Osteolysis and particle disease in hip replacement: A review
-
Harris W. H. Osteolysis and particle disease in hip replacement: a review. Acta Orthop. 1994 ; 65 (1). 113-123
-
(1994)
Acta Orthop.
, vol.65
, Issue.1
, pp. 113-123
-
-
Harris, W.H.1
-
3
-
-
0033029624
-
Relationship of acetabular wear to osteolysis and loosening in to total hip arthroplasty
-
Sochart D. H. Relationship of acetabular wear to osteolysis and loosening in to total hip arthroplasty. Clin. Orthop. 1999 ; 363: 135-150
-
(1999)
Clin. Orthop.
, vol.363
, pp. 135-150
-
-
Sochart, D.H.1
-
4
-
-
2442419655
-
Early failure due to osteolysis in highly cross-linked ultra high molecular weight polyethylene: A case report
-
Bradford L., Kurland M., Sankaran H., Kim H., Pruitt L., Ries M. Early failure due to osteolysis in highly cross-linked ultra high molecular weight polyethylene: a case report. J. Bone Joint Surg. Am. 2004 ; 86: 1051-1056
-
(2004)
J. Bone Joint Surg. Am.
, vol.86
, pp. 1051-1056
-
-
Bradford, L.1
Kurland, M.2
Sankaran, H.3
Kim, H.4
Pruitt, L.5
Ries, M.6
-
5
-
-
1842473877
-
Recurrent dislocation after revision total hip replacement with a large prosthetic femoral head: A case report
-
Halley D., Glassman A., Crowninshield R. D. Recurrent dislocation after revision total hip replacement with a large prosthetic femoral head: a case report. J. Bone Joint Surg. Am. 2004 ; 86: 827-830
-
(2004)
J. Bone Joint Surg. Am.
, vol.86
, pp. 827-830
-
-
Halley, D.1
Glassman, A.2
Crowninshield, R.D.3
-
6
-
-
0022504260
-
The problem of surface damage in polyethylene total knee components
-
Wright T. M., Bartel D. L. The problem of surface damage in polyethylene total knee components. Clin. Orthop. 1986 ; 205: 67-74
-
(1986)
Clin. Orthop.
, vol.205
, pp. 67-74
-
-
Wright, T.M.1
Bartel, D.L.2
-
7
-
-
0026346472
-
Analysis of the failure of 122 polyethylene inserts from uncemented tibial knee components
-
Collier J. P., Mayor M. B., McNamara J. L., Surprenant V. A., Jensen R. E. Analysis of the failure of 122 polyethylene inserts from uncemented tibial knee components. Clin. Orthop. 1991 ; 273: 232-242
-
(1991)
Clin. Orthop.
, vol.273
, pp. 232-242
-
-
Collier, J.P.1
Mayor, M.B.2
McNamara, J.L.3
Surprenant, V.A.4
Jensen, R.E.5
-
8
-
-
0026655386
-
Polyethylene wear in unicondylar knee prostheses
-
Blunn G. W., Joshi A. B., Lilley P. A., Engelbrecht E., Ryd L., Lindgren L., Hardinge K., Nieder E., Walker P. S. Polyethylene wear in unicondylar knee prostheses. Acta Orthop. Scand. 1992 ; 63: 247-255
-
(1992)
Acta Orthop. Scand.
, vol.63
, pp. 247-255
-
-
Blunn, G.W.1
Joshi, A.B.2
Lilley, P.A.3
Engelbrecht, E.4
Ryd, L.5
Lindgren, L.6
Hardinge, K.7
Nieder, E.8
Walker, P.S.9
-
9
-
-
0027972449
-
Wear patterns on retrieved polyethylene tibial inserts and their relationship to technical considerations during total knee arthroplasty
-
Wasielewski R. C., Galante J. O., Leighty R. M., Natarajan R. N., Rosenberg A. G. Wear patterns on retrieved polyethylene tibial inserts and their relationship to technical considerations during total knee arthroplasty. Clin. Orthop. 1994 ; 299: 31-43
-
(1994)
Clin. Orthop.
, vol.299
, pp. 31-43
-
-
Wasielewski, R.C.1
Galante, J.O.2
Leighty, R.M.3
Natarajan, R.N.4
Rosenberg, A.G.5
-
10
-
-
0028008566
-
Posteromedial tibial polyethylene failure in total knee replacements
-
Lewis P., Rorabeck C. H., Bourne R. B., Devane P. Posteromedial tibial polyethylene failure in total knee replacements. Clin. Orthop. 1994 ; 299: 11-17
-
(1994)
Clin. Orthop.
, vol.299
, pp. 11-17
-
-
Lewis, P.1
Rorabeck, C.H.2
Bourne, R.B.3
Devane, P.4
-
11
-
-
4444233039
-
Deformation, yielding, fracture and fatigue behaviour of conventional and highly cross-linked ultra high molecular weight polyethylene
-
Pruitt L. A. Deformation, yielding, fracture and fatigue behaviour of conventional and highly cross-linked ultra high molecular weight polyethylene. Biomaterials. 2005 ; 26: 905-915
-
(2005)
Biomaterials
, vol.26
, pp. 905-915
-
-
Pruitt, L.A.1
-
13
-
-
0141993638
-
Clinical performance of a highly cross-linked polyethylene at two years in total hip arthroplasty: A randomized prospective trial
-
55-59
-
Martell J. M., Verner J. J., Incavo S. J. Clinical performance of a highly cross-linked polyethylene at two years in total hip arthroplasty: a randomized prospective trial. J. Arthropl. 2003 ; 18 (7). S1 55-59
-
(2003)
