels
    • Glucksberg M et al (1993) In vivo micropuncture of retinal vessels. Graefe's Arch Clini Exp Ophthalmol 231:405-407
    • (1993) Graefe's Arch Clini Exp Ophthalmol , vol.231 , pp. 405-407
    • Glucksberg, M.1
  • 6
    • 0026323602 scopus 로고
    • New ocular micromanipulator for measurements of retinal and vitreous physiologic parameters in the mammalian eye
    • Pournaras C et al (1991) New ocular micromanipulator for measurements of retinal and vitreous physiologic parameters in the mammalian eye. Exp Eye Res 53:723-727
    • (1991) Exp Eye Res , vol.53 , pp. 723-727
    • Pournaras, C.1
  • 7
    • 36349036047 scopus 로고    scopus 로고
    • Development and application of a new steady-hand manipulator for retinal surgery
    • Mitchell B et al (2007) Development and application of a new steady-hand manipulator for retinal surgery. In: IEEE international conference on robotics and automation, pp 623-629
    • (2007) IEEE International Conference on Robotics and Automation , pp. 623-629
    • Mitchell, B.1
  • 9
    • 33947301434 scopus 로고    scopus 로고
    • Robotic compensation of biological motion to enhance surgical accuracy
    • Riviere CN, Gangloff J, de Mathelin M (2006) Robotic compensation of biological motion to enhance surgical accuracy. In: Proceedings of the IEEE 94(9), pp 1705-1716
    • (2006) Proceedings of the IEEE , vol.94 , Issue.9 , pp. 1705-1716
    • Riviere, C.N.1    Gangloff, J.2    de Mathelin, M.3
  • 11
    • 0032801309 scopus 로고    scopus 로고
    • Evaluation of a telerobotic system to assist surgeons in microsurgery
    • Das H, Zak H, Johnson J (1999) Evaluation of a telerobotic system to assist surgeons in microsurgery. Comput Aided Surg 4(1):15-25
    • (1999) Comput Aided Surg , vol.4 , Issue.1 , pp. 15-25
    • Das, H.1    Zak, H.2    Johnson, J.3
  • 13
    • 38049164250 scopus 로고    scopus 로고
    • Feasibility study of intraocular robotic surgery with the da Vinci Surgical System
    • Bourla DH, Hubschman JP et al (2008) Feasibility study of intraocular robotic surgery with the da Vinci Surgical System. Retina 28(1):154-158
    • (2008) Retina , vol.28 , Issue.1 , pp. 154-158
    • Bourla, D.H.1    Hubschman, J.P.2
  • 14
    • 51649122028 scopus 로고    scopus 로고
    • Master manipulator with higher operability designed for micro neuro surgical system
    • Takahashi H et al (2008) Master manipulator with higher operability designed for micro neuro surgical system. In: IEEE international conference on robotics and automation, pp 3902-3907
    • (2008) IEEE International Conference on Robotics and Automation , pp. 3902-3907
    • Takahashi, H.1
  • 18
    • 0026845437 scopus 로고
    • Direct kinematics and assembly modes of parallel manipulators
    • Merlet J-P (1992) Direct kinematics and assembly modes of parallel manipulators. Int J Robot Res 11(2):150-162
    • (1992) Int J Robot Res , vol.11 , Issue.2 , pp. 150-162
    • Merlet, J.-P.1
  • 19
    • 41949132675 scopus 로고    scopus 로고
    • Randomized optimal design of parallel manipulators
    • Lou Y, Liu G, Li Z (2008) Randomized optimal design of parallel manipulators. IEEE Trans Autom Sci Eng 5(2):223-233
    • (2008) IEEE Trans Autom Sci Eng , vol.5 , Issue.2 , pp. 223-233
    • Lou, Y.1    Liu, G.2    Li, Z.3
  • 20
    • 1242298662 scopus 로고    scopus 로고
    • Optimum design of parallel kinematic toolheads with genetic algorithms
    • Zhang D, Xu Z, Mechefske CM, Xi F (2004) Optimum design of parallel kinematic toolheads with genetic algorithms. Robotica 22:77-84
    • (2004) Robotica , vol.22 , pp. 77-84
    • Zhang, D.1    Xu, Z.2    Mechefske, C.M.3    Xi, F.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.