메뉴 건너뛰기




Volumn 31, Issue 5, 2012, Pages 1086-1099

Closed-form inverse kinematics for interventional C-Arm X-Ray imaging with six degrees of freedom: Modeling and application

Author keywords

C arm positioning; closed form inverse kinematics; Computer aided surgery; parallax free X ray image stitching

Indexed keywords

C-ARM FLUOROSCOPES; C-ARM POSITIONING; C-ARM SYSTEMS; CARTESIAN SPACE; CLOSED FORM; CLOSED FORM SOLUTIONS; COMPUTER AIDED SURGERY; DESIRED POSITION; EASE-OF-USE; INTERVENTIONAL; INTERVENTIONAL IMAGING; INVERSE KINEMATICS PROBLEM; KINEMATIC CHAIN; LONG BONE; METRIC MEASUREMENT; ORTHOPEDIC SURGERY; SIX DEGREES OF FREEDOM; SIX-DOF; SURGICAL TASKS; TABLE MOVEMENT; VISUAL QUALITIES; WORKING SPACE; X-RAY IMAGE; XRAY IMAGING;

EID: 84860650517     PISSN: 02780062     EISSN: None     Source Type: Journal    
DOI: 10.1109/TMI.2012.2185708     Document Type: Article
Times cited : (24)