J. Arthropl.
, vol.18
, Issue.7
, pp. 1
-
-
Martell, J.M.1
Verner, J.J.2
Incavo, S.J.3
-
14
-
-
58249094140
-
Five year comparative study of highly cross-linked (cross fire) and traditional polyethylene
-
Rajadhyaksha A. D., Brotea C., Cheung Y., Kuhn C., Ramakrishna R., Zelicof S. B. Five year comparative study of highly cross-linked (cross fire) and traditional polyethylene. J. Arthropl. 2009 ; 24 (2). 161-167
-
(2009)
J. Arthropl.
, vol.24
, Issue.2
, pp. 161-167
-
-
Rajadhyaksha, A.D.1
Brotea, C.2
Cheung, Y.3
Kuhn, C.4
Ramakrishna, R.5
Zelicof, S.B.6
-
15
-
-
78951469231
-
The incidence of acetabular osteolysis in young patients with conventional versus highly cross linked polyethylene
-
Mall N. A., Nunley R. M., Zhu J. J., Maloney W. J., Barrack R. L., Clohisy J. C. The incidence of acetabular osteolysis in young patients with conventional versus highly cross linked polyethylene. Clin. Orthop. Relat. Res. 2011 ; 469: 372-381
-
(2011)
Clin. Orthop. Relat. Res.
, vol.469
, pp. 372-381
-
-
Mall, N.A.1
Nunley, R.M.2
Zhu, J.J.3
Maloney, W.J.4
Barrack, R.L.5
Clohisy, J.C.6
-
16
-
-
0018034893
-
Wear characteristics of UHMWPE: A method for accurately measuring extremely low wear rates
-
McKellop H., Clarke I. C., Markolf K. L., Amstutz H. C. Wear characteristics of UHMWPE: a method for accurately measuring extremely low wear rates. J. Biomed. Mater. Res. 1978 ; 12: 895-927
-
(1978)
J. Biomed. Mater. Res.
, vol.12
, pp. 895-927
-
-
McKellop, H.1
Clarke, I.C.2
Markolf, K.L.3
Amstutz, H.C.4
-
17
-
-
0027724402
-
The effect of transfer film and surface roughness on the wear of lubricated UHMWPE
-
Cooper J. R., Dowson D., Fisher J. The effect of transfer film and surface roughness on the wear of lubricated UHMWPE. Clin. Mater. 1993 ; 14: 295-302
-
(1993)
Clin. Mater.
, vol.14
, pp. 295-302
-
-
Cooper, J.R.1
Dowson, D.2
Fisher, J.3
-
18
-
-
0030331546
-
Wear in retrieved Charnley acetabular sockets
-
Hall R. M., Unsworth A., Shiney P., Wroblewski B. M. Wear in retrieved Charnley acetabular sockets. Proc. IMechE, Part H: J. Engineering in Medicine. 1996 ; 210 (H3). 197-207
-
(1996)
Proc. IMechE, Part H: J. Engineering in Medicine
, vol.210
, Issue.H3
, pp. 197-207
-
-
Hall, R.M.1
Unsworth, A.2
Shiney, P.3
Wroblewski, B.M.4
-
19
-
-
70349663249
-
Biopolymer wear screening rig validated to ASTM F732-00 and against clinical data
-
Joyce T. J. Biopolymer wear screening rig validated to ASTM F732-00 and against clinical data. Tribol. Mat., Surf. Inter. 2007 ; 1 (2). 63-67
-
(2007)
Tribol. Mat., Surf. Inter.
, vol.1
, Issue.2
, pp. 63-67
-
-
Joyce, T.J.1
-
21
-
-
0042957553
-
Lubrication and wear of the Charnley, Charnley-Muller, and McKee-Farrar prostheses with special regard to their clinical behavior
-
Simon S. R., Radin E. L. Lubrication and wear of the Charnley, Charnley-Muller, and McKee-Farrar prostheses with special regard to their clinical behavior. Proceedings of First Open Scientific Meeting of the Hip Society ; Mosby, St Louis ;. 33.
-
Proceedings of First Open Scientific Meeting of the Hip Society
-
-
Simon, S.R.1
Radin, E.L.2
-
22
-
-
0019897146
-
The wear characteristics of ultrahigh molecular weight polyethylene against a high density alumina ceramic under wet (distilled water) and dry conditions
-
Dowson D., Harding R. T. The wear characteristics of ultrahigh molecular weight polyethylene against a high density alumina ceramic under wet (distilled water) and dry conditions. Wear. 1982 ; 75: 313-331
-
(1982)
Wear
, vol.75
, pp. 313-331
-
-
Dowson, D.1
Harding, R.T.2
-
23
-
-
0025834740
-
Low wear rate of UHMWPE against zirconia ceramic (Y-PSZ) in comparison to alumina ceramic and SUS 316L alloy
-
Kumar P., Oka M., Ikeuchi K., Shimizu K., Yamamuro T., Okumura H., Kotoura Y. Low wear rate of UHMWPE against zirconia ceramic (Y-PSZ) in comparison to alumina ceramic and SUS 316L alloy. J. Biomed. Mater. Res. 1991 ; 25: 813-828
-
(1991)
J. Biomed. Mater. Res.
, vol.25
, pp. 813-828
-
-
Kumar, P.1
Oka, M.2
Ikeuchi, K.3
Shimizu, K.4
Yamamuro, T.5
Okumura, H.6
Kotoura, Y.7
-
24
-
-
0030248625
-
Wear testing of materials and surfaces for total knee replacement
-
Walker P. S., Blunn G. W., Lilley P. A. Wear testing of materials and surfaces for total knee replacement. J. Biomed. Mater. Res. 1996 ; 33: 159-175
-
(1996)
