메뉴 건너뛰기




Volumn 81, Issue 1, 2012, Pages 230-237

In-line NIR spectroscopy for the understanding of polymer-drug interaction during pharmaceutical hot-melt extrusion

Author keywords

Continuous production; Hot melt extrusion (HME); In line monitoring; NIR spectroscopy; Process Analytical Technology (PAT)

Indexed keywords

METOPROLOL TARTRATE; POVIDONE;

EID: 84861098743     PISSN: 09396411     EISSN: 18733441     Source Type: Journal    
DOI: 10.1016/j.ejpb.2012.01.001     Document Type: Article
Times cited : (72)

References (35)
  • 1
    • 85111386879 scopus 로고    scopus 로고
    • Hot-melt extrusion technique: A review
    • R. Chokshi, and H. Zia Hot-melt extrusion technique: a review Iran J. Pharm. Res. 3 2004 3 16
    • (2004) Iran J. Pharm. Res. , vol.3 , pp. 3-16
    • Chokshi, R.1    Zia, H.2
  • 2
    • 1842865536 scopus 로고    scopus 로고
    • Melt extrusion: From process to drug delivery technology
    • J. Breitenbach Melt extrusion: from process to drug delivery technology Eur. J. Pharm. Biopharm. 54 2002 107 117
    • (2002) Eur. J. Pharm. Biopharm. , vol.54 , pp. 107-117
    • Breitenbach, J.1
  • 6
    • 36549042006 scopus 로고    scopus 로고
    • Solid dispersions as strategy to improve oral bioavailability of poor water soluble drugs
    • T. Vasconcelos, B. Sarmento, and P. Costa Solid dispersions as strategy to improve oral bioavailability of poor water soluble drugs Drug Discov. Today 12 2007 1068 1075
    • (2007) Drug Discov. Today , vol.12 , pp. 1068-1075
    • Vasconcelos, T.1    Sarmento, B.2    Costa, P.3
  • 8
    • 0030638567 scopus 로고    scopus 로고
    • Characteristics and significance of the amorphous state in pharmaceutical systems
    • B.C. Hancock, and G. Zografi Characteristics and significance of the amorphous state in pharmaceutical systems J. Pharm. Sci. 86 1997 1 12
    • (1997) J. Pharm. Sci. , vol.86 , pp. 1-12
    • Hancock, B.C.1    Zografi, G.2
  • 9
    • 78650709887 scopus 로고    scopus 로고
    • Raman spectroscopy for the in-line polymer-drug quantification and solid state characterization during a pharmaceutical hot-melt extrusion process
    • L. Saerens, L. Dierickx, B. Lenain, C. Vervaet, J.P. Remon, and T. De Beer Raman spectroscopy for the in-line polymer-drug quantification and solid state characterization during a pharmaceutical hot-melt extrusion process Eur. J. Pharm. Biopharm. 77 2011 158 163
    • (2011) Eur. J. Pharm. Biopharm. , vol.77 , pp. 158-163
    • Saerens, L.1    Dierickx, L.2    Lenain, B.3    Vervaet, C.4    Remon, J.P.5    De Beer, T.6
  • 10
    • 1542268927 scopus 로고    scopus 로고
    • Twin screw granulation as a simple and efficient tool for continuous wet granulation
    • E.I. Keleb, A. Vermeire, C. Vervaet, and J.P. Remon Twin screw granulation as a simple and efficient tool for continuous wet granulation Int. J. Pharm. 273 2004 183 194
    • (2004) Int. J. Pharm. , vol.273 , pp. 183-194
    • Keleb, E.I.1    Vermeire, A.2    Vervaet, C.3    Remon, J.P.4
  • 11
    • 18644363185 scopus 로고    scopus 로고
    • Continuous granulation in the pharmaceutical industry
    • C. Vervaet, and J.P. Remon Continuous granulation in the pharmaceutical industry Chem. Eng. Sci. 60 2005 3949 3957
    • (2005) Chem. Eng. Sci. , vol.60 , pp. 3949-3957