References (40)
  • 1
    • 31344455712 scopus 로고    scopus 로고
    • Literature review of current techniques for the insertion of distal screws into intramedullary locking nails
    • DOI 10.1016/j.injury.2005.09.009, PII S0020138305003803
    • L. D. M. Nokes, "Literature review of current techniques for the insertion of distal screws into intramedullary locking nails, " Injury, vol. 37, no. 2, pp. 109-119, Feb. 2006. (Pubitemid 43138971)
    • (2006) Injury , vol.37 , Issue.2 , pp. 109-119
    • Whatling, G.M.1    Nokes, L.D.M.2
  • 2
    • 33644877786 scopus 로고    scopus 로고
    • Pedicle screw placement in the thoracic spine: A comparison of image-guided and manual techniques in cadavers
    • Jun.
    • R. Hart, B. Hansen, M. Shea, F. Hsu, and G. Anderson, "Pedicle screw placement in the thoracic spine: A comparison of image-guided and manual techniques in cadavers, " Spine, vol. 30, no. 12, pp. 326-331, Jun. 2005.
    • (2005) Spine , vol.30 , Issue.12 , pp. 326-331
    • Hart, R.1    Hansen, B.2    Shea, M.3    Hsu, F.4    Anderson, G.5
  • 4
    • 35948991068 scopus 로고    scopus 로고
    • Navigating the fluoroscope's C-arm back into position: An accurate and practicable solution to cut radiation and optimize intraoperative workflow
    • DOI 10.1097/BOT.0b013e318158fd42, PII 0000513120071100000004
    • F. Matthews, D. J. Hoigne, M. Weiser, G. A. Wanner, P. Regazzoni, N. Suhm, and P. Messmer, "Navigating the fluoroscope's C-arm back into position: An accurate and practicable solution to cut radiation and optimize intraoperative workflow, " J. Orthopaedic Trauma, vol. 21, no. 10, pp. 687-692, Dec. 2007. (Pubitemid 350073452)
    • (2007) Journal of Orthopaedic Trauma , vol.21 , Issue.10 , pp. 687-692
    • Matthews, F.1    Hoigne, D.J.2    Weiser, M.3    Wanner, G.A.4    Regazzoni, P.5    Suhm, N.6    Messmer, P.7
  • 5
  • 6
    • 34547519444 scopus 로고    scopus 로고
    • Closed-form inverse kinematic solution for fluoroscopic C-arms
    • DOI 10.1163/156855307780851957
    • L. Matthaeus, N. Binder, C. Bodensteiner, and A. Schweikard, "Closedform inverse kinematic solution for fluoroscopic C-arms, " Adv. Robot., vol. 21, no. 8, pp. 869-886, 2007. (Pubitemid 47184835)
    • (2007) Advanced Robotics , vol.21 , Issue.8 , pp. 869-886
    • Matthaus, L.1    Binder, N.2    Bodensteiner, C.3    Schweikard, A.4
  • 7
    • 84860659708 scopus 로고    scopus 로고
    • Intraoperative positioning of mobile C-arms using artificial fluoroscopy
    • Mar.
    • P. Dressel, L. Wang, O. Kutter, J. Traub, S. Heining, and N. Navab, "Intraoperative positioning of mobile C-arms using artificial fluoroscopy, " in Proc. SPIE, Mar. 2010, vol. 7625, no. 1, pp. 762 506-762 506-6.
    • (2010) Proc. SPIE , vol.7625 , Issue.1 , pp. 762506-7625066
    • Dressel, P.1    Wang, L.2    Kutter, O.3    Traub, J.4    Heining, S.5    Navab, N.6
  • 10
    • 70350452789 scopus 로고    scopus 로고
    • A language for effective communication between surgeons and radiographers in trauma theatre
    • Sep.
    • S. Chaganti, D. Kumar, S. Patil, and P. Alderman, "A language for effective communication between surgeons and radiographers in trauma theatre, " Ann. R. Coll. Surg. Eng., vol. 91, no. 6, pp. 509-512, Sep. 2009.
    • (2009) Ann. R. Coll. Surg. Eng. , vol.91 , Issue.6 , pp. 509-512
    • Chaganti, S.1    Kumar, D.2    Patil, S.3    Alderman, P.4
  • 12
    • 0034463666 scopus 로고    scopus 로고
    • Accuracy of fluoroscopically assisted laser targeting of the cadaveric thoracic and lumbar spine to place transpedicular screws
    • DOI 10.1097/00002517-200010000-00007
    • R. M. Schwend, P. J. Dewire, and T. M. Kowalski, "Accuracy of fluoroscopically assisted laser targeting of the cadaveric thoracic and lumbar spine to place transpedicular screws, " J. Spinal Disorders, vol. 13, no. 5, pp. 412-418, Oct. 2000. (Pubitemid 32199482)
    • (2000) Journal of Spinal Disorders , vol.13 , Issue.5 , pp. 412-418
    • Schwend, R.M.1    Dewire, P.J.2    Kowalski, J.M.3
  • 13
    • 0036090783 scopus 로고    scopus 로고
    • Radiation exposure using laser aiming guide in orthopaedic procedures
    • DOI 10.1046/j.1445-2197.2002.02406.x
    • I. Harris, P. M. Walker, and L. Trieu, "Radiation exposure using laser aiming guide in orthopaedic procedures, " ANZ J. Surg., vol. 72, no. 5, pp. 349-351, May 2002. (Pubitemid 34535388)