J. Biomed. Mater. Res.
, vol.33
, pp. 159-175
-
-
Walker, P.S.1
Blunn, G.W.2
Lilley, P.A.3
-
25
-
-
0030331545
-
The importance of multidirectional motion on the wear of polyethylene
-
Bragdon C. R., O'Connor D. O., Lowenstein J. D., Jasty M., Syniuta W. D. The importance of multidirectional motion on the wear of polyethylene. Proc. IMechE, Part H: J. Engineering in Medicine. 1996 ; 210: 157-165
-
(1996)
Proc. IMechE, Part H: J. Engineering in Medicine
, vol.210
, pp. 157-165
-
-
Bragdon, C.R.1
O'Connor, D.O.2
Lowenstein, J.D.3
Jasty, M.4
Syniuta, W.D.5
-
26
-
-
0032126428
-
A multidirectional motion pin-on-disk wear test method for prosthetic joint materials
-
Saikko V. A multidirectional motion pin-on-disk wear test method for prosthetic joint materials. J. Biomed. Mater. Res. 1998 ; 41: 58-64
-
(1998)
J. Biomed. Mater. Res.
, vol.41
, pp. 58-64
-
-
Saikko, V.1
-
27
-
-
0033635152
-
A multi-directional wear screening device and preliminary results of UHMWPE articulating against stainless steel
-
Joyce T. J., Monk D., Scholes S. C., Unsworth A. A multi-directional wear screening device and preliminary results of UHMWPE articulating against stainless steel. Biomed. Mater. Eng. 2000 ; 10: 241-249
-
(2000)
Biomed. Mater. Eng.
, vol.10
, pp. 241-249
-
-
Joyce, T.J.1
Monk, D.2
Scholes, S.C.3
Unsworth, A.4
-
29
-
-
0007531262
-
The impact of lubricant protein concentration on the outcome of hip joint simulator wear testing
-
Wang A., Polineni V. K., Essner A., Stark C., Dumbleton J. H. The impact of lubricant protein concentration on the outcome of hip joint simulator wear testing. Proceedings of the 25th Annual Meeting of the Society for Biomaterials, Providence ; RI, USA ;.
-
Proceedings of the 25th Annual Meeting of the Society for Biomaterials, Providence
-
-
Wang, A.1
Polineni, V.K.2
Essner, A.3
Stark, C.4
Dumbleton, J.H.5
-
30
-
-
0035482621
-
Multi-laboratory simulator studies on effects of serum proteins on PTFE cup wear
-
Clarke I. C., Chan F. W., Essner A., Good V., Kaddick C., Lappalainen R., Laurent M., McKellop H., McGarry W., Schroeder D., Selenius M., Shen M. C., Ueno M., Wang A., Yao J. Q. Multi-laboratory simulator studies on effects of serum proteins on PTFE cup wear. Wear. 2001 ; 250: 188-198
-
(2001)
Wear
, vol.250
, pp. 188-198
-
-
Clarke, I.C.1
Chan, F.W.2
Essner, A.3
Good, V.4
Kaddick, C.5
Lappalainen, R.6
Laurent, M.7
McKellop, H.8
McGarry, W.9
Schroeder, D.10
Selenius, M.11
Shen, M.C.12
Ueno, M.13
Wang, A.14
Yao, J.Q.15
-
32
-
-
0042069555
-
The influences of lubricant and material on polymer/CoCr sliding friction
-
Yao Q., Laurent M. P., Johnson T. S., Blanchard C. R., Crowninshield R. D. The influences of lubricant and material on polymer/CoCr sliding friction. Wear. 2003 ; 255: 780-784
-
(2003)
Wear
, vol.255
, pp. 780-784
-
-
Yao, Q.1
Laurent, M.P.2
Johnson, T.S.3
Blanchard, C.R.4
Crowninshield, R.D.5
-
33
-
-
0031253559
-
Wear of prosthetic joint materials in various lubricants
-
Ahlroos T., Saikko V. Wear of prosthetic joint materials in various lubricants. Wear. 1997 ; 211: 113-119
-
(1997)
Wear
, vol.211
, pp. 113-119
-
-
Ahlroos, T.1
Saikko, V.2
-
34
-
-
85006577810
-
A review of lubrication conditions for wear simulation in artificial hip replacements
-
Brown S. S., Clarke I. C. A review of lubrication conditions for wear simulation in artificial hip replacements. Tribol. Trans. 2006 ; 49: 72-78
-
(2006)
Tribol. Trans.
, vol.49
, pp. 72-78
-
-
Brown, S.S.1
Clarke, I.C.2
-
35
-
-
0346209911
-
The proteins of synovial fluid: A study of the α1/α2 globulin ratio
-
Binette J. P., Schmid K. The proteins of synovial fluid: a study of the α1/α2 globulin ratio. Arthritis Rheum. 1965 ; 8 (1). 14-28
-
(1965)
Arthritis Rheum.
, vol.8
, Issue.1
, pp. 14-28
-
-
Binette, J.P.1
Schmid, K.2
-
37
-
-
33645274875
-
Effect of low protein concentration lubricants in hip simulators
-
Tateiwa T., Clarke I. C., Shirasu H., Masaoka T., Shishido T., Yamamoto K. Effect of low protein concentration lubricants in hip simulators. J. Orthop. Sci. 2006 ; 11: 204-211
-
(2006)
