메뉴 건너뛰기




Volumn 70, Issue 2, 2007, Pages 360-361

C-Arm Laser Positioning Device to Facilitate Percutaneous Renal Access

Author keywords

[No Author keywords available]

Indexed keywords

ARTICLE; DEVICE; FLUOROSCOPY; LASER; NEPHROLITHOTOMY; PRIORITY JOURNAL; SURGICAL APPROACH; SURGICAL TECHNIQUE;

EID: 34548386243     PISSN: 00904295     EISSN: 15279995     Source Type: Journal    
DOI: 10.1016/j.urology.2007.05.013     Document Type: Article
Times cited : (12)

References (11)
  • 1
    • 0034119293 scopus 로고    scopus 로고
    • The application of ALARA for occupational exposures. NCRP Statement No. 8, issued June 8, 1999
    • National Council on Radiation Protection
    • National Council on Radiation Protection. The application of ALARA for occupational exposures. NCRP Statement No. 8, issued June 8, 1999. Health Phys 78 (2000) S76-S77
    • (2000) Health Phys , vol.78
  • 2
    • 23744487430 scopus 로고    scopus 로고
    • Radiation exposure and the urologist: what are the risks?
    • Hellawell G.O., Mutch S.J., Thevendran G., et al. Radiation exposure and the urologist: what are the risks?. J Urol 174 (2005) 948-952
    • (2005) J Urol , vol.174 , pp. 948-952
    • Hellawell, G.O.1    Mutch, S.J.2    Thevendran, G.3
  • 3
    • 0024323142 scopus 로고
    • Radiation safety during percutaneous nephrolithotomy
    • Inglis J.A., Tolley D.A., and Law J. Radiation safety during percutaneous nephrolithotomy. Br J Urol 63 (1989) 591-593
    • (1989) Br J Urol , vol.63 , pp. 591-593
    • Inglis, J.A.1    Tolley, D.A.2    Law, J.3
  • 4
    • 0031204509 scopus 로고    scopus 로고
    • Radiation exposure to the orthopaedic surgical team during fluoroscopy: "how far away is far enough?
    • Mehlman C.T., and DiPasquale T.G. Radiation exposure to the orthopaedic surgical team during fluoroscopy: "how far away is far enough?. " J Orthop Trauma 11 (1997) 392-398
    • (1997) " J Orthop Trauma , vol.11 , pp. 392-398
    • Mehlman, C.T.1    DiPasquale, T.G.2
  • 5
    • 0036934821 scopus 로고    scopus 로고
    • Radiation protection during percutaneous nephrolithotomy: a new urologic surgery radiation shield
    • Yang R.M., Morgan T., and Bellman G.C. Radiation protection during percutaneous nephrolithotomy: a new urologic surgery radiation shield. J Endourol 16 (2002) 727-731
    • (2002) J Endourol , vol.16 , pp. 727-731
    • Yang, R.M.1    Morgan, T.2    Bellman, G.C.3
  • 6
    • 0031783601 scopus 로고    scopus 로고
    • Stereotactic mechanical percutaneous renal access
    • Cadeddu J.A., Stoianovici D., Chen R.N., et al. Stereotactic mechanical percutaneous renal access. J Endourol 12 (1998) 121-125
    • (1998) J Endourol , vol.12 , pp. 121-125
    • Cadeddu, J.A.1    Stoianovici, D.2    Chen, R.N.3
  • 7
    • 0034129962 scopus 로고    scopus 로고
    • Percutaneous nephrostomy: placement under laser guidance and real-time CT fluoroscopy
    • LeMaitre L., Mestdagh P., Marecaux-Delomez J., et al. Percutaneous nephrostomy: placement under laser guidance and real-time CT fluoroscopy. Eur Radiol 10 (2000) 892-895
    • (2000) Eur Radiol , vol.10 , pp. 892-895
    • LeMaitre, L.1    Mestdagh, P.2    Marecaux-Delomez, J.3
  • 8
    • 0032167868 scopus 로고    scopus 로고
    • A simple laser guide to reduce the screening time during the insertion of dynamic hip screws
    • Conn K.S., and Hallett J.P. A simple laser guide to reduce the screening time during the insertion of dynamic hip screws. Injury 29 (1998) 539-541
    • (1998) Injury , vol.29 , pp. 539-541
    • Conn, K.S.1    Hallett, J.P.2
  • 9
    • 0036090783 scopus 로고    scopus 로고
    • Radiation exposure using laser aiming guide in orthopaedic procedures
    • Harris I., Walker P.M., and Trieu L. Radiation exposure using laser aiming guide in orthopaedic procedures. ANZ J Surg 72 (2002) 349-351
    • (2002) ANZ J Surg , vol.72 , pp. 349-351
    • Harris, I.1    Walker, P.M.2    Trieu, L.3
  • 10
    • 0034463666 scopus 로고    scopus 로고
    • Accuracy of fluoroscopically assisted laser targeting of the cadaveric thoracic and lumbar spine to place transpedicular screws
    • Schwend R.M., Dewire P.J., and Kowalski T.M. Accuracy of fluoroscopically assisted laser targeting of the cadaveric thoracic and lumbar spine to place transpedicular screws. J Spinal Disord 13 (2000) 412-418
    • (2000) J Spinal Disord , vol.13 , pp. 412-418
    • Schwend, R.M.1    Dewire, P.J.2    Kowalski, T.M.3
  • 11
    • 0141590309 scopus 로고    scopus 로고
    • Laser-assisted fluoroscopic puncture: a new technique for accessing the kidney
    • Bilen C.Y., Asci R., Sarikaya S., et al. Laser-assisted fluoroscopic puncture: a new technique for accessing the kidney. J Endourol 17 (2003) 485-491
    • (2003) J Endourol , vol.17 , pp. 485-491
    • Bilen, C.Y.1    Asci, R.2    Sarikaya, S.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.