    • (2002) ANZ Journal of Surgery , vol.72 , Issue.5 , pp. 349-351
    • Harris, I.1    Walker, P.M.2    Trieu, L.3
  • 14
    • 34548386243 scopus 로고    scopus 로고
    • C-arm laser psitioning device to facilitate percutaneous renal access
    • DOI 10.1016/j.urology.2007.05.013, PII S0090429507005973
    • R. Ko and H. Razvi, "C-arm laser positioning device to facilitate percutaneous renal access, " Urology, vol. 70, no. 2, pp. 360-361, Aug. 2007. (Pubitemid 47362276)
    • (2007) Urology , vol.70 , Issue.2 , pp. 360-361
    • Ko, R.1    Razvi, H.2
  • 16
    • 0022130025 scopus 로고
    • Obstacle avoidance for kinematically redundant manipulators in dynamically varying environments
    • A. A. Maciejewski and C. A. Klein, "Obstacle avoidance for kinematically redundant manipulators in dynamically varying environments, " Int. J. Robot. Res., vol. 4, no. 3, pp. 109-117, 1985.
    • (1985) Int. J. Robot. Res. , vol.4 , Issue.3 , pp. 109-117
    • MacIejewski, A.A.1    Klein, C.A.2
  • 17
    • 85031783830 scopus 로고
    • Dynamic manipulability of robot manipulators
    • Mar.
    • T. Yoshikawa, "Dynamic manipulability of robot manipulators, " in Proc. IEEE Int. Conf. Robot. Automat., Mar. 1985, pp. 1033-1038.
    • (1985) Proc. IEEE Int. Conf. Robot. Automat. , pp. 1033-1038
    • Yoshikawa, T.1
  • 18
    • 0022076932 scopus 로고
    • Manipulability of robotic mechanisms
    • Jun.
    • T. Yoshikawa, "Manipulability of robotic mechanisms, " Int. J. Robot. Res., vol. 4, no. 2, pp. 3-9, Jun. 1985.
    • (1985) Int. J. Robot. Res. , vol.4 , Issue.2 , pp. 3-9
    • Yoshikawa, T.1
  • 19
    • 0022559423 scopus 로고
    • Manipulator inverse kinematic solutions based on vector formulations and damped least-squares methods
    • DOI 10.1109/TSMC.1986.289285
    • C. W. Wampler, II, "Manipulator inverse kinematic solutions based on vector formulations and damped least-squares methods, " IEEE Trans. Syst. Man Cybern., vol. 16, no. 1, pp. 93-101, Jan. 1986. (Pubitemid 16187854)
    • (1986) IEEE Transactions on Systems, Man and Cybernetics , vol.16 , Issue.1 , pp. 93-101
    • Wampler II, C.W.1
  • 21
    • 33751205971 scopus 로고    scopus 로고
    • Selectively damped least squares for inverse kinematics
    • S. R. Buss and J.-S. Kim, "Selectively damped least squares for inverse kinematics, " J. Graphics, GPU, Game Tools, vol. 10, no. 3, pp. 37-49, 2005.
    • (2005) J. Graphics, GPU, Game Tools , vol.10 , Issue.3 , pp. 37-49
    • Buss, S.R.1    Kim, J.-S.2
  • 23
    • 79955871484 scopus 로고    scopus 로고
    • Closed-form inverse kinematics for intra-operative mobile C-arm positioning with six degrees of freedom
    • L. Wang, R. Zou, S. Weidert, J. Landes, E. Euler, D. Burschka, and N. Navab, "Closed-form inverse kinematics for intra-operative mobile C-arm positioning with six degrees of freedom, " in Proc. SPIE, Mar. 2011, vol. 7964, no. 1, pp. 79 641A-79 641A-6.
    • Proc. SPIE, Mar. 2011 , vol.7964 , Issue.1
    • Wang, L.1    Zou, R.2    Weidert, S.3    Landes, J.4    Euler, E.5    Burschka, D.6    Navab, N.7
  • 24
    • 85103590248 scopus 로고
    • A kinematic notation for lower-pair mechanisms based on matrices
    • J. Denavit and R. S. Hartenberg, "A kinematic notation for lower-pair mechanisms based on matrices, " Trans. ASME J. Appl. Mech., vol. 23, pp. 215-221, 1955.
    • (1955) Trans. ASME J. Appl. Mech. , vol.23 , pp. 215-221
    • Denavit, J.1    Hartenberg, R.S.2
  • 28
    • 0030106027 scopus 로고    scopus 로고
    • A robotics toolbox for MATLAB
    • P. Corke, "A robotics toolbox for MATLAB, " IEEE Robot. Autom. Mag., vol. 3, no. 1, pp. 24-32, Mar. 1996. (Pubitemid 126553108)
    • (1996) IEEE Robotics and Automation Magazine , vol.3 , Issue.1 , pp. 24-32
    • Corke, P.I.1
  • 29
    • 33745316522 scopus 로고    scopus 로고
    • Computer-assisted analysis of lower limb geometry: Higher intraobserver reliability compared to conventional method
    • DOI 10.1080/10929080600628985, PII G41327074856154
    • S. Hankemeier, T. Gosling, M. Richter, T. Hufner, C. Hochhausen, and C. Krettek, "Computer-assisted analysis of lower limb geometry: Higher intraobserver reliability compared to conventional method, " Comput. Aided Surg., vol. 11, no. 2, pp. 81-86, 2006. (Pubitemid 43932726)