J. Orthop. Sci.
, vol.11
, pp. 204-211
-
-
Tateiwa, T.1
Clarke, I.C.2
Shirasu, H.3
Masaoka, T.4
Shishido, T.5
Yamamoto, K.6
-
38
-
-
0030627862
-
Frictional heating of bearing materials tested in hip joint wear simulator
-
Lu Z., McKellop H. A. Frictional heating of bearing materials tested in hip joint wear simulator. Proc. IMechE, Part H: J. Engineering in Medicine. 1997 ; 211: 101-108
-
(1997)
Proc. IMechE, Part H: J. Engineering in Medicine
, vol.211
, pp. 101-108
-
-
Lu, Z.1
McKellop, H.A.2
-
39
-
-
0034507657
-
Influence of gelatin and bovine serum lubricants on ultra-high molecular weight polyethylene wear debris generated in in vitro simulations
-
Bell J., Besong A. A., Tipper J. L., Ingham E., Wroblewski B. M., Stone M. H., Fisher J. Influence of gelatin and bovine serum lubricants on ultra-high molecular weight polyethylene wear debris generated in in vitro simulations. Proc. IMechE, Part H: J. Engineering in Medicine. 2000 ; 214: 513-518
-
(2000)
Proc. IMechE, Part H: J. Engineering in Medicine
, vol.214
, pp. 513-518
-
-
Bell, J.1
Besong, A.A.2
Tipper, J.L.3
Ingham, E.4
Wroblewski, B.M.5
Stone, M.H.6
Fisher, J.7
-
41
-
-
84862884881
-
Weariest: Influence of monoclinic content at the surface of zirconia heads
-
Cales B. Weariest: influence of monoclinic content at the surface of zirconia heads. Norton Desmarquest Fine Ceramics ; Evreux Cedex, France ;.
-
Norton Desmarquest Fine Ceramics
-
-
Cales, B.1
-
42
-
-
0016942059
-
The wear of plastic materials in the hip-joint
-
Charnley J. The wear of plastic materials in the hip-joint. Plast. Rubber. 1976 ; 1: 59-63
-
(1976)
Plast. Rubber
, vol.1
, pp. 59-63
-
-
Charnley, J.1
-
43
-
-
0032619808
-
The influence of lubricant on the morphology of UHMWPE wear debris generated in laboratory tests
-
Besong A. A., Tipper J. L., Mathews B. J., Ingham E., Stone M. H., Fisher J. The influence of lubricant on the morphology of UHMWPE wear debris generated in laboratory tests. Proc. IMechE, Part H: J. Engineering in Medicine. 1999 ; 213 (2). 155-158
-
(1999)
Proc. IMechE, Part H: J. Engineering in Medicine
, vol.213
, Issue.2
, pp. 155-158
-
-
Besong, A.A.1
Tipper, J.L.2
Mathews, B.J.3
Ingham, E.4
Stone, M.H.5
Fisher, J.6
-
44
-
-
0028439173
-
Comparative study of the wear of UHMWPE with zirconia ceramic and stainless steel femoral heads in artificial hip joints
-
Derbyshire B., Fisher J., Downson D., Hardaker C., Brummitt K. Comparative study of the wear of UHMWPE with zirconia ceramic and stainless steel femoral heads in artificial hip joints. Med. Eng. Phys. 1994 ; 16 (3). 229-236
-
(1994)
Med. Eng. Phys.
, vol.16
, Issue.3
, pp. 229-236
-
-
Derbyshire, B.1
Fisher, J.2
Downson, D.3
Hardaker, C.4
Brummitt, K.5
-
45
-
-
0030152397
-
Comparison of the size and morphology of UHMWPE wear debris produced by a hip joint simulator under serum and water lubricated conditions
-
Wang A., Essner A., Stark C., Dumbleton J. H. Comparison of the size and morphology of UHMWPE wear debris produced by a hip joint simulator under serum and water lubricated conditions. Biomaterials. 1996 ; 17: 865-871
-
(1996)
Biomaterials
, vol.17
, pp. 865-871
-
-
Wang, A.1
Essner, A.2
Stark, C.3
Dumbleton, J.H.4
-
46
-
-
0027437359
-
Wear of polyethylene acetabular cup. Metallic and ceramic heads compared in a hip simulator
-
Saikko V., Paavolainen P. O., Slatis P. Wear of polyethylene acetabular cup. Metallic and ceramic heads compared in a hip simulator. Acta Orthop. Scand. 1993 ; 64: 391-403
-
(1993)
Acta Orthop. Scand.
, vol.64
, pp. 391-403
-
-
Saikko, V.1
Paavolainen, P.O.2
Slatis, P.3
-
47
-
-
0028929254
-
Isolation of predominantly submicron sized UHMWPE wear particles from periprosthetic tissues
-
Campbell P., Ma S., Yeom B., McKellop H., Schmalzried T. P., Amstut H. C. Isolation of predominantly submicron sized UHMWPE wear particles from periprosthetic tissues. J. Biomed. Mater. Res. 1995 ; 29: 127-131
-
(1995)
J. Biomed. Mater. Res.
, vol.29
, pp. 127-131
-
-
Campbell, P.1
Ma, S.2
Yeom, B.3
McKellop, H.4
Schmalzried, T.P.5
Amstut, H.C.6
-
48
-
-
0029255360
-
Wear mechanisms of UHMWPE in total joint replacements
-
Wang A., Sun D. C., Stark C., Dumbleton J. H. Wear mechanisms of UHMWPE in total joint replacements. Wear. 1995 ; 181 183: 241-249
-
(1995)
Wear
, vol.181-183
, pp. 241-249
-
-
Wang, A.1
Sun, D.C.2
Stark, C.3
Dumbleton, J.H.4
-
49
-
-
0019620861
-
Friction and wear properties of polymer, metal and ceramic prosthetic joint materials evaluated on a multi channel screening device
-
McKellop H., Clarke I. C., Markolf K., Amstutz H. Friction and wear properties of polymer, metal and ceramic prosthetic joint materials evaluated on a multi channel screening device. J. Biomed. Mater. Res. 1981 ; 15: 619-653
-
(1981)