    • Vervaet, C.1    Remon, J.P.2
  • 14
    • 34247350310 scopus 로고    scopus 로고
    • Near-infrared spectroscopy applications in pharmaceutical analysis
    • J. Luypaert, D.S. Massart, and Y. Vander Heyden Near-infrared spectroscopy applications in pharmaceutical analysis Talanta 72 2007 865 883
    • (2007) Talanta , vol.72 , pp. 865-883
    • Luypaert, J.1    Massart, D.S.2    Vander Heyden, Y.3
  • 15
    • 33846850352 scopus 로고    scopus 로고
    • Near infrared spectroscopy in the development of solid dosage forms
    • E. Räsänen, and N. Sandler Near infrared spectroscopy in the development of solid dosage forms J. Pharm. Pharmacol. 59 2007 147 159
    • (2007) J. Pharm. Pharmacol. , vol.59 , pp. 147-159
    • Räsänen, E.1    Sandler, N.2
  • 16
    • 18844407047 scopus 로고    scopus 로고
    • Vibrational spectroscopic and ultrasound analysis for in-process characterization of high-density polyethylene/polypropylene blends during melt extrusion
    • S.E. Barnes, E.C. Brown, M.G. Sibley, H.G.M. Edwards, I.J. Scowen, and P.D. Coates Vibrational spectroscopic and ultrasound analysis for in-process characterization of high-density polyethylene/polypropylene blends during melt extrusion Appl. Spectrosc. 59 2005 611 619
    • (2005) Appl. Spectrosc. , vol.59 , pp. 611-619
    • Barnes, S.E.1    Brown, E.C.2    Sibley, M.G.3    Edwards, H.G.M.4    Scowen, I.J.5    Coates, P.D.6
  • 17
    • 0042882126 scopus 로고    scopus 로고
    • In-process vibrational spectroscopy and ultrasound measurements in polymer melt extrusion
    • P.C. Coates, S.E. Barnes, M.G. Sibley, E.C. Brown, H.G.M. Edwards, and I.J. Scowen In-process vibrational spectroscopy and ultrasound measurements in polymer melt extrusion Polymer 44 2003 5937 5949
    • (2003) Polymer , vol.44 , pp. 5937-5949
    • Coates, P.C.1    Barnes, S.E.2    Sibley, M.G.3    Brown, E.C.4    Edwards, H.G.M.5    Scowen, I.J.6
  • 18
    • 0033552071 scopus 로고    scopus 로고
    • Near infrared (NIR) spectroscopy for in-line monitoring of polymer extrusion processes
    • T. Rohe, W. Becker, S. Kölle, N. Eisenreich, and P. Eyerer Near infrared (NIR) spectroscopy for in-line monitoring of polymer extrusion processes Talanta 50 1999 283 290
    • (1999) Talanta , vol.50 , pp. 283-290
    • Rohe, T.1    Becker, W.2    Kölle, S.3    Eisenreich, N.4    Eyerer, P.5
  • 19
    • 15244361194 scopus 로고    scopus 로고
    • Vibrational spectroscopic and ultrasound analysis for the in-process monitoring of poly(ethylene vinyl acetate) copolymer composition during melt extrusion
    • S.E. Barnes, E.C. Brown, M.G. Sibley, H.G.M. Edwards, and P.D. Coates Vibrational spectroscopic and ultrasound analysis for the in-process monitoring of poly(ethylene vinyl acetate) copolymer composition during melt extrusion Analyst 130 2005 286 292
    • (2005) Analyst , vol.130 , pp. 286-292
    • Barnes, S.E.1    Brown, E.C.2    Sibley, M.G.3    Edwards, H.G.M.4    Coates, P.D.5
  • 21
    • 0032499354 scopus 로고    scopus 로고
    • In-line fibre-optic near-infrared spectroscopy: Monitoring of rheological properties in an extrusion process. Part i
    • M.G. Hansen, and S. Vedula In-line fibre-optic near-infrared spectroscopy: monitoring of rheological properties in an extrusion process. Part I J. Appl. Polym. Sci. 68 1998 859 872