    • (2006) Computer Aided Surgery , vol.11 , Issue.2 , pp. 81-86
    • Hankemeier, S.1    Gosling, T.2    Richter, M.3    Hufner, T.4    Hochhausen, C.5    Krettek, C.6
  • 30
    • 0346076621 scopus 로고    scopus 로고
    • Long bone panoramas from fluoroscopic X-ray images
    • Jan.
    • Z. Yaniv and L. Joskowicz, "Long bone panoramas from fluoroscopic X-ray images, " IEEE Trans. Med. Imag., vol. 23, no. 1, pp. 26-35, Jan. 2004.
    • (2004) IEEE Trans. Med. Imag. , vol.23 , Issue.1 , pp. 26-35
    • Yaniv, Z.1    Joskowicz, L.2
  • 31
    • 33846594269 scopus 로고    scopus 로고
    • Image fusion for intraoperative control of axis in long bone fracture treatment
    • DOI 10.1007/s00068-006-5159-5
    • P. Messmer, F. Matthews, C. Wullschleger, R. Hgli, P. Regazzoni, and A. L. Jacob, "Image fusion for intraoperative control of axis in long bone fracture treatment, " Eur. J. Trauma, vol. 32, no. 6, pp. 555-561, Dec. 2006. (Pubitemid 46175358)
    • (2006) European Journal of Trauma , vol.32 , Issue.6 , pp. 555-561
    • Messmer, P.1    Matthews, F.2    Wullschleger, C.3    Hugli, R.4    Regazzoni, P.5    Jacob, A.L.6
  • 32
    • 0030421708 scopus 로고    scopus 로고
    • OBBTree: A hierarchical structure for rapid interference detection
    • S. Gottschalk, M. C. Lin, and D. Manocha, "OBBTree: A hierarchical structure for rapid interference detection, " in SIGGRAPH, 1996, pp. 171-180.
    • (1996) SIGGRAPH , pp. 171-180
    • Gottschalk, S.1    Lin, M.C.2    Manocha, D.3
  • 33
    • 77954224040 scopus 로고    scopus 로고
    • Camera augmented mobile C-arm (CAMC): Calibration, accuracy study and clinical applications
    • Jul.
    • N. Navab, S. M. Heining, and J. Traub, "Camera augmented mobile C-arm (CAMC): Calibration, accuracy study and clinical applications, " IEEE Trans. Med. Imag., vol. 29, no. 7, pp. 1412-1423, Jul. 2010.
    • (2010) IEEE Trans. Med. Imag. , vol.29 , Issue.7 , pp. 1412-1423
    • Navab, N.1    Heining, S.M.2    Traub, J.3
  • 35
    • 0033697614 scopus 로고    scopus 로고
    • Recovering projection geometry: How a cheap camera can outperform an expensive stereo system
    • M. M. Mischke and N. Navab, "Recovering projection geometry: How a cheap camera can outperform an expensive stereo system, " in IEEE Conf. Comput. Vis. Pattern Recognit., 2000, vol. 1, pp. 193-200.
    • (2000) IEEE Conf. Comput. Vis. Pattern Recognit. , vol.1 , pp. 193-200
    • Mischke, M.M.1    Navab, N.2
  • 38
    • 58849114493 scopus 로고    scopus 로고
    • Medial opening wedge high-tibial osteotomy using a kinematic navigation system versus a conventional method: A 1-year retrospective, comparative study
    • Oct.
    • S. Kim, Y. Koh, Y. Chun, Y. Kim, Y. Park, and C. Sung, "Medial opening wedge high-tibial osteotomy using a kinematic navigation system versus a conventional method: A 1-year retrospective, comparative study, " Knee Surgery, Sports Traumatol., Arthroscopy, vol. 17, no. 2, pp. 128-134, Oct. 2008.
    • (2008) Knee Surgery, Sports Traumatol., Arthroscopy , vol.17 , Issue.2 , pp. 128-134
    • Kim, S.1    Koh, Y.2    Chun, Y.3    Kim, Y.4    Park, Y.5    Sung, C.6
  • 39
    • 4043104035 scopus 로고    scopus 로고
    • Alignment in total knee arthroplasty. A comparison of computer-assisted surgery with the conventional technique
    • DOI 10.1302/0301-620X.86B5.14927
    • H. Baethis, L. Perlick, M. Tingart, C. Luering, D. Zurakowski, and J. Grifka, "Alignment in total knee arthroplasty. A comparison of computer-assisted surgery with the conventional technique, " J. Bone Joint Surg. Br. Vol., vol. 86, no. 5, pp. 682-687, Jul. 2004. (Pubitemid 39077216)
    • (2004) Journal of Bone and Joint Surgery - Series B , vol.86 , Issue.5 , pp. 682-687
    • Bathis, H.1    Perlick, L.2    Tingart, M.3    Luring, C.4    Zurakowski, D.5    Grifka, J.6
  • 40
    • 35948948171 scopus 로고    scopus 로고
    • Frontal plane knee alignment: A call for standardized measurement
    • T. D. V. Cooke, E. A. Sled, and R. A. Scudamore, "Frontal plane knee alignment: A call for standardized measurement, " J. Rheumatol., vol. 34, no. 9, pp. 1796-1801, Sep. 2007. (Pubitemid 350067636)
    • (2007) Journal of Rheumatology , vol.34 , Issue.9 , pp. 1796-1801
    • Cooke, T.D.V.1    Sled, E.A.2    Scudamore, R.A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.