J. Biomed. Mater. Res.
, vol.15
, pp. 619-653
-
-
McKellop, H.1
Clarke, I.C.2
Markolf, K.3
Amstutz, H.4
-
50
-
-
25144435848
-
Friction and wear mechanisms in hip prosthesis: Comparison of joint materials behaviour in several lubricants
-
Gispert M. P., Serro A. P., Colco R., Saramago B. Friction and wear mechanisms in hip prosthesis: comparison of joint materials behaviour in several lubricants. Wear. 2006 ; 260: 149-158
-
(2006)
Wear
, vol.260
, pp. 149-158
-
-
Gispert, M.P.1
Serro, A.P.2
Colco, R.3
Saramago, B.4
-
51
-
-
0030560772
-
Water and bovine serum lubrication compared in a simulator PTFE/CoCr wear model
-
Clark I. C. Water and bovine serum lubrication compared in a simulator PTFE/CoCr wear model. J. Appl. Biomater. 1996 ; 33: 275-283
-
(1996)
J. Appl. Biomater.
, vol.33
, pp. 275-283
-
-
Clark, I.C.1
-
52
-
-
0030560772
-
Water and bovine serum lubrication compared in simulator PTFE/CoCr wear model
-
Good V. D., Clarke I. C., Anissian L. Water and bovine serum lubrication compared in simulator PTFE/CoCr wear model. J. Biomed. Mater. Res. 1996 ; 33 (4). 275-283
-
(1996)
J. Biomed. Mater. Res.
, vol.33
, Issue.4
, pp. 275-283
-
-
Good, V.D.1
Clarke, I.C.2
Anissian, L.3
-
55
-
-
77954791566
-
Biochemical comparisons of osteoarthritic human synovial fluid with calf sera used in knee simulator wear testing
-
Brandt J. M., Briere L. K., Marr J., MacDonald S. J., Bourne R. B., Medley J. B. Biochemical comparisons of osteoarthritic human synovial fluid with calf sera used in knee simulator wear testing. J. Biomed. Mater. Res. A. 2010 ; 94A (3). 961-971
-
(2010)
J. Biomed. Mater. Res. A
, vol.94
, Issue.3
, pp. 961-971
-
-
Brandt, J.M.1
Briere, L.K.2
Marr, J.3
MacDonald, S.J.4
Bourne, R.B.5
Medley, J.B.6
-
56
-
-
0009896222
-
Effect of lubricant protein concentration on the wear of UHMWPE acetabular cups against cobalt-chrome and alumina femoral heads
-
Polineni V. K., Wang A., Essner A., Stark C., Dumbleton J. H. Effect of lubricant protein concentration on the wear of UHMWPE acetabular cups against cobalt-chrome and alumina femoral heads. Transactions of 23rd Annual Meeting of the Society for Biomaterials ; New Orleans, LA ;.
-
Transactions of 23rd Annual Meeting of the Society for Biomaterials
-
-
Polineni, V.K.1
Wang, A.2
Essner, A.3
Stark, C.4
Dumbleton, J.H.5
-
57
-
-
84862884874
-
The impact of lubricant protein concentration on the outcome of hip joint simulator testing
-
Wang A., Polineni V. K., Essner A., Stark C., Dumbleton J. H. The impact of lubricant protein concentration on the outcome of hip joint simulator testing. 45th ORS ; Anaheim, CA ;.
-
45th ORS
-
-
Wang, A.1
Polineni, V.K.2
Essner, A.3
Stark, C.4
Dumbleton, J.H.5
-
59
-
-
84862893645
-
-
Sigma-Aldrich. Bovine Calf Serum Data Sheet Lot 117K8404", Sigmaaldrich
-
Sigma-Aldrich. Bovine Calf Serum Data Sheet Lot 117K8404", Sigmaaldrich.
-
-
-
-
60
-
-
0346725975
-
The effect of lubricant composition on in vitro wear testing of polymeric acetabular components
-
Wang A., Essner A., Schmidig G. The effect of lubricant composition on in vitro wear testing of polymeric acetabular components. J. Biomed. Mater. Res., Part B: Appl. Biomater. 2004 ; 68B: 45-52
-
(2004)
J. Biomed. Mater. Res., Part B: Appl. Biomater.
, vol.68
, pp. 45-52
-
-
Wang, A.1
Essner, A.2
Schmidig, G.3
-
61
-
-
0042230975
-
Effect of lubricant protein concentration on the wear of ultrahigh molecular weight polyethylene sliding against a CoCr counterface
-
Saikko V. Effect of lubricant protein concentration on the wear of ultrahigh molecular weight polyethylene sliding against a CoCr counterface. Trans ASME. 2003 ; 125: 638-642
-
(2003)
Trans ASME
, vol.125
, pp. 638-642
-
-
Saikko, V.1
-
62
-
-
77955536914
-
The effect of serum protein concentration on wear rates in a hip simulator
-
John K. S. The effect of serum protein concentration on wear rates in a hip simulator. J. Biomat. Appl. 2010 ; 25: 145-159
-
(2010)
J. Biomat. Appl.
, vol.25
, pp. 145-159
-
-
John, K.S.1
-
63
-
-
0027416313
-
Hyaluronate in total hip replacement
-
Saari H., Santavirta S., Nordström D., Paavolainen P., Konttinen Y. T. Hyaluronate in total hip replacement. J. Rheumatol. 1993 ; 20 (1). 87-90
-
(1993)
J. Rheumatol.
, vol.20
, Issue.1
, pp. 87-90
-
-
Saari, H.1
Santavirta, S.2
Nordström, D.3
Paavolainen, P.4
Konttinen, Y.T.5
-
64
-
-
0008293323
-
Comparative distribution of proteins and glycoproteins of serum and synovial fluid
-
Decker B., McKenzie B. F., McGuckin W. F., Slocumb C. H. Comparative distribution of proteins and glycoproteins of serum and synovial fluid. Arthritis Rheum. 1959 ; 2 (2). 162-177
-
(1959)
Arthritis Rheum.