    • (1998) J. Appl. Polym. Sci. , vol.68 , pp. 859-872
    • Hansen, M.G.1    Vedula, S.2
  • 23
    • 31044445710 scopus 로고    scopus 로고
    • Combination of NIR, Raman, ultrasonic and dielectric spectroscopy for in-line monitoring of the extrusion process
    • I. Alig, D. Fischer, D. Lellinger, and B. Steinhoff Combination of NIR, Raman, ultrasonic and dielectric spectroscopy for in-line monitoring of the extrusion process Macromol. Symp. 230 2005 51 58
    • (2005) Macromol. Symp. , vol.230 , pp. 51-58
    • Alig, I.1    Fischer, D.2    Lellinger, D.3    Steinhoff, B.4
  • 24
    • 2442453472 scopus 로고    scopus 로고
    • Ultrasonic and NIR determination of filler concentration in polymer melt flows in extrusion
    • S.E. Barnes, G.D. Smith, E.C. Brown, H.G.M. Edwards, and P.D. Coates Ultrasonic and NIR determination of filler concentration in polymer melt flows in extrusion ANTEC 3 2004 3813 3817
    • (2004) ANTEC , vol.3 , pp. 3813-3817
    • Barnes, S.E.1    Smith, G.D.2    Brown, E.C.3    Edwards, H.G.M.4    Coates, P.D.5
  • 26
    • 0031722109 scopus 로고    scopus 로고
    • Prediction of intestinal drug absorption properties by three-dimensional solubility parameters
    • J. Breitkreutz Prediction of intestinal drug absorption properties by three-dimensional solubility parameters Pharm. Res. 15 1998 1370 1375
    • (1998) Pharm. Res. , vol.15 , pp. 1370-1375
    • Breitkreutz, J.1
  • 28
    • 0022040067 scopus 로고
    • Near infrared analysis
    • D.E. Honigs Near infrared analysis Anal. Instrum. 14 1985 1 62
    • (1985) Anal. Instrum. , vol.14 , pp. 1-62
    • Honigs, D.E.1
  • 29
    • 0035845751 scopus 로고    scopus 로고
    • Selection of excipients for melt extrusion with two poorly water-soluble drugs by solubility parameter calculation and thermal analysis
    • A. Forster, J. Hempenstall, I. Tucker, and T. Rades Selection of excipients for melt extrusion with two poorly water-soluble drugs by solubility parameter calculation and thermal analysis Int. J. Pharm. 226 2001 147 161
    • (2001) Int. J. Pharm. , vol.226 , pp. 147-161
    • Forster, A.1    Hempenstall, J.2    Tucker, I.3    Rades, T.4
  • 32
    • 67549127536 scopus 로고    scopus 로고
    • Near-infrared analysis of hydrogen-bonding in glass- and rubber-state amorphous saccharide solids
    • K. Izutsu, Y. Hiyama, C. Yomota, and T. Kawanishi Near-infrared analysis of hydrogen-bonding in glass- and rubber-state amorphous saccharide solids AAPS Pharm. Sci. Technol. 10 2009 524 529
    • (2009) AAPS Pharm. Sci. Technol. , vol.10 , pp. 524-529
    • Izutsu, K.1    Hiyama, Y.2    Yomota, C.3    Kawanishi, T.4
  • 34
    • 40849119736 scopus 로고    scopus 로고
    • Characterisation of solid dispersions of paracetamol and EUDRAGIT® e prepared by hot-melt extrusion using thermal, microthermal and spectroscopic analysis
    • S. Qi, A. Gryczke, P. Belton, and D.Q.M. Craig Characterisation of solid dispersions of paracetamol and EUDRAGIT® E prepared by hot-melt extrusion using thermal, microthermal and spectroscopic analysis Int. J. Pharm. 354 2008 158 167
    • (2008) Int. J. Pharm. , vol.354 , pp. 158-167
    • Qi, S.1    Gryczke, A.2    Belton, P.3    Craig, D.Q.M.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.