, vol.2
, Issue.2
, pp. 162-177
-
-
Decker, B.1
McKenzie, B.F.2
McGuckin, W.F.3
Slocumb, C.H.4
-
65
-
-
0028836831
-
The origin of submicron polyethylene wear debris in total hip arthoplasty
-
McKellop H., Campbell P., Park S. H., Schmalzried T. P., Grigoris P., Amstutz H. C., Sarmiento A. The origin of submicron polyethylene wear debris in total hip arthoplasty. Clin. Orthop. 1995 ; 311: 3-20
-
(1995)
Clin. Orthop.
, vol.311
, pp. 3-20
-
-
McKellop, H.1
Campbell, P.2
Park, S.H.3
Schmalzried, T.P.4
Grigoris, P.5
Amstutz, H.C.6
Sarmiento, A.7
-
66
-
-
0035876256
-
Wear simulation of total hip prostheses with polyethylene against CoCr, alumina and diamond-like carbon
-
Saikko V., Ahlroos T., Calonius O., Keränen J. Wear simulation of total hip prostheses with polyethylene against CoCr, alumina and diamond-like carbon. Biomaterials. 2001 ; 22: 1507-514
-
(2001)
Biomaterials
, vol.22
, pp. 1507-1514
-
-
Saikko, V.1
Ahlroos, T.2
Calonius, O.3
Keränen, J.4
-
67
-
-
0031686498
-
Effect of femoral head surface roughness on the wear of ultrahigh molecular weight polyethylene acetabular cups
-
Wang A., Polineni V. K., Stark C., Dumbleton J. H. Effect of femoral head surface roughness on the wear of ultrahigh molecular weight polyethylene acetabular cups. J. Arthropl. 1998 ; 13: 615-620
-
(1998)
J. Arthropl.
, vol.13
, pp. 615-620
-
-
Wang, A.1
Polineni, V.K.2
Stark, C.3
Dumbleton, J.H.4
-
68
-
-
0032616832
-
Type of motion and lubricant in wear simulation of polyethylene acetabular cup
-
Saikko V., Ahlroos T. Type of motion and lubricant in wear simulation of polyethylene acetabular cup. Proc. IMechE, Part H: J. Engineering in Medicine. 1999 ; 213: 301-310
-
(1999)
Proc. IMechE, Part H: J. Engineering in Medicine
, vol.213
, pp. 301-310
-
-
Saikko, V.1
Ahlroos, T.2
-
69
-
-
84928977438
-
Quantitative analysis of serum degradation and its effect on the outcome of hip joint simulator wear testing of UHMWPE
-
Wang A., Polineni V. K., Essner A., Stark C., Dumbleton J. H. Quantitative analysis of serum degradation and its effect on the outcome of hip joint simulator wear testing of UHMWPE. Transactions of the 45th Orthopaedic Research Society Meeting ; Anaheim, CA ;.
-
Transactions of the 45th Orthopaedic Research Society Meeting
-
-
Wang, A.1
Polineni, V.K.2
Essner, A.3
Stark, C.4
Dumbleton, J.H.5
-
71
-
-
77955384560
-
Characterization of protein degradation in serum based lubricants during simulation wear testing of metal-on-metal hip prostheses
-
Maskiewicz V. K., Williams P. A., Prates S. J., Bowsher J. G., Clarke I. C. Characterization of protein degradation in serum based lubricants during simulation wear testing of metal-on-metal hip prostheses. J. Biomed. Mat. Res., Part B: Appl. Biomat. 2010 ; 94B (2). 429-440
-
(2010)
J. Biomed. Mat. Res., Part B: Appl. Biomat.
, vol.94
, Issue.2
, pp. 429-440
-
-
Maskiewicz, V.K.1
Williams, P.A.2
Prates, S.J.3
Bowsher, J.G.4
Clarke, I.C.5
-
72
-
-
84862888292
-
A comparison of biological lubricants to bovine calf serum in total joint wear testing
-
Yao J. Q, Laurent M. P., Gilbertson L. N., Blanchard C. R., Crowninshield R. D., Jacobs J. J. A comparison of biological lubricants to bovine calf serum in total joint wear testing. 48th Annual Meeting of the Orthopaedic Research Society ; ;. 1004.
-
48th Annual Meeting of the Orthopaedic Research Society
-
-
Yao, J.Q.1
Laurent, M.P.2
Gilbertson, L.N.3
Blanchard, C.R.4
Crowninshield, R.D.5
Jacobs, J.J.6
-
73
-
-
84862884877
-
-
Available from: http://www.bbraun.com.au/index. cfm66AB39392A5AE626642337DB5AC48B8F.
-
-
-
-
74
-
-
84862888291
-
-
Available from: http://www.doctissimo.fr/medicament-PLASMION.htm
-
-
-
-
75
-
-
34548414633
-
Rheological properties of synovial fluid
-
Fam H., Bryant J. T., Kontopoulou M. Rheological properties of synovial fluid. Biorheology. 2007 ; 44: 59-74
-
(2007)
Biorheology
, vol.44
, pp. 59-74
-
-
Fam, H.1
Bryant, J.T.2
Kontopoulou, M.3
-
77
-
-
0141600293
-
-
13, vol. 1, 1997, pp. 81-102 (Williams and Williams, Baltimore). Koopman W. J., ed. Baltimore: Williams and Williams
-
McCarty D. J. Arthritis allied conditions: a text book of rheumatology. 13, vol. 1, 1997, pp. 81-102 (Williams and Williams, Baltimore). Koopman W. J., ed. Baltimore: Williams and Williams ; 1997: 81-102.
-
(1997)
Arthritis Allied Conditions: A Text Book of Rheumatology
, pp. 81-102
-
-
McCarty, D.J.1
-
79
-
-
0031171676
-
Phospholipids as boundary lubricants in wear tests of prosthetic joint materials
-
Saikko V., Ahlroos T. Phospholipids as boundary lubricants in wear tests of prosthetic joint materials. Wear. 1997 ; 207: 86-91
-
(1997)
Wear
, vol.207
, pp. 86-91
-
-
Saikko, V.1
Ahlroos, T.2
-
80
-
-
33845188856
-
The role of SAPL as a boundary lubricant in prosthetic joints
-
Gale L. R., Coller R., Hargreaves D. J., Hills B. A., Crawford R. The role of SAPL as a boundary lubricant in prosthetic joints. Tribol. Int. 2007 ; 40: 601-606
-
(2007)
Tribol. Int.
, vol.40
, pp. 601-606
-
-
Gale, L.R.1
Coller, R.2
Hargreaves, D.J.3
Hills, B.A.4
Crawford, R.5
-
82
-
-
0036937210
-
Highly viscous sodium hyaluronate and joint lubrication
-
Mori S., Naito M., Moriyama S. Highly viscous sodium hyaluronate and joint lubrication. Int. Orthop. 2002 ; 26: 116-121
-
(2002)
Int. Orthop.
, vol.26
, pp. 116-121
-
-
Mori, S.1
Naito, M.2
Moriyama, S.3
-
83
-
-
33748475338
-
Increased total knee arthroplasty ultra-high molecular weight polyethylene wear using a clinically relevant hyaluronic acid simulator lubricant
-
DesJardins J., Aurora A., Tanner S. L., Pace T. B., Acampora K. B., LaBerge M. Increased total knee arthroplasty ultra-high molecular weight polyethylene wear using a clinically relevant hyaluronic acid simulator lubricant. Proc. IMechE, Part H: J. Engineering in Medicine. 2006 ; 220 (H1). 609-623
-
(2006)
Proc. IMechE, Part H: J. Engineering in Medicine
, vol.220
, Issue.H1
, pp. 609-623
-
-
Desjardins, J.1
Aurora, A.2
Tanner, S.L.3
Pace, T.B.4
Acampora, K.B.5
Laberge, M.6
-
84
-
-
0032307647
-
The lubricating ability of biomembrane models with dipalmitoyl phosphatidylcholine and υ-globulin
-
Higaki H., Murakami T., Nakanishih Y., Miura H., Mawatari T., Iwamoto Y. The lubricating ability of biomembrane models with dipalmitoyl phosphatidylcholine and υ-globulin. Proc. IMechE, Part H: J. Engineering in Medicine. 1998 ; 212 (H5). 337-346
-
(1998)
Proc. IMechE, Part H: J. Engineering in Medicine
, vol.212
, Issue.H5
, pp. 337-346
-
-
Higaki, H.1
Murakami, T.2
Nakanishih, Y.3
Miura, H.4
Mawatari, T.5
Iwamoto, Y.6
-
85
-
-
33749878090
-
Effect of synovia constituents on friction and wear of ultra high molecular weight polyethylene sliding against prosthetic joint materials
-
Sawae Y., Murakami T., Chen J. Effect of synovia constituents on friction and wear of ultra high molecular weight polyethylene sliding against prosthetic joint materials. Wear. 1998 ; 77: 1-7
-
(1998)
Wear
, vol.77
, pp. 1-7
-
-
Sawae, Y.1
Murakami, T.2
Chen, J.3
-
86
-
-
77049140451
-
The physiological function of hyaluronic acid in synovial fluid; Viscous, elastic and lubricant properties
-
Ogston A. G., Stainer J. E. The physiological function of hyaluronic acid in synovial fluid; viscous, elastic and lubricant properties. J. Physiol. 1953 ; 119: 244-252
-
(1953)
J. Physiol.
, vol.119
, pp. 244-252
-
-
Ogston, A.G.1
Stainer, J.E.2
-
87
-
-
0000788226
-
-
Comper W. D., ed. Amsterdam: Harwood Academic Publishers
-
Levick J. R., Price F. M., Mason R. M. Extra cellular matrix, tissue function. Comper W. D., ed. Amsterdam: Harwood Academic Publishers ; 1996: 348-354.
-
(1996)
Extra Cellular Matrix, Tissue Function
, pp. 348-354
-
-
Levick, J.R.1
Price, F.M.2
Mason, R.M.3
-
89
-
-
16644389660
-
The role of joint fluid in the tribology of total joint arthoplasty
-
Mazzucco D., Spector M. The role of joint fluid in the tribology of total joint arthoplasty. Clin. Ortho. 2004 ; 429: 17-32
-
(2004)
Clin. Ortho.
, vol.429
, pp. 17-32
-
-
Mazzucco, D.1
Spector, M.2
-
90
-
-
1642351728
-
Composition of joint fluid in patients undergoing total knee replacement and revision arthroplasty: Correlation with flow properties
-
Mazzucco D., Scott R., Spector M. Composition of joint fluid in patients undergoing total knee replacement and revision arthroplasty: correlation with flow properties. Biomaterials. 2004 ; 25: 4433-4445
-
(2004)
Biomaterials
, vol.25
, pp. 4433-4445
-
-
Mazzucco, D.1
Scott, R.2
Spector, M.3
-
91
-
-
0022343146
-
Concentration and molecular weight of sodium hyaluronate in synovial fluid from patients with rheumatoid arthritis and other arthropathies
-
Dahl L. B., Dahl I. M., Engstrom-Laurent A., Granath K. Concentration and molecular weight of sodium hyaluronate in synovial fluid from patients with rheumatoid arthritis and other arthropathies. Ann. Rheum. Dis. 1985 ; 44: 817-822
-
(1985)
Ann. Rheum. Dis.
, vol.44
, pp. 817-822
-
-
Dahl, L.B.1
Dahl, I.M.2
Engstrom-Laurent, A.3
Granath, K.4
-
92
-
-
0031466954
-
Assay of synovial fluid parameters: Hyaluronan concentration as a potential marker for joint diseases
-
Praest B. M, Greiling H., Kock R. Assay of synovial fluid parameters: hyaluronan concentration as a potential marker for joint diseases. Clin. Chim. Act. 1997 ; 266: 117-128
-
(1997)
Clin. Chim. Act.
, vol.266
, pp. 117-128
-
-
Praest, B.M.1
Greiling, H.2
Kock, R.3
-
94
-
-
0014118432
-
Hyaluronic acid in synovial fluid. I. Molecular parameters of hyaluronic acid in normal and arthritis human fluids
-
Balazs E. A., Watson D., Duff I. F., Roseman S. Hyaluronic acid in synovial fluid. I. Molecular parameters of hyaluronic acid in normal and arthritis human fluids. Arthritis Rheum. 1967 ; 10: 357-376
-
(1967)
Arthritis Rheum.
, vol.10
, pp. 357-376
-
-
Balazs, E.A.1
Watson, D.2
Duff, I.F.3
Roseman, S.4
-
95
-
-
0027817288
-
Comparisons of the oscillatory shear viscoelasticity and composition of pathological fluids
-
Gomez J. E., Thurston G. B. Comparisons of the oscillatory shear viscoelasticity and composition of pathological fluids. Biorheology. 1993 ; 30: 409-427
-
(1993)
Biorheology
, vol.30
, pp. 409-427
-
-
Gomez, J.E.1
Thurston, G.B.2
-
96
-
-
11544311243
-
The intrinsic viscosity of synovial fluid hyaluronic acid
-
Bollet A. J. The intrinsic viscosity of synovial fluid hyaluronic acid. J. Lab. Clin. Med. 1956 ; 48: 712-728
-
(1956)
J. Lab. Clin. Med.
, vol.48
, pp. 712-728
-
-
Bollet, A.J.1
-
97
-
-
0027213271
-
Viscoelastic and transient network properties of HA as function of the concentration
-
De Smedt S., Deketser P., Ribitsch V., Lauwers A., Demeester J. Viscoelastic and transient network properties of HA as function of the concentration. Biorheology. 1993 ; 30: 31-41
-
(1993)
Biorheology
, vol.30
, pp. 31-41
-
-
De Smedt, S.1
Deketser, P.2
Ribitsch, V.3
Lauwers, A.4
Demeester, J.5
-
98
-
-
0000327139
-
Rheology of synovial fluids and substitute polymer
-
Schurz J. Rheology of synovial fluids and substitute polymer. J. Macromol. Sci.: Pure. 1996 ; A33: 1249-1262
-
(1996)
J. Macromol. Sci.: Pure.
, vol.33
, pp. 1249-1262
-
-
Schurz, J.1
-
99
-
-
0003929035
-
Studies on the nature and significance of macromolecular complexes in the rheology of synovial fluid from normal and diseased human joints
-
Nuki G., Ferguson J. Studies on the nature and significance of macromolecular complexes in the rheology of synovial fluid from normal and diseased human joints. Rheol. Acta. 1971 ; 10: 8-14
-
(1971)
Rheol. Acta.
, vol.10
, pp. 8-14
-
-
Nuki, G.1
Ferguson, J.2
-
100
-
-
34548392714
-
New methods in synovial fluid rheology and macromolecular network structure
-
Zeidler H., Altmann S. New methods in synovial fluid rheology and macromolecular network structure. Biorheology. 1981 ; 18: 122-127
-
(1981)
Biorheology
, vol.18
, pp. 122-127
-
-
Zeidler, H.1
Altmann, S.2
-
101
-
-
70349659732
-
Wear tests of orthopaedic biopolymers with the biolubricant augmented by a visco-supplement
-
Joyce T. J. Wear tests of orthopaedic biopolymers with the biolubricant augmented by a visco-supplement. Proc. IMechE, Part J: J. Engineering Tribology. 2009 ; 233: 297-302
-
(2009)
Proc. IMechE, Part J: J. Engineering Tribology
, vol.233
, pp. 297-302
-
-
Joyce, T.J.1
-
102
-
-
0021212341
-
Surfactants identified in synovial fluid and their ability to act as boundary lubricants
-
Hills B. A., Butler B. D. Surfactants identified in synovial fluid and their ability to act as boundary lubricants. Ann. Rheum. Dis. 1984 ; 43 (4). 641-648
-
(1984)
Ann. Rheum. Dis.
, vol.43
, Issue.4
, pp. 641-648
-
-
Hills, B.A.1
Butler, B.D.2
-
103
-
-
0035222432
-
The influence of phospholipids concentration in protein containing lubricants on the wear of ultra-high molecular weight polyethylene in artificial hip joints
-
Bell J., Tipper J. L., Ingham E., Stone M. H., Fisher J. The influence of phospholipids concentration in protein containing lubricants on the wear of ultra-high molecular weight polyethylene in artificial hip joints. Proc. IMechE, Part H: J. Engineering in Medicine. 2000 ; 215: 259-263
-
(2000)
Proc. IMechE, Part H: J. Engineering in Medicine
, vol.215
, pp. 259-263
-
-
Bell, J.1
Tipper, J.L.2
Ingham, E.3
Stone, M.H.4
Fisher, J.5
-
104
-
-
0018569849
-
Lipid composition of the tissues of human knee joints. I. Observations in normal joints (articular cartilage, meniscus, ligaments, synovial fluid, synovium, intra-articular fat pad and bone marrow)
-
Rabinowitz J. L., Gregg J. R., Nixon J. E., Schumacher H. R. Lipid composition of the tissues of human knee joints. I. Observations in normal joints (articular cartilage, meniscus, ligaments, synovial fluid, synovium, intra-articular fat pad and bone marrow). Clin. Orthop. Relat. Res. 1979 ; 143: 260-265
-
(1979)
Clin. Orthop. Relat. Res.
, vol.143
, pp. 260-265
-
-
Rabinowitz, J.L.1
Gregg, J.R.2
Nixon, J.E.3
Schumacher, H.R.4
|